{"product_id":"kostal-piko-10-1-dc-filter-board-100-532-34","title":"KOSTAL PIKO 10.1 | DC Filter Board | 100 532 34","description":"\u003ch3 dir=\"auto\" data-start=\"54\" data-end=\"76\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"61\" data-end=\"76\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"77\" data-end=\"539\"\u003e\u003cstrong data-start=\"77\" data-end=\"93\"\u003eUsed product\u003c\/strong\u003e – Original \u003cstrong data-start=\"105\" data-end=\"115\"\u003eKOSTAL\u003c\/strong\u003e electronic board for \u003cstrong data-start=\"137\" data-end=\"150\"\u003ePIKO 10.1\u003c\/strong\u003e photovoltaic inverters, identified by the \u003cstrong data-start=\"193\" data-end=\"212\"\u003eDC-Anschluss-LP\u003c\/strong\u003e marking and code \u003cstrong data-start=\"230\" data-end=\"244\"\u003e100 532 34\u003c\/strong\u003e. The board is the connection and filtering module for the inverter's DC section and integrates three separate filter circuits, with inductors, capacitors, and noise-suppression components.\u003cbr\u003eCode \u003cstrong data-start=\"439\" data-end=\"453\"\u003e100 532 34\u003c\/strong\u003e is commercially associated with the \u003cstrong data-start=\"490\" data-end=\"538\"\u003eKOSTAL PIKO 10.1 DC Filter \/ DC-Anschluss-LP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"540\" data-end=\"570\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"547\" data-end=\"570\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"571\" data-end=\"1016\"\u003e\n\u003cli data-start=\"571\" data-end=\"597\"\u003e\n\u003cstrong data-start=\"573\" data-end=\"590\"\u003eManufacturer:\u003c\/strong\u003e KOSTAL\u003c\/li\u003e\n\u003cli data-start=\"598\" data-end=\"643\"\u003e\n\u003cstrong data-start=\"600\" data-end=\"616\"\u003eApplication:\u003c\/strong\u003e PIKO photovoltaic inverter\u003c\/li\u003e\n\u003cli data-start=\"644\" data-end=\"681\"\u003e\n\u003cstrong data-start=\"646\" data-end=\"667\"\u003eAssociated model:\u003c\/strong\u003e \u003cstrong data-start=\"668\" data-end=\"681\"\u003ePIKO 10.1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"682\" data-end=\"712\"\u003e\n\u003cstrong data-start=\"684\" data-end=\"697\"\u003ePCB code:\u003c\/strong\u003e \u003cstrong data-start=\"698\" data-end=\"712\"\u003e100 532 34\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"713\" data-end=\"763\"\u003e\n\u003cstrong data-start=\"715\" data-end=\"731\"\u003eDesignation:\u003c\/strong\u003e \u003cstrong data-start=\"732\" data-end=\"763\"\u003eDC-Anschluss-LP \/ DC Filter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"764\" data-end=\"794\"\u003eBoard for the \u003cstrong data-start=\"780\" data-end=\"786\"\u003eDC\u003c\/strong\u003e section\u003c\/li\u003e\n\u003cli data-start=\"795\" data-end=\"827\"\u003eThree separate filter circuits\u003c\/li\u003e\n\u003cli data-start=\"828\" data-end=\"861\"\u003eFilter inductors \u003cstrong data-start=\"847\" data-end=\"861\"\u003eL1, L2, L3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"862\" data-end=\"906\"\u003eFilm capacitors and suppression components\u003c\/li\u003e\n\u003cli data-start=\"907\" data-end=\"928\"\u003eDC power connectors\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"966\"\u003eAuxiliary connection via flat cable\u003c\/li\u003e\n\u003cli data-start=\"967\" data-end=\"1016\"\u003ePower PCB with traces sized for the DC section.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1017\" data-end=\"1042\"\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong data-start=\"1024\" data-end=\"1042\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1043\" data-end=\"1329\"\u003e\n\u003cli data-start=\"1043\" data-end=\"1084\"\u003eConnection of the inverter's DC section\u003c\/li\u003e\n\u003cli data-start=\"1085\" data-end=\"1151\"\u003eFiltering of electrical interference generated during conversion\u003c\/li\u003e\n\u003cli data-start=\"1152\" data-end=\"1215\"\u003eReduction of high-frequency components present on the DC line\u003c\/li\u003e\n\u003cli data-start=\"1216\" data-end=\"1270\"\u003eSeparation and filtering of the three input circuits\u003c\/li\u003e\n\u003cli data-start=\"1271\" data-end=\"1329\"\u003eTransfer of DC energy to the subsequent inverter stages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1330\" data-end=\"1362\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"1337\" data-end=\"1362\"\u003ePurpose and Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1363\" data-end=\"1770\"\u003eThe board is located in the \u003cstrong data-start=\"1391\" data-end=\"1411\"\u003eDC input section\u003c\/strong\u003e of the KOSTAL PIKO 10.1.