{"product_id":"used-ingeteam-ingecon-sun-lite-6tl-6000w-6kw-230vac-photovoltaic-inverter","title":"Ingeteam Ingecon Sun Lite 6TL 6000W 6kW Inverter Fotovoltaico Monofase Grid-Tie – 230V AC – Transformerless – MPPT Integrato – IP65","description":"\u003cp\u003eThe \u003cstrong\u003eIngeteam Ingecon Sun Lite 6TL\u003c\/strong\u003e is a single-phase grid-connected photovoltaic inverter designed to convert direct current (DC) generated by photovoltaic modules into alternating current (AC) synchronized with a \u003cstrong\u003e230V\u003c\/strong\u003e single-phase electrical grid.\u003cbr\u003eWith a nominal AC power of \u003cstrong\u003e6000W \/ 6kW\u003c\/strong\u003e, the device is suitable for high-power residential photovoltaic systems, light commercial installations and distributed generation systems. The INGECON SUN Lite TL series is a range of single-phase transformerless inverters designed for the residential sector and decentralized photovoltaic projects.\u003cbr\u003eTransformerless technology enables efficient energy conversion with a compact structure and reduced losses associated with the presence of a transformer. The MPPT tracking system optimizes the operating point of the photovoltaic array according to irradiation conditions and available voltage.\u003cbr\u003eThe inverter features a front LCD display, navigation keypad, status indicators and a diagnostic system for monitoring the main operating parameters and any alarm conditions. The Lite series documentation also indicates dedicated data logging and monitoring functions.\u003cbr\u003e\u003cstrong data-start=\"1300\" data-end=\"1320\"\u003e⚙️ Main Features\u003c\/strong\u003e\u003cbr\u003eSingle-Phase Grid-Connected Photovoltaic Inverter\u003cbr data-start=\"1370\" data-end=\"1373\"\u003eNominal AC Power: 6000W \/ 6kW\u003cbr data-start=\"1402\" data-end=\"1405\"\u003eGrid Voltage: 230V AC Single-Phase\u003cbr data-start=\"1439\" data-end=\"1442\"\u003eTL – Transformerless Technology\u003cbr data-start=\"1473\" data-end=\"1476\"\u003eIntegrated MPPT System\u003cbr data-start=\"1498\" data-end=\"1501\"\u003eFront LCD Display\u003cbr data-start=\"1518\" data-end=\"1521\"\u003eNavigation Keypad\u003cbr data-start=\"1538\" data-end=\"1541\"\u003eLED Status and Alarm Indicators\u003cbr data-start=\"1572\" data-end=\"1575\"\u003eOperating Parameter Monitoring\u003cbr data-start=\"1605\" data-end=\"1608\"\u003eIntegrated Diagnostics\u003cbr data-start=\"1630\" data-end=\"1633\"\u003eActive Cooling on Models of the Range Equipped with External Fans\u003cbr data-start=\"1698\" data-end=\"1701\"\u003eIP65 Environmental Protection\u003cbr data-start=\"1730\" data-end=\"1733\"\u003eSuitable for Grid-Tie Photovoltaic Systems\u003cbr\u003e\u003cstrong data-start=\"1776\" data-end=\"1807\"\u003e📋 Technical Specifications\u003c\/strong\u003e\u003cbr\u003eBrand: Ingeteam\u003cbr data-start=\"1823\" data-end=\"1826\"\u003eSeries: Ingecon Sun Lite\u003cbr data-start=\"1850\" data-end=\"1853\"\u003eModel: Ingecon Sun Lite 6TL\u003cbr data-start=\"1880\" data-end=\"1883\"\u003eType: Grid-Connected Photovoltaic Inverter\u003cbr data-start=\"1925\" data-end=\"1928\"\u003eGrid Configuration: Single-Phase\u003cbr data-start=\"1960\" data-end=\"1963\"\u003eNominal AC Power: 6000W \/ 6kW\u003cbr data-start=\"1992\" data-end=\"1995\"\u003eNominal AC Voltage: 230V AC\u003cbr data-start=\"2022\" data-end=\"2025\"\u003eNominal Frequency: 50Hz\u003cbr data-start=\"2048\" data-end=\"2051\"\u003eTechnology: Transformerless \/ TL\u003cbr data-start=\"2083\" data-end=\"2086\"\u003eNumber of MPPTs: 1 MPPT\u003cbr