{"product_id":"clenergy-sph-grid-pv-inverter-1-5-6-kw-accessory-kit","title":"Clenergy SPH Grid PV-Inverter | 1.5–6 kW | Accessory Kit","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-25\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-25\" data-turn-id-container=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-25\" data-testid=\"conversation-turn-12\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" data-dil-talvt-response-state=\"complete\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 [\u0026amp;\u0026gt;div:has([data-free-thinking-preview-answer=true])+:is(.text-message,.relative:has(\u0026gt;.text-message))]:-mt-2 grow\"\u003e\n\u003cdiv class=\"TzNmiG_container gap-4 [\u0026amp;\u0026gt;div:has([data-free-thinking-preview-answer=true])+:is(.text-message,.relative:has(\u0026gt;.text-message))]:-mt-2\" data-streaming-response-group=\"\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"1e95ecc0-6bcb-424b-b51d-7ae875062384\" data-markdown-talvt-message-id=\"1e95ecc0-6bcb-424b-b51d-7ae875062384\" dir=\"auto\" data-message-model-slug=\"gpt-5-6\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"fbskMG_root LR5Y_W_content markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch3 dir=\"auto\" data-start=\"63\" data-end=\"85\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"70\" data-end=\"85\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"86\" data-end=\"643\"\u003e\u003cstrong data-start=\"86\" data-end=\"111\"\u003eNew old-stock product\u003c\/strong\u003e, consisting of a set of components and accessories for \u003cstrong data-start=\"167\" data-end=\"200\"\u003eClenergy SPH Grid PV-Inverter\u003c\/strong\u003e photovoltaic inverters, including electrical connectors, connection components, mounting hardware, and installation and operation manual.\u003cbr\u003eClenergy's official documentation identifies the \u003cstrong data-start=\"388\" data-end=\"437\"\u003eSPH15 \/ SPH20 \/ SPH30 \/ SPH40 \/ SPH50 \/ SPH60\u003c\/strong\u003e family, with rated powers of \u003cstrong data-start=\"467\" data-end=\"521\"\u003e1500 W, 2000 W, 3000 W, 4000 W, 5000 W, and 6000 W\u003c\/strong\u003e respectively. The inverters are designed for grid connection and use \u003cstrong data-start=\"591\" data-end=\"610\"\u003etransformerless\u003c\/strong\u003e technology and \u003cstrong data-start=\"626\" data-end=\"634\"\u003eMPPT\u003c\/strong\u003e control.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"644\" data-end=\"674\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"651\" data-end=\"674\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"675\" data-end=\"1335\"\u003e\n\u003cli data-start=\"675\" data-end=\"731\"\u003e\n\u003cstrong data-start=\"677\" data-end=\"697\"\u003eInverter family:\u003c\/strong\u003e \u003cstrong data-start=\"698\" data-end=\"731\"\u003eClenergy SPH Grid PV-Inverter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"732\" data-end=\"806\"\u003e\n\u003cstrong data-start=\"734\" data-end=\"756\"\u003eDocumented models:\u003c\/strong\u003e \u003cstrong data-start=\"757\" data-end=\"806\"\u003eSPH15 \/ SPH20 \/ SPH30 \/ SPH40 \/ SPH50 \/ SPH60\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"807\" data-end=\"858\"\u003e\n\u003cstrong data-start=\"809\" data-end=\"827\"\u003ePower ratings:\u003c\/strong\u003e \u003cstrong data-start=\"828\" data-end=\"858\"\u003e1.5 \/ 2 \/ 3 \/ 4 \/ 5 \/ 6 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"859\" data-end=\"904\"\u003e\n\u003cstrong data-start=\"861\" data-end=\"885\"\u003eInverter technology:\u003c\/strong\u003e \u003cstrong data-start=\"886\" data-end=\"904\"\u003eGrid-Connected\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"905\" data-end=\"937\"\u003e\n\u003cstrong data-start=\"907\" data-end=\"925\"\u003eConfiguration:\u003c\/strong\u003e \u003cstrong data-start=\"926\" data-end=\"937\"\u003eOn-Grid\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"938\" data-end=\"962\"\u003e\n\u003cstrong data-start=\"940\" data-end=\"949\"\u003eType:\u003c\/strong\u003e Single-phase\u003c\/li\u003e\n\u003cli data-start=\"963\" data-end=\"1000\"\u003e\n\u003cstrong data-start=\"965\" data-end=\"980\"\u003eTechnology:\u003c\/strong\u003e \u003cstrong