{"product_id":"kostal-piko-10-1-ac-power-board-3-phase","title":"KOSTAL PIKO 10.1 | AC Power Board | 3-Phase","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-6\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-6\" data-turn-id-container=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-6\" data-testid=\"conversation-turn-12\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" data-dil-talvt-response-state=\"complete\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 [\u0026amp;\u0026gt;div:has([data-free-thinking-preview-answer=true])+:is(.text-message,.relative:has(\u0026gt;.text-message))]:-mt-2 grow\"\u003e\n\u003cdiv class=\"TzNmiG_container gap-4 [\u0026amp;\u0026gt;div:has([data-free-thinking-preview-answer=true])+:is(.text-message,.relative:has(\u0026gt;.text-message))]:-mt-2\" data-streaming-response-group=\"\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"3b551fae-4046-4499-a895-b48bf078cb77\" data-markdown-talvt-message-id=\"3b551fae-4046-4499-a895-b48bf078cb77\" dir=\"auto\" data-message-model-slug=\"gpt-5-6\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"fbskMG_root LR5Y_W_content markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch3 dir=\"auto\" data-start=\"50\" data-end=\"72\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"57\" data-end=\"72\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"73\" data-end=\"650\"\u003e\u003cstrong data-start=\"73\" data-end=\"89\"\u003eUsed product\u003c\/strong\u003e – Original \u003cstrong data-start=\"101\" data-end=\"111\"\u003eKOSTAL\u003c\/strong\u003e board for \u003cstrong data-start=\"122\" data-end=\"169\"\u003ePIKO 10.1 three-phase photovoltaic inverter\u003c\/strong\u003e, identified on the PCB by the marking \u003cstrong data-start=\"208\" data-end=\"233\"\u003e“AC-ANSCHLUSS-PLATTE”\u003c\/strong\u003e. It is the \u003cstrong data-start=\"245\" data-end=\"310\"\u003econnection, switching, and filtering board for the AC section\u003c\/strong\u003e, installed between the inverter's conversion stage and the grid connection.\u003cbr\u003eThe board integrates numerous power and control components, including \u003cstrong data-start=\"457\" data-end=\"565\"\u003eL1-L3 inductors, filter capacitors, K1-K8 relays, precharge\/protection components, and control circuitry\u003c\/strong\u003e, as well as the three-phase \u003cstrong data-start=\"594\" data-end=\"608\"\u003eL1-L2-L3-N\u003c\/strong\u003e terminal block visible on the front side.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"651\" data-end=\"681\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"658\" data-end=\"681\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"682\" data-end=\"1172\"\u003e\n\u003cli data-start=\"682\" data-end=\"708\"\u003e\n\u003cstrong data-start=\"684\" data-end=\"701\"\u003eManufacturer:\u003c\/strong\u003e KOSTAL\u003c\/li\u003e\n\u003cli data-start=\"709\" data-end=\"763\"\u003e\n\u003cstrong data-start=\"711\" data-end=\"727\"\u003eApplication:\u003c\/strong\u003e \u003cstrong data-start=\"728\" data-end=\"741\"\u003ePIKO 10.1\u003c\/strong\u003e photovoltaic inverter\u003c\/li\u003e\n\u003cli data-start=\"764\" data-end=\"796\"\u003e\n\u003cstrong data-start=\"766\" data-end=\"784\"\u003eConfiguration:\u003c\/strong\u003e Three-phase\u003c\/li\u003e\n\u003cli data-start=\"797\" data-end=\"843\"\u003e\n\u003cstrong data-start=\"799\" data-end=\"819\"\u003ePCB designation:\u003c\/strong\u003e \u003cstrong data-start=\"820\" data-end=\"843\"\u003eAC-ANSCHLUSS-PLATTE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"844\" data-end=\"883\"\u003e\n\u003cstrong data-start=\"846\" data-end=\"855\"\u003eType:\u003c\/strong\u003e AC power \/ connection board\u003c\/li\u003e\n\u003cli data-start=\"884\" data-end=\"947\"\u003e\n\u003cstrong data-start=\"886\" data-end=\"899\"\u003eFunction:\u003c\/strong\u003e AC section management, switching, and filtering\u003c\/li\u003e\n\u003cli data-start=\"948\" data-end=\"975\"\u003e\n\u003cstrong data-start=\"950\" data-end=\"964\"\u003eInductors:\u003c\/strong\u003e L1, L2, L3\u003c\/li\u003e\n\u003cli data-start=\"976\" data-end=\"1001\"\u003e\n\u003cstrong data-start=\"978\" data-end=\"995\"\u003ePower