{"product_id":"abb-sace-s3n-250-4p-250-a-690-v-ac-mccb","title":"ABB SACE S3N 250 4P | 250 A | 690 V AC | MCCB","description":"\u003ch3 dir=\"auto\" data-start=\"52\" data-end=\"74\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"59\" data-end=\"74\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"75\" data-end=\"671\"\u003e\u003cstrong data-start=\"75\" data-end=\"91\"\u003eUsed product\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong data-start=\"96\" data-end=\"123\"\u003eABB SACE Isomax S3N 250\u003c\/strong\u003e is a molded-case circuit breaker for electrical distribution and protection applications in industrial systems and low-voltage switchboards.\u003cbr\u003eThe device belongs to the \u003cstrong data-start=\"291\" data-end=\"313\"\u003eABB SACE Isomax S3\u003c\/strong\u003e family and is designed to protect circuits against \u003cstrong data-start=\"365\" data-end=\"397\"\u003eoverloads and short circuits\u003c\/strong\u003e. The version shown in the photographs is configured with \u003cstrong data-start=\"455\" data-end=\"466\"\u003e4 poles\u003c\/strong\u003e, a rated uninterrupted current of \u003cstrong data-start=\"501\" data-end=\"510\"\u003e250 A\u003c\/strong\u003e, and an operating voltage of up to \u003cstrong data-start=\"546\" data-end=\"558\"\u003e690 V AC\u003c\/strong\u003e. The nameplate also indicates compliance with \u003cstrong data-start=\"605\" data-end=\"620\"\u003eIEC 60947-2\u003c\/strong\u003e and an impulse withstand voltage \u003cstrong data-start=\"654\" data-end=\"670\"\u003eUimp of 8 kV\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"672\" data-end=\"702\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"679\" data-end=\"702\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"703\" data-end=\"1652\"\u003e\n\u003cli data-start=\"703\" data-end=\"719\"\u003e\n\u003cstrong data-start=\"705\" data-end=\"715\"\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli data-start=\"720\" data-end=\"748\"\u003e\n\u003cstrong data-start=\"722\" data-end=\"733\"\u003eFamily:\u003c\/strong\u003e SACE Isomax S3\u003c\/li\u003e\n\u003cli data-start=\"749\" data-end=\"769\"\u003e\n\u003cstrong data-start=\"751\" data-end=\"761\"\u003eModel:\u003c\/strong\u003e S3N 250\u003c\/li\u003e\n\u003cli data-start=\"770\" data-end=\"809\"\u003e\n\u003cstrong data-start=\"772\" data-end=\"781\"\u003eType:\u003c\/strong\u003e Molded-case circuit breaker\u003c\/li\u003e\n\u003cli data-start=\"810\" data-end=\"839\"\u003e\n\u003cstrong data-start=\"812\" data-end=\"832\"\u003eNumber of poles:\u003c\/strong\u003e \u003cstrong data-start=\"833\" data-end=\"839\"\u003e4P\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"840\" data-end=\"896\"\u003e\n\u003cstrong data-start=\"842\" data-end=\"877\"\u003eRated uninterrupted current Iu:\u003c\/strong\u003e \u003cstrong data-start=\"878\" data-end=\"896\"\u003e250 A at 40 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"897\" data-end=\"951\"\u003e\n\u003cstrong data-start=\"899\" data-end=\"932\"\u003eRated operational voltage Ue:\u003c\/strong\u003e up to \u003cstrong data-start=\"939\" data-end=\"951\"\u003e690 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"952\" data-end=\"981\"\u003e\n\u003cstrong data-start=\"954\" data-end=\"968\"\u003eFrequency:\u003c\/strong\u003e \u003cstrong data-start=\"969\" data-end=\"981\"\u003e50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"982\" data-end=\"1028\"\u003e\n\u003cstrong data-start=\"984\" data-end=\"1019\"\u003eImpulse withstand voltage Uimp:\u003c\/strong\u003e \u003cstrong data-start=\"1020\" data-end=\"1028\"\u003e8 kV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1029\" data-end=\"1060\"\u003e\n\u003cstrong