data-start=\"981\" data-end=\"1000\"\u003eTransformerless\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1001\" data-end=\"1054\"\u003e\n\u003cstrong data-start=\"1003\" data-end=\"1021\"\u003eMPPT function:\u003c\/strong\u003e \u003cstrong data-start=\"1022\" data-end=\"1054\"\u003eIntegrated into the inverter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1055\" data-end=\"1099\"\u003eOriginal installation and operation manual\u003c\/li\u003e\n\u003cli data-start=\"1100\" data-end=\"1138\"\u003eConnectors and connection components\u003c\/li\u003e\n\u003cli data-start=\"1139\" data-end=\"1158\"\u003eMounting hardware\u003c\/li\u003e\n\u003cli data-start=\"1159\" data-end=\"1335\"\u003eComponents\/accessories as shown in the photographs.\u003cbr\u003eClenergy's official documentation indicates a single-phase grid voltage of \u003cstrong data-start=\"1288\" data-end=\"1304\"\u003e220–250 V AC\u003c\/strong\u003e, 50\/60 Hz, for the SPH family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1336\" data-end=\"1361\"\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong data-start=\"1343\" data-end=\"1361\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1362\" data-end=\"1808\"\u003eThe kit is intended for installation, connection, and maintenance operations on inverters in the Clenergy SPH family.\u003cbr\u003eThe components provided allow the electrical connections of the inverter to be made or restored, including \u003cstrong data-start=\"1587\" data-end=\"1593\"\u003eAC\u003c\/strong\u003e and \u003cstrong data-start=\"1598\" data-end=\"1607\"\u003eDC\/PV\u003c\/strong\u003e connections, according to the model configuration.\u003cbr\u003eThe Clenergy manual specifies the use of \u003cstrong data-start=\"1700\" data-end=\"1728\"\u003eMC\/Multi-Contact or Tyco\u003c\/strong\u003e solar connectors for DC connections and dedicated connectors for the AC output.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"1809\" data-end=\"1841\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"1816\" data-end=\"1841\"\u003ePurpose and Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1842\" data-end=\"2273\"\u003eSPH inverters convert \u003cstrong data-start=\"1864\" data-end=\"1902\"\u003eDC energy from photovoltaic panels\u003c\/strong\u003e into \u003cstrong data-start=\"1908\" data-end=\"1921\"\u003eAC energy\u003c\/strong\u003e for feeding into the electrical grid.\u003cbr\u003eThe system uses the \u003cstrong data-start=\"1980\" data-end=\"2018\"\u003eMPPT – Maximum Peak Power Tracking\u003c\/strong\u003e function to optimize the operating point of the photovoltaic field and maximize the energy transferred to the grid.\u003cbr\u003eThe photographed kit is therefore intended for the inverter's installation\/connection section and does not constitute a complete inverter.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"2274\" data-end=\"2298\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"2281\" data-end=\"2298\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2299\" data-end=\"2342\"\u003eClenergy's official documentation includes:\u003c\/p\u003e\n\u003cul data-start=\"2343\" data-end=\"2604\"\u003e\n\u003cli data-start=\"2343\" data-end=\"2363\"\u003e\u003cstrong data-start=\"2345\" data-end=\"2363\"\u003eSPH15 – 1500 W\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2364\" data-end=\"2384\"\u003e\u003cstrong data-start=\"2366\" data-end=\"2384\"\u003eSPH20 – 2000 W\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2385\" data-end=\"2405\"\u003e\u003cstrong data-start=\"2387\" data-end=\"2405\"\u003eSPH30 – 3000 W\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2406\" data-end=\"2426\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2426\"\u003eSPH40 – 4000 W\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2427\" data-end=\"2447\"\u003e\u003cstrong data-start=\"2429\" data-end=\"2447\"\u003eSPH50 – 5000 W\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2448\" data-end=\"2506\"\u003e\n\u003cstrong data-start=\"2450\" data-end=\"2468\"\u003eSPH60 – 6000 W\u003c\/strong\u003e\u003cbr\u003eFor definitive compatibility, verify:\u003c\/li\u003e\n\u003cli data-start=\"2507\" data-end=\"2524\"\u003einverter model;\u003c\/li\u003e\n\u003cli data-start=\"2525\" data-end=\"2542\"\u003ecomponent code;\u003c\/li\u003e\n\u003cli