{"product_id":"abb-uno-dm-6-0-tl-plus-b-g-single-phase-photovoltaic-inverter-6-kw-lcd-display-dual-mppt-ip65-protection","title":"ABB UNO-DM-6.0-TL-PLUS-B-G Single-Phase Photovoltaic Inverter 6 kW – LCD Display, Dual MPPT \u0026 IP65 Protection","description":"\u003cp data-end=\"530\" data-start=\"217\"\u003eThe \u003cstrong data-end=\"251\" data-start=\"221\"\u003eABB UNO-DM-6.0-TL-PLUS-B-G\u003c\/strong\u003e photovoltaic inverter is a high-efficiency professional solution designed for residential and commercial solar power systems. Engineered and manufactured in Italy by ABB (now FIMER), this inverter combines reliability, easy installation, and advanced energy management features.\u003c\/p\u003e\n\u003cp data-end=\"742\" data-start=\"532\"\u003eThe unit is equipped with an integrated front-mounted \u003cstrong data-end=\"623\" data-start=\"586\"\u003eLCD display and navigation keypad\u003c\/strong\u003e, allowing immediate access to energy production data, inverter operating status, alarms, and configuration parameters.\u003c\/p\u003e\n\u003cp data-end=\"995\" data-start=\"744\"\u003eThanks to its \u003cstrong data-end=\"791\" data-start=\"758\"\u003etwo independent MPPT trackers\u003c\/strong\u003e, the inverter can manage two separate photovoltaic strings, maximizing energy production even when solar modules are installed on different roof orientations or are subject to partial shading conditions.\u003c\/p\u003e\n\u003cp data-end=\"1347\" data-start=\"997\"\u003eThe robust \u003cstrong data-end=\"1032\" data-start=\"1008\"\u003eIP65-rated enclosure\u003c\/strong\u003e provides excellent protection against dust and water, making the inverter suitable for both indoor and outdoor installations. Its \u003cstrong data-end=\"1197\" data-start=\"1163\"\u003efanless passive cooling system\u003c\/strong\u003e, based on a high-efficiency aluminum heatsink, ensures silent operation and increased long-term reliability by eliminating moving cooling components.\u003c\/p\u003e\n\u003cp data-end=\"1502\" data-start=\"1349\"\u003eThe ABB UNO-DM series is highly regarded for its build quality, operational stability, and seamless integration into grid-connected photovoltaic systems.\u003c\/p\u003e\n\u003chr data-end=\"1507\" data-start=\"1504\"\u003e\n\u003ch2 data-end=\"1539\" data-start=\"1509\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-end=\"1564\" data-start=\"1541\"\u003eGeneral Information\u003c\/h3\u003e\n\u003cul data-end=\"1728\" data-start=\"1566\"\u003e\n\u003cli data-end=\"1585\" data-start=\"1566\"\u003eManufacturer: ABB\u003c\/li\u003e\n\u003cli data-end=\"1602\" data-start=\"1586\"\u003eSeries: UNO-DM\u003c\/li\u003e\n\u003cli data-end=\"1634\" data-start=\"1603\"\u003eModel: UNO-DM-6.0-TL-PLUS-B-G\u003c\/li\u003e\n\u003cli data-end=\"1696\" data-start=\"1635\"\u003eInverter Type: Single-Phase Grid-Tied Photovoltaic Inverter\u003c\/li\u003e\n\u003cli data-end=\"1728\" data-start=\"1697\"\u003eCountry of Manufacture: Italy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1762\" data-start=\"1730\"\u003eDC Input (Photovoltaic Side)\u003c\/h3\u003e\n\u003cul data-end=\"2032\" data-start=\"1764\"\u003e\n\u003cli data-end=\"1794\" data-start=\"1764\"\u003eRated Inverter Power: 6000 W\u003c\/li\u003e\n\u003cli data-end=\"1830\" data-start=\"1795\"\u003eMaximum DC Input Voltage: 600 VDC\u003c\/li\u003e\n\u003cli data-end=\"1873\" data-start=\"1831\"\u003eDC Operating Voltage Range: 90 – 580 VDC\u003c\/li\u003e\n\u003cli data-end=\"1909\" data-start=\"1874\"\u003eMPPT Voltage Range: 160 – 480 VDC\u003c\/li\u003e\n\u003cli