{"product_id":"bisol-bmo-250-250w-photovoltaic-panels-with-integrated-tigo-mm-es050v300w-optimizers-tested-fully-functional-solar-module-lot","title":"BISOL BMO-250 250W Photovoltaic Panels with Integrated Tigo MM-ES050V300W Optimizers – Tested \u0026 Fully Functional Solar Module Lot","description":"\u003cp data-start=\"169\" data-end=\"345\"\u003eLot of \u003cstrong data-start=\"176\" data-end=\"217\"\u003e10 BISOL BMO-250 photovoltaic modules\u003c\/strong\u003e, each rated at \u003cstrong data-start=\"233\" data-end=\"241\"\u003e250W\u003c\/strong\u003e, complete with \u003cstrong data-start=\"257\" data-end=\"303\"\u003eTigo Energy MM-ES050V300W power optimizers\u003c\/strong\u003e installed on the rear side of the panels.\u003c\/p\u003e\n\u003cp data-start=\"347\" data-end=\"646\"\u003eAll modules have been carefully inspected, tested, and verified fully operational prior to sale. This solution is ideal for expanding existing photovoltaic systems, replacing damaged modules, off-grid installations, self-consumption projects, agricultural applications, and industrial solar systems.\u003c\/p\u003e\n\u003cp data-start=\"648\" data-end=\"1022\"\u003eThe integrated \u003cstrong data-start=\"663\" data-end=\"695\"\u003eTigo Energy power optimizers\u003c\/strong\u003e provide module-level monitoring and optimization, improving energy production in installations affected by partial shading, module mismatch, dirt accumulation, or varying operating conditions. By allowing each panel to operate independently at its maximum power point, overall system performance can be significantly improved.\u003c\/p\u003e\n\u003cp data-start=\"1024\" data-end=\"1067\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1067\"\u003eSold exclusively as a lot of 10 panels.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1069\" data-end=\"1072\"\u003e\n\u003ch2 data-start=\"1074\" data-end=\"1123\"\u003e⚙️ Photovoltaic Panel Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-start=\"1125\" data-end=\"1141\"\u003eManufacturer\u003c\/h3\u003e\n\u003cul data-start=\"1142\" data-end=\"1149\"\u003e\n\u003cli data-start=\"1142\" data-end=\"1149\"\u003eBISOL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1151\" data-end=\"1160\"\u003eModel\u003c\/h3\u003e\n\u003cul data-start=\"1161\" data-end=\"1170\"\u003e\n\u003cli data-start=\"1161\" data-end=\"1170\"\u003eBMO-250\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1172\" data-end=\"1191\"\u003eProduction Date\u003c\/h3\u003e\n\u003cul data-start=\"1192\" data-end=\"1201\"\u003e\n\u003cli data-start=\"1192\" data-end=\"1201\"\u003e05\/2014\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1203\" data-end=\"1225\"\u003eCell Configuration\u003c\/h3\u003e\n\u003cul data-start=\"1226\" data-end=\"1236\"\u003e\n\u003cli data-start=\"1226\" data-end=\"1236\"\u003e60 Cells\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1238\" data-end=\"1268\"\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1270\" data-end=\"1522\"\u003e\n\u003cli data-start=\"1270\" data-end=\"1297\"\u003eRated Power (Pmpp): 250 W\u003c\/li\u003e\n\u003cli data-start=\"1298\" data-end=\"1326\"\u003ePower Tolerance: +5 \/ -0 W\u003c\/li\u003e\n\u003cli data-start=\"1327\" data-end=\"1370\"\u003eVoltage at Maximum Power (Vmpp): 30.5 VDC\u003c\/li\u003e\n\u003cli data-start=\"1371\" data-end=\"1411\"\u003eCurrent at Maximum Power (Impp): 8.2 A\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1450\"\u003eOpen