{"product_id":"abb-a95-30-power-contactor-3-pole-95-a-690-v-ac-coil-110-250-v-ac-dc-ca5-10-1no-rv5-250-iec-60947","title":"ABB A95-30 Power Contactor | 3-Pole | 95 A | 690 V AC | Coil 110–250 V AC\/DC | CA5-10 1NO | RV5\/250 | IEC 60947","description":"\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eUsed product.\u003c\/strong\u003e The \u003cstrong\u003eABB A95-30\u003c\/strong\u003e is a \u003cstrong\u003epower contactor\u003c\/strong\u003e from the ABB A95 series, designed for controlling and switching \u003cstrong\u003ethree-phase motors and industrial power circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe contactor features \u003cstrong\u003e3 main poles\u003c\/strong\u003e, with power terminals \u003cstrong\u003e1L1–2T1, 3L2–4T2, and 5L3–6T3\u003c\/strong\u003e, and is equipped with an \u003cstrong\u003eABB CA5-10 auxiliary contact block\u003c\/strong\u003e, configured with \u003cstrong\u003e1 normally open contact (1NO)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe contactor is also fitted with an \u003cstrong\u003eABB RV5\/250 surge suppressor\u003c\/strong\u003e, designed for control circuits with a \u003cstrong\u003e110–250 V AC\/DC coil\u003c\/strong\u003e, helping to suppress voltage peaks generated when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThe unit shows \u003cstrong\u003enormal signs of previous use\u003c\/strong\u003e, including light abrasions and superficial marks on the plastic and metal components. The \u003cstrong\u003econtrol wiring connected to the accessories\u003c\/strong\u003e is also present, as shown in the photographs.\u003c\/p\u003e\n\u003cp\u003eElectrical operation cannot be certified from visual inspection alone. Before installation, it is therefore recommended to check the coil, continuity of the main and auxiliary contacts, and electrical insulation.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e A95\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eA95-30\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Three-phase power contactor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Main Poles:\u003c\/strong\u003e \u003cstrong\u003e3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Free-Air Thermal Current Ith:\u003c\/strong\u003e \u003cstrong\u003e145 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated AC-1 Current:\u003c\/strong\u003e \u003cstrong\u003e145 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage Ui:\u003c\/strong\u003e \u003cstrong\u003e1000 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Withstand Voltage Uimp:\u003c\/strong\u003e \u003cstrong\u003e8 kV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e \u003cstrong\u003eAC-3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e \u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e \u003cstrong\u003eIEC 947-4-1 \/ EN 60947-4-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicated Production:\u003c\/strong\u003e \u003cstrong\u003eMade in Sweden\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eAC-3 Rated Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e220–240 V:\u003c\/strong\u003e \u003cstrong\u003e25 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e380–400 V:\u003c\/strong\u003e \u003cstrong\u003e45 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e415–500 V:\u003c\/strong\u003e \u003cstrong\u003e55 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e660–690 V:\u003c\/strong\u003e \u003cstrong\u003e55 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000 V:\u003c\/strong\u003e \u003cstrong\u003e40 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt \u003cstrong\u003e400\/415 V\u003c\/strong\u003e, the A95 contactor has an AC-3 current rating in the range of approximately \u003cstrong\u003e95–96 A\u003c\/strong\u003e, depending on the operating voltage and configuration.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eABB CA5-10 Auxiliary Contact Block\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e CA5-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e \u003cstrong\u003e1NO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Front-mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Auxiliary Circuit Voltage:\u003c\/strong\u003e up to \u003cstrong\u003e690 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB Code:\u003c\/strong\u003e \u003cstrong\u003e1SBN010010R1010\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eABB RV5\/250 Surge Suppressor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RV5\/250\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Coil overvoltage suppression\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Circuit Voltage:\u003c\/strong\u003e \u003cstrong\u003e110–250 V AC\/DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Clip-on mounting to the contactor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB Code:\u003c\/strong\u003e \u003cstrong\u003e1SBN050010R1002\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong\u003eFunction in the Electrical System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB A95-30\u003c\/strong\u003e is used for \u003cstrong\u003eswitching and controlling high-power electrical loads\u003c\/strong\u003e, particularly three-phase motors, industrial lines, pumps, fans, compressors, and automation equipment.\u003c\/p\u003e\n\u003cp\u003eWhen the contactor coil is energized, the three main contacts operate simultaneously, allowing the load to be supplied through the three phases.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eCA5-10\u003c\/strong\u003e provides a \u003cstrong\u003e1NO auxiliary contact\u003c\/strong\u003e, which can be used for signaling, self-holding circuits, interlocking, or connection to control and monitoring circuits.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV5\/250\u003c\/strong\u003e helps suppress voltage peaks generated when the contactor coil is de-energized, helping protect the associated control circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🏭 \u003cstrong\u003eConstruction \u0026amp; Installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe contactor features the typical compact construction of the \u003cstrong\u003eABB A95 series\u003c\/strong\u003e, designed for installation in \u003cstrong\u003eelectrical panels, automation cabinets, motor starters, and industrial equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe main power terminals are clearly identified:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1L1 \/ 2T1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3L2 \/ 4T2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5L3 \/ 6T3\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe assembly includes the front-mounted \u003cstrong\u003eCA5-10 auxiliary contact block\u003c\/strong\u003e and the \u003cstrong\u003eRV5\/250 surge suppressor\u003c\/strong\u003e installed on the contactor.