{"product_id":"abb-sace-tmax-t1b-160-circuit-breaker-80-a-3-pole-690-v-ac-thermal-magnetic-protection","title":"ABB SACE Tmax T1B 160 – Circuit Breaker | 80 A | 3-Pole | 690 V AC | Thermal-Magnetic Protection","description":"\u003cp data-start=\"144\" data-end=\"477\"\u003eThe \u003cstrong data-start=\"148\" data-end=\"173\"\u003eABB SACE Tmax T1B 160\u003c\/strong\u003e is a \u003cstrong data-start=\"179\" data-end=\"215\"\u003ethermal-magnetic circuit breaker\u003c\/strong\u003e designed for the protection of electrical lines and industrial installations against \u003cstrong data-start=\"301\" data-end=\"333\"\u003eoverloads and short circuits\u003c\/strong\u003e. It is part of the \u003cstrong data-start=\"353\" data-end=\"371\"\u003eTmax T1 series\u003c\/strong\u003e, offering high breaking capacity and reliable performance in low-voltage applications up to \u003cstrong data-start=\"464\" data-end=\"476\"\u003e690 V AC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"479\" data-end=\"656\"\u003eThis device is suitable for installation in \u003cstrong data-start=\"523\" data-end=\"605\"\u003eindustrial switchboards, photovoltaic systems, and power distribution networks\u003c\/strong\u003e, ensuring safe operation and effective protection.\u003c\/p\u003e\n\u003chr data-start=\"658\" data-end=\"661\"\u003e\n\u003ch3 data-start=\"663\" data-end=\"699\"\u003e⚙️ Main Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"700\" data-end=\"863\"\u003e\n\u003cli data-start=\"700\" data-end=\"779\"\u003eManufacturer \/ Series: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eABB\u003c\/span\u003e\u003c\/span\u003e – SACE Tmax T1\u003c\/li\u003e\n\u003cli data-start=\"780\" data-end=\"802\"\u003eModel: \u003cstrong data-start=\"789\" data-end=\"800\"\u003eT1B 160\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"803\" data-end=\"835\"\u003eRated current (In): \u003cstrong data-start=\"825\" data-end=\"833\"\u003e80 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"836\" data-end=\"863\"\u003eNumber of poles: \u003cstrong data-start=\"855\" data-end=\"861\"\u003e3P\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"865\" data-end=\"888\"\u003e\u003cstrong data-start=\"865\" data-end=\"888\"\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"889\" data-end=\"1057\"\u003e\n\u003cli data-start=\"889\" data-end=\"943\"\u003eRated operational voltage (Ue): \u003cstrong data-start=\"923\" data-end=\"941\"\u003eup to 690 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"944\" data-end=\"982\"\u003eInsulation voltage (Ui): \u003cstrong data-start=\"971\" data-end=\"980\"\u003e800 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"983\" data-end=\"1029\"\u003eImpulse withstand voltage (Uimp): \u003cstrong data-start=\"1019\" data-end=\"1027\"\u003e8 kV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1030\" data-end=\"1057\"\u003eFrequency: \u003cstrong data-start=\"1043\" data-end=\"1055\"\u003e50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1059\" data-end=\"1062\"\u003e\n\u003ch3 data-start=\"1064\" data-end=\"1093\"\u003e⚡ Breaking Capacity (Icu)\u003c\/h3\u003e\n\u003cul data-start=\"1094\" data-end=\"1207\"\u003e\n\u003cli data-start=\"1094\" data-end=\"1115\"\u003e\u003cstrong data-start=\"1096\" data-end=\"1113\"\u003e25 kA @ 230 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1116\" data-end=\"1143\"\u003e\u003cstrong data-start=\"1118\" data-end=\"1141\"\u003e16 kA @ 400 \/ 415 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1165\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1163\"\u003e10 kA @ 440 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1166\" data-end=\"1186\"\u003e\u003cstrong data-start=\"1168\" data-end=\"1184\"\u003e8 kA @ 500 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1187\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1205\"\u003e3 kA @ 690 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1209\" data-end=\"1212\"\u003e\n\u003ch3 data-start=\"1214\" data-end=\"1252\"\u003e🔥 Thermal Protection (Adjustable)\u003c\/h3\u003e\n\u003cul data-start=\"1253\" data-end=\"1347\"\u003e\n\u003cli data-start=\"1253\" data-end=\"1347\"\u003eAdjustment range (I1 at 40°C):\n\u003cul data-start=\"1290\" data-end=\"1347\"\u003e\n\u003cli data-start=\"1290\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1292\" data-end=\"1305\"\u003eMin: 