data-start=\"2543\" data-end=\"2560\"\u003econnector type;\u003c\/li\u003e\n\u003cli data-start=\"2561\" data-end=\"2581\"\u003einverter revision;\u003c\/li\u003e\n\u003cli data-start=\"2582\" data-end=\"2604\"\u003eDC\/AC configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2605\" data-end=\"2640\"\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong data-start=\"2611\" data-end=\"2640\"\u003eSPH Family Technical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2641\" data-end=\"3107\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2641\" data-end=\"2682\"\u003e\n\u003ctr data-start=\"2641\" data-end=\"2682\"\u003e\n\u003cth data-start=\"2641\" data-end=\"2649\" data-col-size=\"xl\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"2649\" data-end=\"2663\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eRated Power\u003c\/th\u003e\n\u003cth data-start=\"2663\" data-end=\"2670\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eMPPT\u003c\/th\u003e\n\u003cth data-start=\"2670\" data-end=\"2682\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eMax. Voc\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2703\" data-end=\"3107\"\u003e\n\u003ctr data-start=\"2703\" data-end=\"2739\"\u003e\n\u003ctd data-start=\"2703\" data-end=\"2711\" data-col-size=\"xl\"\u003eSPH15\u003c\/td\u003e\n\u003ctd data-start=\"2711\" data-end=\"2721\" data-col-size=\"sm\"\u003e1,500 W\u003c\/td\u003e\n\u003ctd data-start=\"2721\" data-end=\"2727\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"2727\" data-end=\"2739\" data-col-size=\"sm\"\u003e550 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2740\" data-end=\"2776\"\u003e\n\u003ctd data-start=\"2740\" data-end=\"2748\" data-col-size=\"xl\"\u003eSPH20\u003c\/td\u003e\n\u003ctd data-start=\"2748\" data-end=\"2758\" data-col-size=\"sm\"\u003e2,000 W\u003c\/td\u003e\n\u003ctd data-start=\"2758\" data-end=\"2764\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"2764\" data-end=\"2776\" data-col-size=\"sm\"\u003e550 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2777\" data-end=\"2813\"\u003e\n\u003ctd data-start=\"2777\" data-end=\"2785\" data-col-size=\"xl\"\u003eSPH30\u003c\/td\u003e\n\u003ctd data-start=\"2785\" data-end=\"2795\" data-col-size=\"sm\"\u003e3,000 W\u003c\/td\u003e\n\u003ctd data-start=\"2795\" data-end=\"2801\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"2801\" data-end=\"2813\" data-col-size=\"sm\"\u003e550 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2814\" data-end=\"2850\"\u003e\n\u003ctd data-start=\"2814\" data-end=\"2822\" data-col-size=\"xl\"\u003eSPH40\u003c\/td\u003e\n\u003ctd data-start=\"2822\" data-end=\"2832\" data-col-size=\"sm\"\u003e4,000 W\u003c\/td\u003e\n\u003ctd data-start=\"2832\" data-end=\"2838\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"2838\" data-end=\"2850\" data-col-size=\"sm\"\u003e550 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2851\" data-end=\"2887\"\u003e\n\u003ctd data-start=\"2851\" data-end=\"2859\" data-col-size=\"xl\"\u003eSPH50\u003c\/td\u003e\n\u003ctd data-start=\"2859\" data-end=\"2869\" data-col-size=\"sm\"\u003e5,000 W\u003c\/td\u003e\n\u003ctd data-start=\"2869\" data-end=\"2875\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"2875\" data-end=\"2887\" data-col-size=\"sm\"\u003e600 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2888\" data-end=\"2924\"\u003e\n\u003ctd data-start=\"2888\" data-end=\"2896\" data-col-size=\"xl\"\u003eSPH60\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2896\" data-end=\"2906\"\u003e6,000 W\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2906\" data-end=\"2912\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2912\" data-end=\"2924\"\u003e600 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2925\" data-end=\"3107\"\u003e\n\u003ctd data-start=\"2925\" data-end=\"3107\" data-col-size=\"xl\"\u003eThe documented MPPT range is \u003cstrong data-start=\"2954\" data-end=\"2970\"\u003e150–500 V DC\u003c\/strong\u003e for models up to SPH40 and \u003cstrong data-start=\"2998\" data-end=\"3014\"\u003e150–600 V DC\u003c\/strong\u003e for SPH50\/SPH60. Maximum input current varies from \u003cstrong data-start=\"3066\" data-end=\"3083\"\u003e7.5 A to 30 A\u003c\/strong\u003e depending on the model.