{"product_id":"siemens-3nw7033-3p-fuse-holder-for-10-38-mm-fuses-32a-up-to-690v-ac-din-rail-mount","title":"Siemens 3NW7033 – 3P Fuse Holder for 10×38 mm Fuses | 32A | up to 690V AC | DIN Rail Mount","description":"\u003cp data-start=\"169\" data-end=\"438\"\u003eThe \u003cstrong data-start=\"173\" data-end=\"192\"\u003eSiemens 3NW7033\u003c\/strong\u003e is a \u003cstrong data-start=\"198\" data-end=\"243\"\u003ethree-phase modular fuse holder (3 poles)\u003c\/strong\u003e designed to accommodate \u003cstrong data-start=\"268\" data-end=\"303\"\u003e10×38 mm cylindrical fuse links\u003c\/strong\u003e, commonly used for protecting electrical lines and equipment in industrial installations, distribution boards, and automation systems.\u003c\/p\u003e\n\u003cp data-start=\"440\" data-end=\"620\"\u003eThis device allows the installation of \u003cstrong data-start=\"479\" data-end=\"511\"\u003ethree independent fuse links\u003c\/strong\u003e, providing compact and reliable protection for three-phase circuits against overcurrents and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"622\" data-end=\"795\"\u003eThanks to Siemens’ modular construction and compatibility with \u003cstrong data-start=\"685\" data-end=\"715\"\u003estandard DIN rail mounting\u003c\/strong\u003e, the fuse holder ensures fast and secure installation inside electrical panels.\u003c\/p\u003e\n\u003chr data-start=\"797\" data-end=\"800\"\u003e\n\u003ch2 data-start=\"802\" data-end=\"834\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"836\" data-end=\"1147\"\u003e\u003cstrong data-start=\"836\" data-end=\"846\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"854\" data-end=\"857\"\u003e\u003cstrong data-start=\"857\" data-end=\"867\"\u003eModel:\u003c\/strong\u003e 3NW7033\u003cbr data-start=\"875\" data-end=\"878\"\u003e\u003cstrong data-start=\"878\" data-end=\"887\"\u003eType:\u003c\/strong\u003e Modular fuse holder\u003cbr data-start=\"907\" data-end=\"910\"\u003e\u003cstrong data-start=\"910\" data-end=\"930\"\u003eNumber of poles:\u003c\/strong\u003e 3P (three-phase)\u003cbr data-start=\"947\" data-end=\"950\"\u003e\u003cstrong data-start=\"950\" data-end=\"975\"\u003eCompatible fuse type:\u003c\/strong\u003e Cylindrical \u003cstrong data-start=\"988\" data-end=\"1002\"\u003e10 × 38 mm\u003c\/strong\u003e\u003cbr data-start=\"1002\" data-end=\"1005\"\u003e\u003cstrong data-start=\"1005\" data-end=\"1023\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1024\" data-end=\"1032\"\u003e32 A\u003c\/strong\u003e\u003cbr data-start=\"1032\" data-end=\"1035\"\u003e\u003cstrong data-start=\"1035\" data-end=\"1053\"\u003eRated voltage:\u003c\/strong\u003e up to \u003cstrong data-start=\"1060\" data-end=\"1072\"\u003e690 V AC\u003c\/strong\u003e\u003cbr data-start=\"1072\" data-end=\"1075\"\u003e\u003cstrong data-start=\"1075\" data-end=\"1097\"\u003ePower dissipation:\u003c\/strong\u003e approx. \u003cstrong data-start=\"1106\" data-end=\"1113\"\u003e3 W\u003c\/strong\u003e\u003cbr data-start=\"1113\" data-end=\"1116\"\u003e\u003cstrong data-start=\"1116\" data-end=\"1129\"\u003eStandard:\u003c\/strong\u003e \u003cstrong data-start=\"1130\" data-end=\"1145\"\u003eIEC 60947-3\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1149\" data-end=\"1186\"\u003e🔌 Electrical \u0026amp; Mechanical Data\u003c\/h3\u003e\n\u003cul data-start=\"1188\" data-end=\"1311\"\u003e\n\u003cli data-start=\"1188\" data-end=\"1229\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1229\"\u003eCable cross-section: \u003cstrong data-start=\"1211\" data-end=\"1227\"\u003e0.5 – 10 mm²\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1280\"\u003e\n\u003cp data-start=\"1232\" data-end=\"1280\"\u003eTerminal tightening torque: approx. \u003cstrong data-start=\"1268\" data-end=\"1278\"\u003e1.2 Nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1281\" data-end=\"1311\"\u003e\n\u003cp