data-start=\"2109\" data-end=\"2112\"\u003eTracking System: Integrated MPPT\u003cbr data-start=\"2144\" data-end=\"2147\"\u003eUser Interface: Front LCD Display\u003cbr data-start=\"2180\" data-end=\"2183\"\u003eControls: Navigation Keypad\u003cbr data-start=\"2210\" data-end=\"2213\"\u003eIndicators: Status and Alarm LEDs\u003cbr data-start=\"2246\" data-end=\"2249\"\u003eEnvironmental Protection: IP65\u003cbr data-start=\"2279\" data-end=\"2282\"\u003eApplication: Grid-Connected Photovoltaic Systems\u003cbr\u003e\u003cstrong data-start=\"2331\" data-end=\"2365\"\u003e📝 Note on the Number of MPPTs\u003c\/strong\u003e\u003cbr\u003eThe older INGECON SUN Lite 6TL model should not be confused with the later 6TL M \/ 6TL M2 versions, which belong to different generations and may feature dual MPPT. For this Lite 6TL description, 1 MPPT is indicated based on the documentation of the older Lite series; the 2 MPPT configuration of newer M2 models should not be attributed to this version.\u003cbr\u003e\u003cstrong data-start=\"2721\" data-end=\"2748\"\u003e🔧 Integrated Functions\u003c\/strong\u003e\u003cbr\u003eThe inverter is designed to convert energy produced by the photovoltaic array into alternating current compatible with the single-phase electrical grid.\u003cbr\u003eMain Functions:\u003cbr\u003eAutomatic Maximum Power Point Tracking (MPPT)\u003cbr data-start=\"2963\" data-end=\"2966\"\u003eElectronic DC\/AC Conversion\u003cbr data-start=\"2993\" data-end=\"2996\"\u003eSynchronization with the Electrical Grid\u003cbr data-start=\"3036\" data-end=\"3039\"\u003eGrid Voltage and Frequency Monitoring\u003cbr data-start=\"3076\" data-end=\"3079\"\u003eOperating Parameter Control\u003cbr data-start=\"3106\" data-end=\"3109\"\u003eData Visualization via LCD Display\u003cbr data-start=\"3143\" data-end=\"3146\"\u003eAutomatic Diagnostics\u003cbr data-start=\"3167\" data-end=\"3170\"\u003eAlarm Management\u003cbr data-start=\"3186\" data-end=\"3189\"\u003eInverter Thermal Control\u003cbr data-start=\"3213\" data-end=\"3216\"\u003eOperating Data Logging and Monitoring\u003cbr data-start=\"3253\" data-end=\"3256\"\u003eProtection in Case of Electrical Parameters Outside Permitted Limits\u003cbr\u003e\u003cstrong data-start=\"3325\" data-end=\"3358\"\u003e⚠️ Possible Errors and Faults\u003c\/strong\u003e\u003cbr\u003eThe maintenance documentation for the single-phase INGECON SUN Lite family includes specific alarm and diagnostic codes. Main indications include:\u003cbr\u003e0001H – DC Input Voltage Insufficient or Outside Range\u003cbr data-start=\"3560\" data-end=\"3563\"\u003e0002H – Grid Frequency Outside Range\u003cbr data-start=\"3599\" data-end=\"3602\"\u003e0004H – Grid Voltage Outside Limits\u003cbr data-start=\"3637\" data-end=\"3640\"\u003e0008H – IGBT Inverter Bridge Overcurrent\u003cbr data-start=\"3680\" data-end=\"3683\"\u003e0010H – DC\/DC Converter Overcurrent\u003cbr data-start=\"3718\" data-end=\"3721\"\u003e0020H – Insulation Fault\u003cbr data-start=\"3745\" data-end=\"3748\"\u003e0040H – Grid-Side Overcurrent\u003cbr data-start=\"3777\" data-end=\"3780\"\u003e0080H – Inverter Overtemperature\u003cbr data-start=\"3812\" data-end=\"3815\"\u003eCOM ERROR \/ COMMS – Communication Error\u003cbr data-start=\"3854\" data-end=\"3857\"\u003eInternal Fan Fault\u003cbr data-start=\"3875\" data-end=\"3878\"\u003eExternal Fan Fault\u003cbr data-start=\"3896\" data-end=\"3899\"\u003ePower Limitation Due to High Temperature\u003cbr\u003eThe Lite family maintenance documentation also describes specific LED indications for fan problems and thermal power limitation; this is particularly relevant for models in the range equipped with external ventilation.