56 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1327\"\u003e\u003cstrong data-start=\"1312\" data-end=\"1325\"\u003eMed: 68 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1330\" data-end=\"1347\"\u003e\u003cstrong data-start=\"1332\" data-end=\"1345\"\u003eMax: 80 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1349\" data-end=\"1352\"\u003e\n\u003ch3 data-start=\"1354\" data-end=\"1395\"\u003e⚡ Magnetic Protection (Instantaneous)\u003c\/h3\u003e\n\u003cul data-start=\"1396\" data-end=\"1463\"\u003e\n\u003cli data-start=\"1396\" data-end=\"1463\"\u003e\n\u003cstrong data-start=\"1398\" data-end=\"1411\"\u003eI3: 800 A\u003c\/strong\u003e (instantaneous trip for short circuit protection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1465\" data-end=\"1468\"\u003e\n\u003ch3 data-start=\"1470\" data-end=\"1502\"\u003e🔌 Accessories \u0026amp; Connections\u003c\/h3\u003e\n\u003cp data-start=\"1504\" data-end=\"1531\"\u003e\u003cstrong data-start=\"1504\" data-end=\"1531\"\u003eCompatible accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1532\" data-end=\"1663\"\u003e\n\u003cli data-start=\"1532\" data-end=\"1582\"\u003eShunt Opening Release (\u003cstrong data-start=\"1557\" data-end=\"1564\"\u003eSOR\u003c\/strong\u003e): 24–30 V AC\/DC\u003c\/li\u003e\n\u003cli data-start=\"1583\" data-end=\"1617\"\u003eUndervoltage Release (\u003cstrong data-start=\"1607\" data-end=\"1614\"\u003eUVR\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1618\" data-end=\"1663\"\u003eAuxiliary contacts (\u003cstrong data-start=\"1640\" data-end=\"1647\"\u003eAUX\u003c\/strong\u003e): 250 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1665\" data-end=\"1684\"\u003e\u003cstrong data-start=\"1665\" data-end=\"1684\"\u003eCable sections:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1685\" data-end=\"1776\"\u003e\n\u003cli data-start=\"1685\" data-end=\"1712\"\u003eRigid: \u003cstrong data-start=\"1694\" data-end=\"1710\"\u003e2.5 – 70 mm²\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1713\" data-end=\"1743\"\u003eFlexible: \u003cstrong data-start=\"1725\" data-end=\"1741\"\u003e2.5 – 50 mm²\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1745\" data-end=\"1776\"\u003eTightening torque: \u003cstrong data-start=\"1766\" data-end=\"1774\"\u003e7 Nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1778\" data-end=\"1781\"\u003e\n\u003ch3 data-start=\"1783\" data-end=\"1802\"\u003e🧩 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1803\" data-end=\"1979\"\u003e\n\u003cli data-start=\"1803\" data-end=\"1835\"\u003eIndustrial electrical panels\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1893\"\u003ePhotovoltaic systems (AC\/DC protection on power side)\u003c\/li\u003e\n\u003cli data-start=\"1894\" data-end=\"1936\"\u003eLow-voltage power distribution systems\u003c\/li\u003e\n\u003cli data-start=\"1937\" data-end=\"1979\"\u003eIndustrial machinery and installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1981\" data-end=\"1984\"\u003e\n\u003ch3 data-start=\"1986\" data-end=\"2006\"\u003e✅ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"2007\" data-end=\"2165\"\u003e\n\u003cli data-start=\"2007\" data-end=\"2040\"\u003eOverload protection (thermal)\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2080\"\u003eShort-circuit protection (magnetic)\u003c\/li\u003e\n\u003cli data-start=\"2081\" data-end=\"2117\"\u003eManual disconnection of the line\u003c\/li\u003e\n\u003cli data-start=\"2118\" data-end=\"2165\"\u003eIntegration with control and safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2167\" data-end=\"2170\"\u003e\n\u003ch3 data-start=\"2172\" data-end=\"2184\"\u003e📌 Notes\u003c\/h3\u003e\n\u003cp data-start=\"2186\" data-end=\"2342\"\u003eCompliant with \u003cstrong data-start=\"2201\" data-end=\"2216\"\u003eIEC 60947-2\u003c\/strong\u003e, this device is designed for use in industrial environments requiring high standards of safety, reliability, and performance.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53765154242893,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5477.jpg?v=1776873776","url":"https:\/\/greenenergy-repair.com\/ro\/products\/abb-sace-tmax-t1b-160-circuit-breaker-80-a-3-pole-690-v-ac-thermal-magnetic-protection","provider":"Green Energy","version":"1.0","type":"link"}