{"product_id":"solaredge-op300-mv-tycrm-4-300w-5-75v-10a-ottimizzatore-x-panelli-fotovoltaici","title":"SolarEdge OP300-MV Power Optimizer 300W 5–75V 10A IP65 for Photovoltaic Modules","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"83d85751-237a-4a4e-a941-ed508010bf88\" class=\"\"\u003e\n\u003csection data-turn=\"assistant\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-346\" data-turn-id-container=\"83d85751-237a-4a4e-a941-ed508010bf88\" data-turn-id=\"83d85751-237a-4a4e-a941-ed508010bf88\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" data-conversation-screenshot-content=\"\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-5\" dir=\"auto\" data-turn-start-message=\"true\" data-message-id=\"0bd1bcee-900a-42d2-8dcb-e0b947b50a54\" data-message-author-role=\"assistant\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch1 data-end=\"81\" data-start=\"0\"\u003eSolarEdge OP300-MV Power Optimizer 300W 5–75V 10A IP65 for Photovoltaic Modules\u003c\/h1\u003e\n\u003ch2 data-end=\"108\" data-start=\"83\"\u003e📘 Product Description\u003c\/h2\u003e\n\u003cp data-end=\"430\" data-start=\"110\"\u003eThe \u003cstrong data-end=\"136\" data-start=\"114\"\u003eSolarEdge OP300-MV\u003c\/strong\u003e is a photovoltaic power optimizer designed to maximize the energy production of individual solar modules. Integrated into SolarEdge systems, it provides module-level MPPT (Maximum Power Point Tracking) and continuous performance optimization, significantly improving overall system efficiency.\u003c\/p\u003e\n\u003cp data-end=\"749\" data-start=\"432\"\u003eThe optimizer compensates for performance losses caused by partial shading, dirt accumulation, module aging, manufacturing tolerances, and mismatches between solar panels. By allowing each module to operate independently at its optimal power point, the OP300-MV helps maximize energy harvest from the entire PV array.\u003c\/p\u003e\n\u003cp data-end=\"903\" data-start=\"751\"\u003eWith its \u003cstrong data-end=\"795\" data-start=\"760\"\u003eNEMA 4 \/ IP65 protection rating\u003c\/strong\u003e, the device is suitable for outdoor installation and long-term operation in harsh environmental conditions.\u003c\/p\u003e\n\u003chr data-end=\"908\" data-start=\"905\"\u003e\n\u003ch2 data-end=\"940\" data-start=\"910\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-end=\"965\" data-start=\"942\"\u003eIdentification Data\u003c\/h3\u003e\n\u003cul data-end=\"1055\" data-start=\"967\"\u003e\n\u003cli data-end=\"992\" data-start=\"967\"\u003eManufacturer: SolarEdge\u003c\/li\u003e\n\u003cli data-end=\"1010\" data-start=\"993\"\u003eModel: OP300-MV\u003c\/li\u003e\n\u003cli data-end=\"1055\" data-start=\"1011\"\u003eProduct Type: Photovoltaic Power Optimizer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1071\" data-start=\"1057\"\u003eInput (DC)\u003c\/h3\u003e\n\u003cul data-end=\"1193\" data-start=\"1073\"\u003e\n\u003cli data-end=\"1101\" data-start=\"1073\"\u003eMaximum Input Power: 300 W\u003c\/li\u003e\n\u003cli data-end=\"1135\" data-start=\"1102\"\u003eInput Voltage Range: 5 – 75 VDC\u003c\/li\u003e\n\u003cli data-end=\"1165\" data-start=\"1136\"\u003eMaximum Input Current: 10 A\u003c\/li\u003e\n\u003cli data-end=\"1193\" data-start=\"1166\"\u003eOpen Circuit Voltage: 1 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1210\" data-start=\"1195\"\u003eOutput (DC)\u003c\/h3\u003e\n\u003cul data-end=\"1288\" data-start=\"1212\"\u003e\n\u003cli data-end=\"1246\" data-start=\"1212\"\u003eOutput Voltage Range: 0 – 60 VDC\u003c\/li\u003e\n\u003cli data-end=\"1288\" data-start=\"1247\"\u003eMaximum Continuous Output Current: 15 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1315\" data-start=\"1290\"\u003eSystem Specifications\u003c\/h3\u003e\n\u003cul data-end=\"1432\" data-start=\"1317\"\u003e\n\u003cli data-end=\"1351\" data-start=\"1317\"\u003eMaximum System Voltage: 1000 VDC\u003c\/li\u003e\n\u003cli data-end=\"1386\" data-start=\"1352\"\u003eProtection Rating: NEMA 4 \/ IP65\u003c\/li\u003e\n\u003cli data-end=\"1432\" data-start=\"1387\"\u003eOperating Temperature Range: -40°C to +65°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1452\" data-start=\"1434\"\u003eCertifications\u003c\/h3\u003e\n\u003cul data-end=\"1481\" data-start=\"1454\"\u003e\n\u003cli data-end=\"1458\" data-start=\"1454\"\u003eCE\u003c\/li\u003e\n\u003cli data-end=\"1464\" data-start=\"1459\"\u003eFCC\u003c\/li\u003e\n\u003cli data-end=\"1481\" data-start=\"1465\"\u003eETL (Intertek)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1486\" data-start=\"1483\"\u003e\n\u003ch2 data-end=\"1507\" data-start=\"1488\"\u003e🔧 Main Features\u003c\/h2\u003e\n\u003cp data-end=\"1541\" data-start=\"1509\"\u003e✔ Module-level MPPT optimization\u003c\/p\u003e\n\u003cp data-end=\"1592\" data-start=\"1543\"\u003e✔ Increased photovoltaic system energy production\u003c\/p\u003e\n\u003cp data-end=\"1636\" data-start=\"1594\"\u003e✔ Reduced losses caused by partial shading\u003c\/p\u003e\n\u003cp data-end=\"1682\" data-start=\"1638\"\u003e✔ Compensation for module mismatch and aging\u003c\/p\u003e\n\u003cp data-end=\"1752\" data-start=\"1684\"\u003e✔ Individual module performance monitoring through SolarEdge systems\u003c\/p\u003e\n\u003cp data-end=\"1793\" data-start=\"1754\"\u003e✔ Advanced DC-side safety functionality\u003c\/p\u003e\n\u003cp data-end=\"1836\" data-start=\"1795\"\u003e✔ Greater flexibility in PV string design\u003c\/p\u003e\n\u003cp data-end=\"1868\" data-start=\"1838\"\u003e✔ Outdoor-rated IP65 enclosure\u003c\/p\u003e\n\u003chr data-end=\"1873\" data-start=\"1870\"\u003e\n\u003ch2 data-end=\"1902\" data-start=\"1875\"\u003e🔌 Purpose and Operation\u003c\/h2\u003e\n\u003cp data-end=\"2023\" data-start=\"1904\"\u003eThe SolarEdge OP300-MV continuously tracks and optimizes the maximum power point of each connected photovoltaic module.\u003c\/p\u003e\n\u003cp data-end=\"2195\" data-start=\"2025\"\u003eBy independently controlling module performance, it allows every panel to operate at its highest possible efficiency regardless of the performance of neighboring modules.\u003c\/p\u003e\n\u003cp data-end=\"2213\" data-start=\"2197\"\u003eThis results in:\u003c\/p\u003e\n\u003cul data-end=\"2388\" data-start=\"2215\"\u003e\n\u003cli data-end=\"2239\" data-start=\"2215\"\u003eIncreased energy yield\u003c\/li\u003e\n\u003cli data-end=\"2268\" data-start=\"2240\"\u003eImproved system efficiency\u003c\/li\u003e\n\u003cli data-end=\"2303\" data-start=\"2269\"\u003eEnhanced monitoring capabilities\u003c\/li\u003e\n\u003cli data-end=\"2353\" data-start=\"2304\"\u003eBetter performance under non-uniform conditions\u003c\/li\u003e\n\u003cli data-end=\"2388\" data-start=\"2354\"\u003eGreater installation flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2528\" data-start=\"2390\"\u003eThe optimizer communicates directly with compatible SolarEdge inverters and monitoring platforms to provide module-level performance data.