{"product_id":"sunways-at3600-lcd-display-communication-board-hmi-interface-module-for-photovoltaic-inverter","title":"Sunways AT3600 – LCD Display \u0026 Communication Board | HMI Interface Module for Photovoltaic Inverter","description":"\u003cp data-start=\"147\" data-end=\"289\"\u003eThe component shown is an original \u003cstrong data-start=\"182\" data-end=\"219\"\u003eLCD Display \u0026amp; Communication Board\u003c\/strong\u003e used in \u003cstrong data-start=\"228\" data-end=\"246\"\u003eSunways AT3600\u003c\/strong\u003e photovoltaic inverters from the AT series.\u003c\/p\u003e\n\u003cp data-start=\"291\" data-end=\"497\"\u003eThis module acts as the inverter’s \u003cstrong data-start=\"326\" data-end=\"359\"\u003eHuman Machine Interface (HMI)\u003c\/strong\u003e and allows real-time visualization of operating parameters, inverter status, production data, and fault codes of the photovoltaic system.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"520\"\u003eThe board integrates:\u003c\/p\u003e\n\u003cul data-start=\"522\" data-end=\"723\"\u003e\n\u003cli data-start=\"522\" data-end=\"545\"\u003eGraphic LCD display\u003c\/li\u003e\n\u003cli data-start=\"546\" data-end=\"584\"\u003eEmbedded management microprocessor\u003c\/li\u003e\n\u003cli data-start=\"585\" data-end=\"601\"\u003eFlash memory\u003c\/li\u003e\n\u003cli data-start=\"602\" data-end=\"629\"\u003eCommunication circuitry\u003c\/li\u003e\n\u003cli data-start=\"630\" data-end=\"656\"\u003eEthernet\/LAN interface\u003c\/li\u003e\n\u003cli data-start=\"657\" data-end=\"683\"\u003eExpansion\/service slot\u003c\/li\u003e\n\u003cli data-start=\"684\" data-end=\"723\"\u003eFront keypad and control management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"725\" data-end=\"861\"\u003eIt is responsible for communication between the user and the inverter, enabling local monitoring, diagnostics, and system configuration.\u003c\/p\u003e\n\u003chr data-start=\"863\" data-end=\"866\"\u003e\n\u003ch3 data-start=\"868\" data-end=\"889\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"891\" data-end=\"1177\"\u003e\n\u003cli data-start=\"891\" data-end=\"929\"\u003eDisplay of inverter operating data\u003c\/li\u003e\n\u003cli data-start=\"930\" data-end=\"978\"\u003eMenu navigation and configuration management\u003c\/li\u003e\n\u003cli data-start=\"979\" data-end=\"1017\"\u003ePhotovoltaic production monitoring\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1053\"\u003eAlarm and fault code indication\u003c\/li\u003e\n\u003cli data-start=\"1054\" data-end=\"1097\"\u003eCommunication with the main logic board\u003c\/li\u003e\n\u003cli data-start=\"1098\" data-end=\"1146\"\u003eLAN\/Ethernet interface for remote monitoring\u003c\/li\u003e\n\u003cli data-start=\"1147\" data-end=\"1177\"\u003eFirmware update management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1179\" data-end=\"1182\"\u003e\n\u003ch3 data-start=\"1184\" data-end=\"1215\"\u003e🔌 Role Inside the Inverter\u003c\/h3\u003e\n\u003cp data-start=\"1217\" data-end=\"1275\"\u003eInside the Sunways AT3600 system, the module functions as:\u003c\/p\u003e\n\u003cul data-start=\"1277\" data-end=\"1415\"\u003e\n\u003cli data-start=\"1277\" data-end=\"1316\"\u003eHMI (Human Machine Interface) panel\u003c\/li\u003e\n\u003cli data-start=\"1317\" data-end=\"1345\"\u003eLocal operator interface\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1380\"\u003eDiagnostic and monitoring unit\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1415\"\u003eCommunication interface module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1417\" data-end=\"1450\"\u003eThe display allows monitoring of:\u003c\/p\u003e\n\u003cul data-start=\"1452\" data-end=\"1569\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1466\"\u003eDC