data-end=\"1956\" data-start=\"1910\"\u003eNumber of MPPT Trackers: 2 Independent MPPTs\u003c\/li\u003e\n\u003cli data-end=\"1990\" data-start=\"1957\"\u003eMaximum Input Current: 2 × 20 A\u003c\/li\u003e\n\u003cli data-end=\"2032\" data-start=\"1991\"\u003eMaximum Short-Circuit Current: 2 × 24 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2059\" data-start=\"2034\"\u003eAC Output (Grid Side)\u003c\/h3\u003e\n\u003cul data-end=\"2258\" data-start=\"2061\"\u003e\n\u003cli data-end=\"2089\" data-start=\"2061\"\u003eRated Active Power: 6000 W\u003c\/li\u003e\n\u003cli data-end=\"2123\" data-start=\"2090\"\u003eMaximum Apparent Power: 6650 VA\u003c\/li\u003e\n\u003cli data-end=\"2168\" data-start=\"2124\"\u003eNominal Grid Voltage: 230 VAC Single-Phase\u003c\/li\u003e\n\u003cli data-end=\"2192\" data-start=\"2169\"\u003eGrid Frequency: 50 Hz\u003c\/li\u003e\n\u003cli data-end=\"2223\" data-start=\"2193\"\u003eMaximum Output Current: 30 A\u003c\/li\u003e\n\u003cli data-end=\"2258\" data-start=\"2224\"\u003eAdjustable Power Factor: 0.1 – 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2305\" data-start=\"2260\"\u003eMechanical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul data-end=\"2554\" data-start=\"2307\"\u003e\n\u003cli data-end=\"2331\" data-start=\"2307\"\u003eIntegrated LCD Display\u003c\/li\u003e\n\u003cli data-end=\"2357\" data-start=\"2332\"\u003eFront Navigation Keypad\u003c\/li\u003e\n\u003cli data-end=\"2390\" data-start=\"2358\"\u003ePassive Fanless Cooling System\u003c\/li\u003e\n\u003cli data-end=\"2426\" data-start=\"2391\"\u003eHigh-Efficiency Aluminum Heatsink\u003c\/li\u003e\n\u003cli data-end=\"2460\" data-start=\"2427\"\u003eIndoor and Outdoor Installation\u003c\/li\u003e\n\u003cli data-end=\"2486\" data-start=\"2461\"\u003eProtection Rating: IP65\u003c\/li\u003e\n\u003cli data-end=\"2514\" data-start=\"2487\"\u003eProtection Class: Class I\u003c\/li\u003e\n\u003cli data-end=\"2554\" data-start=\"2515\"\u003eOperating Temperature: -25°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2571\" data-start=\"2556\"\u003eConnections\u003c\/h3\u003e\n\u003cul data-end=\"2705\" data-start=\"2573\"\u003e\n\u003cli data-end=\"2619\" data-start=\"2573\"\u003e2 Independent PV String Inputs (IN1 and IN2)\u003c\/li\u003e\n\u003cli data-end=\"2640\" data-start=\"2620\"\u003eAC Grid Connection\u003c\/li\u003e\n\u003cli data-end=\"2705\" data-start=\"2641\"\u003eIntegrated Communication Port for Monitoring and Configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2710\" data-start=\"2707\"\u003e\n\u003ch2 data-end=\"2731\" data-start=\"2712\"\u003e🔧 Main Features\u003c\/h2\u003e\n\u003cp data-end=\"2758\" data-start=\"2733\"\u003e✔ 6 kW rated output power\u003c\/p\u003e\n\u003cp data-end=\"2792\" data-start=\"2760\"\u003e✔ Dual independent MPPT trackers\u003c\/p\u003e\n\u003cp data-end=\"2837\" data-start=\"2794\"\u003e✔ Integrated LCD display and user interface\u003c\/p\u003e\n\u003cp data-end=\"2871\" data-start=\"2839\"\u003e✔ Fanless passive cooling design\u003c\/p\u003e\n\u003cp data-end=\"2891\" data-start=\"2873\"\u003e✔ Silent operation\u003c\/p\u003e\n\u003cp data-end=\"2935\" data-start=\"2893\"\u003e✔ IP65 protection for outdoor installation\u003c\/p\u003e\n\u003cp data-end=\"2980\" data-start=\"2937\"\u003e✔ Supports independent photovoltaic strings\u003c\/p\u003e\n\u003cp data-end=\"3010\" data-start=\"2982\"\u003e✔ High conversion efficiency\u003c\/p\u003e\n\u003cp data-end=\"3043\" data-start=\"3012\"\u003e✔ Reliable ABB\/FIMER technology\u003c\/p\u003e\n\u003cp