{"product_id":"fans-tech-230-vac-centrifugal-fan-109-w","title":"Fans-tech | 230 VAC Centrifugal Fan | 109 W","description":"\u003ch3 dir=\"auto\" data-start=\"50\" data-end=\"72\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"57\" data-end=\"72\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"73\" data-end=\"449\"\u003e\u003cstrong data-start=\"73\" data-end=\"90\"\u003eUsed product.\u003c\/strong\u003e\u003cbr\u003eIndustrial \u003cstrong data-start=\"102\" data-end=\"137\"\u003esingle-phase AC centrifugal fan\u003c\/strong\u003e \u003cstrong\u003eFans-tech\u003c\/strong\u003e powered at \u003cstrong data-start=\"149\" data-end=\"159\"\u003e230 V~\u003c\/strong\u003e, intended for ventilation and cooling of electrical and electronic equipment, panels, conversion systems, industrial equipment, and HVAC systems. The visible construction is that of a compact centrifugal fan with a \u003cstrong data-start=\"375\" data-end=\"407\"\u003esingle-phase capacitor motor\u003c\/strong\u003e, metal support, and pre-installed wiring.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"450\" data-end=\"485\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"457\" data-end=\"485\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"486\" data-end=\"559\"\u003eAccording to the \u003cstrong data-start=\"503\" data-end=\"525\"\u003eoriginal nameplate\u003c\/strong\u003e, the following data are provided:\u003c\/p\u003e\n\u003cul data-start=\"560\" data-end=\"1368\"\u003e\n\u003cli data-start=\"560\" data-end=\"589\"\u003e\n\u003cstrong data-start=\"562\" data-end=\"579\"\u003ePower supply:\u003c\/strong\u003e 230 V~ AC\u003c\/li\u003e\n\u003cli data-start=\"590\" data-end=\"619\"\u003e\n\u003cstrong data-start=\"592\" data-end=\"606\"\u003eFrequency:\u003c\/strong\u003e \u003cstrong data-start=\"607\" data-end=\"619\"\u003e50\/60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"620\" data-end=\"654\"\u003e\n\u003cstrong data-start=\"622\" data-end=\"634\"\u003eCurrent:\u003c\/strong\u003e \u003cstrong data-start=\"635\" data-end=\"654\"\u003e0.39 A \/ 0.48 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"655\" data-end=\"684\"\u003e\n\u003cstrong data-start=\"657\" data-end=\"667\"\u003ePower:\u003c\/strong\u003e \u003cstrong data-start=\"668\" data-end=\"684\"\u003e87 W \/ 109 W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"685\" data-end=\"717\"\u003e\n\u003cstrong data-start=\"687\" data-end=\"697\"\u003eSpeed:\u003c\/strong\u003e \u003cstrong data-start=\"698\" data-end=\"717\"\u003e2600 \/ 2800 rpm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"718\" data-end=\"751\"\u003e\n\u003cstrong data-start=\"720\" data-end=\"734\"\u003eCapacitor:\u003c\/strong\u003e \u003cstrong data-start=\"735\" data-end=\"751\"\u003e3 µF – 450 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"752\" data-end=\"781\"\u003e\n\u003cstrong data-start=\"754\" data-end=\"775\"\u003eInsulation class:\u003c\/strong\u003e \u003cstrong data-start=\"776\" data-end=\"781\"\u003eF\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"782\" data-end=\"814\"\u003e\n\u003cstrong data-start=\"784\" data-end=\"807\"\u003eThermal protection:\u003c\/strong\u003e \u003cstrong data-start=\"808\" data-end=\"814\"\u003eTP\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"815\" data-end=\"852\"\u003e\n\u003cstrong data-start=\"817\" data-end=\"833\"\u003eConnections:\u003c\/strong\u003e \u003cstrong data-start=\"834\" data-end=\"852\"\u003eL \/ Z \/ N \/ PE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"890\"\u003e\n\u003cstrong data-start=\"855\" data-end=\"862\"\u003ePE:\u003c\/strong\u003e protective earth connection\u003c\/li\u003e\n\u003cli data-start=\"891\" data-end=\"1368\"\u003e\n\u003cstrong data-start=\"893\" data-end=\"900\"\u003eCE:\u003c\/strong\u003e marking visible on the nameplate\u003cbr\u003eThe values refer respectively to operation at \u003cstrong data-start=\"980\" data-end=\"997\"\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e: 87 W and 2600 rpm at 50 Hz, 109 W and 2800 rpm at 60 Hz.