Power Rack Repair Service for ABB, Aurora, Fimer

We provide a 12-month warranty after repairing your inverter module.

Please indicate your inverter brand and model. ( For example: 3M67 )

Please indicate what error code the inverter is giving. (For example: E031)

We'll aim to get back to you within 24 hours.


Professional Power Rack Inverter Repair

Models: 3I19 • 3M04 • 3M05 • 3L07 • 3M67 • 3M06

⚠️ Attention! Errors in central inverter operation can lead to significant energy losses and costly equipment downtime. Don't delay repairs!

🔴 CRITICAL ERRORS (Require Immediate Intervention)

Code Type Description Consequences
E001 Error OC Panel - Input current exceeds maximum threshold Risk of module damage
E004 Error Bulk OV - Capacitor voltage above maximum Power element failure
E005 Error Communication - DSP communication error Complete control loss
E006 Error OC - Output current exceeds maximum threshold Grid disconnection
E007 Error OCH - IGBT current above threshold or IGBT saturation Critical damage
E014 Error Over Temp - Equipment overheating Emergency shutdown
E015 Error Delta Bulk - DC capacitor voltage difference Unstable operation
E024 Error Forbidden State - Impermissible state System lockout
E033 Error UTH - Temperature below minimum threshold Inefficient operation
E035 Error Remote OFF - Remote disconnection Control loss
E037 Error UC Panel - Negative input current above threshold Reverse energy flow
E038 Error FAN Stuck - Central or right fan blocked System overheating
E039 Error DC Switch Open - DC disconnect switch open No DC power
E040 Error TRAS Switch Open - AC disconnect switch open No AC connection
E041 Error Relay AC - Internal AC contactor failed to switch No grid output
E042 Error Bulk UV - Capacitor voltage below minimum Unstable operation
E043 Error Auto exclusion - Module self-exclusion due to repeated failures Complete shutdown
E025 Error RISO - Insulation resistance below minimum threshold Safety threat

🟡 WARNINGS (Require Monitoring)

Code Type Description Recommendations
W004 Warning Grid OV - Grid overvoltage Monitor grid parameters
W005 Warning Grid UV - Grid undervoltage Check grid connection
W006 Warning Grid OF - Grid overfrequency Network monitoring
W007 Warning Grid UF - Grid underfrequency Grid quality analysis
W010 Warning Fan Fail - Left fan blocked Check cooling system
W014 Warning Pneg - Zero export power Operation optimization
W015 Warning Grid df/dt - High frequency change rate Stability control
W016 Warning SPD Switch Open - Surge protection device failure Replace cartridge
W017 Warning JboxFail - Problem with one or more StringCombs Connection diagnostics

💡 Why Professional Repair is Critically Important

Prevent Costly Breakdowns - Timely diagnostics saves up to 80% repair costs

Maximize Energy Efficiency - Restore optimal operating parameters

Extend Service Life - Professional maintenance increases lifespan by 40-60%

Operating Safety - Eliminate risks of electric shock and fire

Standards Compliance - Maintain warranty obligations and certification


⚡ Emergency Cases - Act Immediately!

If you see ANY of these errors - every minute of delay costs money:

🚨 E001, E006, E007 - Current overloads can burn expensive components

🔥 E014 - Overheating leads to cascade failures

⚠️ E025 - Low insulation resistance - LIFE THREATENING

💸 E043 - Self-exclusion = COMPLETE GENERATION SHUTDOWN


🎯 Get Professional Help Right Now!

Our experts will eliminate any Power Rack inverter errors (3I19, 3M04, 3M05, 3L07, 3M67, 3M06) with quality guarantee and minimum downtime.

Emergency repair: 6 hours (+ €300 urgency fee)  🔧 Standard repair: 1-3 business days