Circuit Voltage (Voc): 37.9 VDC\u003c\/li\u003e\n\u003cli data-start=\"1451\" data-end=\"1487\"\u003eShort Circuit Current (Isc): 8.8 A\u003c\/li\u003e\n\u003cli data-start=\"1488\" data-end=\"1522\"\u003eMaximum System Voltage: 1000 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1524\" data-end=\"1551\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1553\" data-end=\"1581\"\u003e\n\u003cli data-start=\"1553\" data-end=\"1581\"\u003eWeight: 18.5 kg per module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1583\" data-end=\"1601\"\u003eCertifications\u003c\/h3\u003e\n\u003cul data-start=\"1603\" data-end=\"1700\"\u003e\n\u003cli data-start=\"1603\" data-end=\"1619\"\u003eIEC 61215 Ed.2\u003c\/li\u003e\n\u003cli data-start=\"1620\" data-end=\"1636\"\u003eIEC 61730 Ed.1\u003c\/li\u003e\n\u003cli data-start=\"1637\" data-end=\"1649\"\u003eCE Marking\u003c\/li\u003e\n\u003cli data-start=\"1650\" data-end=\"1672\"\u003eMCS Approved Product\u003c\/li\u003e\n\u003cli data-start=\"1673\" data-end=\"1700\"\u003eBABT Certificate No. 8503\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1702\" data-end=\"1726\"\u003eManufacturing Origin\u003c\/h3\u003e\n\u003cul data-start=\"1728\" data-end=\"1756\"\u003e\n\u003cli data-start=\"1728\" data-end=\"1756\"\u003eMade in the European Union\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1758\" data-end=\"1761\"\u003e\n\u003ch2 data-start=\"1763\" data-end=\"1808\"\u003e⚙️ Tigo Optimizer Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-start=\"1810\" data-end=\"1826\"\u003eManufacturer\u003c\/h3\u003e\n\u003cul data-start=\"1827\" data-end=\"1840\"\u003e\n\u003cli data-start=\"1827\" data-end=\"1840\"\u003eTigo Energy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1842\" data-end=\"1851\"\u003eModel\u003c\/h3\u003e\n\u003cul data-start=\"1852\" data-end=\"1867\"\u003e\n\u003cli data-start=\"1852\" data-end=\"1867\"\u003eMM-ES050V300W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1869\" data-end=\"1877\"\u003eType\u003c\/h3\u003e\n\u003cul data-start=\"1879\" data-end=\"1909\"\u003e\n\u003cli data-start=\"1879\" data-end=\"1909\"\u003ePhotovoltaic Power Optimizer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1911\" data-end=\"1941\"\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1943\" data-end=\"2127\"\u003e\n\u003cli data-start=\"1943\" data-end=\"1975\"\u003eMaximum Supported Power: 300 W\u003c\/li\u003e\n\u003cli data-start=\"1976\" data-end=\"2013\"\u003eMaximum Input Voltage (Voc): 52 VDC\u003c\/li\u003e\n\u003cli data-start=\"2014\" data-end=\"2047\"\u003eMPPT Voltage Range: 16 – 48 VDC\u003c\/li\u003e\n\u003cli data-start=\"2048\" data-end=\"2089\"\u003eMaximum Continuous Input Current: 9.5 A\u003c\/li\u003e\n\u003cli data-start=\"2090\" data-end=\"2127\"\u003eMaximum Short-Circuit Current: 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2129\" data-end=\"2152\"\u003eAdditional Features\u003c\/h3\u003e\n\u003cul data-start=\"2154\" data-end=\"2271\"\u003e\n\u003cli data-start=\"2154\" data-end=\"2189\"\u003eIntegrated Wireless Communication\u003c\/li\u003e\n\u003cli data-start=\"2190\" data-end=\"2210\"\u003eFCC ID: XNNMD100AB\u003c\/li\u003e\n\u003cli data-start=\"2211\" data-end=\"2225\"\u003eCE Certified\u003c\/li\u003e\n\u003cli data-start=\"2226\" data-end=\"2241\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-start=\"2242\" data-end=\"2271\"\u003eDesigned