data-end=\"3100\" data-start=\"3045\"\u003e✔ Suitable for residential and commercial solar systems\u003c\/p\u003e\n\u003chr data-end=\"3710\" data-start=\"3707\"\u003e\n\u003ch2 data-end=\"3742\" data-start=\"3712\"\u003e🏠 Recommended Applications\u003c\/h2\u003e\n\u003cp data-end=\"3756\" data-start=\"3744\"\u003ePerfect for:\u003c\/p\u003e\n\u003cul data-end=\"4011\" data-start=\"3758\"\u003e\n\u003cli data-end=\"3808\" data-start=\"3758\"\u003eResidential photovoltaic systems from 5 to 8 kWp\u003c\/li\u003e\n\u003cli data-end=\"3835\" data-start=\"3809\"\u003ePrivate homes and villas\u003c\/li\u003e\n\u003cli data-end=\"3861\" data-start=\"3836\"\u003eAgricultural facilities\u003c\/li\u003e\n\u003cli data-end=\"3899\" data-start=\"3862\"\u003eWarehouses and industrial buildings\u003c\/li\u003e\n\u003cli data-end=\"3929\" data-start=\"3900\"\u003eSmall commercial businesses\u003c\/li\u003e\n\u003cli data-end=\"3966\" data-start=\"3930\"\u003eGrid-connected solar installations\u003c\/li\u003e\n\u003cli data-end=\"4011\" data-start=\"3967\"\u003eRetrofit and inverter replacement projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4016\" data-start=\"4013\"\u003e\n\u003ch2 data-end=\"4050\" data-start=\"4018\"\u003e⚠️ Common Faults and Symptoms\u003c\/h2\u003e\n\u003ch3 data-end=\"4078\" data-start=\"4052\"\u003eGrid Connection Issues\u003c\/h3\u003e\n\u003cp data-end=\"4089\" data-start=\"4080\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"4116\" data-start=\"4091\"\u003e❗ Grid connection failure\u003c\/p\u003e\n\u003cp data-end=\"4142\" data-start=\"4118\"\u003e❗ Utility voltage alarms\u003c\/p\u003e\n\u003cp data-end=\"4189\" data-start=\"4144\"\u003e❗ Inverter remains disconnected from the grid\u003c\/p\u003e\n\u003cp data-end=\"4207\" data-start=\"4191\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-end=\"4297\" data-start=\"4209\"\u003e\n\u003cli data-end=\"4248\" data-start=\"4209\"\u003eGrid voltage outside permitted limits\u003c\/li\u003e\n\u003cli data-end=\"4267\" data-start=\"4249\"\u003eAC wiring faults\u003c\/li\u003e\n\u003cli data-end=\"4297\" data-start=\"4268\"\u003eUtility network instability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4318\" data-start=\"4299\"\u003ePV Input Issues\u003c\/h3\u003e\n\u003cp data-end=\"4329\" data-start=\"4320\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"4357\" data-start=\"4331\"\u003e❗ Reduced power production\u003c\/p\u003e\n\u003cp data-end=\"4378\" data-start=\"4359\"\u003e❗ DC voltage alarms\u003c\/p\u003e\n\u003cp data-end=\"4397\" data-start=\"4380\"\u003e❗ Startup failure\u003c\/p\u003e\n\u003cp data-end=\"4415\" data-start=\"4399\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-end=\"4512\" data-start=\"4417\"\u003e\n\u003cli data-end=\"4449\" data-start=\"4417\"\u003eIncorrect string configuration\u003c\/li\u003e\n\u003cli data-end=\"4473\" data-start=\"4450\"\u003eDamaged PV connectors\u003c\/li\u003e\n\u003cli data-end=\"4496\" data-start=\"4474\"\u003eExcessive DC voltage\u003c\/li\u003e\n\u003cli data-end=\"4512\" data-start=\"4497\"\u003eWiring faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4547\" data-start=\"4514\"\u003eDisplay or Interface Problems\u003c\/h3\u003e\n\u003cp data-end=\"4558\" data-start=\"4549\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"4589\" data-start=\"4560\"\u003e❗ LCD display not functioning\u003c\/p\u003e\n\u003cp data-end=\"4622\" data-start=\"4591\"\u003e❗ Missing operating information\u003c\/p\u003e\n\u003cp data-end=\"4645\" data-start=\"4624\"\u003e❗ Keypad