{"product_id":"thies-clima-4-3519-00-161-0-10-v-anemometer-50-m-s","title":"Thies Clima 4.3519.00.161 | 0–10 V Anemometer | 50 m\/s","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-3\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-3\" data-turn-id-container=\"request-69d4da03-d18c-832a-8303-bf8cb496962a-3\" data-testid=\"conversation-turn-12\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" data-dil-talvt-response-state=\"complete\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 [\u0026amp;\u0026gt;div:has([data-free-thinking-preview-answer=true])+:is(.text-message,.relative:has(\u0026gt;.text-message))]:-mt-2 grow\"\u003e\n\u003cdiv class=\"TzNmiG_container gap-4 [\u0026amp;\u0026gt;div:has([data-free-thinking-preview-answer=true])+:is(.text-message,.relative:has(\u0026gt;.text-message))]:-mt-2\" data-streaming-response-group=\"\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"577c7c5f-5f69-4e01-af42-89fe9f4e9da1\" data-markdown-talvt-message-id=\"577c7c5f-5f69-4e01-af42-89fe9f4e9da1\" data-markdown-talvt-render-state=\"ready\" dir=\"auto\" data-message-model-slug=\"gpt-5-6\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"fbskMG_root LR5Y_W_content markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch3 dir=\"auto\" data-start=\"61\" data-end=\"83\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"68\" data-end=\"83\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"84\" data-end=\"665\"\u003e\u003cstrong data-start=\"84\" data-end=\"100\"\u003eNew product.\u003c\/strong\u003e Thies Clima \u003cstrong data-start=\"113\" data-end=\"155\"\u003eWind Transmitter Compact 4.3519.00.161\u003c\/strong\u003e, professional anemometer for measuring wind speed with \u003cstrong data-start=\"211\" data-end=\"235\"\u003e0–10 V analog output\u003c\/strong\u003e.\u003cbr\u003eThe device is designed for meteorological data acquisition systems, weather stations, environmental monitoring systems and industrial applications. The photographed model is identified by the label as \u003cstrong data-start=\"438\" data-end=\"455\"\u003e4.3519.00.161\u003c\/strong\u003e and features a \u003cstrong data-start=\"471\" data-end=\"491\"\u003e12 m fixed cable\u003c\/strong\u003e. The manufacturer specifies a measuring range of \u003cstrong data-start=\"541\" data-end=\"555\"\u003e0.5–50 m\/s\u003c\/strong\u003e, electronic power supply of \u003cstrong data-start=\"584\" data-end=\"609\"\u003e13–30 V DC or 24 V AC\u003c\/strong\u003e, \u003cstrong data-start=\"611\" data-end=\"619\"\u003eIP55\u003c\/strong\u003e protection and an integrated \u003cstrong data-start=\"649\" data-end=\"664\"\u003e20 W heater\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"666\" data-end=\"696\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"673\" data-end=\"696\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"697\" data-end=\"1298\"\u003e\n\u003cli data-start=\"697\" data-end=\"739\"\u003e\n\u003cstrong data-start=\"699\" data-end=\"709\"\u003eBrand:\u003c\/strong\u003e \u003cstrong data-start=\"710\" data-end=\"739\"\u003eThies Clima \/ Adolf Thies\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"740\" data-end=\"782\"\u003e\n\u003cstrong data-start=\"742\" data-end=\"753\"\u003eSeries:\u003c\/strong\u003e \u003cstrong data-start=\"754\" data-end=\"782\"\u003eWind Transmitter Compact\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"783\" data-end=\"813\"\u003e\n\u003cstrong data-start=\"785\" data-end=\"795\"\u003eModel:\u003c\/strong\u003e \u003cstrong data-start=\"796\" data-end=\"813\"\u003e4.3519.00.161\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"814\" data-end=\"865\"\u003e\n\u003cstrong data-start=\"816\" data-end=\"825\"\u003eType:\u003c\/strong\u003e \u003cstrong data-start=\"826\" data-end=\"865\"\u003eanemometer \/ wind speed transmitter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"866\" data-end=\"903\"\u003e\n\u003cstrong data-start=\"868\" data-end=\"888\"\u003eMeasuring range:\u003c\/strong\u003e \u003cstrong data-start=\"889\" data-end=\"903\"\u003e0.5–50 m\/s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"935\"\u003e\n\u003cstrong