data-start=\"1031\" data-end=\"1044\"\u003eStandard:\u003c\/strong\u003e \u003cstrong data-start=\"1045\" data-end=\"1060\"\u003eIEC 60947-2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1061\" data-end=\"1112\"\u003e\n\u003cstrong data-start=\"1063\" data-end=\"1102\"\u003eBreaking capacity Icu at 380\/415 V:\u003c\/strong\u003e \u003cstrong data-start=\"1103\" data-end=\"1112\"\u003e35 kA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1113\" data-end=\"1142\"\u003e\n\u003cstrong data-start=\"1115\" data-end=\"1140\"\u003eUtilization category:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli data-start=\"1143\" data-end=\"1226\"\u003e\n\u003cstrong data-start=\"1145\" data-end=\"1171\"\u003eProtection technology:\u003c\/strong\u003e thermal-magnetic trip unit, depending on configuration\u003c\/li\u003e\n\u003cli data-start=\"1227\" data-end=\"1289\"\u003e\n\u003cstrong data-start=\"1229\" data-end=\"1246\"\u003eConstruction:\u003c\/strong\u003e SACE Isomax S3 molded-case circuit breaker\u003c\/li\u003e\n\u003cli data-start=\"1290\" data-end=\"1324\"\u003e\n\u003cstrong data-start=\"1292\" data-end=\"1304\"\u003eControl:\u003c\/strong\u003e front rotary handle\u003c\/li\u003e\n\u003cli data-start=\"1325\" data-end=\"1652\"\u003e\n\u003cstrong data-start=\"1327\" data-end=\"1343\"\u003eConnections:\u003c\/strong\u003e front power terminals visible in the photographs.\u003cbr\u003e\u003cstrong data-start=\"1394\" data-end=\"1413\"\u003eImportant Note:\u003c\/strong\u003e ABB documentation provides different S3N 250 configurations with different trip units and settings. The complete ABB code or a specific trip-unit setting that is not clearly legible cannot therefore be assigned from the photographs alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1653\" data-end=\"1678\"\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong data-start=\"1660\" data-end=\"1678\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1679\" data-end=\"2203\"\u003e\n\u003cli data-start=\"1679\" data-end=\"1734\"\u003eProtection of electrical lines against \u003cstrong data-start=\"1720\" data-end=\"1733\"\u003eoverloads\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1783\"\u003eProtection against \u003cstrong data-start=\"1756\" data-end=\"1782\"\u003eshort-circuit currents\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-start=\"1784\" data-end=\"1830\"\u003eCircuit interruption under fault conditions.\u003c\/li\u003e\n\u003cli data-start=\"1831\" data-end=\"1869\"\u003eManual line isolation and switching.\u003c\/li\u003e\n\u003cli data-start=\"1870\" data-end=\"1949\"\u003eProtection of equipment and conductors in industrial electrical switchboards.\u003c\/li\u003e\n\u003cli data-start=\"1950\" data-end=\"2203\"\u003ePossibility of integration with accessories and auxiliary devices provided for the SACE Isomax family.\u003cbr\u003eABB documents different configurations of the S3N series with thermal-magnetic and magnetic trip units, as well as different versions and terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2204\" data-end=\"2236\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"2211\" data-end=\"2236\"\u003ePurpose and Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2237\" data-end=\"2706\"\u003eThe circuit breaker is installed inside an electrical switchboard to protect a line or power load.\u003cbr\u003eDuring normal operation, it allows current to flow up to its rated current. In the event of an overload or short-circuit condition, the trip unit operates the opening mechanism, opening the contacts and interrupting the circuit.