{"product_id":"schneider-electric-sw60-dc-63a-4-pole-dc-switch-disconnector-63a-1000v-dc-dc-21a-iec-en-60947-3-multi-9","title":"Schneider Electric SW60-DC 63A – 4-Pole DC Switch Disconnector 63A | 1000V DC | DC-21A | IEC\/EN 60947-3 | Multi 9","description":"\u003cp data-start=\"207\" data-end=\"527\"\u003eThe \u003cstrong data-start=\"211\" data-end=\"245\"\u003eSchneider Electric SW60-DC 63A\u003c\/strong\u003e is a \u003cstrong data-start=\"251\" data-end=\"284\"\u003e4-pole DC switch disconnector\u003c\/strong\u003e designed for applications up to \u003cstrong data-start=\"317\" data-end=\"330\"\u003e1000 V DC\u003c\/strong\u003e. Part of the professional \u003cstrong data-start=\"357\" data-end=\"398\"\u003eMulti 9 range (formerly Merlin Gerin)\u003c\/strong\u003e, it is specifically engineered for photovoltaic systems and high-voltage DC installations requiring safe and reliable isolation.\u003c\/p\u003e\n\u003cp data-start=\"529\" data-end=\"787\"\u003eThe device allows \u003cstrong data-start=\"547\" data-end=\"596\"\u003eload switching in DC-21A utilization category\u003c\/strong\u003e, ensuring high operational safety and robust mechanical performance. The \u003cstrong data-start=\"670\" data-end=\"694\"\u003e4-pole configuration\u003c\/strong\u003e enables simultaneous isolation of multiple strings or conductors in high-voltage DC systems.\u003c\/p\u003e\n\u003cp data-start=\"789\" data-end=\"900\"\u003e⚠ This device is a \u003cstrong data-start=\"808\" data-end=\"836\"\u003eswitch disconnector only\u003c\/strong\u003e – it does \u003cstrong data-start=\"847\" data-end=\"854\"\u003enot\u003c\/strong\u003e provide overload or short-circuit protection.\u003c\/p\u003e\n\u003chr data-start=\"902\" data-end=\"905\"\u003e\n\u003ch2 data-start=\"907\" data-end=\"939\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"941\" data-end=\"1402\"\u003e\u003cstrong data-start=\"941\" data-end=\"951\"\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003cbr data-start=\"970\" data-end=\"973\"\u003e\u003cstrong data-start=\"973\" data-end=\"984\"\u003eSeries:\u003c\/strong\u003e SW60-DC (Multi 9 \/ Merlin Gerin)\u003cbr data-start=\"1017\" data-end=\"1020\"\u003e\u003cstrong data-start=\"1020\" data-end=\"1036\"\u003eDevice Type:\u003c\/strong\u003e DC switch disconnector\u003cbr data-start=\"1059\" data-end=\"1062\"\u003e\u003cstrong data-start=\"1062\" data-end=\"1082\"\u003eNumber of poles:\u003c\/strong\u003e 4P\u003cbr data-start=\"1085\" data-end=\"1088\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1111\"\u003eRated current (In):\u003c\/strong\u003e 63 A\u003cbr data-start=\"1116\" data-end=\"1119\"\u003e\u003cstrong data-start=\"1119\" data-end=\"1154\"\u003eRated operational voltage (Ui):\u003c\/strong\u003e 1000 V DC\u003cbr data-start=\"1164\" data-end=\"1167\"\u003e\u003cstrong data-start=\"1167\" data-end=\"1192\"\u003eUtilization category:\u003c\/strong\u003e DC-21A\u003cbr data-start=\"1199\" data-end=\"1202\"\u003e\u003cstrong data-start=\"1202\" data-end=\"1239\"\u003eImpulse withstand voltage (Uimp):\u003c\/strong\u003e 6 kV\u003cbr data-start=\"1244\" data-end=\"1247\"\u003e\u003cstrong data-start=\"1247\" data-end=\"1260\"\u003eStandard:\u003c\/strong\u003e IEC \/ EN 60947-3\u003cbr data-start=\"1277\" data-end=\"1280\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1308\"\u003eConductor cross-section:\u003c\/strong\u003e 1 – 35 mm²\u003cbr data-start=\"1319\" data-end=\"1322\"\u003e\u003cstrong data-start=\"1322\" data-end=\"1344\"\u003eTightening torque:\u003c\/strong\u003e 3.5 Nm\u003cbr data-start=\"1351\" data-end=\"1354\"\u003e\u003cstrong data-start=\"1354\" data-end=\"1367\"\u003eMounting:\u003c\/strong\u003e DIN rail 35 mm\u003cbr data-start=\"1382\" data-end=\"1385\"\u003e\u003cstrong data-start=\"1385\" data-end=\"1397\"\u003eMarking:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003cp data-start=\"1404\" data-end=\"1472\"\u003e⚠ Clear polarity indication \u003cstrong data-start=\"1432\" data-end=\"1443\"\u003eL+ \/ L-\u003c\/strong\u003e for correct DC installation.