\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"auto\" data-start=\"3108\" data-end=\"3128\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"3115\" data-end=\"3128\"\u003eAC Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3129\" data-end=\"3514\"\u003e\n\u003cli data-start=\"3129\" data-end=\"3152\"\u003e\n\u003cstrong data-start=\"3131\" data-end=\"3140\"\u003eType:\u003c\/strong\u003e \u003cstrong data-start=\"3141\" data-end=\"3152\"\u003eOn-Grid\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3153\" data-end=\"3186\"\u003e\n\u003cstrong data-start=\"3155\" data-end=\"3173\"\u003eConfiguration:\u003c\/strong\u003e Single-phase\u003c\/li\u003e\n\u003cli data-start=\"3187\" data-end=\"3233\"\u003e\n\u003cstrong data-start=\"3189\" data-end=\"3216\"\u003eOperating grid voltage:\u003c\/strong\u003e \u003cstrong data-start=\"3217\" data-end=\"3233\"\u003e190–270 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3234\" data-end=\"3292\"\u003e\n\u003cstrong data-start=\"3236\" data-end=\"3261\"\u003eNominal grid voltage:\u003c\/strong\u003e approximately \u003cstrong data-start=\"3276\" data-end=\"3292\"\u003e220–250 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3293\" data-end=\"3354\"\u003e\n\u003cstrong data-start=\"3295\" data-end=\"3309\"\u003eFrequency:\u003c\/strong\u003e \u003cstrong data-start=\"3310\" data-end=\"3333\"\u003e47–53 Hz \/ 57–63 Hz\u003c\/strong\u003e, automatic selection\u003c\/li\u003e\n\u003cli data-start=\"3355\" data-end=\"3388\"\u003e\n\u003cstrong data-start=\"3357\" data-end=\"3380\"\u003eCurrent distortion:\u003c\/strong\u003e \u003cstrong data-start=\"3381\" data-end=\"3388\"\u003e\u0026lt;3%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3389\" data-end=\"3514\"\u003e\n\u003cstrong data-start=\"3391\" data-end=\"3408\"\u003ePower factor:\u003c\/strong\u003e \u003cstrong data-start=\"3409\" data-end=\"3418\"\u003e\u0026gt;0.99\u003c\/strong\u003e\u003cbr\u003eTherefore, this is \u003cstrong data-start=\"3438\" data-end=\"3477\"\u003enot a 230\/400 V three-phase product\u003c\/strong\u003e: the SPH family is \u003cstrong data-start=\"3497\" data-end=\"3513\"\u003esingle-phase\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3515\" data-end=\"3553\"\u003e\u003cspan role=\"text\"\u003e⚠️ \u003cstrong data-start=\"3522\" data-end=\"3553\"\u003eTypical Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3554\" data-end=\"3601\"\u003eThe kit components may be involved in cases of:\u003c\/p\u003e\n\u003cul data-start=\"3602\" data-end=\"4034\"\u003e\n\u003cli data-start=\"3602\" data-end=\"3627\"\u003eAC connection problems;\u003c\/li\u003e\n\u003cli data-start=\"3628\" data-end=\"3653\"\u003eDC connection problems;\u003c\/li\u003e\n\u003cli data-start=\"3654\" data-end=\"3689\"\u003edeteriorated electrical contacts;\u003c\/li\u003e\n\u003cli data-start=\"3690\" data-end=\"3711\"\u003edamaged connectors;\u003c\/li\u003e\n\u003cli data-start=\"3712\" data-end=\"3734\"\u003einsulation problems;\u003c\/li\u003e\n\u003cli data-start=\"3735\" data-end=\"3755\"\u003eDC circuit faults;\u003c\/li\u003e\n\u003cli data-start=\"3756\" data-end=\"3773\"\u003egrid anomalies;\u003c\/li\u003e\n\u003cli data-start=\"3774\" data-end=\"3798\"\u003ePV overvoltage errors;\u003c\/li\u003e\n\u003cli data-start=\"3799\" data-end=\"3817\"\u003eDC-Bus problems;\u003c\/li\u003e\n\u003cli data-start=\"3818\" data-end=\"4034\"\u003erelay or output-circuit faults.\u003cbr\u003eThe Clenergy manual lists, among others, \u003cstrong data-start=\"3893\" data-end=\"4033\"\u003eNo Utility, Grid Fault, PV Over Voltage, DC Bus High\/Low, Isolation Fault, Relay Failure, GFCI Fault, Device Fault, and Over Temperature\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4035\" data-end=\"4055\"\u003e\u003cspan role=\"text\"\u003e🔍 \u003cstrong data-start=\"4042\" data-end=\"4055\"\u003eDiagnosis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4056\" data-end=\"4096\"\u003eBefore installation, it is advisable to:\u003c\/p\u003e\n\u003cul data-start=\"4097\" data-end=\"4367\"\u003e\n\u003cli data-start=\"4097\" data-end=\"4133\"\u003eidentify the exact inverter model;\u003c\/li\u003e\n\u003cli data-start=\"4134\" data-end=\"4180\"\u003ecompare the connector with the original one;\u003c\/li\u003e\n\u003cli data-start=\"4181\" data-end=\"4215\"\u003everify