{"product_id":"phoenix-contact-val-ms-1000dc-type-2-dc-spd-1000-v-dc-30-ka-valvetrab-series-din-rail-surge-protection","title":"Phoenix Contact VAL-MS 1000DC | Type 2 DC SPD | 1000 V DC | 30 kA | VALVETRAB Series | DIN Rail Surge Protection","description":"\u003ch2 data-start=\"135\" data-end=\"154\"\u003e\u003cstrong data-start=\"138\" data-end=\"154\"\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"156\" data-end=\"398\"\u003eThe \u003cstrong data-start=\"160\" data-end=\"193\"\u003ePhoenix Contact VAL-MS 1000DC\u003c\/strong\u003e from the \u003cstrong data-start=\"203\" data-end=\"223\"\u003eVALVETRAB series\u003c\/strong\u003e is a modular \u003cstrong data-start=\"237\" data-end=\"277\"\u003eType 2 Surge Protective Device (SPD)\u003c\/strong\u003e designed for \u003cstrong data-start=\"291\" data-end=\"323\"\u003eDC applications up to 1000 V\u003c\/strong\u003e, making it ideal for photovoltaic systems and industrial DC installations.\u003c\/p\u003e\n\u003cp data-start=\"400\" data-end=\"687\"\u003eManufactured by \u003cstrong data-start=\"416\" data-end=\"457\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003ePhoenix Contact\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e, this surge arrester provides reliable protection for inverters, PV strings, and sensitive electronic components against transient overvoltages caused by indirect lightning strikes, atmospheric disturbances, and switching events.\u003c\/p\u003e\n\u003cp data-start=\"689\" data-end=\"982\"\u003eConfigured in \u003cstrong data-start=\"703\" data-end=\"728\"\u003eL+ \/ PE \/ L− topology\u003c\/strong\u003e, it ensures full pole protection for DC systems. The device features \u003cstrong data-start=\"798\" data-end=\"840\"\u003eplug-in replaceable protection modules\u003c\/strong\u003e with integrated visual status indicators and is designed for quick installation on a \u003cstrong data-start=\"926\" data-end=\"938\"\u003eDIN rail\u003c\/strong\u003e inside electrical panels or combiner boxes.\u003c\/p\u003e\n\u003cp data-start=\"984\" data-end=\"1028\"\u003e🛠 \u003cstrong data-start=\"987\" data-end=\"1000\"\u003eWarranty:\u003c\/strong\u003e 12 months by Green Energy\u003c\/p\u003e\n\u003chr data-start=\"1030\" data-end=\"1033\"\u003e\n\u003ch2 data-start=\"1035\" data-end=\"1059\"\u003e⚙️ Technical Details:\u003c\/h2\u003e\n\u003cp data-start=\"1061\" data-end=\"1299\"\u003e\u003cstrong data-start=\"1061\" data-end=\"1071\"\u003eBrand:\u003c\/strong\u003e Phoenix Contact\u003cbr data-start=\"1087\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1090\" data-end=\"1101\"\u003eSeries:\u003c\/strong\u003e VALVETRAB\u003cbr data-start=\"1111\" data-end=\"1114\"\u003e\u003cstrong data-start=\"1114\" data-end=\"1129\"\u003eBase Model:\u003c\/strong\u003e VAL-MS 1000DC\u003cbr data-start=\"1143\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1159\"\u003eSPD Type:\u003c\/strong\u003e Type 2 (T2)\u003cbr data-start=\"1171\" data-end=\"1174\"\u003e\u003cstrong data-start=\"1174\" data-end=\"1210\"\u003eMaximum Continuous Voltage (Uc):\u003c\/strong\u003e 1000 V DC\u003cbr data-start=\"1220\" data-end=\"1223\"\u003e\u003cstrong data-start=\"1223\" data-end=\"1241\"\u003eConfiguration:\u003c\/strong\u003e L+ \/ PE \/ L−\u003cbr data-start=\"1254\" data-end=\"1257\"\u003e\u003cstrong data-start=\"1257\" data-end=\"1270\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003cbr data-start=\"1279\" data-end=\"1282\"\u003e\u003cstrong data-start=\"1282\" data-end=\"1294\"\u003eMarking:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003cp data-start=\"1301\" data-end=\"1334\"\u003e\u003cstrong data-start=\"1301\" data-end=\"1334\"\u003eInstalled Protection Modules:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1336\" data-end=\"1570\"\u003e\n\u003cli data-start=\"1336\" data-end=\"1412\"\u003e\n\u003cp data-start=\"1338\" data-end=\"1361\"\u003e\u003cstrong data-start=\"1338\" data-end=\"1359\"\u003eVAL-MS 1000 PV ST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1364\" data-end=\"1412\"\u003e\n\u003cli data-start=\"1364\" data-end=\"1378\"\u003e\n\u003cp data-start=\"1366\" data-end=\"1378\"\u003eUp: 2.5 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1394\"\u003e\n\u003cp data-start=\"1383\" data-end=\"1394\"\u003eIn: 15 kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1397\" data-end=\"1412\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1412\"\u003eImax: 30 kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1414\" data-end=\"1492\"\u003e\n\u003cp data-start=\"1416\" data-end=\"1439\"\u003e\u003cstrong data-start=\"1416\" data-end=\"1437\"\u003eVAL-MS 1100\/30 ST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1442\" data-end=\"1492\"\u003e\n\u003cli data-start=\"1442\" data-end=\"1458\"\u003e\n\u003cp data-start=\"1444\" data-end=\"1458\"\u003eUp: \u0026lt; 1.1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1461\" data-end=\"1474\"\u003e\n\u003cp data-start=\"1463\" data-end=\"1474\"\u003eIn: 20 kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1492\"\u003e\n\u003cp data-start=\"1479\" data-end=\"1492\"\u003eImax: 30 kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1494\" data-end=\"1570\"\u003e\n\u003cp data-start=\"1496\" data-end=\"1519\"\u003e\u003cstrong data-start=\"1496\" data-end=\"1517\"\u003eVAL-MS 1000 PV ST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1522\" data-end=\"1570\"\u003e\n\u003cli data-start=\"1522\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1524\" data-end=\"1536\"\u003eUp: 2.5 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1539\" data-end=\"1552\"\u003e\n\u003cp data-start=\"1541\" data-end=\"1552\"\u003eIn: 15 kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1555\" data-end=\"1570\"\u003e\n\u003cp data-start=\"1557\" data-end=\"1570\"\u003eImax: 30 kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1572\" data-end=\"1575\"\u003e\n\u003ch2 data-start=\"1577\" data-end=\"1597\"\u003e📌 Key Functions:\u003c\/h2\u003e\n\u003cp data-start=\"1599\" data-end=\"1904\"\u003e✔️ Surge protection for photovoltaic DC systems\u003cbr data-start=\"1646\" data-end=\"1649\"\u003e✔️ Rated for operation up to 1000 V DC\u003cbr data-start=\"1687\" data-end=\"1690\"\u003e✔️ Discharge capacity up to 30 kA\u003cbr data-start=\"1723\" data-end=\"1726\"\u003e✔️ Replaceable plug-in protection modules\u003cbr data-start=\"1767\" data-end=\"1770\"\u003e✔️ Visual status indicator for maintenance\u003cbr data-start=\"1812\" data-end=\"1815\"\u003e✔️ Full pole protection configuration\u003cbr data-start=\"1852\" data-end=\"1855\"\u003e✔️ Industrial-grade Phoenix Contact reliability\u003c\/p\u003e\n\u003chr data-start=\"1906\" data-end=\"1909\"\u003e\n\u003ch2 data-start=\"1911\" data-end=\"1930\"\u003e🛠 Applications:\u003c\/h2\u003e\n\u003cp data-start=\"1932\" data-end=\"2092\"\u003e✔️ Photovoltaic installations\u003cbr data-start=\"1961\" data-end=\"1964\"\u003e✔️ Solar string combiner boxes\u003cbr data-start=\"1994\" data-end=\"1997\"\u003e✔️ DC-side inverter protection\u003cbr data-start=\"2027\" data-end=\"2030\"\u003e✔️ Renewable energy systems\u003cbr data-start=\"2057\" data-end=\"2060\"\u003e✔️ Industrial DC installations\u003c\/p\u003e\n\u003chr data-start=\"2094\" data-end=\"2097\"\u003e\n\u003ch2 data-start=\"2099\" data-end=\"2124\"\u003e⚡ Operating Principle:\u003c\/h2\u003e\n\u003cp data-start=\"2126\" data-end=\"2162\"\u003eWhen a transient overvoltage occurs:\u003c\/p\u003e\n\u003cul data-start=\"2164\" data-end=\"2349\"\u003e\n\u003cli data-start=\"2164\" data-end=\"2205\"\u003e\n\u003cp data-start=\"2166\" data-end=\"2205\"\u003eThe SPD intercepts the voltage spike.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2206\" data-end=\"2257\"\u003e\n\u003cp data-start=\"2208\" data-end=\"2257\"\u003eExcess energy is safely diverted to earth (PE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2258\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2260\" data-end=\"2305\"\u003eResidual voltage is limited to safe levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2306\" data-end=\"2349\"\u003e\n\u003cp data-start=\"2308\" data-end=\"2349\"\u003eDownstream equipment remains protected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2351\" data-end=\"2354\"\u003e\n\u003cp data-start=\"2356\" data-end=\"2505\"\u003e🚀 \u003cstrong data-start=\"2359\" data-end=\"2505\"\u003eProfessional surge protection for 1000 V DC systems — reliable industrial technology by Phoenix Contact, tested and supported by Green Energy.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53348607885645,"sku":null,"price":65.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4820.jpg?v=1770915028","url":"https:\/\/greenenergy-repair.com\/products\/phoenix-contact-val-ms-1000dc-type-2-dc-spd-1000-v-dc-30-ka-valvetrab-series-din-rail-surge-protection","provider":"Green Energy","version":"1.0","type":"link"}