unresponsive\u003c\/p\u003e\n\u003cp data-end=\"4663\" data-start=\"4647\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-end=\"4749\" data-start=\"4665\"\u003e\n\u003cli data-end=\"4695\" data-start=\"4665\"\u003eInternal power supply faults\u003c\/li\u003e\n\u003cli data-end=\"4720\" data-start=\"4696\"\u003eDisplay module failure\u003c\/li\u003e\n\u003cli data-end=\"4749\" data-start=\"4721\"\u003eCommunication board issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4769\" data-start=\"4751\"\u003eThermal Alarms\u003c\/h3\u003e\n\u003cp data-end=\"4780\" data-start=\"4771\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"4798\" data-start=\"4782\"\u003e❗ Power derating\u003c\/p\u003e\n\u003cp data-end=\"4822\" data-start=\"4800\"\u003e❗ Temperature warnings\u003c\/p\u003e\n\u003cp data-end=\"4844\" data-start=\"4824\"\u003e❗ Automatic shutdown\u003c\/p\u003e\n\u003cp data-end=\"4862\" data-start=\"4846\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-end=\"4939\" data-start=\"4864\"\u003e\n\u003cli data-end=\"4884\" data-start=\"4864\"\u003eRestricted airflow\u003c\/li\u003e\n\u003cli data-end=\"4912\" data-start=\"4885\"\u003eHigh ambient temperatures\u003c\/li\u003e\n\u003cli data-end=\"4939\" data-start=\"4913\"\u003eInternal component aging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4971\" data-start=\"4941\"\u003eInternal Hardware Failures\u003c\/h3\u003e\n\u003cp data-end=\"4982\" data-start=\"4973\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"5001\" data-start=\"4984\"\u003e❗ Random restarts\u003c\/p\u003e\n\u003cp data-end=\"5019\" data-start=\"5003\"\u003e❗ Fault messages\u003c\/p\u003e\n\u003cp data-end=\"5040\" data-start=\"5021\"\u003e❗ Inverter shutdown\u003c\/p\u003e\n\u003cp data-end=\"5058\" data-start=\"5042\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-end=\"5153\" data-start=\"5060\"\u003e\n\u003cli data-end=\"5078\" data-start=\"5060\"\u003eAging capacitors\u003c\/li\u003e\n\u003cli data-end=\"5102\" data-start=\"5079\"\u003ePower supply failures\u003c\/li\u003e\n\u003cli data-end=\"5125\" data-start=\"5103\"\u003eControl board faults\u003c\/li\u003e\n\u003cli data-end=\"5153\" data-start=\"5126\"\u003eSurge or lightning damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"5158\" data-start=\"5155\"\u003e\n\u003ch2 data-end=\"5192\" data-start=\"5160\"\u003e🚨 Possible Associated Errors\u003c\/h2\u003e\n\u003cp data-end=\"5248\" data-start=\"5194\"\u003eA malfunctioning inverter may generate alarms such as:\u003c\/p\u003e\n\u003cul data-end=\"5493\" data-start=\"5250\"\u003e\n\u003cli data-end=\"5262\" data-start=\"5250\"\u003eGrid Fault\u003c\/li\u003e\n\u003cli data-end=\"5272\" data-start=\"5263\"\u003eNo Grid\u003c\/li\u003e\n\u003cli data-end=\"5292\" data-start=\"5273\"\u003eGrid Voltage High\u003c\/li\u003e\n\u003cli data-end=\"5311\" data-start=\"5293\"\u003eGrid Voltage Low\u003c\/li\u003e\n\u003cli data-end=\"5334\" data-start=\"5312\"\u003eGrid Frequency Error\u003c\/li\u003e\n\u003cli data-end=\"5352\" data-start=\"5335\"\u003eIsolation Fault\u003c\/li\u003e\n\u003cli data-end=\"5367\" data-start=\"5353\"\u003eGround Fault\u003c\/li\u003e\n\u003cli data-end=\"5384\" data-start=\"5368\"\u003eDC Input Error\u003c\/li\u003e\n\u003cli data-end=\"5402\" data-start=\"5385\"\u003eOvertemperature\u003c\/li\u003e\n\u003cli data-end=\"5419\" data-start=\"5403\"\u003eInternal Error\u003c\/li\u003e\n\u003cli data-end=\"5441\" data-start=\"5420\"\u003eCommunication Error\u003c\/li\u003e\n\u003cli data-end=\"5461\" data-start=\"5442\"\u003ePower Stage Fault\u003c\/li\u003e\n\u003cli data-end=\"5480\" data-start=\"5462\"\u003eHardware Failure\u003c\/li\u003e\n\u003cli data-end=\"5493\" data-start=\"5481\"\u003eMPPT Fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"5584\" data-start=\"5495\"\u003eActual fault messages may vary according to firmware version and local grid requirements.