\u003c\/p\u003e\n\u003chr data-end=\"2533\" data-start=\"2530\"\u003e\n\u003ch2 data-end=\"2553\" data-start=\"2535\"\u003e☀️ Applications\u003c\/h2\u003e\n\u003cp data-end=\"2565\" data-start=\"2555\"\u003eIdeal for:\u003c\/p\u003e\n\u003cul data-end=\"2807\" data-start=\"2567\"\u003e\n\u003cli data-end=\"2601\" data-start=\"2567\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-end=\"2634\" data-start=\"2602\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-end=\"2663\" data-start=\"2635\"\u003eRoofs with partial shading\u003c\/li\u003e\n\u003cli data-end=\"2684\" data-start=\"2664\"\u003eComplex PV layouts\u003c\/li\u003e\n\u003cli data-end=\"2715\" data-start=\"2685\"\u003eSolarEdge monitoring systems\u003c\/li\u003e\n\u003cli data-end=\"2755\" data-start=\"2716\"\u003eSystem upgrades and retrofit projects\u003c\/li\u003e\n\u003cli data-end=\"2807\" data-start=\"2756\"\u003eInstallations requiring module-level optimization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2812\" data-start=\"2809\"\u003e\n\u003ch2 data-end=\"2846\" data-start=\"2814\"\u003e⚠️ Common Faults and Symptoms\u003c\/h2\u003e\n\u003ch3 data-end=\"2877\" data-start=\"2848\"\u003eReduced Module Production\u003c\/h3\u003e\n\u003cp data-end=\"2888\" data-start=\"2879\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"2937\" data-start=\"2890\"\u003e❗ Lower energy output from the associated panel\u003c\/p\u003e\n\u003cp data-end=\"2967\" data-start=\"2939\"\u003e❗ Reduced string performance\u003c\/p\u003e\n\u003cp data-end=\"2997\" data-start=\"2969\"\u003e❗ Lower overall system yield\u003c\/p\u003e\n\u003ch3 data-end=\"3025\" data-start=\"2999\"\u003eCommunication Failures\u003c\/h3\u003e\n\u003cp data-end=\"3036\" data-start=\"3027\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"3078\" data-start=\"3038\"\u003e❗ Optimizer not detected by the inverter\u003c\/p\u003e\n\u003cp data-end=\"3124\" data-start=\"3080\"\u003e❗ Missing module data in monitoring platform\u003c\/p\u003e\n\u003cp data-end=\"3161\" data-start=\"3126\"\u003e❗ Intermittent communication errors\u003c\/p\u003e\n\u003ch3 data-end=\"3191\" data-start=\"3163\"\u003eString Voltage Anomalies\u003c\/h3\u003e\n\u003cp data-end=\"3202\" data-start=\"3193\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"3238\" data-start=\"3204\"\u003e❗ Abnormal string voltage readings\u003c\/p\u003e\n\u003cp data-end=\"3256\" data-start=\"3240\"\u003e❗ Startup issues\u003c\/p\u003e\n\u003cp data-end=\"3288\" data-start=\"3258\"\u003e❗ Reduced inverter performance\u003c\/p\u003e\n\u003ch3 data-end=\"3321\" data-start=\"3290\"\u003eInternal Electronic Failure\u003c\/h3\u003e\n\u003cp data-end=\"3332\" data-start=\"3323\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"3363\" data-start=\"3334\"\u003e❗ Complete optimizer shutdown\u003c\/p\u003e\n\u003cp data-end=\"3392\" data-start=\"3365\"\u003e❗ Module producing no power\u003c\/p\u003e\n\u003cp data-end=\"3422\" data-start=\"3394\"\u003e❗ System fault notifications\u003c\/p\u003e\n\u003ch3 data-end=\"3442\" data-start=\"3424\"\u003eThermal Issues\u003c\/h3\u003e\n\u003cp