{"product_id":"schneider-electric-lc1d32-3p-32a-ac-3-contactor-690v-ac-coil-a1-a2-tesys-d-series","title":"Schneider Electric LC1D32 – 3P 32A AC-3 Contactor | 690V AC | Coil A1\/A2 | TeSys D Series","description":"\u003cp data-start=\"184\" data-end=\"432\"\u003eThe \u003cstrong data-start=\"188\" data-end=\"217\"\u003eSchneider Electric LC1D32\u003c\/strong\u003e is a three-phase electromechanical power contactor from the \u003cstrong data-start=\"278\" data-end=\"296\"\u003eTeSys D series\u003c\/strong\u003e (formerly Telemecanique), designed for switching and controlling electric motors and industrial loads in \u003cstrong data-start=\"402\" data-end=\"431\"\u003eAC-3 utilization category\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"434\" data-end=\"644\"\u003eCompact, robust, and highly reliable, this contactor is suitable for industrial automation panels and power distribution systems, offering high switching performance and long mechanical and electrical lifespan.\u003c\/p\u003e\n\u003chr data-start=\"646\" data-end=\"649\"\u003e\n\u003ch2 data-start=\"651\" data-end=\"683\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"685\" data-end=\"826\"\u003e\u003cstrong data-start=\"685\" data-end=\"695\"\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003cbr data-start=\"714\" data-end=\"717\"\u003e\u003cstrong data-start=\"717\" data-end=\"728\"\u003eSeries:\u003c\/strong\u003e TeSys D\u003cbr data-start=\"736\" data-end=\"739\"\u003e\u003cstrong data-start=\"739\" data-end=\"749\"\u003eModel:\u003c\/strong\u003e LC1D32\u003cbr data-start=\"756\" data-end=\"759\"\u003e\u003cstrong data-start=\"759\" data-end=\"768\"\u003eType:\u003c\/strong\u003e Power contactor\u003cbr data-start=\"784\" data-end=\"787\"\u003e\u003cstrong data-start=\"787\" data-end=\"807\"\u003eNumber of poles:\u003c\/strong\u003e 3P (three-phase)\u003c\/p\u003e\n\u003ch3 data-start=\"828\" data-end=\"855\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"857\" data-end=\"1085\"\u003e\n\u003cli data-start=\"857\" data-end=\"903\"\u003e\n\u003cp data-start=\"859\" data-end=\"903\"\u003eRated operational current (AC-3): \u003cstrong data-start=\"893\" data-end=\"901\"\u003e32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"958\"\u003e\n\u003cp data-start=\"906\" data-end=\"958\"\u003eRated operational voltage (Ue): \u003cstrong data-start=\"938\" data-end=\"956\"\u003eup to 690 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"959\" data-end=\"1003\"\u003e\n\u003cp data-start=\"961\" data-end=\"1003\"\u003eRated insulation voltage (Ui): \u003cstrong data-start=\"992\" data-end=\"1001\"\u003e690 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1004\" data-end=\"1050\"\u003e\n\u003cp data-start=\"1006\" data-end=\"1050\"\u003eImpulse withstand voltage (Uimp): \u003cstrong data-start=\"1040\" data-end=\"1048\"\u003e6 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1051\" data-end=\"1085\"\u003e\n\u003cp data-start=\"1053\" data-end=\"1085\"\u003eUtilization category: \u003cstrong data-start=\"1075\" data-end=\"1083\"\u003eAC-3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1087\" data-end=\"1124\"\u003e⚡ Indicative Motor Power (AC-3)\u003c\/h3\u003e\n\u003cul data-start=\"1126\" data-end=\"1194\"\u003e\n\u003cli data-start=\"1126\" data-end=\"1148\"\u003e\n\u003cp data-start=\"1128\" data-end=\"1148\"\u003e\u003cstrong data-start=\"1128\" data-end=\"1146\"\u003e7.5 kW @ 230 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1170\"\u003e\n\u003cp data-start=\"1151\" data-end=\"1170\"\u003e\u003cstrong data-start=\"1151\" data-end=\"1168\"\u003e15 kW @ 400 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1171\" data-end=\"1194\"\u003e\n\u003cp data-start=\"1173\" data-end=\"1194\"\u003e\u003cstrong data-start=\"1173\" data-end=\"1192\"\u003e18.5 kW @ 500 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1196\" data-end=\"1220\"\u003e🔄 Control Circuit\u003c\/h3\u003e\n\u003cul data-start=\"1222\" data-end=\"1313\"\u003e\n\u003cli data-start=\"1222\" data-end=\"1253\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1253\"\u003eCoil terminals: \u003cstrong data-start=\"1240\" data-end=\"1251\"\u003eA1 – A2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1313\"\u003e\n\u003cp data-start=\"1256\" data-end=\"1313\"\u003e⚠ Coil voltage must be verified on the device nameplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1315\" data-end=\"1355\"\u003e🔧 Auxiliary Contacts (Integrated)\u003c\/h3\u003e\n\u003cul data-start=\"1357\" data-end=\"1398\"\u003e\n\u003cli data-start=\"1357\" data-end=\"1377\"\u003e\n\u003cp data-start=\"1359\" data-end=\"1377\"\u003e\u003cstrong data-start=\"1359\" data-end=\"1375\"\u003e1 NO (13-14)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1398\"\u003e\n\u003cp