\u003cbr\u003eThe three sections visible on the PCB use inductors and capacitors to provide electrical filtering. The filter helps limit conducted interference and high-frequency components, improving and stabilizing operation of the conversion stage.\u003cbr\u003eIt is not a control or communication board: it is a \u003cstrong data-start=\"1727\" data-end=\"1769\"\u003epower\/passive module of the DC section\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"1771\" data-end=\"1795\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"1778\" data-end=\"1795\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1796\" data-end=\"1859\"\u003eThe exact documented correspondence for code \u003cstrong data-start=\"1841\" data-end=\"1855\"\u003e100 532 34\u003c\/strong\u003e is:\u003c\/p\u003e\n\u003cul data-start=\"1860\" data-end=\"2212\"\u003e\n\u003cli data-start=\"1860\" data-end=\"1882\"\u003e\u003cstrong data-start=\"1862\" data-end=\"1882\"\u003eKOSTAL PIKO 10.1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1883\" data-end=\"2212\"\u003e\n\u003cstrong data-start=\"1885\" data-end=\"1902\"\u003ePIKO 10.1 DCS\u003c\/strong\u003e\u003cbr\u003eFor replacement, it is nevertheless essential to verify \u003cstrong data-start=\"1959\" data-end=\"2027\"\u003ePCB code, revision, connector layout, and inverter configuration\u003c\/strong\u003e, as other DC boards with different codes are present within the PIKO family. The spare-parts market distinguishes this board from the \u003cstrong data-start=\"2162\" data-end=\"2190\"\u003eDC Trennstelle\/DC Switch\u003c\/strong\u003e assembly of the PIKO.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2213\" data-end=\"2251\"\u003e\u003cspan role=\"text\"\u003e⚠️ \u003cstrong data-start=\"2220\" data-end=\"2251\"\u003eTypical Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2252\" data-end=\"2309\"\u003eAn anomaly in the DC filter board may be associated with:\u003c\/p\u003e\n\u003cul data-start=\"2310\" data-end=\"2720\"\u003e\n\u003cli data-start=\"2310\" data-end=\"2337\"\u003einverter failing to start\u003c\/li\u003e\n\u003cli data-start=\"2338\" data-end=\"2373\"\u003eanomalies in the DC input section\u003c\/li\u003e\n\u003cli data-start=\"2374\" data-end=\"2395\"\u003eprotection tripping\u003c\/li\u003e\n\u003cli data-start=\"2396\" data-end=\"2442\"\u003eloss or reduction of power from the PV field\u003c\/li\u003e\n\u003cli data-start=\"2443\" data-end=\"2465\"\u003eabnormal DC voltages\u003c\/li\u003e\n\u003cli data-start=\"2466\" data-end=\"2505\"\u003enoise or overheating of the inductors\u003c\/li\u003e\n\u003cli data-start=\"2506\" data-end=\"2538\"\u003edamaged or degraded capacitors\u003c\/li\u003e\n\u003cli data-start=\"2539\" data-end=\"2720\"\u003eburn marks on traces or terminals.\u003cbr\u003eThese symptoms \u003cstrong data-start=\"2591\" data-end=\"2644\"\u003edo not automatically identify the board as faulty\u003c\/strong\u003e: the PV field, DC wiring, connectors, and power stage must also be checked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2721\" data-end=\"2758\"\u003e\u003cspan role=\"text\"\u003e🚨 \u003cstrong data-start=\"2728\" data-end=\"2758\"\u003ePossible Associated Errors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2759\" data-end=\"2997\"\u003eAny errors related to \u003cstrong data-start=\"2781\" data-end=\"2837\"\u003eDC voltage, insulation, PV input, or the power stage\u003c\/strong\u003e may have multiple causes. The filter board should therefore be considered one of the possible components to be checked, and not the certain cause of the error.