relays:\u003c\/strong\u003e K1–K8\u003c\/li\u003e\n\u003cli data-start=\"1002\" data-end=\"1021\"\u003eFilter capacitors\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1050\"\u003eEMI suppression components\u003c\/li\u003e\n\u003cli data-start=\"1051\" data-end=\"1085\"\u003eMeasurement and control circuits\u003c\/li\u003e\n\u003cli data-start=\"1086\" data-end=\"1126\"\u003eAC terminal block \u003cstrong data-start=\"1106\" data-end=\"1126\"\u003eL1 \/ L2 \/ L3 \/ N\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1127\" data-end=\"1172\"\u003eAuxiliary connectors and connection cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1173\" data-end=\"1198\"\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong data-start=\"1180\" data-end=\"1198\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1199\" data-end=\"1509\"\u003e\n\u003cli data-start=\"1199\" data-end=\"1252\"\u003eConnection of the inverter's AC section to the grid\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1284\"\u003eThree-phase current filtering\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1328\"\u003eReduction of electromagnetic interference\u003c\/li\u003e\n\u003cli data-start=\"1329\" data-end=\"1356\"\u003eGrid switching via relays\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1394\"\u003eManagement of phases L1, L2, and L3\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1444\"\u003eManagement of power-section switching functions\u003c\/li\u003e\n\u003cli data-start=\"1445\" data-end=\"1509\"\u003eSupport for protection and control circuits of the AC section.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1510\" data-end=\"1542\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"1517\" data-end=\"1542\"\u003ePurpose and Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1543\" data-end=\"1994\"\u003eThe \u003cstrong data-start=\"1547\" data-end=\"1570\"\u003eAC-Anschluss-Platte\u003c\/strong\u003e is one of the main modules of the PIKO 10.1 AC section.\u003cbr\u003eThe three \u003cstrong data-start=\"1637\" data-end=\"1656\"\u003eL1-L3 inductors\u003c\/strong\u003e, together with the capacitors on the board, form the filtering system for the three-phase output. The \u003cstrong data-start=\"1759\" data-end=\"1775\"\u003eK1-K8 relays\u003c\/strong\u003e perform switching and electrical-path management functions during the inverter's various operating conditions.\u003cbr\u003eThe presence of the \u003cstrong data-start=\"1907\" data-end=\"1921\"\u003eL1-L2-L3-N\u003c\/strong\u003e terminal block clearly identifies the three-phase AC section connection.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"1995\" data-end=\"2019\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"2002\" data-end=\"2019\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2020\" data-end=\"2050\"\u003eThe board is intended for the:\u003c\/p\u003e\n\u003cul data-start=\"2051\" data-end=\"2336\"\u003e\n\u003cli data-start=\"2051\" data-end=\"2336\"\u003e\n\u003cstrong data-start=\"2053\" data-end=\"2085\"\u003eKOSTAL PIKO 10.1 three-phase\u003c\/strong\u003e\u003cbr\u003eCompatibility must be verified by comparing \u003cstrong data-start=\"2130\" data-end=\"2219\"\u003ePCB code, revision, component layout, connectors, and internal inverter configuration\u003c\/strong\u003e.\u003cbr\u003eIt is important to distinguish it from the other PIKO 10.1 boards, such as the control board and DC-section boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2337\" data-end=\"2375\"\u003e\u003cspan role=\"text\"\u003e⚠️ \u003cstrong data-start=\"2344\" data-end=\"2375\"\u003eTypical Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2376\" data-end=\"2410\"\u003eA fault in the AC board may cause:\u003c\/p\u003e\n\u003cul data-start=\"2411\" data-end=\"2904\"\u003e\n\u003cli data-start=\"2411\" data-end=\"2443\"\u003efailure to connect to the grid\u003c\/li\u003e\n\u003cli data-start=\"2444\" data-end=\"2475\"\u003efailure of AC synchronization\u003c\/li\u003e\n\u003cli data-start=\"2476\" data-end=\"2513\"\u003efailure to feed power into the grid\u003c\/li\u003e\n\u003cli data-start=\"2514\" data-end=\"2535\"\u003eprotection