{"product_id":"wohner-aes-3x38-art-31113-3-pole-switch-disconnector-fuse-holder-10x38-mm-32a-690v-ac-din-rail-iec-60947-3","title":"Wöhner AES 3x38 Art. 31113 – 3-Pole Switch-Disconnector Fuse Holder 10x38 mm | 32A | 690V AC | DIN Rail | IEC 60947-3","description":"\u003cp data-start=\"196\" data-end=\"410\"\u003eThe \u003cstrong data-start=\"200\" data-end=\"239\"\u003eWöhner AES 3x38 – Article No. 31113\u003c\/strong\u003e is a \u003cstrong data-start=\"245\" data-end=\"299\"\u003ethree-pole modular switch-disconnector fuse holder\u003c\/strong\u003e designed for cylindrical \u003cstrong data-start=\"325\" data-end=\"343\"\u003e10x38 mm fuses\u003c\/strong\u003e, suitable for low-voltage distribution systems up to \u003cstrong data-start=\"397\" data-end=\"409\"\u003e690 V AC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"412\" data-end=\"674\"\u003ePart of the professional Wöhner product range, this device ensures high operational reliability, safe switching performance, and robust mechanical construction, making it ideal for industrial applications, automation systems, and three-phase distribution panels.\u003c\/p\u003e\n\u003cp data-start=\"676\" data-end=\"840\"\u003eThe design allows \u003cstrong data-start=\"694\" data-end=\"734\"\u003esafe manual isolation of the circuit\u003c\/strong\u003e and effective protection against overloads and short circuits using \u003cstrong data-start=\"803\" data-end=\"839\"\u003egG, aM, or equivalent fuse types\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"842\" data-end=\"845\"\u003e\n\u003ch2 data-start=\"847\" data-end=\"879\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"881\" data-end=\"1259\"\u003e\u003cstrong data-start=\"881\" data-end=\"891\"\u003eBrand:\u003c\/strong\u003e Wöhner\u003cbr data-start=\"898\" data-end=\"901\"\u003e\u003cstrong data-start=\"901\" data-end=\"911\"\u003eModel:\u003c\/strong\u003e AES 3x38\u003cbr data-start=\"920\" data-end=\"923\"\u003e\u003cstrong data-start=\"923\" data-end=\"942\"\u003eArticle Number:\u003c\/strong\u003e 31 113\u003cbr data-start=\"949\" data-end=\"952\"\u003e\u003cstrong data-start=\"952\" data-end=\"961\"\u003eType:\u003c\/strong\u003e Modular switch-disconnector fuse holder\u003cbr data-start=\"1001\" data-end=\"1004\"\u003e\u003cstrong data-start=\"1004\" data-end=\"1024\"\u003eNumber of poles:\u003c\/strong\u003e 3\u003cbr data-start=\"1026\" data-end=\"1029\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1043\"\u003eFuse size:\u003c\/strong\u003e 10x38 mm\u003cbr data-start=\"1052\" data-end=\"1055\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1068\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003cbr data-start=\"1077\" data-end=\"1080\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1105\"\u003eDegree of protection:\u003c\/strong\u003e IP20 (when installed in enclosure)\u003cbr data-start=\"1140\" data-end=\"1143\"\u003e\u003cstrong data-start=\"1143\" data-end=\"1156\"\u003eMaterial:\u003c\/strong\u003e High-resistance self-extinguishing thermoplastic\u003cbr data-start=\"1205\" data-end=\"1208\"\u003e\u003cstrong data-start=\"1208\" data-end=\"1223\"\u003eProduction:\u003c\/strong\u003e Made in Germany\u003cbr data-start=\"1239\" data-end=\"1242\"\u003e\u003cstrong data-start=\"1242\" data-end=\"1254\"\u003eMarking:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003ch3 data-start=\"1261\" data-end=\"1285\"\u003e🔌 Electrical Data\u003c\/h3\u003e\n\u003cul data-start=\"1287\" data-end=\"1419\"\u003e\n\u003cli data-start=\"1287\" data-end=\"1314\"\u003e\n\u003cp data-start=\"1289\" data-end=\"1314\"\u003eRated current: \u003cstrong data-start=\"1304\" data-end=\"1312\"\u003e32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1315\" data-end=\"1354\"\u003e\n\u003cp data-start=\"1317\" data-end=\"1354\"\u003eRated voltage: \u003cstrong data-start=\"1332\" data-end=\"1352\"\u003e400 V \/ 690 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1355\" data-end=\"1382\"\u003e\n\u003cp data-start=\"1357\" data-end=\"1382\"\u003eFrequency: \u003cstrong data-start=\"1368\" data-end=\"1380\"\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1383\" data-end=\"1419\"\u003e\n\u003cp data-start=\"1385\" data-end=\"1419\"\u003eUtilization category: \u003cstrong data-start=\"1407\" data-end=\"1417\"\u003eAC-22B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1421\" data-end=\"1450\"\u003e📜 Applicable Standards\u003c\/h3\u003e\n\u003cul