everything works. We also provide a warranty on the components. FAQ (SBit)
1️⃣ Overview
The ABB Power-One PVI-AEC-EVO v2.0 is a data logger for monitoring photovoltaic (PV) systems. It collects performance and operational data from ABB Aurora inverters and allows remote monitoring, analysis, and reporting through web-based platforms.
Key features:
-
Monitors multiple Aurora inverters via RS-485 or Ethernet
-
Logs real-time energy production, voltages, currents, and inverter status
-
Provides historical data for performance analysis
-
Supports remote access via web portals or networked monitoring systems
-
Helps optimize PV system performance and detect faults
2️⃣ Safety Instructions ⚠️
-
Installation must be performed by qualified personnel only.
-
Disconnect all AC and DC power from connected inverters before wiring the data logger.
-
Avoid installing in wet, dusty, or high-temperature environments.
-
Ensure proper grounding for safety and reliable operation.
3️⃣ System Requirements
-
Compatible ABB Aurora inverters (check inverter model compatibility)
-
RS-485 or Ethernet cabling from inverters to data logger
-
Network connection for web portal or remote monitoring
-
Optional PC or laptop for configuration and local monitoring
4️⃣ Installation
A. Mounting
-
Mount the data logger on a wall or DIN rail in a dry, ventilated location.
-
Ensure accessibility for wiring and monitoring.
-
Avoid direct sunlight and moisture exposure.
B. Communication Wiring
-
RS-485 Interface:
-
Connect RS-485 A/B terminals to the inverters.
-
Use twisted pair cabling recommended for RS-485 networks.
-
Terminate the RS-485 bus with 120 Ω resistors at each end if required.
-
-
Ethernet (optional):
-
Connect the RJ45 port to the local network for internet access.
-
Assign IP addresses if needed.
-
-
Check wiring polarity and shielding for proper communication.
C. Power Supply
-
Connect the data logger to its power source (typically 12–24 V DC or 230 V AC depending on the model).
-
Verify LED indicators power-on correctly.
5️⃣ Configuration Procedure
-
Connect a PC to the data logger via Ethernet or USB.
-
Access the device configuration page using a web browser (IP address provided in the manual).
-
Set up inverter network settings (RS-485 addresses, baud rate).
-
Configure connection to web portal or local monitoring software.
-
Test communication with each inverter to ensure data logging is functional.
6️⃣ Monitoring & Operation
-
Real-time Monitoring: View inverter status, power output, voltages, and currents.
-
Historical Data: Access daily, monthly, and yearly energy statistics.
-
Fault Logging: Records inverter faults and events for troubleshooting.
-
Remote Access: View system performance remotely via web portal or compatible monitoring software.
7️⃣ Maintenance
-
Keep the data logger clean and free from dust and moisture.
-
Inspect RS-485 and Ethernet connections periodically.
-
Check LED status indicators for proper operation.
-
Update firmware via the ABB portal when prompted to maintain compatibility and security.
8️⃣ Troubleshooting
| Symptom | Possible Cause | Action |
|---|---|---|
| No communication with inverter | RS-485 wiring issue | Verify A/B polarity and connections |
| No data on web portal | Network or Internet issue | Check Ethernet connection and router settings |
| Error LED on logger | Hardware fault or short | Contact ABB-certified technician |
| Intermittent data | Electrical noise or excessive cable length | Use twisted pair cables, proper grounding, reduce RS-485 segment length |
9️⃣ Shutdown Procedure
-
Power off the data logger.
-
Disconnect RS-485 and Ethernet cables if performing maintenance.
-
Ensure connected inverters continue normal operation.
Technical Summary
-
Interface: RS-485 for inverter communication
-
Optional Ethernet for portal access
-
Power Supply: 12–24 V DC or 230 V AC (model dependent)
-
Compatible with: ABB Aurora inverters
-
Mounting: Wall or DIN rail
-
Data Access: Web portal, local monitoring software
Got a question?
Don't be a stranger.

Shopping Safely
At our Green Energy store, we prioritize your safety and security. Here's how we ensure a secure shopping experience:
1. Secure Transactions: We use advanced encryption to protect your personal and payment information, ensuring it is safely transmitted and safeguarded.
2. Trusted Payment Gateways: Our store integrates with trusted payment gateways, ensuring your transactions are processed securely and efficiently.
3. Data Privacy: Your privacy is our top priority. We follow strict data protection policies to keep your personal information confidential and secure.
4. Secure Platform: Shopify provides robust security features and continuous monitoring against vulnerabilities, ensuring a safe shopping environment.
5. Verified Merchants: We are a verified merchant on Shopify, committed to providing authentic and high-quality products.
6. Transparent Policies: Our clear return, refund, and shipping policies provide peace of mind, knowing we stand behind our products.
7. Customer Support: Our dedicated customer support team is ready to assist with any concerns or questions you may have.
Shop confidently at our Shopify store, where your safety and satisfaction are our top priorities.
🔒 Warranty Terms and Conditions
By placing an order, you acknowledge and agree to the following warranty policy:
✅ 1-Year Warranty for Inverters
- All solar inverter units come with a 1-year warranty from the date of purchase.
- Each unit is fully inspected and tested before shipment to ensure proper functionality.
🔧 What the Warranty Covers
- The warranty covers defects and malfunctions that occur during standard operation.
- This includes the inverter as a whole and its internal components and circuit boards.
- If any issue arises within the warranty period, we will repair or replace the defective part or product, in line with our warranty policy.
🛠 Warranty for Separate Components
- For individual internal circuit boards, components, and repair kits ordered separately, a 6-month warranty applies from the date of purchase.
- Within this period, any functional failure will result in a free replacement as per our warranty terms.
⚠️ What the Warranty Does Not Cover
- The warranty does not apply in the following cases
- Improper installation by the customer or third parties
- Network overvoltage
- Lightning strikes or other environmental/external damage
❗ Please ensure correct installation by a qualified technician. Improper connection or handling voids the warranty.
€550,00 EUR