{"product_id":"ebm-papst-vwcf119ajgms-4414-2h-24-v-dc-axial-fan-119-mm","title":"ebm-papst VWCF119AJGMS 4414\/2H | 24 V DC Axial Fan | 119 mm","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUsed product.\u003c\/strong\u003e Original \u003cstrong\u003eebm-papst\u003c\/strong\u003e axial fan, model \u003cstrong\u003e4414\/2 H\u003c\/strong\u003e, code \u003cstrong\u003e9293510514\u003c\/strong\u003e, designed for \u003cstrong\u003eforced cooling of electrical and electronic equipment\u003c\/strong\u003e, power systems, inverters, electrical panels, and industrial equipment.\u003cbr\u003eThe original \u003cstrong\u003eebm-papst\u003c\/strong\u003e label is clearly visible in the photographs, showing model \u003cstrong\u003eVWCF119AJGMS 4414\/2 H\u003c\/strong\u003e and code \u003cstrong\u003e9293510514\u003c\/strong\u003e. The fan is powered by \u003cstrong\u003e24 V DC\u003c\/strong\u003e, with a rated current of \u003cstrong\u003e0.36 A\u003c\/strong\u003e and power of \u003cstrong\u003e8.6 W\u003c\/strong\u003e. It is equipped with \u003cstrong\u003e3 wires\u003c\/strong\u003e, with power supply and tachometric signal.\u003cbr\u003eThe construction is that of a \u003cstrong\u003ecompact axial fan with a 119 mm square frame and 38 mm depth\u003c\/strong\u003e, with a \u003cstrong\u003ebrushless DC motor and ball bearings\u003c\/strong\u003e, suitable for continuous operation in industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cstrong\u003eebm-papst\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e4414\/2 H\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct code:\u003c\/strong\u003e \u003cstrong\u003e9293510514\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel code:\u003c\/strong\u003e \u003cstrong\u003eVWCF119AJGMS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e DC axial fan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e \u003cstrong\u003e24 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply range:\u003c\/strong\u003e \u003cstrong\u003e18–28 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e \u003cstrong\u003e0.36 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated power:\u003c\/strong\u003e \u003cstrong\u003e8.6 W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated speed:\u003c\/strong\u003e approx. \u003cstrong\u003e4300 rpm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cstrong\u003e119 × 119 × 38 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBearings:\u003c\/strong\u003e \u003cstrong\u003eball bearings\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow:\u003c\/strong\u003e approx. \u003cstrong\u003e4 m³\/min\u003c\/strong\u003e, equivalent to approx. \u003cstrong\u003e141 CFM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic pressure:\u003c\/strong\u003e approx. \u003cstrong\u003e160 Pa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e approx. \u003cstrong\u003e50 dB(A)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e \u003cstrong\u003e3 wires\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal:\u003c\/strong\u003e \u003cstrong\u003eTacho\u003c\/strong\u003e output for speed detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+UB:\u003c\/strong\u003e \u003cstrong\u003ered (RD)\u003c\/strong\u003e wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGND:\u003c\/strong\u003e \u003cstrong\u003eblue (BU)\u003c\/strong\u003e wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTacho:\u003c\/strong\u003e \u003cstrong\u003ewhite (WH)\u003c\/strong\u003e wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame material:\u003c\/strong\u003e technical plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor type:\u003c\/strong\u003e electronic\/brushless DC motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e approx. \u003cstrong\u003e0.27 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicated origin:\u003c\/strong\u003e \u003cstrong\u003eHungary\u003c\/strong\u003e\u003cbr\u003eCatalog data confirm for code \u003cstrong\u003e9293510514 \/ 4414\/2H\u003c\/strong\u003e a 24 V DC supply, 4300 rpm, 8.6 W, 4 m³\/min, 160 Pa, 50 dB(A), ball bearings, and a \u003cstrong\u003e3-wire connection with tachometer\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong\u003eElectrical Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe label clearly shows the three-conductor configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRD \/ Red = +UB\u003c\/strong\u003e, positive power supply;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBU \/ Blue = GND\u003c\/strong\u003e, negative\/power supply;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWH \/ White = Tacho\u003c\/strong\u003e, tachometric signal.\u003cbr\u003eThe third wire therefore allows the fan to be used in systems equipped with \u003cstrong\u003espeed control or rotation detection\u003c\/strong\u003e, a particularly useful function in inverters and industrial equipment where correct ventilation operation must be monitored. Commercial documentation identifies the model as a \u003cstrong\u003e3-wire version with tachometer\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong\u003eFunction in the Electrical System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe main function of the \u003cstrong\u003e4414\/2H\u003c\/strong\u003e is to provide \u003cstrong\u003eforced cooling\u003c\/strong\u003e for electronic and power components.\u003cbr\u003eThe airflow of approximately \u003cstrong\u003e4 m³\/min\u003c\/strong\u003e allows heat generated during operation to be removed from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ephotovoltaic inverters;\u003c\/li\u003e\n\u003cli\u003eDC\/DC and AC\/DC converters;\u003c\/li\u003e\n\u003cli\u003eindustrial power supplies;\u003c\/li\u003e\n\u003cli\u003eelectrical panels;\u003c\/li\u003e\n\u003cli\u003epower electronic systems;\u003c\/li\u003e\n\u003cli\u003eindustrial automation equipment;\u003c\/li\u003e\n\u003cli\u003eelectrical cabinets and electronic cooling systems.