data-start=\"906\" data-end=\"924\"\u003eAnalog output:\u003c\/strong\u003e \u003cstrong data-start=\"925\" data-end=\"935\"\u003e0–10 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"936\" data-end=\"971\"\u003e\n\u003cstrong data-start=\"938\" data-end=\"962\"\u003eMinimum output load:\u003c\/strong\u003e \u003cstrong data-start=\"963\" data-end=\"971\"\u003e1 kΩ\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"972\" data-end=\"1028\"\u003e\n\u003cstrong data-start=\"974\" data-end=\"1002\"\u003eElectronic power supply:\u003c\/strong\u003e \u003cstrong data-start=\"1003\" data-end=\"1028\"\u003e13–30 V DC or 24 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1029\" data-end=\"1056\"\u003e\n\u003cstrong data-start=\"1031\" data-end=\"1047\"\u003eFixed cable:\u003c\/strong\u003e \u003cstrong data-start=\"1048\" data-end=\"1056\"\u003e12 m\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1057\" data-end=\"1092\"\u003e\n\u003cstrong data-start=\"1059\" data-end=\"1069\"\u003eCable:\u003c\/strong\u003e \u003cstrong data-start=\"1070\" data-end=\"1092\"\u003eLiyCY 5 × 0.25 mm²\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1093\" data-end=\"1126\"\u003e\n\u003cstrong data-start=\"1095\" data-end=\"1117\"\u003eProtection rating:\u003c\/strong\u003e \u003cstrong data-start=\"1118\" data-end=\"1126\"\u003eIP55\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1127\" data-end=\"1168\"\u003e\n\u003cstrong data-start=\"1129\" data-end=\"1153\"\u003eAmbient temperature:\u003c\/strong\u003e \u003cstrong data-start=\"1154\" data-end=\"1168\"\u003e−40…+70 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1169\" data-end=\"1213\"\u003e\n\u003cstrong data-start=\"1171\" data-end=\"1186\"\u003eDimensions:\u003c\/strong\u003e approx. \u003cstrong data-start=\"1195\" data-end=\"1213\"\u003eØ 135 × 165 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1214\" data-end=\"1247\"\u003e\n\u003cstrong data-start=\"1216\" data-end=\"1227\"\u003eWeight:\u003c\/strong\u003e approx. \u003cstrong data-start=\"1236\" data-end=\"1247\"\u003e0.75 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1248\" data-end=\"1298\"\u003e\n\u003cstrong data-start=\"1250\" data-end=\"1272\"\u003eIntegrated heater:\u003c\/strong\u003e \u003cstrong data-start=\"1273\" data-end=\"1298\"\u003e24 V AC\/DC, max. 20 W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1299\" data-end=\"1324\"\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong data-start=\"1306\" data-end=\"1324\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1325\" data-end=\"1663\"\u003e\n\u003cli data-start=\"1325\" data-end=\"1364\"\u003eMeasurement of horizontal wind speed.\u003c\/li\u003e\n\u003cli data-start=\"1365\" data-end=\"1424\"\u003eConversion of wind speed into a \u003cstrong data-start=\"1399\" data-end=\"1409\"\u003e0–10 V\u003c\/strong\u003e analog signal.\u003c\/li\u003e\n\u003cli data-start=\"1425\" data-end=\"1525\"\u003eTransmission of the measured value to data loggers, PLCs, acquisition systems or weather stations.\u003c\/li\u003e\n\u003cli data-start=\"1526\" data-end=\"1593\"\u003eSensor heating for applications in cold environmental conditions.\u003c\/li\u003e\n\u003cli data-start=\"1594\" data-end=\"1663\"\u003eContinuous operation in meteorological and industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1664\" data-end=\"1696\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"1671\" data-end=\"1696\"\u003ePurpose and Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1697\" data-end=\"2132\"\u003eThe sensor uses a rotating cup system to detect wind speed. Rotation is electronically detected and converted into a signal proportional to wind speed.