voltage\u003c\/li\u003e\n\u003cli data-start=\"1467\" data-end=\"1486\"\u003eAC output power\u003c\/li\u003e\n\u003cli data-start=\"1487\" data-end=\"1506\"\u003eProduced energy\u003c\/li\u003e\n\u003cli data-start=\"1507\" data-end=\"1522\"\u003eGrid status\u003c\/li\u003e\n\u003cli data-start=\"1523\" data-end=\"1538\"\u003eMPPT status\u003c\/li\u003e\n\u003cli data-start=\"1539\" data-end=\"1569\"\u003eAlarms and inverter faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1571\" data-end=\"1574\"\u003e\n\u003ch3 data-start=\"1576\" data-end=\"1609\"\u003e🔧 Visible Technical Features\u003c\/h3\u003e\n\u003cul data-start=\"1611\" data-end=\"1988\"\u003e\n\u003cli data-start=\"1611\" data-end=\"1645\"\u003eMonochrome graphic LCD display\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1691\"\u003eFlat cable connection between LCD and PCB\u003c\/li\u003e\n\u003cli data-start=\"1692\" data-end=\"1729\"\u003eFreescale ColdFire microprocessor\u003c\/li\u003e\n\u003cli data-start=\"1730\" data-end=\"1767\"\u003eSamsung memory + AMD Flash memory\u003c\/li\u003e\n\u003cli data-start=\"1768\" data-end=\"1801\"\u003eIntegrated RJ45 Ethernet port\u003c\/li\u003e\n\u003cli data-start=\"1802\" data-end=\"1833\"\u003eSD\/Card expansion interface\u003c\/li\u003e\n\u003cli data-start=\"1834\" data-end=\"1876\"\u003eFlex connectors for inverter interface\u003c\/li\u003e\n\u003cli data-start=\"1877\" data-end=\"1914\"\u003eIntegrated switching power supply\u003c\/li\u003e\n\u003cli data-start=\"1915\" data-end=\"1944\"\u003eIndustrial multilayer PCB\u003c\/li\u003e\n\u003cli data-start=\"1945\" data-end=\"1988\"\u003eSMD communication and control circuitry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1990\" data-end=\"1993\"\u003e\n\u003ch3 data-start=\"1995\" data-end=\"2014\"\u003e🛠 Applications\u003c\/h3\u003e\n\u003cul data-start=\"2016\" data-end=\"2250\"\u003e\n\u003cli data-start=\"2016\" data-end=\"2058\"\u003eReplacement of faulty inverter display\u003c\/li\u003e\n\u003cli data-start=\"2059\" data-end=\"2104\"\u003eRepair of inverter user interface systems\u003c\/li\u003e\n\u003cli data-start=\"2105\" data-end=\"2156\"\u003eRestoration of inverter communication functions\u003c\/li\u003e\n\u003cli data-start=\"2157\" data-end=\"2203\"\u003eRecovery of operational data visualization\u003c\/li\u003e\n\u003cli data-start=\"2204\" data-end=\"2250\"\u003eMaintenance of Sunways AT series inverters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2252\" data-end=\"2255\"\u003e\n\u003ch3 data-start=\"2257\" data-end=\"2289\"\u003e⚠️ Typical Faults \u0026amp; Symptoms\u003c\/h3\u003e\n\u003cp data-start=\"2291\" data-end=\"2320\"\u003eA defective module may cause:\u003c\/p\u003e\n\u003cul data-start=\"2322\" data-end=\"2567\"\u003e\n\u003cli data-start=\"2322\" data-end=\"2362\"\u003eDisplay completely off or unreadable\u003c\/li\u003e\n\u003cli data-start=\"2363\" data-end=\"2389\"\u003eWhite or frozen screen\u003c\/li\u003e\n\u003cli data-start=\"2390\" data-end=\"2429\"\u003eLoss of communication with inverter\u003c\/li\u003e\n\u003cli data-start=\"2430\" data-end=\"2466\"\u003eNon-functioning buttons or menus\u003c\/li\u003e\n\u003cli data-start=\"2467\" data-end=\"2500\"\u003eStartup freeze or boot issues\u003c\/li\u003e\n\u003cli data-start=\"2501\" data-end=\"2539\"\u003eLAN\/Ethernet communication failure\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2567\"\u003eFirmware or boot errors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2569\" data-end=\"2572\"\u003e\n\u003ch3 data-start=\"2574\" data-end=\"2610\"\u003e🚨 Common Error Codes Associated\u003c\/h3\u003e\n\u003cp data-start=\"2612\" data-end=\"2659\"\u003ePossible faults