{"product_id":"thytronic-120163-kn0040-rev-02_e-display-reliable-interface-for-protection-systems","title":"Thyrtronic NV10P – Protection Relay | MV\/LV Network Control Unit | Digital Interface with LCD Display","description":"\u003cp data-start=\"149\" data-end=\"323\"\u003eThe \u003cstrong data-start=\"153\" data-end=\"173\"\u003eThyrtronic NV10P\u003c\/strong\u003e is a digital \u003cstrong data-start=\"187\" data-end=\"219\"\u003eprotection and control relay\u003c\/strong\u003e designed for electrical networks in \u003cstrong data-start=\"256\" data-end=\"322\"\u003eindustrial systems, photovoltaic plants, and MV\/LV substations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"325\" data-end=\"507\"\u003eThis device performs essential functions of \u003cstrong data-start=\"369\" data-end=\"408\"\u003emonitoring, protection, and control\u003c\/strong\u003e, ensuring system safety by detecting anomalies such as overvoltage, undervoltage, and grid faults.\u003c\/p\u003e\n\u003cp data-start=\"509\" data-end=\"670\"\u003eEquipped with a \u003cstrong data-start=\"525\" data-end=\"557\"\u003efront LCD display and keypad\u003c\/strong\u003e, it allows direct configuration of operating parameters and real-time visualization of system status and alarms.\u003c\/p\u003e\n\u003chr data-start=\"672\" data-end=\"675\"\u003e\n\u003ch3 data-start=\"677\" data-end=\"698\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"699\" data-end=\"968\"\u003e\n\u003cli data-start=\"699\" data-end=\"754\"\u003eVoltage protection (\u003cstrong data-start=\"721\" data-end=\"751\"\u003eovervoltage \/ undervoltage\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"755\" data-end=\"799\"\u003eContinuous electrical network monitoring\u003c\/li\u003e\n\u003cli data-start=\"800\" data-end=\"839\"\u003eControl of opening\/closing commands\u003c\/li\u003e\n\u003cli data-start=\"840\" data-end=\"869\"\u003eAlarm and fault signaling\u003c\/li\u003e\n\u003cli data-start=\"870\" data-end=\"915\"\u003eOperator interface via display and keypad\u003c\/li\u003e\n\u003cli data-start=\"916\" data-end=\"968\"\u003eCommunication with external systems (front port)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"970\" data-end=\"973\"\u003e\n\u003ch3 data-start=\"975\" data-end=\"1000\"\u003e🔌 Technical Features\u003c\/h3\u003e\n\u003cul data-start=\"1001\" data-end=\"1102\"\u003e\n\u003cli data-start=\"1001\" data-end=\"1021\"\u003eModel: \u003cstrong data-start=\"1010\" data-end=\"1019\"\u003eNV10P\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1071\"\u003eAuxiliary power supply: \u003cstrong data-start=\"1048\" data-end=\"1069\"\u003e110 – 230 V AC\/DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1072\" data-end=\"1102\"\u003eNominal voltage: \u003cstrong data-start=\"1091\" data-end=\"1100\"\u003e100 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1104\" data-end=\"1123\"\u003e\u003cstrong data-start=\"1104\" data-end=\"1123\"\u003eUser Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1124\" data-end=\"1211\"\u003e\n\u003cli data-start=\"1124\" data-end=\"1139\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-start=\"1140\" data-end=\"1172\"\u003eKeypad with function buttons\u003c\/li\u003e\n\u003cli data-start=\"1173\" data-end=\"1211\"\u003eStatus LEDs: \u003cstrong data-start=\"1188\" data-end=\"1209\"\u003eON \/ START \/ TRIP\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1213\" data-end=\"1231\"\u003e\u003cstrong data-start=\"1213\" data-end=\"1231\"\u003eCommunication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1232\" data-end=\"1288\"\u003e\n\u003cli data-start=\"1232\" data-end=\"1288\"\u003eFront communication port (RJ type for configuration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1290\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1290\" data-end=\"1307\"\u003eInstallation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1308\" data-end=\"1343\"\u003e\n\u003cli data-start=\"1308\" data-end=\"1343\"\u003eElectrical panels \/ substations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1345\" data-end=\"1348\"\u003e\n\u003ch3 data-start=\"1350\" data-end=\"1366\"\u003e🧠 Operation\u003c\/h3\u003e\n\u003cp data-start=\"1368\" data-end=\"1416\"\u003eThe relay continuously monitors grid parameters:\u003c\/p\u003e\n\u003cul data-start=\"1417\" data-end=\"1618\"\u003e\n\u003cli data-start=\"1417\" data-end=\"1463\"\u003eMeasures voltage and electrical conditions\u003c\/li\u003e\n\u003cli data-start=\"1464\" data-end=\"1510\"\u003eCompares values with configured thresholds\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1567\"\u003eActivates protection (\u003cstrong data-start=\"1535\" data-end=\"1543\"\u003eTRIP\u003c\/strong\u003e) in case of anomalies\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1618\"\u003eControls protection devices (circuit breakers)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1620\" data-end=\"1682\"\u003e👉 Ensures \u003cstrong data-start=\"1631\" data-end=\"1680\"\u003eautomatic protection of the electrical system\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1684\" data-end=\"1687\"\u003e\n\u003ch3 data-start=\"1689\" data-end=\"1710\"\u003e⚠️ Typical Faults\u003c\/h3\u003e\n\u003cul data-start=\"1711\" data-end=\"1873\"\u003e\n\u003cli data-start=\"1711\" data-end=\"1738\"\u003eUnwanted or false trips\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003eFailure to trip during faults\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1796\"\u003eDisplay malfunction\u003c\/li\u003e\n\u003cli data-start=\"1797\" data-end=\"1838\"\u003eCommunication or configuration issues\u003c\/li\u003e\n\u003cli data-start=\"1839\" data-end=\"1873\"\u003eIncorrect voltage measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1875\" data-end=\"1878\"\u003e\n\u003ch3 data-start=\"1880\" data-end=\"1902\"\u003e🔧 Problems Solved\u003c\/h3\u003e\n\u003cul data-start=\"1903\" data-end=\"2068\"\u003e\n\u003cli data-start=\"1903\" data-end=\"1936\"\u003eElectrical network protection\u003c\/li\u003e\n\u003cli data-start=\"1937\" data-end=\"1988\"\u003ePrevention of damage to inverters and equipment\u003c\/li\u003e\n\u003cli data-start=\"1989\" data-end=\"2029\"\u003eAutomatic handling of grid anomalies\u003c\/li\u003e\n\u003cli data-start=\"2030\" data-end=\"2068\"\u003eImproved system safety and control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2070\" data-end=\"2073\"\u003e\n\u003ch3 data-start=\"2075\" data-end=\"2094\"\u003e🏭 Applications\u003c\/h3\u003e\n\u003cul data-start=\"2095\" data-end=\"2230\"\u003e\n\u003cli data-start=\"2095\" data-end=\"2119\"\u003ePhotovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"2120\" data-end=\"2153\"\u003eMV\/LV transformer substations\u003c\/li\u003e\n\u003cli data-start=\"2154\" data-end=\"2176\"\u003eIndustrial systems\u003c\/li\u003e\n\u003cli data-start=\"2177\" data-end=\"2198\"\u003eProtection panels\u003c\/li\u003e\n\u003cli data-start=\"2199\" data-end=\"2230\"\u003ePower distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2232\" data-end=\"2235\"\u003e\n\u003ch3 data-start=\"2237\" data-end=\"2259\"\u003e🧩 Main Components\u003c\/h3\u003e\n\u003cul data-start=\"2260\" data-end=\"2427\"\u003e\n\u003cli data-start=\"2260\" data-end=\"2275\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-start=\"2276\" data-end=\"2294\"\u003eControl keypad\u003c\/li\u003e\n\u003cli data-start=\"2295\" data-end=\"2330\"\u003eStatus LEDs (ON \/ TRIP \/ START)\u003c\/li\u003e\n\u003cli data-start=\"2331\" data-end=\"2359\"\u003eInternal microcontroller\u003c\/li\u003e\n\u003cli data-start=\"2360\" data-end=\"2387\"\u003eCommunication interface\u003c\/li\u003e\n\u003cli data-start=\"2388\" data-end=\"2427\"\u003eMeasurement and protection circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2429\" data-end=\"2432\"\u003e\n\u003ch3 data-start=\"2434\" data-end=\"2458\"\u003e📦 Product Condition\u003c\/h3\u003e\n\u003cul data-start=\"2459\" data-end=\"2556\"\u003e\n\u003cli data-start=\"2459\" data-end=\"2488\"\u003eUsed \/ refurbished device\u003c\/li\u003e\n\u003cli data-start=\"2489\" data-end=\"2518\"\u003eComplete with front panel\u003c\/li\u003e\n\u003cli data-start=\"2519\" data-end=\"2556\"\u003eProfessional technical spare part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2558\" data-end=\"2561\"\u003e\n\u003ch3 data-start=\"2563\" data-end=\"2577\"\u003e💡 Summary\u003c\/h3\u003e\n\u003cp data-start=\"2579\" data-end=\"2662\"\u003eThe \u003cstrong data-start=\"2583\" data-end=\"2603\"\u003eThyrtronic NV10P\u003c\/strong\u003e is a reliable \u003cstrong data-start=\"2618\" data-end=\"2646\"\u003edigital protection relay\u003c\/strong\u003e, essential for:\u003c\/p\u003e\n\u003cp data-start=\"2664\" data-end=\"2760\"\u003e✔ Electrical system safety\u003cbr data-start=\"2690\" data-end=\"2693\"\u003e✔ Grid monitoring\u003cbr data-start=\"2710\" data-end=\"2713\"\u003e✔ Protection of inverters and connected loads\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":50570778837325,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5559.jpg?v=1777564915","url":"https:\/\/greenenergy-repair.com\/pl\/products\/thytronic-120163-kn0040-rev-02_e-display-reliable-interface-for-protection-systems","provider":"Green Energy","version":"1.0","type":"link"}