polarity and connections;\u003c\/li\u003e\n\u003cli data-start=\"4216\" data-end=\"4267\"\u003echeck the mechanical condition of the components;\u003c\/li\u003e\n\u003cli data-start=\"4268\" data-end=\"4302\"\u003everify any identification codes;\u003c\/li\u003e\n\u003cli data-start=\"4303\" data-end=\"4367\"\u003euse the manual corresponding to the specific inverter version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4368\" data-end=\"4392\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"4376\" data-end=\"4392\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4393\" data-end=\"4629\"\u003e\n\u003cli data-start=\"4393\" data-end=\"4428\"\u003eClenergy SPH inverter maintenance\u003c\/li\u003e\n\u003cli data-start=\"4429\" data-end=\"4456\"\u003eSPH inverter installation\u003c\/li\u003e\n\u003cli data-start=\"4457\" data-end=\"4491\"\u003eRestoration of AC\/DC connections\u003c\/li\u003e\n\u003cli data-start=\"4492\" data-end=\"4530\"\u003eReplacement of connection components\u003c\/li\u003e\n\u003cli data-start=\"4531\" data-end=\"4576\"\u003eMaintenance of On-Grid photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"4577\" data-end=\"4629\"\u003eSpare parts for SPH inverters from \u003cstrong data-start=\"4614\" data-end=\"4629\"\u003e1.5 to 6 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4630\" data-end=\"4659\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"4638\" data-end=\"4659\"\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4660\" data-end=\"4854\"\u003e\u003cstrong data-start=\"4660\" data-end=\"4685\"\u003eNew old-stock product\u003c\/strong\u003e, packaged in bags as shown in the photographs.\u003cbr\u003eThe components appear unused and stored separately. The material is supplied in the condition visible in the photographs.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"4855\" data-end=\"4882\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"4862\" data-end=\"4882\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4883\" data-end=\"4929\"\u003eThe lot includes, as shown in the photographs:\u003c\/p\u003e\n\u003cul data-start=\"4930\" data-end=\"5220\"\u003e\n\u003cli data-start=\"4930\" data-end=\"4954\"\u003eelectrical components;\u003c\/li\u003e\n\u003cli data-start=\"4955\" data-end=\"4978\"\u003econnectors\/terminals;\u003c\/li\u003e\n\u003cli data-start=\"4979\" data-end=\"5003\"\u003econnection components;\u003c\/li\u003e\n\u003cli data-start=\"5004\" data-end=\"5035\"\u003ehardware and mounting screws;\u003c\/li\u003e\n\u003cli data-start=\"5036\" data-end=\"5063\"\u003einstallation accessories;\u003c\/li\u003e\n\u003cli data-start=\"5064\" data-end=\"5220\"\u003e\n\u003cstrong data-start=\"5066\" data-end=\"5099\"\u003eGrid PV-Inverter \/ SPH manual\u003c\/strong\u003e.\u003cbr\u003e\u003cstrong data-start=\"5101\" data-end=\"5220\"\u003eThe exact contents and compatibility of each individual component must be verified according to the inverter model.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"5221\" data-end=\"5239\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"5228\" data-end=\"5239\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5240\" data-end=\"5666\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"5240\" data-end=\"5368\"\u003eNew old-stock kit of accessories and components for Clenergy SPH Grid PV-Inverter photovoltaic inverters from 1500 to 6000 W\u003c\/strong\u003e, including installation manual, connectors, mounting hardware, and electrical components.\u003cbr\u003eClenergy's official documentation confirms the \u003cstrong data-start=\"5506\" data-end=\"5521\"\u003eSPH15–SPH60\u003c\/strong\u003e family, \u003cstrong data-start=\"5530\" data-end=\"5554\"\u003esingle-phase On-Grid\u003c\/strong\u003e architecture, \u003cstrong data-start=\"5569\" data-end=\"5588\"\u003etransformerless\u003c\/strong\u003e technology, MPPT operation, and the main electrical parameters of the series.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":54987867783501,"sku":null,"price":30.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7141.jpg?v=1791478133","url":"https:\/\/greenenergy-repair.com\/tr\/products\/clenergy-sph-grid-pv-inverter-1-5-6-kw-accessory-kit","provider":"Green Energy","version":"1.0","type":"link"}