related to this module include:\u003c\/p\u003e\n\u003cul data-start=\"2661\" data-end=\"2855\"\u003e\n\u003cli data-start=\"2661\" data-end=\"2684\"\u003eCommunication Error\u003c\/li\u003e\n\u003cli data-start=\"2685\" data-end=\"2707\"\u003eDisplay Init Error\u003c\/li\u003e\n\u003cli data-start=\"2708\" data-end=\"2731\"\u003eControl Panel Fault\u003c\/li\u003e\n\u003cli data-start=\"2732\" data-end=\"2754\"\u003eInternal Bus Error\u003c\/li\u003e\n\u003cli data-start=\"2755\" data-end=\"2773\"\u003eFirmware Error\u003c\/li\u003e\n\u003cli data-start=\"2774\" data-end=\"2801\"\u003eHMI Communication Fault\u003c\/li\u003e\n\u003cli data-start=\"2802\" data-end=\"2827\"\u003eEEPROM \/ Memory Error\u003c\/li\u003e\n\u003cli data-start=\"2828\" data-end=\"2855\"\u003eLAN Communication Error\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2857\" data-end=\"2921\"\u003e\u003cem data-start=\"2857\" data-end=\"2921\"\u003e(Error naming may vary depending on Sunways firmware version.)\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"2923\" data-end=\"2926\"\u003e\n\u003ch3 data-start=\"2928\" data-end=\"2957\"\u003e📋 Product Specifications\u003c\/h3\u003e\n\u003cul data-start=\"2959\" data-end=\"3238\"\u003e\n\u003cli data-start=\"2959\" data-end=\"2991\"\u003e\n\u003cstrong data-start=\"2961\" data-end=\"2978\"\u003eManufacturer:\u003c\/strong\u003e Sunways AG\u003c\/li\u003e\n\u003cli data-start=\"2992\" data-end=\"3029\"\u003e\n\u003cstrong data-start=\"2994\" data-end=\"3012\"\u003eCompatibility:\u003c\/strong\u003e Sunways AT3600\u003c\/li\u003e\n\u003cli data-start=\"3030\" data-end=\"3084\"\u003e\n\u003cstrong data-start=\"3032\" data-end=\"3048\"\u003eModule Type:\u003c\/strong\u003e LCD Display \u0026amp; Communication Board\u003c\/li\u003e\n\u003cli data-start=\"3085\" data-end=\"3135\"\u003e\n\u003cstrong data-start=\"3087\" data-end=\"3110\"\u003eDisplay Technology:\u003c\/strong\u003e Monochrome graphic LCD\u003c\/li\u003e\n\u003cli data-start=\"3136\" data-end=\"3186\"\u003e\n\u003cstrong data-start=\"3138\" data-end=\"3156\"\u003eCommunication:\u003c\/strong\u003e LAN \/ internal inverter bus\u003c\/li\u003e\n\u003cli data-start=\"3187\" data-end=\"3238\"\u003e\n\u003cstrong data-start=\"3189\" data-end=\"3205\"\u003eApplication:\u003c\/strong\u003e Grid-tie photovoltaic inverter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3240\" data-end=\"3243\"\u003e\n\u003ch3 data-start=\"3245\" data-end=\"3259\"\u003e📌 Summary\u003c\/h3\u003e\n\u003cp data-start=\"3261\" data-end=\"3383\"\u003eThe \u003cstrong data-start=\"3265\" data-end=\"3317\"\u003eSunways AT3600 LCD Display \u0026amp; Communication Board\u003c\/strong\u003e is the inverter’s central user interface module, responsible for:\u003c\/p\u003e\n\u003cp data-start=\"3385\" data-end=\"3601\"\u003e✔ Displaying operational and production data\u003cbr data-start=\"3429\" data-end=\"3432\"\u003e✔ Managing inverter configuration and diagnostics\u003cbr data-start=\"3481\" data-end=\"3484\"\u003e✔ Handling communication with internal inverter electronics\u003cbr data-start=\"3543\" data-end=\"3546\"\u003e✔ Providing local and remote monitoring functionality\u003c\/p\u003e\n\u003cp data-start=\"3603\" data-end=\"3728\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e👉 An essential component for proper inverter supervision, diagnostics, and user interaction in Sunways photovoltaic systems.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53854265966925,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5623.jpg?v=1778081074","url":"https:\/\/greenenergy-repair.com\/products\/sunways-at3600-lcd-display-communication-board-hmi-interface-module-for-photovoltaic-inverter","provider":"Green Energy","version":"1.0","type":"link"}