\u003cbr\u003eThe \u003cstrong data-start=\"2569\" data-end=\"2580\"\u003eS3N 250\u003c\/strong\u003e is rated for an uninterrupted current of \u003cstrong data-start=\"2622\" data-end=\"2640\"\u003e250 A at 40 °C\u003c\/strong\u003e. ABB specifies an \u003cstrong data-start=\"2659\" data-end=\"2688\"\u003eIcu of 35 kA at 380\/415 V\u003c\/strong\u003e for this version.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"2707\" data-end=\"2738\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"2714\" data-end=\"2738\"\u003eDevice Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2739\" data-end=\"2760\"\u003eThe photographs show:\u003c\/p\u003e\n\u003cul data-start=\"2761\" data-end=\"3160\"\u003e\n\u003cli data-start=\"2761\" data-end=\"2793\"\u003eABB SACE circuit breaker body;\u003c\/li\u003e\n\u003cli data-start=\"2794\" data-end=\"2827\"\u003e\n\u003cstrong data-start=\"2796\" data-end=\"2802\"\u003eS3\u003c\/strong\u003e indication on the front;\u003c\/li\u003e\n\u003cli data-start=\"2828\" data-end=\"2852\"\u003erotary control handle;\u003c\/li\u003e\n\u003cli data-start=\"2853\" data-end=\"2890\"\u003ecircuit-breaker position indicator;\u003c\/li\u003e\n\u003cli data-start=\"2891\" data-end=\"2904\"\u003efour poles;\u003c\/li\u003e\n\u003cli data-start=\"2905\" data-end=\"2923\"\u003epower terminals;\u003c\/li\u003e\n\u003cli data-start=\"2924\" data-end=\"2947\"\u003etrip\/protection unit;\u003c\/li\u003e\n\u003cli data-start=\"2948\" data-end=\"3160\"\u003eside auxiliary wiring\/accessory.\u003cbr\u003eThe presence of the side wiring is simply reported as \u003cstrong data-start=\"3037\" data-end=\"3075\"\u003eauxiliary accessory\/wiring present\u003c\/strong\u003e, without assigning a specific function that cannot be verified from the photographs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3161\" data-end=\"3199\"\u003e\u003cspan role=\"text\"\u003e⚠️ \u003cstrong data-start=\"3168\" data-end=\"3199\"\u003eTypical Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3200\" data-end=\"3243\"\u003eA circuit breaker of this type may exhibit:\u003c\/p\u003e\n\u003cul data-start=\"3244\" data-end=\"3752\"\u003e\n\u003cli data-start=\"3244\" data-end=\"3303\"\u003einability to move the circuit breaker to the ON position;\u003c\/li\u003e\n\u003cli data-start=\"3304\" data-end=\"3343\"\u003eimmediate tripping upon switching on;\u003c\/li\u003e\n\u003cli data-start=\"3344\" data-end=\"3374\"\u003etripping during an overload;\u003c\/li\u003e\n\u003cli data-start=\"3375\" data-end=\"3393\"\u003efailure to open;\u003c\/li\u003e\n\u003cli data-start=\"3394\" data-end=\"3413\"\u003efailure to close;\u003c\/li\u003e\n\u003cli data-start=\"3414\" data-end=\"3441\"\u003eworn or damaged contacts;\u003c\/li\u003e\n\u003cli data-start=\"3442\" data-end=\"3467\"\u003edeteriorated terminals;\u003c\/li\u003e\n\u003cli data-start=\"3468\" data-end=\"3497\"\u003eoverheating of connections;\u003c\/li\u003e\n\u003cli data-start=\"3498\" data-end=\"3528\"\u003econtrol-mechanism anomalies;\u003c\/li\u003e\n\u003cli data-start=\"3529\" data-end=\"3752\"\u003eproblems with the trip unit or any auxiliary accessories.\u003cbr\u003eA circuit-breaker trip does not necessarily mean that the circuit breaker itself is faulty: it may be caused by an overload or short circuit present in the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3753\" data-end=\"3773\"\u003e\u003cspan role=\"text\"\u003e🔍 \u003cstrong data-start=\"3760\" data-end=\"3773\"\u003eDiagnosis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3774\" data-end=\"3810\"\u003eProfessional inspection may include:\u003c\/p\u003e\n\u003cul data-start=\"3811\" data-end=\"4252\"\u003e\n\u003cli data-start=\"3811\" data-end=\"3855\"\u003emechanical check of the control