{"product_id":"dcei-601-40x60-insulators-m10-busbar-supports-electrical-panels","title":"DCEI-601 40x60 Insulators | M10 Busbar Supports | Electrical Panels","description":"\u003ch3\u003e \u003cspan\u003e📝 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eUsed product.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003ePack of\u003c\/strong\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 DCEI-601 cylindrical electrical busbar insulators\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, identifiable by the marking stamped on the body and the dimensional designation \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40x60\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, both visible in the photographs.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThese are column-type insulating supports with a smooth, brown cylindrical body and female threaded metal inserts. They are designed to support and space conductive busbars inside electrical panels and power distribution systems.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe cylindrical structure provides a regular supporting surface and good mechanical strength. The metal inserts allow fastening with compatible screws or threaded studs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚙️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eType:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Cylindrical electrical busbar insulator\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIdentification code:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e DCEI-601\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensional marking:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 40x60\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eColour:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Brown\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody profile:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Smooth cylindrical\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStructure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Column-type insulator\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInserts:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Female threaded metal inserts\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInsert material:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e White zinc-plated steel, according to the information provided\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eThread:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e M10\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInsulating material:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e BMC thermosetting polyester resin reinforced with glass fibre, according to the specifications provided\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDeclared manufacturing process:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compression moulding\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e📏 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDimensional Table\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIdentification code\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCEI-601\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensional marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40x60\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOverall height (H)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBody diameter (Ø)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBody profile\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSmooth cylindrical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInsert thread\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eUsable thread depth (T)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.35 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚡ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDeclared Electrical Specifications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe following values are stated in the technical specifications provided for this model. As no official datasheet has been identified with certainty as belonging to the DCEI-601, these should be considered declared but unverified specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated operating voltage (Ue):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 1000 V AC \/ 1500 V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated power-frequency withstand voltage (50 Hz \/ 1 min):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12 kV AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated impulse withstand voltage (Uimp):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12 kV\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDielectric strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026gt; 10 kV\/mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInsulating properties:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High dielectric characteristics, according to the specifications provided\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔩 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMechanical and Thermal Specifications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDeclared compressive strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 75–80 kN\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMaterial:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e BMC thermosetting polyester resin reinforced with glass fibre\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eManufacturing process:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compression moulding\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFire behaviour:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Self-extinguishing, UL94 V-0 rating, according to the information provided\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHalogen-free:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e According to the declared specifications\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMechanical strength is an important characteristic of busbar insulators, as these components must support conductive busbars and help secure them inside electrical panels.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔧 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMain Functions\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eElectrical insulation between conductive busbars and the supporting structure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupporting copper or aluminium busbars.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintaining clearance between electrically live parts.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMechanical fastening of busbars using threaded inserts.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupporting power distribution structures.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProviding resistance to mechanical stress, according to the declared material properties.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏭 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003ePower distribution panels.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial distribution switchboards.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomation control panels.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical substations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBusbar distribution and support systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial electrical installations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement parts for electrical equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e⭐ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eCompact and robust cylindrical body.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e60 mm height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for busbar spacing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e40 mm body diameter.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eM10 threaded metal inserts.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGlass-fibre-reinforced insulating material, according to the specifications provided.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesign suitable for supporting and securing conductive busbars.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDCEI-601 identification marking\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e present on the component.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e📦 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eProduct Condition\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUsed product, sourced from reclaimed materials or warehouse stock.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe insulators show normal surface signs of storage and handling, as visible in the photographs. The threaded metal inserts are present and visible.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNo electrical, mechanical or insulation tests have been carried out; operation and performance have not been verified.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe electrical, mechanical and thermal specifications stated are based on the information provided and do not constitute certification of the product shown in the photographs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e📋 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSale Includes\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e10 DCEI-601 40x60 cylindrical busbar insulators.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAll pieces are the same model and have the dimensional specifications stated above.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe photographs show some examples for illustrative purposes.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSummary\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003ePack of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 used DCEI-601 40x60 cylindrical electrical busbar insulators\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, featuring brown insulating bodies, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60 mm height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40 mm diameter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eM10 female threaded metal inserts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for supporting and spacing conductive busbars inside power distribution panels, industrial switchboards and electrical power distribution systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"DCEI","offers":[{"title":"Default Title","offer_id":55260115796301,"sku":null,"price":25.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7357.jpg?v=1793639506","url":"https:\/\/greenenergy-repair.com\/products\/dcei-601-40x60-insulators-m10-busbar-supports-electrical-panels","provider":"Green Energy","version":"1.0","type":"link"}