\u003cbr\u003eThe electrical diagram printed on the fan indicates the \u003cstrong data-start=\"1112\" data-end=\"1121\"\u003eL–Z–N\u003c\/strong\u003e connection, with the \u003cstrong data-start=\"1143\" data-end=\"1161\"\u003e3 µF capacitor\u003c\/strong\u003e connected according to the diagram between terminal \u003cstrong data-start=\"1214\" data-end=\"1219\"\u003eZ\u003c\/strong\u003e and \u003cstrong data-start=\"1224\" data-end=\"1229\"\u003eN\u003c\/strong\u003e, together with the \u003cstrong data-start=\"1249\" data-end=\"1255\"\u003ePE\u003c\/strong\u003e conductor for protective grounding. The integrated \u003cstrong data-start=\"1307\" data-end=\"1313\"\u003eTP\u003c\/strong\u003e thermal protection is also shown in the motor circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1369\" data-end=\"1412\"\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong data-start=\"1375\" data-end=\"1412\"\u003eFunction in the Electrical System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1413\" data-end=\"1995\"\u003eThis is a \u003cstrong data-start=\"1423\" data-end=\"1442\"\u003ecentrifugal fan\u003c\/strong\u003e, not a conventional axial fan: air is drawn into the central area of the impeller and accelerated radially toward the outlet.\u003cbr\u003eThe centrifugal configuration is particularly suitable when \u003cstrong data-start=\"1629\" data-end=\"1673\"\u003ehigher static pressure than an axial fan\u003c\/strong\u003e is required, for example in systems with ducting, grilles, filters, heat exchangers, or airflow passages with a certain resistance.\u003cbr\u003eFans-tech's official documentation identifies its backward-curved centrifugal fans as devices intended for ventilation, air conditioning, air transport, and cooling of industrial equipment.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"1996\" data-end=\"2036\"\u003e\u003cspan role=\"text\"\u003e🏭 \u003cstrong data-start=\"2003\" data-end=\"2036\"\u003eConstruction and Installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2037\" data-end=\"2519\"\u003eThe photographed fan features a \u003cstrong data-start=\"2069\" data-end=\"2096\"\u003emetal support structure\u003c\/strong\u003e, central motor, and wiring with conductors for power supply and protective grounding. The motor uses a \u003cstrong data-start=\"2200\" data-end=\"2236\"\u003e3 µF \/ 450 V permanent capacitor\u003c\/strong\u003e and incorporates \u003cstrong data-start=\"2254\" data-end=\"2279\"\u003eTP thermal protection\u003c\/strong\u003e, intended to interrupt motor protection in the event of abnormal thermal conditions.\u003cbr\u003e\u003cstrong data-start=\"2365\" data-end=\"2376\"\u003eClass F\u003c\/strong\u003e identifies the thermal insulation level of the motor winding.\u003cbr\u003eThe \u003cstrong data-start=\"2443\" data-end=\"2498\"\u003ePE connection must be connected to protective earth\u003c\/strong\u003e during installation.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"2520\" data-end=\"2543\"\u003e\u003cspan role=\"text\"\u003e🌐 \u003cstrong data-start=\"2527\" data-end=\"2543\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2544\" data-end=\"2617\"\u003eSuitable, depending on mechanical compatibility and operating point, for:\u003c\/p\u003e\n\u003cul data-start=\"2618\" data-end=\"3068\"\u003e\n\u003cli data-start=\"2618\" data-end=\"2666\"\u003e\n\u003cstrong data-start=\"2620\" data-end=\"2665\"\u003eelectrical panels and industrial cabinets\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-start=\"2667\" data-end=\"2712\"\u003e\n\u003cstrong data-start=\"2669\" data-end=\"2711\"\u003einverter and converter cooling systems\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-start=\"2713\" data-end=\"2742\"\u003epower electronic equipment;\u003c\/li\u003e\n\u003cli data-start=\"2743\" data-end=\"2774\"\u003eHVAC and ventilation systems;\u003c\/li\u003e\n\u003cli data-start=\"2775\" data-end=\"2798\"\u003eindustrial equipment;\u003c\/li\u003e\n\u003cli data-start=\"2799\" data-end=\"2830\"\u003esystems with \u003cstrong data-start=\"2814\" data-end=\"2829\"\u003eair ducting\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-start=\"2831\" data-end=\"3068\"\u003ecooling of components requiring greater pressure than axial ventilation.