\u003cbr\u003eThe \u003cstrong\u003eTacho\u003c\/strong\u003e signal can be used by the control electronics to verify that the fan is actually rotating. Failure to detect the speed can therefore be used as an alarm or equipment protection condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong\u003eFaults, Errors and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eFan wear or malfunction may cause:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eincreased internal equipment temperature\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003etemperature alarms;\u003c\/li\u003e\n\u003cli\u003ereduced inverter or electronics performance;\u003c\/li\u003e\n\u003cli\u003eshutdowns due to \u003cstrong\u003eovertemperature\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003efan failure to start;\u003c\/li\u003e\n\u003cli\u003eirregular rotation;\u003c\/li\u003e\n\u003cli\u003eabnormal bearing noise;\u003c\/li\u003e\n\u003cli\u003evibrations;\u003c\/li\u003e\n\u003cli\u003ereduced airflow;\u003c\/li\u003e\n\u003cli\u003eloss or abnormality of the \u003cstrong\u003etachometric signal\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eintermittent shutdown during operation.\u003cbr\u003eThe presence of a stopped fan does not necessarily mean that the motor is faulty: \u003cstrong\u003e24 V DC power supply, wiring, connector, control circuit, and Tacho signal\u003c\/strong\u003e must also be checked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🏭 \u003cstrong\u003eConstruction and Product Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe photographed fan is \u003cstrong\u003eused\u003c\/strong\u003e and shows normal signs of previous use and handling.\u003cbr\u003eThe frame and blades appear \u003cstrong\u003eintact\u003c\/strong\u003e, with no evident structural breaks in the photographs. The \u003cstrong\u003ethree original conductors\u003c\/strong\u003e with free ends are present, as visible in the images.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🌐 \u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eebm-papst 4414\/2H\u003c\/strong\u003e is particularly suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ephotovoltaic inverters\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eindustrial inverters;\u003c\/li\u003e\n\u003cli\u003epower converters;\u003c\/li\u003e\n\u003cli\u003epower supplies;\u003c\/li\u003e\n\u003cli\u003eelectrical panels;\u003c\/li\u003e\n\u003cli\u003eelectronic equipment;\u003c\/li\u003e\n\u003cli\u003eautomation systems;\u003c\/li\u003e\n\u003cli\u003eelectrical cabinets with forced cooling;\u003c\/li\u003e\n\u003cli\u003eindustrial systems requiring continuous ventilation.\u003cbr\u003eThe compact dimensions \u003cstrong\u003e119 × 119 × 38 mm\u003c\/strong\u003e and \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply make it suitable for replacing equivalent industrial fans, always checking \u003cstrong\u003edimensions, voltage, current, airflow, pressure, and Tacho signal configuration\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong\u003eSafety and Installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eInstallation must be carried out with the equipment \u003cstrong\u003edisconnected from the power supply\u003c\/strong\u003e.\u003cbr\u003eThe polarity indicated on the label must be respected:\u003cbr\u003e\u003cstrong\u003ered = +24 V DC, blue = GND, white = Tacho\u003c\/strong\u003e.\u003cbr\u003eThe fan must be installed with adequate fastening and sufficient space to allow proper airflow. No foreign objects should be present that could enter the blades during operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1 × ebm-papst 4414\/2H axial fan\u003c\/strong\u003e, code \u003cstrong\u003e9293510514\u003c\/strong\u003e, \u003cstrong\u003e24 V DC – 0.36 A – 8.6 W\u003c\/strong\u003e, complete with the \u003cstrong\u003e3 connection wires\u003c\/strong\u003e, as shown in the photographs.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🚀 \u003cstrong\u003eFinal Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eebm-papst 4414\/2H 9293510514\u003c\/strong\u003e is a \u003cstrong\u003e119 × 119 × 38 mm industrial axial fan\u003c\/strong\u003e, powered by \u003cstrong\u003e24 V DC\u003c\/strong\u003e, with a power rating of \u003cstrong\u003e8.6 W\u003c\/strong\u003e, current of \u003cstrong\u003e0.36 A\u003c\/strong\u003e, speed of approximately \u003cstrong\u003e4300 rpm\u003c\/strong\u003e, airflow up to approximately \u003cstrong\u003e4 m³\/min\u003c\/strong\u003e, and static pressure of approximately \u003cstrong\u003e160 Pa\u003c\/strong\u003e.\u003cbr\u003eThe presence of the \u003cstrong\u003ethird tachometric wire\u003c\/strong\u003e allows the equipment to monitor rotation, making it particularly suitable for industrial and electronic systems where correct ventilation operation must also be monitored. The data for the exact code \u003cstrong\u003e9293510514 \/ 4414\/2H\u003c\/strong\u003e are confirmed by technical catalogs and distributors.\u003c\/p\u003e","brand":"ebm-papst Axial Fan","offers":[{"title":"Default Title","offer_id":54711276765517,"sku":null,"price":45.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6786.jpg?v=1789134544","url":"https:\/\/greenenergy-repair.com\/ru\/products\/ebm-papst-vwcf119ajgms-4414-2h-24-v-dc-axial-fan-119-mm","provider":"Green Energy","version":"1.0","type":"link"}