Steca
Inverter Event Messages Guide
General Issues
-
Country Code Failed
- Description: Inconsistency between the selected country setting and the stored memory setting.
- Action: Notify your installer.
-
Country Parameters Invalid
- Description: Inverter cannot inject into the grid due to invalid parameters.
- Action: Notify your installer.
-
Device Overheated
- Description: Maximum permissible temperature exceeded despite capacity reduction.
- Action: Check installation conditions; contact installer if frequent.
-
Data Transfer Failed
- Description: Failed setting adoption, e.g., during commissioning.
- Action: Repeat setting; contact installer if frequent.
-
Fan Faulty
- Description: Internal fan defect, may result in reduced capacity operation.
- Action: Notify your installer.
-
Grid Current DC Offset Too High
- Description: DC current power share injected exceeds permissible value.
- Action: Notify your installer.
Grid Issues
-
Grid Frequency Too High/Low
- Description: Grid frequency outside permissible range.
- Action: Contact installer if frequent.
-
Grid Islanding Detected
- Description: No voltage in grid detected, safety shutdown.
- Action: Contact installer if frequent.
-
Grid Relay Defective
- Description: Detected defective grid relay.
- Action: Notify your installer.
-
Grid Voltage Too High/Low
- Description: Grid voltage outside permissible range.
- Action: Contact installer if frequent.
-
Grid Voltage Too High/Low for Reactivation
- Description: After shutdown, grid voltage outside switch-on value.
- Action: Contact installer if frequent.
Internal Issues
-
Internal Error/Info/Warning
- Description: Various internal issues detected.
- Action: Contact your installer if frequent.
-
Isolation Error
- Description: Insulating resistor below permissible value.
- Action: Notify your installer.
-
L and N Swapped
- Description: Outer and neutral conductors incorrectly connected.
- Action: Notify your installer.
-
No Branding
- Description: Incorrect or faulty device data.
- Action: Notify your installer.
Connection and Temperature Issues
-
No Connection to the Energy Meter
- Description: Missing or incorrect communication connection.
- Action: Contact your installer for a check.
-
Overtemperature HSS
- Description: Boost converter temperature exceeded permissible range.
- Action: Check installation conditions; contact installer if frequent.
-
Power Reduction Due to Temperature
- Description: Output power reduced due to maximum temperature reached.
- Action: Check installation conditions; contact installer if frequent.
PV and Current Issues
-
PV Current Too High
- Description: Input current exceeds permissible value.
- Action: Contact your installer if frequent.
-
PV Voltage Too High
- Description: Input voltage exceeds permissible value.
- Action: Switch off DC load-break switch; notify your installer.
-
Reading CountryCode Failed
- Description: Country setting could not be correctly read from memory.
- Action: Notify your installer.
-
Residual Current Too High
- Description: Fault current exceeds permissible value.
- Action: Notify your installer.
Communication and Software Issues
-
RS485 Gateway Activated
- Description: No communication possible via RS485 interface.
- Action: Disconnect and reset inverter (AC reset); have installer perform this.
-
Software Incompatible
- Description: Software statuses do not match after firmware update.
- Action: Repeat firmware update with a valid file; contact installer if frequent.
-
Time/Date Lost
- Description: Inverter lost time, affecting yield data storage and event messages.
- Action: Correct the time settings under Settings > Time/date.
coolcept coolcept-x
3203/x 4003/x 4803x 5503x 5003 6003
stecagrid 8000 10000