in California, USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2273\" data-end=\"2276\"\u003e\n\u003ch2 data-start=\"2278\" data-end=\"2315\"\u003e🔧 Advantages of Tigo Optimization\u003c\/h2\u003e\n\u003cp data-start=\"2317\" data-end=\"2351\"\u003e✔ Module-level energy optimization\u003c\/p\u003e\n\u003cp data-start=\"2353\" data-end=\"2408\"\u003e✔ Increased production under partial shading conditions\u003c\/p\u003e\n\u003cp data-start=\"2410\" data-end=\"2451\"\u003e✔ Reduced losses caused by panel mismatch\u003c\/p\u003e\n\u003cp data-start=\"2453\" data-end=\"2488\"\u003e✔ Integrated wireless communication\u003c\/p\u003e\n\u003cp data-start=\"2490\" data-end=\"2526\"\u003e✔ Improved overall system efficiency\u003c\/p\u003e\n\u003cp data-start=\"2528\" data-end=\"2581\"\u003e✔ Enhanced flexibility for photovoltaic system design\u003c\/p\u003e\n\u003cp data-start=\"2583\" data-end=\"2628\"\u003e✔ Better performance in complex installations\u003c\/p\u003e\n\u003chr data-start=\"2630\" data-end=\"2633\"\u003e\n\u003ch2 data-start=\"2635\" data-end=\"2661\"\u003e☀️ Typical Applications\u003c\/h2\u003e\n\u003cp data-start=\"2663\" data-end=\"2673\"\u003eIdeal for:\u003c\/p\u003e\n\u003cul data-start=\"2675\" data-end=\"2944\"\u003e\n\u003cli data-start=\"2675\" data-end=\"2709\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"2710\" data-end=\"2742\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-start=\"2743\" data-end=\"2772\"\u003eAgricultural solar projects\u003c\/li\u003e\n\u003cli data-start=\"2773\" data-end=\"2805\"\u003eIndustrial photovoltaic plants\u003c\/li\u003e\n\u003cli data-start=\"2806\" data-end=\"2824\"\u003eOff-grid systems\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2857\"\u003eSelf-consumption installations\u003c\/li\u003e\n\u003cli data-start=\"2858\" data-end=\"2892\"\u003eExpansion of existing PV systems\u003c\/li\u003e\n\u003cli data-start=\"2893\" data-end=\"2944\"\u003eReplacement of damaged or underperforming modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2946\" data-end=\"2949\"\u003e\n\u003ch2 data-start=\"2951\" data-end=\"2974\"\u003e📦 Product Condition\u003c\/h2\u003e\n\u003cul data-start=\"2976\" data-end=\"3161\"\u003e\n\u003cli data-start=\"2976\" data-end=\"2982\"\u003eUsed\u003c\/li\u003e\n\u003cli data-start=\"2983\" data-end=\"3012\"\u003eTested and fully functional\u003c\/li\u003e\n\u003cli data-start=\"3013\" data-end=\"3037\"\u003eVerified prior to sale\u003c\/li\u003e\n\u003cli data-start=\"3038\" data-end=\"3078\"\u003eComplete with installed Tigo optimizer\u003c\/li\u003e\n\u003cli data-start=\"3079\" data-end=\"3118\"\u003eNormal cosmetic signs of previous use\u003c\/li\u003e\n\u003cli data-start=\"3119\" data-end=\"3161\"\u003eSold exactly as shown in the photographs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3163\" data-end=\"3166\"\u003e\n\u003ch2 data-start=\"3168\" data-end=\"3191\"\u003e📊 Lot Configuration\u003c\/h2\u003e\n\u003ch3 data-start=\"3193\" data-end=\"3213\"\u003eLot of 10 Panels\u003c\/h3\u003e\n\u003cul data-start=\"3215\" data-end=\"3340\"\u003e\n\u003cli data-start=\"3215\" data-end=\"3256\"\u003e10 × BISOL BMO-250 photovoltaic modules\u003c\/li\u003e\n\u003cli data-start=\"3257\" data-end=\"3299\"\u003e10 × Tigo MM-ES050V300W power optimizers\u003c\/li\u003e\n\u003cli data-start=\"3300\" data-end=\"3340\"\u003eTotal Installed Capacity: \u003cstrong