mechanism;\u003c\/li\u003e\n\u003cli data-start=\"3856\" data-end=\"3899\"\u003everification of pole opening and closing;\u003c\/li\u003e\n\u003cli data-start=\"3900\" data-end=\"3922\"\u003eterminal inspection;\u003c\/li\u003e\n\u003cli data-start=\"3923\" data-end=\"3944\"\u003einsulation testing;\u003c\/li\u003e\n\u003cli data-start=\"3945\" data-end=\"3974\"\u003econtact continuity testing;\u003c\/li\u003e\n\u003cli data-start=\"3975\" data-end=\"4000\"\u003etrip-unit verification;\u003c\/li\u003e\n\u003cli data-start=\"4001\" data-end=\"4038\"\u003echecking of any auxiliary contacts;\u003c\/li\u003e\n\u003cli data-start=\"4039\" data-end=\"4077\"\u003einspection of connection conditions;\u003c\/li\u003e\n\u003cli data-start=\"4078\" data-end=\"4252\"\u003efunctional testing with appropriate equipment.\u003cbr\u003eFor a complete inspection, the specific configuration of the trip unit and any installed accessories must also be considered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4253\" data-end=\"4299\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"4261\" data-end=\"4299\"\u003eCommon Services in Case of Failure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4300\" data-end=\"4631\"\u003e\n\u003cli data-start=\"4300\" data-end=\"4330\"\u003eCircuit-breaker diagnostics.\u003c\/li\u003e\n\u003cli data-start=\"4331\" data-end=\"4355\"\u003eMechanical inspection.\u003c\/li\u003e\n\u003cli data-start=\"4356\" data-end=\"4383\"\u003eCleaning and maintenance.\u003c\/li\u003e\n\u003cli data-start=\"4384\" data-end=\"4405\"\u003eContact inspection.\u003c\/li\u003e\n\u003cli data-start=\"4406\" data-end=\"4428\"\u003eTerminal inspection.\u003c\/li\u003e\n\u003cli data-start=\"4429\" data-end=\"4452\"\u003eTrip-unit inspection.\u003c\/li\u003e\n\u003cli data-start=\"4453\" data-end=\"4486\"\u003eAuxiliary-accessory inspection.\u003c\/li\u003e\n\u003cli data-start=\"4487\" data-end=\"4526\"\u003eReplacement of compatible components.\u003c\/li\u003e\n\u003cli data-start=\"4527\" data-end=\"4570\"\u003eFunctional testing before reinstallation.\u003c\/li\u003e\n\u003cli data-start=\"4571\" data-end=\"4631\"\u003eCircuit-breaker refurbishment, where technically possible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4632\" data-end=\"4656\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"4640\" data-end=\"4656\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4657\" data-end=\"4726\"\u003eThe \u003cstrong data-start=\"4661\" data-end=\"4688\"\u003eABB SACE Isomax S3N 250\u003c\/strong\u003e is suitable for applications such as:\u003c\/p\u003e\n\u003cul data-start=\"4727\" data-end=\"5062\"\u003e\n\u003cli data-start=\"4727\" data-end=\"4764\"\u003eindustrial electrical switchboards;\u003c\/li\u003e\n\u003cli data-start=\"4765\" data-end=\"4803\"\u003elow-voltage electrical distribution;\u003c\/li\u003e\n\u003cli data-start=\"4804\" data-end=\"4851\"\u003eprotection of three-phase lines with neutral;\u003c\/li\u003e\n\u003cli data-start=\"4852\" data-end=\"4875\"\u003eindustrial machinery;\u003c\/li\u003e\n\u003cli data-start=\"4876\" data-end=\"4904\"\u003edistribution switchboards;\u003c\/li\u003e\n\u003cli data-start=\"4905\" data-end=\"4995\"\u003ephotovoltaic systems and conversion systems, when provided for by the electrical design;\u003c\/li\u003e\n\u003cli data-start=\"4996\" data-end=\"5062\"\u003eprotection of loads and lines up to the specified rated current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"5063\" data-end=\"5084\"\u003e\u003cspan role=\"text\"\u003e💡 \u003cstrong data-start=\"5070\" data-end=\"5084\"\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5085\" data-end=\"5435\"\u003e\n\u003cli data-start=\"5085\" data-end=\"5120\"\u003eHigh current-handling capability.