data-start=\"1283\" data-end=\"1311\"\u003eMounting: \u003cstrong data-start=\"1293\" data-end=\"1311\"\u003eDIN rail 35 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1313\" data-end=\"1316\"\u003e\n\u003ch2 data-start=\"1318\" data-end=\"1337\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003cp data-start=\"1339\" data-end=\"1388\"\u003eThe device includes \u003cstrong data-start=\"1359\" data-end=\"1387\"\u003esix connection terminals\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp data-start=\"1390\" data-end=\"1407\"\u003e\u003cstrong data-start=\"1390\" data-end=\"1405\"\u003eLine input:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1408\" data-end=\"1425\"\u003e\n\u003cli data-start=\"1408\" data-end=\"1413\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1413\"\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1414\" data-end=\"1419\"\u003e\n\u003cp data-start=\"1416\" data-end=\"1419\"\u003e3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1425\"\u003e\n\u003cp data-start=\"1422\" data-end=\"1425\"\u003e5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1427\" data-end=\"1445\"\u003e\u003cstrong data-start=\"1427\" data-end=\"1443\"\u003eLoad output:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1446\" data-end=\"1463\"\u003e\n\u003cli data-start=\"1446\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1448\" data-end=\"1451\"\u003e2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1457\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1457\"\u003e4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1458\" data-end=\"1463\"\u003e\n\u003cp data-start=\"1460\" data-end=\"1463\"\u003e6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1465\" data-end=\"1526\"\u003eTypical configuration for \u003cstrong data-start=\"1491\" data-end=\"1525\"\u003ethree-phase protection systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1528\" data-end=\"1531\"\u003e\n\u003ch2 data-start=\"1533\" data-end=\"1562\"\u003e🛡 Construction Features\u003c\/h2\u003e\n\u003cp data-start=\"1564\" data-end=\"1761\"\u003e✔ Compact Siemens modular design\u003cbr data-start=\"1596\" data-end=\"1599\"\u003e✔ Housing for \u003cstrong data-start=\"1613\" data-end=\"1650\"\u003e3 cylindrical fuse links 10×38 mm\u003c\/strong\u003e\u003cbr data-start=\"1650\" data-end=\"1653\"\u003e✔ Robust screw terminals\u003cbr data-start=\"1677\" data-end=\"1680\"\u003e✔ High reliability for industrial applications\u003cbr data-start=\"1726\" data-end=\"1729\"\u003e✔ Simple DIN rail installation\u003c\/p\u003e\n\u003cp data-start=\"1763\" data-end=\"1837\"\u003e⚠ Safety marking present on the device:\u003cbr data-start=\"1802\" data-end=\"1805\"\u003e\u003cstrong data-start=\"1805\" data-end=\"1837\"\u003e“Do not operate under load.”\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1839\" data-end=\"1842\"\u003e\n\u003ch2 data-start=\"1844\" data-end=\"1864\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1866\" data-end=\"1906\"\u003eThe Siemens fuse holder is suitable for:\u003c\/p\u003e\n\u003cp data-start=\"1908\" data-end=\"2117\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1938\" data-end=\"1941\"\u003e✔ Three-phase line protection\u003cbr data-start=\"1970\" data-end=\"1973\"\u003e✔ Industrial automation systems\u003cbr data-start=\"2004\" data-end=\"2007\"\u003e✔ Photovoltaic installations\u003cbr data-start=\"2035\" data-end=\"2038\"\u003e✔ Power distribution boards\u003cbr data-start=\"2065\" data-end=\"2068\"\u003e✔ Protection of motors and electrical equipment\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53473921794381,"sku":null,"price":8.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5043.jpg?v=1772624198","url":"https:\/\/greenenergy-repair.com\/products\/siemens-3nw7033-3p-fuse-holder-for-10-38-mm-fuses-32a-up-to-690v-ac-din-rail-mount","provider":"Green Energy","version":"1.0","type":"link"}