\u003cbr\u003eFans-tech also indicates the use of its ventilation solutions in the \u003cstrong data-start=\"2975\" data-end=\"2996\"\u003ePower Electronics\u003c\/strong\u003e sector to promote thermal dissipation and stability of power equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3069\" data-end=\"3109\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"3077\" data-end=\"3109\"\u003eSafety and Product Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3110\" data-end=\"3686\"\u003e\u003cstrong data-start=\"3110\" data-end=\"3126\"\u003eUsed product\u003c\/strong\u003e, with normal signs of use on the metal structure. The wiring and protective earth conductor are present as shown in the photographs.\u003cbr\u003eAs this is a \u003cstrong data-start=\"3273\" data-end=\"3284\"\u003e230 VAC\u003c\/strong\u003e powered device, installation and testing must be carried out with the power disconnected and by qualified personnel. The \u003cstrong data-start=\"3406\" data-end=\"3432\"\u003e3 µF \/ 450 V capacitor\u003c\/strong\u003e may retain an electrical charge even after power has been disconnected: verify the absence of voltage before carrying out any work.\u003cbr\u003eThe fan must be installed with \u003cstrong data-start=\"3596\" data-end=\"3619\"\u003eproper PE grounding\u003c\/strong\u003e, following the original electrical diagram shown on the nameplate.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"3687\" data-end=\"3714\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"3694\" data-end=\"3714\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3715\" data-end=\"3823\"\u003e\n\u003cli data-start=\"3715\" data-end=\"3750\"\u003e\n\u003cstrong data-start=\"3717\" data-end=\"3749\"\u003e1 × 230 V AC centrifugal fan\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-start=\"3751\" data-end=\"3768\"\u003evisible wiring;\u003c\/li\u003e\n\u003cli data-start=\"3769\" data-end=\"3823\"\u003emetal structure\/support as shown in the photographs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3824\" data-end=\"3852\"\u003e\u003cspan role=\"text\"\u003e🚀 \u003cstrong data-start=\"3831\" data-end=\"3852\"\u003eFinal Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3853\" data-end=\"4468\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3853\" data-end=\"3866\"\u003eFans-tech\u003c\/strong\u003e centrifugal fan for industrial applications, with \u003cstrong data-start=\"3917\" data-end=\"3948\"\u003e230 V AC single-phase motor\u003c\/strong\u003e, \u003cstrong data-start=\"3950\" data-end=\"3962\"\u003e50\/60 Hz\u003c\/strong\u003e operation, \u003cstrong data-start=\"3974\" data-end=\"3986\"\u003e87\/109 W\u003c\/strong\u003e power, \u003cstrong data-start=\"3994\" data-end=\"4009\"\u003e0.39\/0.48 A\u003c\/strong\u003e current, and \u003cstrong data-start=\"4023\" data-end=\"4040\"\u003e2600\/2800 rpm\u003c\/strong\u003e speed. The motor uses a \u003cstrong data-start=\"4065\" data-end=\"4091\"\u003e3 µF \/ 450 V capacitor\u003c\/strong\u003e, features \u003cstrong data-start=\"4102\" data-end=\"4124\"\u003eClass F insulation\u003c\/strong\u003e and \u003cstrong data-start=\"4129\" data-end=\"4154\"\u003eTP thermal protection\u003c\/strong\u003e. The original diagram identifies connections \u003cstrong data-start=\"4200\" data-end=\"4219\"\u003eL, Z, N, and PE\u003c\/strong\u003e. Its centrifugal configuration makes it suitable for industrial ventilation and cooling systems, including electrical panels, power electronics, inverters, and HVAC equipment, subject to verification of mechanical compatibility and operating point.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":54928482337101,"sku":null,"price":48.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7051.jpg?v=1790872021","url":"https:\/\/greenenergy-repair.com\/ru\/products\/fans-tech-230-vac-centrifugal-fan-109-w","provider":"Green Energy","version":"1.0","type":"link"}