\u003cbr\u003eIn model \u003cstrong data-start=\"1858\" data-end=\"1875\"\u003e4.3519.00.161\u003c\/strong\u003e, the output signal is \u003cstrong data-start=\"1898\" data-end=\"1908\"\u003e0–10 V\u003c\/strong\u003e, which can be connected directly to acquisition systems equipped with a compatible analog input. The manufacturer specifies a resolution of less than \u003cstrong data-start=\"2059\" data-end=\"2070\"\u003e0.1 m\/s\u003c\/strong\u003e and an accuracy of \u003cstrong data-start=\"2090\" data-end=\"2131\"\u003e±3% of the measured value or ±0.5 m\/s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"2133\" data-end=\"2157\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"2140\" data-end=\"2157\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2158\" data-end=\"2230\"\u003eSuitable for systems equipped with a \u003cstrong data-start=\"2195\" data-end=\"2205\"\u003e0–10 V\u003c\/strong\u003e analog input, including:\u003c\/p\u003e\n\u003cul data-start=\"2231\" data-end=\"2528\"\u003e\n\u003cli data-start=\"2231\" data-end=\"2250\"\u003eweather stations;\u003c\/li\u003e\n\u003cli data-start=\"2251\" data-end=\"2266\"\u003edata loggers;\u003c\/li\u003e\n\u003cli data-start=\"2267\" data-end=\"2283\"\u003eSCADA systems;\u003c\/li\u003e\n\u003cli data-start=\"2284\" data-end=\"2291\"\u003ePLCs;\u003c\/li\u003e\n\u003cli data-start=\"2292\" data-end=\"2327\"\u003eenvironmental monitoring systems;\u003c\/li\u003e\n\u003cli data-start=\"2328\" data-end=\"2354\"\u003emeteorological stations;\u003c\/li\u003e\n\u003cli data-start=\"2355\" data-end=\"2528\"\u003eindustrial control and monitoring systems.\u003cbr\u003eElectrical compatibility must be verified according to the analog input of the receiving device and the sensor's wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2529\" data-end=\"2567\"\u003e\u003cspan role=\"text\"\u003e⚠️ \u003cstrong data-start=\"2536\" data-end=\"2567\"\u003eTypical Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2568\" data-end=\"2592\"\u003ePossible faults include:\u003c\/p\u003e\n\u003cul data-start=\"2593\" data-end=\"2855\"\u003e\n\u003cli data-start=\"2593\" data-end=\"2624\"\u003eabsence of the 0–10 V signal;\u003c\/li\u003e\n\u003cli data-start=\"2625\" data-end=\"2665\"\u003efixed signal regardless of wind speed;\u003c\/li\u003e\n\u003cli data-start=\"2666\" data-end=\"2697\"\u003eincorrect wind speed reading;\u003c\/li\u003e\n\u003cli data-start=\"2698\" data-end=\"2743\"\u003erotor friction or failure to rotate freely;\u003c\/li\u003e\n\u003cli data-start=\"2744\" data-end=\"2769\"\u003eunstable analog signal;\u003c\/li\u003e\n\u003cli data-start=\"2770\" data-end=\"2787\"\u003eheater failure;\u003c\/li\u003e\n\u003cli data-start=\"2788\" data-end=\"2855\"\u003einfiltration or deterioration caused by environmental conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2856\" data-end=\"2876\"\u003e\u003cspan role=\"text\"\u003e🔍 \u003cstrong data-start=\"2863\" data-end=\"2876\"\u003eDiagnosis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2877\" data-end=\"2900\"\u003eInspection may include:\u003c\/p\u003e\n\u003col data-start=\"2901\" data-end=\"3198\"\u003e\n\u003cli data-start=\"2901\" data-end=\"2930\"\u003echecking the power supply;\u003c\/li\u003e\n\u003cli data-start=\"2931\" data-end=\"2977\"\u003echecking free rotation of the cup assembly;\u003c\/li\u003e\n\u003cli data-start=\"2978\" data-end=\"3016\"\u003emeasuring the 0–10 V analog signal;\u003c\/li\u003e\n\u003cli data-start=\"3017\" data-end=\"3071\"\u003ecomparing actual wind speed with the output signal;\u003c\/li\u003e\n\u003cli data-start=\"3072\" data-end=\"3099\"\u003echecking the 12 m cable;\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3132\"\u003echecking the heating circuit;\u003c\/li\u003e\n\u003cli data-start=\"3133\" data-end=\"3198\"\u003echecking mechanical integrity and possible water infiltration.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 dir=\"auto\" data-start=\"3199\" data-end=\"3245\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3207\" data-end=\"3245\"\u003eCommon Services in Case of Failure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3246\" data-end=\"3465\"\u003e\n\u003cli data-start=\"3246\" data-end=\"3279\"\u003eElectrical transmitter testing.\u003c\/li\u003e\n\u003cli data-start=\"3280\" data-end=\"3316\"\u003e0–10 V analog output verification.\u003c\/li\u003e\n\u003cli data-start=\"3317\" data-end=\"3338\"\u003ePower supply check.\u003c\/li\u003e\n\u003cli data-start=\"3339\" data-end=\"3358\"\u003eCable inspection.