data-end=\"3453\" data-start=\"3444\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-end=\"3485\" data-start=\"3455\"\u003e❗ Excessive device temperature\u003c\/p\u003e\n\u003cp data-end=\"3519\" data-start=\"3487\"\u003e❗ Intermittent production losses\u003c\/p\u003e\n\u003cp data-end=\"3549\" data-start=\"3521\"\u003e❗ Safety shutdown activation\u003c\/p\u003e\n\u003chr data-end=\"3554\" data-start=\"3551\"\u003e\n\u003ch2 data-end=\"3588\" data-start=\"3556\"\u003e🚨 Possible Associated Errors\u003c\/h2\u003e\n\u003cp data-end=\"3627\" data-start=\"3590\"\u003eA faulty optimizer may contribute to:\u003c\/p\u003e\n\u003cul data-end=\"3901\" data-start=\"3629\"\u003e\n\u003cli data-end=\"3660\" data-start=\"3629\"\u003eOptimizer Communication Error\u003c\/li\u003e\n\u003cli data-end=\"3683\" data-start=\"3661\"\u003eString Voltage Fault\u003c\/li\u003e\n\u003cli data-end=\"3705\" data-start=\"3684\"\u003eModule Not Detected\u003c\/li\u003e\n\u003cli data-end=\"3731\" data-start=\"3706\"\u003ePower Optimizer Failure\u003c\/li\u003e\n\u003cli data-end=\"3748\" data-start=\"3732\"\u003eDC Input Error\u003c\/li\u003e\n\u003cli data-end=\"3780\" data-start=\"3749\"\u003eLow Module Production Warning\u003c\/li\u003e\n\u003cli data-end=\"3812\" data-start=\"3781\"\u003eMonitoring Communication Loss\u003c\/li\u003e\n\u003cli data-end=\"3830\" data-start=\"3813\"\u003ePV String Fault\u003c\/li\u003e\n\u003cli data-end=\"3860\" data-start=\"3831\"\u003eEnergy Production Reduction\u003c\/li\u003e\n\u003cli data-end=\"3901\" data-start=\"3861\"\u003eInverter Optimizer Communication Alarm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3990\" data-start=\"3903\"\u003eError messages may vary depending on the SolarEdge inverter model and firmware version.\u003c\/p\u003e\n\u003chr data-end=\"3995\" data-start=\"3992\"\u003e\n\u003ch2 data-end=\"4015\" data-start=\"3997\"\u003e🛠 Applications\u003c\/h2\u003e\n\u003cp data-end=\"4030\" data-start=\"4017\"\u003eSuitable for:\u003c\/p\u003e\n\u003cp data-end=\"4066\" data-start=\"4032\"\u003e✔ SolarEdge residential PV systems\u003c\/p\u003e\n\u003cp data-end=\"4107\" data-start=\"4068\"\u003e✔ Commercial photovoltaic installations\u003c\/p\u003e\n\u003cp data-end=\"4138\" data-start=\"4109\"\u003e✔ Shaded rooftop applications\u003c\/p\u003e\n\u003cp data-end=\"4182\" data-start=\"4140\"\u003e✔ Advanced module-level monitoring systems\u003c\/p\u003e\n\u003cp data-end=\"4231\" data-start=\"4184\"\u003e✔ PV system upgrades and modernization projects\u003c\/p\u003e\n\u003cp data-end=\"4284\" data-start=\"4233\"\u003e✔ Performance optimization of existing solar arrays\u003c\/p\u003e\n\u003chr data-end=\"4289\" data-start=\"4286\"\u003e\n\u003ch2 data-end=\"4306\" data-start=\"4291\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cp data-end=\"4341\" data-start=\"4308\"\u003e✔ Module-level power optimization\u003c\/p\u003e\n\u003cp data-end=\"4369\" data-start=\"4343\"\u003e✔ Increased energy harvest\u003c\/p\u003e\n\u003cp data-end=\"4396\" data-start=\"4371\"\u003e✔ Reduced mismatch losses\u003c\/p\u003e\n\u003cp data-end=\"4445\" data-start=\"4398\"\u003e✔ Improved performance under shading conditions\u003c\/p\u003e\n\u003cp data-end=\"4481\" data-start=\"4447\"\u003e✔ Advanced monitoring capabilities\u003c\/p\u003e\n\u003cp data-end=\"4512\" data-start=\"4483\"\u003e✔ Enhanced DC safety features\u003c\/p\u003e\n\u003cp data-end=\"4538\" data-start=\"4514\"\u003e✔ Flexible system design\u003c\/p\u003e\n\u003cp data-end=\"4538\" data-start=\"4514\"\u003e✔ Proven SolarEdge reliability\u003c\/p\u003e\n\u003chr data-end=\"4575\" data-start=\"4572\"\u003e\n\u003ch2 data-end=\"4599\" data-start=\"4577\"\u003e📦 Package Contents\u003c\/h2\u003e\n\u003cul data-end=\"4767\" data-start=\"4601\"\u003e\n\u003cli data-end=\"4641\" data-start=\"4601\"\u003e1 × SolarEdge OP300-MV Power Optimizer\u003c\/li\u003e\n\u003cli data-end=\"4679\" data-start=\"4642\"\u003eIntegrated input and output cabling\u003c\/li\u003e\n\u003cli data-end=\"4719\" data-start=\"4680\"\u003eOriginal factory-installed connectors\u003c\/li\u003e\n\u003cli data-end=\"4767\" data-start=\"4720\"\u003eCosmetic condition as shown in product photos\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4772\" data-start=\"4769\"\u003e\n\u003ch2 data-end=\"4793\" data-start=\"4774\"\u003e🔄 Compatibility\u003c\/h2\u003e\n\u003cp data-end=\"4811\" data-start=\"4795\"\u003eCompatible with:\u003c\/p\u003e\n\u003cul data-end=\"5000\" data-start=\"4813\"\u003e\n\u003cli data-end=\"4845\" data-start=\"4813\"\u003eSolarEdge photovoltaic systems\u003c\/li\u003e\n\u003cli data-end=\"4878\" data-start=\"4846\"\u003eCompatible SolarEdge inverters\u003c\/li\u003e\n\u003cli data-end=\"4918\" data-start=\"4879\"\u003eModule-level monitoring installations\u003c\/li\u003e\n\u003cli data-end=\"4958\" data-start=\"4919\"\u003eResidential and commercial PV systems\u003c\/li\u003e\n\u003cli data-end=\"5000\" data-start=\"4959\"\u003eSolarEdge optimizer-based architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"5070\" data-start=\"5002\"\u003eAlways verify inverter and system compatibility before installation.\u003c\/p\u003e\n\u003chr data-end=\"5075\" data-start=\"5072\"\u003e\n\u003ch2 data-end=\"5090\" data-start=\"5077\"\u003e🟢 Summary\u003c\/h2\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"5596\" data-start=\"5092\"\u003eThe \u003cstrong data-end=\"5118\" data-start=\"5096\"\u003eSolarEdge OP300-MV\u003c\/strong\u003e is a \u003cstrong data-end=\"5161\" data-start=\"5124\"\u003e300W photovoltaic power optimizer\u003c\/strong\u003e designed to maximize the performance of individual solar modules through advanced \u003cstrong data-end=\"5278\" data-start=\"5244\"\u003emodule-level MPPT optimization\u003c\/strong\u003e. Featuring a \u003cstrong data-end=\"5410\" data-start=\"5292\"\u003e5–75V input range, 10A maximum input current, IP65 protection, and compatibility with SolarEdge monitoring systems\u003c\/strong\u003e, it improves energy production, reduces shading and mismatch losses, and provides detailed module-level performance monitoring for residential and commercial photovoltaic installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pointer-events-none -mt-px h-px translate-y-[calc(var(--scroll-root-safe-area-inset-bottom)-14*var(--spacing))]\" aria-hidden=\"true\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":50280902459725,"sku":"","price":70.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6122.jpg?v=1781106404","url":"https:\/\/greenenergy-repair.com\/pl\/products\/solaredge-op300-mv-tycrm-4-300w-5-75v-10a-ottimizzatore-x-panelli-fotovoltaici","provider":"Green Energy","version":"1.0","type":"link"}