\u003c\/li\u003e\n\u003cli data-start=\"5121\" data-end=\"5171\"\u003eRobust construction for industrial applications.\u003c\/li\u003e\n\u003cli data-start=\"5172\" data-end=\"5204\"\u003eRated current up to \u003cstrong data-start=\"5194\" data-end=\"5203\"\u003e250 A\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-start=\"5205\" data-end=\"5244\"\u003eOperating voltage up to \u003cstrong data-start=\"5231\" data-end=\"5243\"\u003e690 V AC\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-start=\"5245\" data-end=\"5285\"\u003eOverload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"5286\" data-end=\"5339\"\u003eCompact construction relative to the power handled.\u003c\/li\u003e\n\u003cli data-start=\"5340\" data-end=\"5435\"\u003eWide historical availability of accessories and configurations within the SACE Isomax family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"5436\" data-end=\"5465\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"5444\" data-end=\"5465\"\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5466\" data-end=\"5668\"\u003e\u003cstrong data-start=\"5466\" data-end=\"5483\"\u003eUsed product.\u003c\/strong\u003e\u003cbr\u003eThe circuit breaker shows normal signs of use and wear consistent with a used industrial component.\u003cbr\u003eThe photographs do not allow the electrical operation of the device to be certified.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"5669\" data-end=\"5696\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"5676\" data-end=\"5696\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5697\" data-end=\"5841\"\u003e\n\u003cli data-start=\"5697\" data-end=\"5733\"\u003e1 × \u003cstrong data-start=\"5703\" data-end=\"5733\"\u003eABB SACE Isomax S3N 250 4P\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5734\" data-end=\"5841\"\u003eWiring\/accessories visible in the photographs, if present and supplied together with the circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"5842\" data-end=\"5860\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"5849\" data-end=\"5860\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5861\" data-end=\"6411\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"5865\" data-end=\"5895\"\u003eABB SACE Isomax S3N 250 4P\u003c\/strong\u003e is an ABB molded-case circuit breaker intended for the protection and isolation of industrial electrical circuits.\u003cbr\u003eThe configuration identifiable from the photographs is \u003cstrong data-start=\"6066\" data-end=\"6086\"\u003eS3N 250, 4 poles\u003c\/strong\u003e, with \u003cstrong data-start=\"6093\" data-end=\"6105\"\u003eIu 250 A\u003c\/strong\u003e, \u003cstrong data-start=\"6107\" data-end=\"6128\"\u003eUe up to 690 V AC\u003c\/strong\u003e, \u003cstrong data-start=\"6130\" data-end=\"6143\"\u003eUimp 8 kV\u003c\/strong\u003e, and \u003cstrong data-start=\"6149\" data-end=\"6164\"\u003eIEC 60947-2\u003c\/strong\u003e. ABB documents an \u003cstrong data-start=\"6183\" data-end=\"6212\"\u003eIcu of 35 kA at 380\/415 V\u003c\/strong\u003e for the S3N 250 version.\u003cbr\u003e\u003cstrong data-start=\"6238\" data-end=\"6261\"\u003eCompatibility Note:\u003c\/strong\u003e Before replacement, always verify the S3N model, number of poles, trip-unit type and settings, terminal configuration, and any installed accessories.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":54985054585165,"sku":null,"price":260.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7118.jpg?v=1791469938","url":"https:\/\/greenenergy-repair.com\/products\/abb-sace-s3n-250-4p-250-a-690-v-ac-mccb","provider":"Green Energy","version":"1.0","type":"link"}