\u003cbr\u003e\u003cstrong data-start=\"4159\" data-end=\"4179\"\u003e🔌 Compatibility\u003c\/strong\u003e\u003cbr\u003eCompatible, subject to verification of the electrical parameters of the installation, with:\u003cbr\u003eResidential Photovoltaic Systems\u003cbr data-start=\"4304\" data-end=\"4307\"\u003e230V Single-Phase Systems\u003cbr data-start=\"4332\" data-end=\"4335\"\u003eGrid-Tie Photovoltaic Installations\u003cbr data-start=\"4370\" data-end=\"4373\"\u003eCompatible Standard Photovoltaic Modules\u003cbr data-start=\"4413\" data-end=\"4416\"\u003eString Configurations Within the Specified DC Limits\u003cbr data-start=\"4468\" data-end=\"4471\"\u003eExisting Ingecon Sun Lite Installations\u003cbr data-start=\"4510\" data-end=\"4513\"\u003eRetrofit Applications\u003cbr data-start=\"4534\" data-end=\"4537\"\u003eReplacement of Compatible Inverters\u003cbr\u003e\u003cstrong data-start=\"4573\" data-end=\"4592\"\u003e🏭 Applications\u003c\/strong\u003e\u003cbr\u003eIdeal for:\u003cbr\u003eDomestic Solar Installations\u003cbr data-start=\"4632\" data-end=\"4635\"\u003eResidential Photovoltaic Systems of Approximately 6kW\u003cbr data-start=\"4688\" data-end=\"4691\"\u003eSmall Commercial Installations\u003cbr data-start=\"4721\" data-end=\"4724\"\u003eSingle-Phase PV Systems\u003cbr data-start=\"4747\" data-end=\"4750\"\u003eRetrofit of Existing Photovoltaic Installations\u003cbr data-start=\"4797\" data-end=\"4800\"\u003eReplacement of Compatible Ingecon Inverters\u003cbr data-start=\"4843\" data-end=\"4846\"\u003eDistributed Generation Systems\u003cbr\u003e\u003cstrong data-start=\"4877\" data-end=\"4894\"\u003e🌟 Advantages\u003c\/strong\u003e\u003cbr\u003e6kW Nominal Power\u003cbr data-start=\"4912\" data-end=\"4915\"\u003eTransformerless Technology\u003cbr data-start=\"4941\" data-end=\"4944\"\u003eIntegrated MPPT\u003cbr data-start=\"4959\" data-end=\"4962\"\u003eAutomatic Optimization of Photovoltaic Energy Production\u003cbr data-start=\"5018\" data-end=\"5021\"\u003eLCD Display for Monitoring and Diagnostics\u003cbr data-start=\"5063\" data-end=\"5066\"\u003eIntegrated Alarm Management\u003cbr data-start=\"5093\" data-end=\"5096\"\u003e230V Single-Phase Configuration\u003cbr data-start=\"5127\" data-end=\"5130\"\u003eIP65 Environmental Protection\u003cbr data-start=\"5159\" data-end=\"5162\"\u003eProfessional Structure for Photovoltaic Applications\u003cbr data-start=\"5214\" data-end=\"5217\"\u003eSuitable for Retrofit of Existing Installations\u003cbr\u003e\u003cstrong data-start=\"5265\" data-end=\"5289\"\u003e📦 Product Condition\u003c\/strong\u003e\u003cbr\u003eUsed Inverter\u003cbr data-start=\"5303\" data-end=\"5306\"\u003eCosmetic Condition to Be Verified According to the Photographs of the Individual Unit\u003cbr data-start=\"5391\" data-end=\"5394\"\u003ePossible Normal Signs and Traces of Use\u003cbr data-start=\"5433\" data-end=\"5436\"\u003eOperation Should Be Declared as Tested Only After an Actual Technical Test\u003cbr data-start=\"5510\" data-end=\"5513\"\u003eElectrical Compatibility Must Be Verified Before Installation\u003c\/p\u003e","brand":"INGETEAM inverter","offers":[{"title":"Default Title","offer_id":48348992176461,"sku":"","price":495.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/2b5e6a6e-87eb-48b6-96e4-bd33752f8699_95518ad1-e844-4eb8-a87c-30509b56be3e.png?v=1783518690","url":"https:\/\/greenenergy-repair.com\/pl\/products\/used-ingeteam-ingecon-sun-lite-6tl-6000w-6kw-230vac-photovoltaic-inverter","provider":"Green Energy","version":"1.0","type":"link"}