{"product_id":"abb-power-one-aurora-3-phase-ac-filter-inductor-pvi-10-0-pvi-12-5-kw","title":"ABB Power-One Aurora | 3-Phase AC Filter Inductor | PVI-10.0 \/ PVI-12.5 kW","description":"\u003ch3\u003e\n\u003cspan\u003e📝 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eUsed product.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Three-phase inductor assembly intended, according to the available identification, for the AC output filtering section of ABB \/ Power-One Aurora photovoltaic inverters.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe component consists of three coils wound around magnetic cores, mounted on a metal support and complete with wiring, pin terminals and a screw terminal block. The connections are marked R, S and T, corresponding to the three phases of the circuit.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe assembly is associated with the AC filtering section of Aurora PVI-10.0 and PVI-12.5-TL-OUTD inverter families. In this section, the inductive components help filter the output current before the energy is fed into the electrical grid. ABB documentation illustrates the line filter and grid-parallel relay within the inverter architecture.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe exact function and compatibility with individual revisions must be confirmed using the replacement part number and by comparing the component with the original. The associated board code, 3G83 Pb-Free, and references to errors E030, E031, E032 and W003 must be verified for the specific model and do not constitute a definitive fault diagnosis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚙️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMain Specifications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReference equipment manufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ABB \/ Power-One Aurora.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eType:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Three-phase AC filtering inductor assembly.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDeclared application:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Inverter AC output.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eConfiguration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Three coils.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eConnections:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e R, S and T.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eConstruction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Magnetic cores with windings.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWiring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Black cables with pin terminals.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eConnections:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Three-section screw terminal block.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMounting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Metal support with mounting slots.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAssembly part number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not legible in the photographs.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAssociated filter\/relay board code:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3G83 Pb-Free, to be verified.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated electrical values:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not verified.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔌 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMain Functions\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eHelps filter three-phase alternating current.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReduces certain unwanted current components, depending on the circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eParticipates in the operation of the inverter's AC output section.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eContributes to the electromagnetic compatibility of the conversion system.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This is an inductor assembly; it cannot be stated that it constitutes the entire EMC\/EMI filter by itself.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚡ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRole Within the Inverter\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIn three-phase Aurora photovoltaic inverters, the energy generated by the panels is converted from direct current (DC) to alternating current (AC). The AC filtering section helps condition the current before connection to the electrical grid.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe pictured assembly is identified as an inductive component of this section. Its exact position in the circuit and its association with the filter and relay board must be verified against the relevant inverter revision.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e🧩 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatibility to be verified for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eABB \/ Power-One Aurora PVI-10.0-TL-OUTD.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eABB \/ Power-One Aurora PVI-12.5-TL-OUTD.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOther family variants, only after comparing the part number and original configuration.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCompatibility must not automatically be extended to all -S and -FS versions or to other Aurora inverters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🛠️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eRepair of three-phase photovoltaic inverters.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance of the AC output section.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement of damaged inductor assemblies.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRecovery of spare parts for compatible ABB \/ Power-One Aurora equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e💡 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAssembly with three inductors already installed.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWiring and terminal block included.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMetal support with mounting points.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePotential replacement part for maintenance work, subject to compatibility verification.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🛡️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eProduct Condition\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUsed component with signs of wear. Electrical functionality has not been tested.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBefore reuse, check winding continuity, electrical insulation, terminal condition and whether the rated values match those of the original component.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e📦 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePackage Contents\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003e1 × three-phase inductor assembly with wiring, terminal block and metal support, as shown in the photographs.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🟢 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSummary\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThree-phase inductor assembly intended, according to the available identification, for the AC filtering section of  PVI-10.0 and PVI-12.5 kW photovoltaic inverters. The exact part number and compatibility with individual revisions must be verified before purchase and installation.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB \/ Power-One Aurora","offers":[{"title":"Default Title","offer_id":55152903749965,"sku":null,"price":60.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7225.jpg?v=1792680803","url":"https:\/\/greenenergy-repair.com\/products\/abb-power-one-aurora-3-phase-ac-filter-inductor-pvi-10-0-pvi-12-5-kw","provider":"Green Energy","version":"1.0","type":"link"}