data-start=\"1380\" data-end=\"1398\"\u003e\u003cstrong data-start=\"1380\" data-end=\"1396\"\u003e1 NC (21-22)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1400\" data-end=\"1418\"\u003e📜 Standards\u003c\/h3\u003e\n\u003cul data-start=\"1420\" data-end=\"1442\"\u003e\n\u003cli data-start=\"1420\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1422\" data-end=\"1442\"\u003eIEC \/ EN 60947-4-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1444\" data-end=\"1461\"\u003e🛠 Mounting\u003c\/h3\u003e\n\u003cul data-start=\"1463\" data-end=\"1515\"\u003e\n\u003cli data-start=\"1463\" data-end=\"1484\"\u003e\n\u003cp data-start=\"1465\" data-end=\"1484\"\u003eDIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1485\" data-end=\"1515\"\u003e\n\u003cp data-start=\"1487\" data-end=\"1515\"\u003ePanel mounting with screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1517\" data-end=\"1520\"\u003e\n\u003ch2 data-start=\"1522\" data-end=\"1538\"\u003e🔎 Function\u003c\/h2\u003e\n\u003cp data-start=\"1540\" data-end=\"1570\"\u003eThe contactor is designed for:\u003c\/p\u003e\n\u003cp data-start=\"1572\" data-end=\"1734\"\u003e✔ Starting and stopping three-phase motors\u003cbr data-start=\"1614\" data-end=\"1617\"\u003e✔ Switching inductive loads\u003cbr data-start=\"1644\" data-end=\"1647\"\u003e✔ Integration into industrial automation systems\u003cbr data-start=\"1695\" data-end=\"1698\"\u003e✔ Use in power distribution panels\u003c\/p\u003e\n\u003cp data-start=\"1736\" data-end=\"1824\"\u003eIntegrated auxiliary contacts allow signaling, control logic, or interlocking functions.\u003c\/p\u003e\n\u003chr data-start=\"1826\" data-end=\"1829\"\u003e\n\u003ch2 data-start=\"1831\" data-end=\"1851\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1853\" data-end=\"1999\"\u003e✔ Industrial automation panels\u003cbr data-start=\"1883\" data-end=\"1886\"\u003e✔ Three-phase motor control\u003cbr data-start=\"1913\" data-end=\"1916\"\u003e✔ Compressors\u003cbr data-start=\"1929\" data-end=\"1932\"\u003e✔ Pumps\u003cbr data-start=\"1939\" data-end=\"1942\"\u003e✔ Industrial fans\u003cbr data-start=\"1959\" data-end=\"1962\"\u003e✔ HVAC systems\u003cbr data-start=\"1976\" data-end=\"1979\"\u003e✔ Production lines\u003c\/p\u003e\n\u003chr data-start=\"2001\" data-end=\"2004\"\u003e\n\u003ch2 data-start=\"2006\" data-end=\"2026\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2028\" data-end=\"2189\"\u003e\n\u003cli data-start=\"2028\" data-end=\"2061\"\u003e\n\u003cp data-start=\"2030\" data-end=\"2061\"\u003eMounting on DIN rail or panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2062\" data-end=\"2108\"\u003e\n\u003cp data-start=\"2064\" data-end=\"2108\"\u003ePower connections: \u003cstrong data-start=\"2083\" data-end=\"2106\"\u003eL1-L2-L3 \/ T1-T2-T3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2109\" data-end=\"2139\"\u003e\n\u003cp data-start=\"2111\" data-end=\"2139\"\u003eCoil connection: \u003cstrong data-start=\"2128\" data-end=\"2137\"\u003eA1-A2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2140\" data-end=\"2189\"\u003e\n\u003cp data-start=\"2142\" data-end=\"2189\"\u003eCompatible with TeSys thermal overload relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2191\" data-end=\"2194\"\u003e\n\u003ch2 data-start=\"2196\" data-end=\"2213\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2215\" data-end=\"2326\"\u003eUsed product in good cosmetic condition.\u003cbr data-start=\"2255\" data-end=\"2258\"\u003eVerification of coil voltage is recommended prior to installation.\u003c\/p\u003e\n\u003chr data-start=\"2328\" data-end=\"2331\"\u003e\n\u003ch2 data-start=\"2333\" data-end=\"2356\"\u003e📦 Scope of Supply\u003c\/h2\u003e\n\u003cul data-start=\"2358\" data-end=\"2400\"\u003e\n\u003cli data-start=\"2358\" data-end=\"2400\"\u003e\n\u003cp data-start=\"2360\" data-end=\"2400\"\u003e1x Schneider Electric LC1D32 contactor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2402\" data-end=\"2405\"\u003e\n\u003ch2 data-start=\"2407\" data-end=\"2433\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2435\" data-end=\"2673\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eProfessional 32A AC-3 three-phase contactor from the Schneider Electric TeSys D range. The LC1D32 is ideal for controlling motors up to 15 kW at 400V, offering reliable performance for industrial automation and power control applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53459797311821,"sku":null,"price":45.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5056.jpg?v=1772533386","url":"https:\/\/greenenergy-repair.com\/products\/schneider-electric-lc1d32-3p-32a-ac-3-contactor-690v-ac-coil-a1-a2-tesys-d-series","provider":"Green Energy","version":"1.0","type":"link"}