\u003c\/p\u003e\n\u003cp\u003eBefore installation, the following should be verified:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eRated current of the circuit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOperating voltage\u003c\/li\u003e\n\u003cli\u003eWiring diagram\u003c\/li\u003e\n\u003cli\u003eConductor sizing\u003c\/li\u003e\n\u003cli\u003eRequired switching capacity\u003c\/li\u003e\n\u003cli\u003eCorrect supply voltage for the \u003cstrong\u003e110–250 V AC\/DC control circuit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallation must be performed by \u003cstrong\u003equalified personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🌐 \u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB A95-30\u003c\/strong\u003e may be used in industrial applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eThree-phase motor starting and control\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIndustrial electrical panels\u003c\/li\u003e\n\u003cli\u003ePumps and material-handling systems\u003c\/li\u003e\n\u003cli\u003eIndustrial HVAC fans and systems\u003c\/li\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eAutomatic machinery\u003c\/li\u003e\n\u003cli\u003ePower distribution and switching systems\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli\u003eMotor applications up to approximately \u003cstrong\u003e55 kW in AC-3\u003c\/strong\u003e, depending on supply voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e💡 \u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e95 A class power contactor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3 main power poles\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThermal current up to \u003cstrong\u003e145 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for applications up to \u003cstrong\u003e690 V AC\u003c\/strong\u003e, according to configuration\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUi 1000 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUimp 8 kV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCA5-10 1NO auxiliary contact included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRV5\/250 surge suppressor included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e110–250 V AC\/DC control circuit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eRobust ABB construction for industrial applications\u003c\/li\u003e\n\u003cli\u003eSuitable as a \u003cstrong\u003ereplacement component for existing ABB systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong\u003eSafety \u0026amp; Product Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e⚠️ \u003cstrong\u003eWARNING: EQUIPMENT INTENDED FOR ELECTRICAL POWER CIRCUITS.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe contactor must be installed and tested exclusively by \u003cstrong\u003equalified personnel\u003c\/strong\u003e, with the power supply completely disconnected and in accordance with the device's rated specifications and the requirements of the electrical system.\u003c\/p\u003e\n\u003cp\u003eThe component is \u003cstrong\u003eused\u003c\/strong\u003e and shows cosmetic signs consistent with previous installation, particularly on the external surfaces and metal components.\u003c\/p\u003e\n\u003cp\u003eThe correct operation of the \u003cstrong\u003emain contacts, mechanical mechanism, auxiliary CA5-10 contact, and RV5\/250 device\u003c\/strong\u003e cannot be certified from photographs alone.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, it is recommended to perform a complete mechanical and electrical inspection, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCoil verification\u003c\/li\u003e\n\u003cli\u003eMain contact continuity test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCA5-10 auxiliary contact\u003c\/strong\u003e test\u003c\/li\u003e\n\u003cli\u003eInsulation check\u003c\/li\u003e\n\u003cli\u003eTerminal inspection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRV5\/250\u003c\/strong\u003e verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1 × ABB A95-30 Power Contactor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 × ABB CA5-10 Auxiliary Contact Block – 1NO\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 × ABB RV5\/250 Surge Suppressor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eControl wiring and components visible in the photographs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🚀 \u003cstrong\u003eFinal Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB A95-30\u003c\/strong\u003e is a \u003cstrong\u003ethree-pole industrial power contactor\u003c\/strong\u003e designed for controlling motors and high-power electrical loads in professional applications.\u003c\/p\u003e\n\u003cp\u003eThe supplied configuration, complete with \u003cstrong\u003eCA5-10 1NO auxiliary contact\u003c\/strong\u003e and \u003cstrong\u003eRV5\/250 110–250 V AC\/DC surge suppressor\u003c\/strong\u003e, makes this component particularly interesting as a \u003cstrong\u003ereplacement for ABB electrical panels, motor control systems, and industrial automation equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe product is offered as \u003cstrong\u003eused\u003c\/strong\u003e, with normal signs of previous installation. \u003cstrong\u003eElectrical functionality has not been certified from visual inspection alone\u003c\/strong\u003e, so a complete functional test is recommended before use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":54649331908941,"sku":null,"price":85.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6655.jpg?v=1788453475","url":"https:\/\/greenenergy-repair.com\/products\/abb-a95-30-power-contactor-3-pole-95-a-690-v-ac-coil-110-250-v-ac-dc-ca5-10-1no-rv5-250-iec-60947","provider":"Green Energy","version":"1.0","type":"link"}