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"2998\" data-end=\"3018\"\u003e\u003cspan role=\"text\"\u003e🔍 \u003cstrong data-start=\"3005\" data-end=\"3018\"\u003eDiagnosis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3019\" data-end=\"3044\"\u003eVerification may include:\u003c\/p\u003e\n\u003col data-start=\"3045\" data-end=\"3386\"\u003e\n\u003cli data-start=\"3045\" data-end=\"3094\"\u003evisual inspection of capacitors and inductors;\u003c\/li\u003e\n\u003cli data-start=\"3095\" data-end=\"3124\"\u003echecking the DC terminals;\u003c\/li\u003e\n\u003cli data-start=\"3125\" data-end=\"3156\"\u003echecking for damaged traces;\u003c\/li\u003e\n\u003cli data-start=\"3157\" data-end=\"3228\"\u003echecking for short circuits or leakage between the various circuits;\u003c\/li\u003e\n\u003cli data-start=\"3229\" data-end=\"3257\"\u003echecking inductors L1–L3;\u003c\/li\u003e\n\u003cli data-start=\"3258\" data-end=\"3292\"\u003echecking the filter capacitors;\u003c\/li\u003e\n\u003cli data-start=\"3293\" data-end=\"3338\"\u003echecking the flat cable and its connector;\u003c\/li\u003e\n\u003cli data-start=\"3339\" data-end=\"3386\"\u003etesting the board installed in the inverter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 dir=\"auto\" data-start=\"3387\" data-end=\"3433\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3395\" data-end=\"3433\"\u003eCommon Services in Case of Failure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3434\" data-end=\"3657\"\u003e\n\u003cli data-start=\"3434\" data-end=\"3456\"\u003eDC board diagnostics\u003c\/li\u003e\n\u003cli data-start=\"3457\" data-end=\"3477\"\u003eContinuity testing\u003c\/li\u003e\n\u003cli data-start=\"3478\" data-end=\"3500\"\u003eCapacitor inspection\u003c\/li\u003e\n\u003cli data-start=\"3501\" data-end=\"3522\"\u003eInductor inspection\u003c\/li\u003e\n\u003cli data-start=\"3523\" data-end=\"3559\"\u003eChecking and restoring connections\u003c\/li\u003e\n\u003cli data-start=\"3560\" data-end=\"3588\"\u003eComplete board replacement\u003c\/li\u003e\n\u003cli data-start=\"3589\" data-end=\"3657\"\u003eRecovery as an original spare part from a decommissioned inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3658\" data-end=\"3682\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3666\" data-end=\"3682\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3683\" data-end=\"3696\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul data-start=\"3697\" data-end=\"3869\"\u003e\n\u003cli data-start=\"3697\" data-end=\"3731\"\u003e\n\u003cstrong data-start=\"3699\" data-end=\"3719\"\u003eKOSTAL PIKO 10.1\u003c\/strong\u003e maintenance\u003c\/li\u003e\n\u003cli data-start=\"3732\" data-end=\"3754\"\u003ePIKO inverter repair\u003c\/li\u003e\n\u003cli data-start=\"3755\" data-end=\"3784\"\u003eDC filter board replacement\u003c\/li\u003e\n\u003cli data-start=\"3785\" data-end=\"3820\"\u003einverter recovery for spare parts\u003c\/li\u003e\n\u003cli data-start=\"3821\" data-end=\"3869\"\u003erestoration of the photovoltaic input section.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3870\" data-end=\"3897\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"3877\" data-end=\"3897\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3898\" data-end=\"4027\"\u003e\n\u003cli data-start=\"3898\" data-end=\"3953\"\u003e1 × \u003cstrong data-start=\"3904\" data-end=\"3947\"\u003eKOSTAL PIKO DC Filter \/ DC-Anschluss-LP\u003c\/strong\u003e board\u003c\/li\u003e\n\u003cli data-start=\"3954\" data-end=\"3975\"\u003eCode \u003cstrong data-start=\"3961\" data-end=\"3975\"\u003e100 532 34\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3976\" data-end=\"4027\"\u003eFlat connection cable as shown in the photograph.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4028\" data-end=\"4046\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"4035\" data-end=\"4046\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4047\" data-end=\"4599\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"4047\" data-end=\"4100\"\u003eKOSTAL PIKO 10.1 DC filter board, code 100 532 34\u003c\/strong\u003e, used in the inverter's DC input section. It integrates three filtering circuits with inductors and capacitors and is identified on the spare-parts market as \u003cstrong data-start=\"4259\" data-end=\"4311\"\u003ePIKO 10.1 DC Filter \/ DC-Anschluss-LP 100 532 34\u003c\/strong\u003e. \u003cbr\u003e\u003cstrong data-start=\"4398\" data-end=\"4414\"\u003eSafety Note:\u003c\/strong\u003e The board belongs to the inverter's DC power section; before any intervention, the equipment must be completely disconnected and the absence of voltage verified by qualified personnel.\u003c\/p\u003e","brand":"Kostal Piko","offers":[{"title":"Default Title","offer_id":54976272367949,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7097.jpg?v=1791381857","url":"https:\/\/greenenergy-repair.com\/ru\/products\/kostal-piko-10-1-dc-filter-board-100-532-34","provider":"Green Energy","version":"1.0","type":"link"}