\u003c\/li\u003e\n\u003cli data-start=\"3359\" data-end=\"3390\"\u003eRotating assembly inspection.\u003c\/li\u003e\n\u003cli data-start=\"3391\" data-end=\"3415\"\u003eHeating circuit check.\u003c\/li\u003e\n\u003cli data-start=\"3416\" data-end=\"3465\"\u003eComplete sensor replacement in case of failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3466\" data-end=\"3490\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3474\" data-end=\"3490\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3491\" data-end=\"3724\"\u003e\n\u003cli data-start=\"3491\" data-end=\"3510\"\u003eWeather stations.\u003c\/li\u003e\n\u003cli data-start=\"3511\" data-end=\"3535\"\u003eWind speed monitoring.\u003c\/li\u003e\n\u003cli data-start=\"3536\" data-end=\"3573\"\u003ePhotovoltaic and wind power plants.\u003c\/li\u003e\n\u003cli data-start=\"3574\" data-end=\"3615\"\u003eEnvironmental data acquisition systems.\u003c\/li\u003e\n\u003cli data-start=\"3616\" data-end=\"3646\"\u003eMeteorological data loggers.\u003c\/li\u003e\n\u003cli data-start=\"3647\" data-end=\"3663\"\u003eSCADA systems.\u003c\/li\u003e\n\u003cli data-start=\"3664\" data-end=\"3688\"\u003eIndustrial automation.\u003c\/li\u003e\n\u003cli data-start=\"3689\" data-end=\"3724\"\u003eAtmospheric condition monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3725\" data-end=\"3754\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"3733\" data-end=\"3754\"\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3755\" data-end=\"3970\"\u003e\u003cstrong data-start=\"3755\" data-end=\"3770\"\u003eNew product\u003c\/strong\u003e, as shown in the photographs. The sensor appears intact and is supplied with the \u003cstrong data-start=\"3852\" data-end=\"3875\"\u003eoriginal 12 m cable\u003c\/strong\u003e and original technical documentation. The packaging has cosmetic signs resulting from storage.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"3971\" data-end=\"3998\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"3978\" data-end=\"3998\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3999\" data-end=\"4199\"\u003e\n\u003cli data-start=\"3999\" data-end=\"4045\"\u003e\u003cstrong data-start=\"4001\" data-end=\"4045\"\u003e1 × Thies Clima Wind Transmitter Compact\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"4046\" data-end=\"4076\"\u003e\n\u003cstrong data-start=\"4048\" data-end=\"4058\"\u003eModel:\u003c\/strong\u003e \u003cstrong data-start=\"4059\" data-end=\"4076\"\u003e4.3519.00.161\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4077\" data-end=\"4102\"\u003eOriginal \u003cstrong data-start=\"4088\" data-end=\"4102\"\u003e12 m cable\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4103\" data-end=\"4151\"\u003eOriginal \u003cstrong data-start=\"4114\" data-end=\"4137\"\u003eInstruction for Use\u003c\/strong\u003e documentation\u003c\/li\u003e\n\u003cli data-start=\"4152\" data-end=\"4199\"\u003eStorage packaging visible in the photographs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4200\" data-end=\"4218\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"4207\" data-end=\"4218\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4219\" data-end=\"4531\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"4223\" data-end=\"4252\"\u003eThies Clima 4.3519.00.161\u003c\/strong\u003e is a professional anemometer with \u003cstrong data-start=\"4287\" data-end=\"4311\"\u003e0–10 V analog output\u003c\/strong\u003e, \u003cstrong data-start=\"4313\" data-end=\"4327\"\u003e0.5–50 m\/s\u003c\/strong\u003e measuring range, \u003cstrong data-start=\"4345\" data-end=\"4369\"\u003e13–30 V DC \/ 24 V AC\u003c\/strong\u003e power supply and a fixed 12 m cable. It is intended for weather systems, data loggers, PLCs and monitoring systems requiring an analog measurement of wind speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Thies Clima","offers":[{"title":"Default Title","offer_id":54968670617933,"sku":null,"price":420.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7088.jpg?v=1791281536","url":"https:\/\/greenenergy-repair.com\/products\/thies-clima-4-3519-00-161-0-10-v-anemometer-50-m-s","provider":"Green Energy","version":"1.0","type":"link"}