\u003c\/p\u003e\n\u003chr data-end=\"5589\" data-start=\"5586\"\u003e\n\u003ch2 data-end=\"5614\" data-start=\"5591\"\u003e📦 Product Condition\u003c\/h2\u003e\n\u003cul data-end=\"5889\" data-start=\"5616\"\u003e\n\u003cli data-end=\"5631\" data-start=\"5616\"\u003eUsed inverter\u003c\/li\u003e\n\u003cli data-end=\"5692\" data-start=\"5632\"\u003eComplete with original LCD display and front control panel\u003c\/li\u003e\n\u003cli data-end=\"5732\" data-start=\"5693\"\u003eNormal cosmetic signs of previous use\u003c\/li\u003e\n\u003cli data-end=\"5798\" data-start=\"5733\"\u003eHeatsink, enclosure, and connectors as shown in the photographs\u003c\/li\u003e\n\u003cli data-end=\"5889\" data-start=\"5799\"\u003eSuitable as a replacement unit, spare part, or for compatible photovoltaic installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"5894\" data-start=\"5891\"\u003e\n\u003ch2 data-end=\"5911\" data-start=\"5896\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cp data-end=\"5944\" data-start=\"5913\"\u003e✔ Original ABB \/ FIMER inverter\u003c\/p\u003e\n\u003cp data-end=\"6000\" data-start=\"5946\"\u003e✔ Dual MPPT technology for optimized energy production\u003c\/p\u003e\n\u003cp data-end=\"6045\" data-start=\"6002\"\u003e✔ Integrated LCD monitoring and diagnostics\u003c\/p\u003e\n\u003cp data-end=\"6085\" data-start=\"6047\"\u003e✔ Fanless cooling for silent operation\u003c\/p\u003e\n\u003cp data-end=\"6140\" data-start=\"6087\"\u003e✔ IP65 protection for indoor and outdoor installation\u003c\/p\u003e\n\u003cp data-end=\"6174\" data-start=\"6142\"\u003e✔ Reliable long-term performance\u003c\/p\u003e\n\u003cp data-end=\"6212\" data-start=\"6176\"\u003e✔ Easy maintenance and configuration\u003c\/p\u003e\n\u003cp data-end=\"6265\" data-start=\"6214\"\u003e✔ Ideal for residential and commercial applications\u003c\/p\u003e\n\u003cp data-end=\"6306\" data-start=\"6267\"\u003e✔ Made in Italy quality and engineering\u003c\/p\u003e\n\u003chr data-end=\"6311\" data-start=\"6308\"\u003e\n\u003ch2 data-end=\"6326\" data-start=\"6313\"\u003e🟢 Summary\u003c\/h2\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"6725\" data-start=\"6328\"\u003eThe \u003cstrong data-end=\"6362\" data-start=\"6332\"\u003eABB UNO-DM-6.0-TL-PLUS-B-G\u003c\/strong\u003e is a \u003cstrong data-end=\"6411\" data-start=\"6368\"\u003e6 kW single-phase photovoltaic inverter\u003c\/strong\u003e featuring \u003cstrong data-end=\"6529\" data-start=\"6422\"\u003edual independent MPPT trackers, an integrated LCD display, fanless passive cooling, and IP65 protection\u003c\/strong\u003e. Designed and manufactured in Italy by ABB, it delivers reliable energy conversion, advanced monitoring capabilities, and optimized performance for residential and commercial solar installations.\u003c\/p\u003e","brand":"ABB Aurora used","offers":[{"title":"Default Title","offer_id":54114897297741,"sku":null,"price":550.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/7977675e-da94-47b6-80fe-c9fe18a58614.png?v=1781534380","url":"https:\/\/greenenergy-repair.com\/ru\/products\/abb-uno-dm-6-0-tl-plus-b-g-single-phase-photovoltaic-inverter-6-kw-lcd-display-dual-mppt-ip65-protection","provider":"Green Energy","version":"1.0","type":"link"}