data-start=\"3328\" data-end=\"3340\"\u003e2.50 kWp\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3342\" data-end=\"3345\"\u003e\n\u003ch2 data-start=\"3347\" data-end=\"3361\"\u003e🚚 Shipping\u003c\/h2\u003e\n\u003ch3 data-start=\"3363\" data-end=\"3380\"\u003eShipping Cost\u003c\/h3\u003e\n\u003cp data-start=\"3382\" data-end=\"3393\"\u003e\u003cstrong data-start=\"3382\" data-end=\"3393\"\u003e€120.00\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3395\" data-end=\"3405\"\u003eValid for:\u003c\/p\u003e\n\u003cul data-start=\"3407\" data-end=\"3425\"\u003e\n\u003cli data-start=\"3407\" data-end=\"3425\"\u003eLot of 10 Panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3427\" data-end=\"3561\"\u003eShipping is carried out by a specialized freight carrier using \u003cstrong data-start=\"3490\" data-end=\"3514\"\u003epalletized packaging\u003c\/strong\u003e to ensure maximum protection during transport.\u003c\/p\u003e\n\u003chr data-start=\"3563\" data-end=\"3566\"\u003e\n\u003ch2 data-start=\"3568\" data-end=\"3585\"\u003e✅ Key Benefits\u003c\/h2\u003e\n\u003cp data-start=\"3587\" data-end=\"3629\"\u003e✔ European-made BISOL photovoltaic modules\u003c\/p\u003e\n\u003cp data-start=\"3631\" data-end=\"3674\"\u003e✔ Integrated Tigo module-level optimization\u003c\/p\u003e\n\u003cp data-start=\"3676\" data-end=\"3716\"\u003e✔ Fully tested and operational equipment\u003c\/p\u003e\n\u003cp data-start=\"3718\" data-end=\"3771\"\u003e✔ Ideal for system expansion and replacement projects\u003c\/p\u003e\n\u003cp data-start=\"3773\" data-end=\"3820\"\u003e✔ Improved performance under shading conditions\u003c\/p\u003e\n\u003cp data-start=\"3822\" data-end=\"3871\"\u003e✔ Reduced energy losses caused by module mismatch\u003c\/p\u003e\n\u003cp data-start=\"3873\" data-end=\"3916\"\u003e✔ Professional-grade photovoltaic equipment\u003c\/p\u003e\n\u003cp data-start=\"3918\" data-end=\"3952\"\u003e✔ Ready for immediate installation\u003c\/p\u003e\n\u003chr data-start=\"3954\" data-end=\"3957\"\u003e\n\u003ch2 data-start=\"3959\" data-end=\"3972\"\u003e🟢 Summary\u003c\/h2\u003e\n\u003cp data-start=\"3974\" data-end=\"4571\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThis lot includes \u003cstrong data-start=\"3992\" data-end=\"4051\"\u003e10 BISOL BMO-250 photovoltaic panels rated at 250W each\u003c\/strong\u003e, complete with \u003cstrong data-start=\"4067\" data-end=\"4127\"\u003eTigo Energy MM-ES050V300W power optimizers pre-installed\u003c\/strong\u003e. All modules have been tested and verified fully operational. With a total installed capacity of \u003cstrong data-start=\"4225\" data-end=\"4237\"\u003e2.50 kWp\u003c\/strong\u003e, this package is an excellent solution for residential, commercial, agricultural, and off-grid photovoltaic installations requiring module-level optimization and improved energy production. The equipment originates from a professionally decommissioned solar installation, has been thoroughly tested, and is ready for immediate reuse.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":54120550793549,"sku":null,"price":500.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/41d6dfd9-4bc7-46cd-a832-5cb3f5031bfa.png?v=1781625784","url":"https:\/\/greenenergy-repair.com\/tr\/products\/bisol-bmo-250-250w-photovoltaic-panels-with-integrated-tigo-mm-es050v300w-optimizers-tested-fully-functional-solar-module-lot","provider":"Green Energy","version":"1.0","type":"link"}