tripping\u003c\/li\u003e\n\u003cli data-start=\"2536\" data-end=\"2553\"\u003ephase anomalies\u003c\/li\u003e\n\u003cli data-start=\"2554\" data-end=\"2595\"\u003eAC overcurrents or abnormal AC voltages\u003c\/li\u003e\n\u003cli data-start=\"2596\" data-end=\"2624\"\u003efailure of relay switching\u003c\/li\u003e\n\u003cli data-start=\"2625\" data-end=\"2647\"\u003einductor overheating\u003c\/li\u003e\n\u003cli data-start=\"2648\" data-end=\"2668\"\u003edamaged capacitors\u003c\/li\u003e\n\u003cli data-start=\"2669\" data-end=\"2709\"\u003edeteriorated contacts or solder joints\u003c\/li\u003e\n\u003cli data-start=\"2710\" data-end=\"2904\"\u003eoverheating marks on power traces.\u003cbr\u003eThe symptoms are not necessarily attributable to the board alone: the electrical grid, IGBT stage, sensors, wiring, and control circuit must also be checked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2905\" data-end=\"2942\"\u003e\u003cspan role=\"text\"\u003e🚨 \u003cstrong data-start=\"2912\" data-end=\"2942\"\u003ePossible Associated Errors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2943\" data-end=\"2985\"\u003ePossible inverter indications may concern:\u003c\/p\u003e\n\u003cul data-start=\"2986\" data-end=\"3234\"\u003e\n\u003cli data-start=\"2986\" data-end=\"3000\"\u003egrid voltage\u003c\/li\u003e\n\u003cli data-start=\"3001\" data-end=\"3017\"\u003egrid frequency\u003c\/li\u003e\n\u003cli data-start=\"3018\" data-end=\"3041\"\u003ephase loss or anomaly\u003c\/li\u003e\n\u003cli data-start=\"3042\" data-end=\"3074\"\u003efailure to connect to the grid\u003c\/li\u003e\n\u003cli data-start=\"3075\" data-end=\"3091\"\u003eAC overcurrent\u003c\/li\u003e\n\u003cli data-start=\"3092\" data-end=\"3234\"\u003eoutput-stage protections.\u003cbr\u003eAny error codes should be considered \u003cstrong data-start=\"3157\" data-end=\"3183\"\u003ediagnostic indications\u003c\/strong\u003e and not definitive proof that the board is faulty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3235\" data-end=\"3255\"\u003e\u003cspan role=\"text\"\u003e🔍 \u003cstrong data-start=\"3242\" data-end=\"3255\"\u003eDiagnosis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3256\" data-end=\"3291\"\u003eProfessional diagnosis may include:\u003c\/p\u003e\n\u003col data-start=\"3292\" data-end=\"3673\"\u003e\n\u003cli data-start=\"3292\" data-end=\"3350\"\u003evisual inspection of relays, capacitors, and inductors;\u003c\/li\u003e\n\u003cli data-start=\"3351\" data-end=\"3399\"\u003einspection of solder joints and power traces;\u003c\/li\u003e\n\u003cli data-start=\"3400\" data-end=\"3441\"\u003econtinuity testing of inductors L1-L3;\u003c\/li\u003e\n\u003cli data-start=\"3442\" data-end=\"3467\"\u003echecking relays K1-K8;\u003c\/li\u003e\n\u003cli data-start=\"3468\" data-end=\"3495\"\u003echecking the capacitors;\u003c\/li\u003e\n\u003cli data-start=\"3496\" data-end=\"3530\"\u003echecking connectors and cables;\u003c\/li\u003e\n\u003cli data-start=\"3531\" data-end=\"3564\"\u003echecking terminals L1-L2-L3-N;\u003c\/li\u003e\n\u003cli data-start=\"3565\" data-end=\"3611\"\u003echecking for short circuits between phases;\u003c\/li\u003e\n\u003cli data-start=\"3612\" data-end=\"3673\"\u003efunctional testing of the board installed in the inverter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 dir=\"auto\" data-start=\"3674\" data-end=\"3720\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3682\" data-end=\"3720\"\u003eCommon Services in Case of Failure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3721\" data-end=\"3974\"\u003e\n\u003cli data-start=\"3721\" data-end=\"3746\"\u003ePower Board diagnostics\u003c\/li\u003e\n\u003cli data-start=\"3747\" data-end=\"3765\"\u003eInductor testing\u003c\/li\u003e\n\u003cli data-start=\"3766\" data-end=\"3784\"\u003eRelay inspection\u003c\/li\u003e\n\u003cli data-start=\"3785\" data-end=\"3804\"\u003eCapacitor testing\u003c\/li\u003e\n\u003cli data-start=\"3805\" data-end=\"3829\"\u003ePower-trace inspection\u003c\/li\u003e\n\u003cli data-start=\"3830\" data-end=\"3856\"\u003eSolder-joint restoration\u003c\/li\u003e\n\u003cli data-start=\"3857\" data-end=\"3876\"\u003eWiring