data-start=\"1452\" data-end=\"1485\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1467\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1467\"\u003eIEC 60947-3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1468\" data-end=\"1485\"\u003e\n\u003cp data-start=\"1470\" data-end=\"1485\"\u003eIEC 60269-2-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1487\" data-end=\"1517\"\u003e🔄 Compatible Fuse Types\u003c\/h3\u003e\n\u003cul data-start=\"1519\" data-end=\"1617\"\u003e\n\u003cli data-start=\"1519\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1521\" data-end=\"1543\"\u003egG (general purpose)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1546\" data-end=\"1569\"\u003eaM (motor protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1617\"\u003eaR \/ gR (subject to technical verification)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1619\" data-end=\"1622\"\u003e\n\u003ch2 data-start=\"1624\" data-end=\"1649\"\u003e🔎 Function \u0026amp; Safety\u003c\/h2\u003e\n\u003cp data-start=\"1651\" data-end=\"1676\"\u003eThe fuse holder allows:\u003c\/p\u003e\n\u003cp data-start=\"1678\" data-end=\"1824\"\u003e✔ Quick fuse insertion and replacement\u003cbr data-start=\"1716\" data-end=\"1719\"\u003e✔ Manual circuit disconnection\u003cbr data-start=\"1749\" data-end=\"1752\"\u003e✔ Reliable protection against overcurrents\u003cbr data-start=\"1794\" data-end=\"1797\"\u003e✔ High operational safety\u003c\/p\u003e\n\u003cp data-start=\"1826\" data-end=\"1976\"\u003eThe lever-operated mechanism ensures controlled opening and simplified maintenance, with a compact structure suitable for modular distribution boards.\u003c\/p\u003e\n\u003chr data-start=\"1978\" data-end=\"1981\"\u003e\n\u003ch2 data-start=\"1983\" data-end=\"2003\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"2005\" data-end=\"2231\"\u003e✔ Three-phase industrial electrical panels\u003cbr data-start=\"2047\" data-end=\"2050\"\u003e✔ Low-voltage distribution systems\u003cbr data-start=\"2084\" data-end=\"2087\"\u003e✔ Motor line protection\u003cbr data-start=\"2110\" data-end=\"2113\"\u003e✔ Photovoltaic systems (with appropriate fuses)\u003cbr data-start=\"2160\" data-end=\"2163\"\u003e✔ Automation systems\u003cbr data-start=\"2183\" data-end=\"2186\"\u003e✔ Commercial and manufacturing environments\u003c\/p\u003e\n\u003chr data-start=\"2233\" data-end=\"2236\"\u003e\n\u003ch2 data-start=\"2238\" data-end=\"2258\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2260\" data-end=\"2458\"\u003e\n\u003cli data-start=\"2260\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2262\" data-end=\"2290\"\u003eStandard DIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2291\" data-end=\"2354\"\u003e\n\u003cp data-start=\"2293\" data-end=\"2354\"\u003eCopper conductor connection according to IEC specifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2355\" data-end=\"2397\"\u003e\n\u003cp data-start=\"2357\" data-end=\"2397\"\u003eSuitable for 10x38 mm fuses up to 32 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2398\" data-end=\"2458\"\u003e\n\u003cp data-start=\"2400\" data-end=\"2458\"\u003eTightening torque according to manufacturer instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2460\" data-end=\"2463\"\u003e\n\u003ch2 data-start=\"2465\" data-end=\"2482\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2484\" data-end=\"2576\"\u003eUsed product in good cosmetic and structural condition.\u003cbr data-start=\"2539\" data-end=\"2542\"\u003eSupplied as shown in the images.\u003c\/p\u003e\n\u003chr data-start=\"2578\" data-end=\"2581\"\u003e\n\u003ch2 data-start=\"2583\" data-end=\"2600\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cp data-start=\"2602\" data-end=\"2806\"\u003e✔ German Wöhner manufacturing quality\u003cbr data-start=\"2639\" data-end=\"2642\"\u003e✔ Rated voltage up to 690 V AC\u003cbr data-start=\"2672\" data-end=\"2675\"\u003e✔ Compact three-pole configuration\u003cbr data-start=\"2709\" data-end=\"2712\"\u003e✔ High industrial reliability\u003cbr data-start=\"2741\" data-end=\"2744\"\u003e✔ Easy maintenance\u003cbr data-start=\"2762\" data-end=\"2765\"\u003e✔ Ideal for three-phase line protection\u003c\/p\u003e","brand":"Wöhner","offers":[{"title":"Default Title","offer_id":53426043224397,"sku":null,"price":15.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4898.jpg?v=1772012938","url":"https:\/\/greenenergy-repair.com\/products\/wohner-aes-3x38-art-31113-3-pole-switch-disconnector-fuse-holder-10x38-mm-32a-690v-ac-din-rail-iec-60947-3","provider":"Green Energy","version":"1.0","type":"link"}