We can fix your inverter

Leave a request and find out the cost of repairing your inverter.

Find out the cost of repairs

Photovoltaic Inverter Repair & Diagnostics

  • In-depth diagnostics of inverter failures — including internal explosions, burnt PCBs, and severe hardware faults
  • Root-cause analysis using oscilloscopes, logic analyzers, and load simulations
  • Detection and elimination of software-related faults: EEPROM corruption, firmware bugs, and error code resolution
  • Repair of MPPT modules, power stages, gate drivers, and signal path anomalies
  • Troubleshooting of grid synchronization, DC link stability, and AC waveform distortion
  • Detailed failure reports, waveform captures, and high-resolution photos of defective areas

Inverter Component Restoration & Upgrades

  • Replacement of IGBTs, MOSFETs, optocouplers, control ICs, and passive components
  • Micro-soldering and trace repair for severely damaged circuit boards
  • Custom replacement of rare or obsolete components using 3D-printed or CNC-machined parts
  • Rebuilding of cooling systems: fan units, thermal paste, and heat sink realignment
  • Reinforcement against future failures: conformal coating, transient suppression modules, and enhanced insulation paths
  • Optional firmware optimization for extended inverter lifespan and better grid behavior
  • Includes post-repair testing, load simulation, and full technical documentation with results

Advanced Inverter Diagnostics

  • Complete diagnostics using professional Fluke and Tektronix equipment
  • Electrical parameter analysis with 0.1% precision accuracy
  • Thermal imaging diagnostics to detect hidden defects
  • Insulation and grounding testing according to VDE standards
  • Detailed report with photographic documentation of all problem areas

Control Board Reprogramming

  • Factory firmware restoration for all inverter brands
  • EEPROM and Flash memory programming
  • Software adaptation for specific operating conditions
  • Firmware updates to latest versions
  • Original settings backup and recovery

PCB Board Restoration

  • Circuit trace restoration using micro-soldering techniques
  • BGA component replacement on professional rework stations
  • CPU and microchip reballing services
  • Contact pad restoration and repair
  • Protective coating application against corrosion

Final Quality Testing

  • Complete safety function verification
  • Overload condition testing
  • Calibration of all measurement circuits
  • Quality certificate with comprehensive test protocols

List of errors on the inverter Mitsubishi


By Erik Zaikin
1 min read


### Error Codes

If the ERROR LED lights up, displaying an error code due to a failed grid or your PV generation system, contact your dealer for repair. This subsection describes the typical error codes.

**General Error Codes:**
- **E-00**: Internal switch operates abnormally.
- **E-05**: Configuration information, including settings, has been retrieved inappropriately at startup.
- **E-07**: Internal temperature information cannot be detected.
- **E-08**: Control circuit is functioning improperly.
- **E-09**: An extremely high internal temperature is detected.
- **E-20**: Input voltage has exceeded the maximum limit.
- **E-24**: Overcurrent occurred in the output.
- **E-25**: Overvoltage occurred in the output.
- **E-26**: Dropped voltage occurred in the output.
- **E-28**: Direct current overlapped with the output current.
- **E-29**: An earth fault has occurred.
- **E-30**: Booster circuit is functioning improperly.
- **E-31**: Earth-fault detecting circuit is functioning improperly.
- **E-35**: Thermal fuse has blown.
- **E-37**: An error occurred in the booster circuit.

**Additional Error Codes:**
- **E-43**: Error occurred in the booster circuit.
- **E-44**: Default setting(s) is faulty.
- **E-64**: Overcurrent occurred in the inverter circuit.
- **E-66**: Overvoltage occurred in the output (at high level).
- **E-62**: Overvoltage occurred in the booster circuit.
- **E-72**: Overvoltage occurred in the booster circuit (at high level).
- **E-73**: Overcurrent occurred in the switching element.

Models: PV-PNS04ATL-IT
PV-PNS06ATL-IT
PV-PNS04ATL2-IT
PV-PNS03ATL-IT
PV-PNS04ATL
PV-PNS06ATL
PV-PNS04ATL2
PV-PNS03ATL
PV-S4200-IT
PV-4600-IT
PV-S6000-IT
PV-S4200
PV-4600
PV-S6000