inspection\u003c\/li\u003e\n\u003cli data-start=\"3877\" data-end=\"3905\"\u003eComplete board replacement\u003c\/li\u003e\n\u003cli data-start=\"3906\" data-end=\"3974\"\u003eRecovery as an original spare part from a decommissioned inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3975\" data-end=\"3999\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3983\" data-end=\"3999\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4000\" data-end=\"4013\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul data-start=\"4014\" data-end=\"4220\"\u003e\n\u003cli data-start=\"4014\" data-end=\"4056\"\u003erepair of \u003cstrong data-start=\"4026\" data-end=\"4046\"\u003eKOSTAL PIKO 10.1\u003c\/strong\u003e inverters\u003c\/li\u003e\n\u003cli data-start=\"4057\" data-end=\"4081\"\u003eAC-section maintenance\u003c\/li\u003e\n\u003cli data-start=\"4082\" data-end=\"4122\"\u003ereplacement of the AC-Anschluss-Platte\u003c\/li\u003e\n\u003cli data-start=\"4123\" data-end=\"4166\"\u003erestoration of three-phase PIKO inverters\u003c\/li\u003e\n\u003cli data-start=\"4167\" data-end=\"4220\"\u003erecovery of photovoltaic equipment for spare parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4221\" data-end=\"4250\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"4229\" data-end=\"4250\"\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4251\" data-end=\"4437\"\u003e\u003cstrong data-start=\"4251\" data-end=\"4265\"\u003eUsed board\u003c\/strong\u003e, as shown in the photographs, with signs of handling and previous use.\u003cbr\u003e\u003cstrong data-start=\"4337\" data-end=\"4385\"\u003eCables and connectors connected to the board\u003c\/strong\u003e are present, together with the original components.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"4438\" data-end=\"4465\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"4445\" data-end=\"4465\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4466\" data-end=\"4655\"\u003e\n\u003cli data-start=\"4466\" data-end=\"4512\"\u003e1 × \u003cstrong data-start=\"4472\" data-end=\"4512\"\u003eKOSTAL PIKO 10.1 AC-Anschluss-Platte\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4513\" data-end=\"4545\"\u003eComplete board with components\u003c\/li\u003e\n\u003cli data-start=\"4546\" data-end=\"4609\"\u003eRelays, inductors, and capacitors as shown in the photographs\u003c\/li\u003e\n\u003cli data-start=\"4610\" data-end=\"4655\"\u003eWiring and connectors present on the board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4656\" data-end=\"4674\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"4663\" data-end=\"4674\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4675\" data-end=\"5314\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"4675\" data-end=\"4757\"\u003eKOSTAL PIKO 10.1 three-phase AC power \/ connection board – AC-Anschluss-Platte\u003c\/strong\u003e, intended for management of the inverter's AC output section. It integrates \u003cstrong data-start=\"4834\" data-end=\"4922\"\u003ethree-phase L1-L2-L3 filtering, K1-K8 power relays, capacitors, and control circuits\u003c\/strong\u003e, with \u003cstrong data-start=\"4929\" data-end=\"4943\"\u003eL1-L2-L3-N\u003c\/strong\u003e terminal block.\u003cbr\u003eIt is a power component and not simply a filter board; for this reason, it has greater value as a \u003cstrong data-start=\"5058\" data-end=\"5090\"\u003ecomplete original spare part\u003c\/strong\u003e for PIKO 10.1 maintenance.\u003cbr\u003e\u003cstrong data-start=\"5118\" data-end=\"5134\"\u003eSafety Note:\u003c\/strong\u003e The board operates in the AC power section. Any intervention must be carried out by qualified personnel, with the inverter completely disconnected and absence of voltage verified.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden has-[\u0026gt;_:empty]:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kostal Piko","offers":[{"title":"Default Title","offer_id":54976287146317,"sku":null,"price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7100.jpg?v=1791382440","url":"https:\/\/greenenergy-repair.com\/ro\/products\/kostal-piko-10-1-ac-power-board-3-phase","provider":"Green Energy","version":"1.0","type":"link"}