\u003c\/p\u003e\n\u003chr data-start=\"1474\" data-end=\"1477\"\u003e\n\u003ch2 data-start=\"1479\" data-end=\"1495\"\u003e🔒 Function\u003c\/h2\u003e\n\u003cp data-start=\"1497\" data-end=\"1510\"\u003eDesigned for:\u003c\/p\u003e\n\u003cp data-start=\"1512\" data-end=\"1658\"\u003e✔ DC line isolation\u003cbr data-start=\"1531\" data-end=\"1534\"\u003e✔ Photovoltaic string disconnection\u003cbr data-start=\"1569\" data-end=\"1572\"\u003e✔ Load switching in DC-21A category\u003cbr data-start=\"1607\" data-end=\"1610\"\u003e✔ Safe interruption in systems up to 1000 V DC\u003c\/p\u003e\n\u003cp data-start=\"1660\" data-end=\"1754\"\u003eThis unit ensures secure manual disconnection of DC circuits in compliance with IEC standards.\u003c\/p\u003e\n\u003chr data-start=\"1756\" data-end=\"1759\"\u003e\n\u003ch2 data-start=\"1761\" data-end=\"1781\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1783\" data-end=\"1941\"\u003e✔ Photovoltaic installations (string isolation)\u003cbr data-start=\"1830\" data-end=\"1833\"\u003e✔ DC combiner boxes\u003cbr data-start=\"1852\" data-end=\"1855\"\u003e✔ Energy storage systems\u003cbr data-start=\"1879\" data-end=\"1882\"\u003e✔ Industrial DC systems\u003cbr data-start=\"1905\" data-end=\"1908\"\u003e✔ Inverter DC-side applications\u003c\/p\u003e\n\u003chr data-start=\"1943\" data-end=\"1946\"\u003e\n\u003ch2 data-start=\"1948\" data-end=\"1968\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1970\" data-end=\"2176\"\u003e\n\u003cli data-start=\"1970\" data-end=\"2009\"\u003e\n\u003cp data-start=\"1972\" data-end=\"2009\"\u003eMounting on standard 35 mm DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2010\" data-end=\"2054\"\u003e\n\u003cp data-start=\"2012\" data-end=\"2054\"\u003eConnection respecting indicated polarity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2055\" data-end=\"2115\"\u003e\n\u003cp data-start=\"2057\" data-end=\"2115\"\u003eInstallation inside suitably rated electrical enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2116\" data-end=\"2176\"\u003e\n\u003cp data-start=\"2118\" data-end=\"2176\"\u003eCompliant with IEC standards for DC switch disconnectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2178\" data-end=\"2181\"\u003e\n\u003ch2 data-start=\"2183\" data-end=\"2200\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2202\" data-end=\"2284\"\u003eUsed product in good cosmetic condition.\u003cbr data-start=\"2242\" data-end=\"2245\"\u003eSupplied as shown in the photographs.\u003c\/p\u003e\n\u003chr data-start=\"2286\" data-end=\"2289\"\u003e\n\u003ch2 data-start=\"2291\" data-end=\"2314\"\u003e📦 Scope of Supply\u003c\/h2\u003e\n\u003cul data-start=\"2316\" data-end=\"2376\"\u003e\n\u003cli data-start=\"2316\" data-end=\"2376\"\u003e\n\u003cp data-start=\"2318\" data-end=\"2376\"\u003e1x Schneider Electric SW60-DC 63A 4P switch disconnector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2378\" data-end=\"2381\"\u003e\n\u003ch2 data-start=\"2383\" data-end=\"2409\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2411\" data-end=\"2689\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eA professional 63A DC switch disconnector rated up to 1000V DC, featuring 4-pole isolation and DC-21A load switching capability. The Schneider Electric SW60-DC offers a reliable and standards-compliant solution for safe disconnection in photovoltaic and high-voltage DC systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53459592446285,"sku":null,"price":80.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5069.jpg?v=1772529684","url":"https:\/\/greenenergy-repair.com\/ro\/products\/schneider-electric-sw60-dc-63a-4-pole-dc-switch-disconnector-63a-1000v-dc-dc-21a-iec-en-60947-3-multi-9","provider":"Green Energy","version":"1.0","type":"link"}