{"product_id":"sma-smc-sb-tripower-pv-invereter-grid-gate-11-cei-0-21","title":"SMA SMC SB TRIPOWER PV Invereter Grid Gate-11 CEI 0-21","description":"\u003cp\u003eNew \u003c\/p\u003e\n\u003ch2 data-start=\"201\" data-end=\"226\"\u003e1. Safety Instructions\u003c\/h2\u003e\n\u003col data-start=\"227\" data-end=\"808\"\u003e\n\u003cli data-start=\"227\" data-end=\"318\"\u003e\n\u003cp data-start=\"230\" data-end=\"318\"\u003e\u003cstrong data-start=\"230\" data-end=\"249\"\u003eRead Before Use\u003c\/strong\u003e: Carefully read all instructions before installation or operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"319\" data-end=\"438\"\u003e\n\u003cp data-start=\"322\" data-end=\"438\"\u003e\u003cstrong data-start=\"322\" data-end=\"350\"\u003eQualified Personnel Only\u003c\/strong\u003e: Installation, commissioning, and maintenance must be done by certified electricians.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"439\" data-end=\"548\"\u003e\n\u003cp data-start=\"442\" data-end=\"548\"\u003e\u003cstrong data-start=\"442\" data-end=\"469\"\u003eElectrical Shock Hazard\u003c\/strong\u003e: Disconnect AC and DC power before servicing. Avoid touching live terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"549\" data-end=\"617\"\u003e\n\u003cp data-start=\"552\" data-end=\"617\"\u003e\u003cstrong data-start=\"552\" data-end=\"565\"\u003eFire Risk\u003c\/strong\u003e: Keep the inverter away from flammable materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"618\" data-end=\"709\"\u003e\n\u003cp data-start=\"621\" data-end=\"709\"\u003e\u003cstrong data-start=\"621\" data-end=\"634\"\u003eGrounding\u003c\/strong\u003e: Connect the inverter to a proper ground according to local regulations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"710\" data-end=\"808\"\u003e\n\u003cp data-start=\"713\" data-end=\"808\"\u003e\u003cstrong data-start=\"713\" data-end=\"737\"\u003eProtective Equipment\u003c\/strong\u003e: Use insulated gloves and safety goggles when handling the inverter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"815\" data-end=\"837\"\u003e2. Product Overview\u003c\/h2\u003e\n\u003cul data-start=\"838\" data-end=\"1056\"\u003e\n\u003cli data-start=\"838\" data-end=\"872\"\u003e\n\u003cp data-start=\"840\" data-end=\"872\"\u003e\u003cstrong data-start=\"840\" data-end=\"849\"\u003eModel\u003c\/strong\u003e: SMA SMC SB Tripower\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"873\" data-end=\"920\"\u003e\n\u003cp data-start=\"875\" data-end=\"920\"\u003e\u003cstrong data-start=\"875\" data-end=\"883\"\u003eType\u003c\/strong\u003e: Three-phase photovoltaic inverter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"921\" data-end=\"948\"\u003e\n\u003cp data-start=\"923\" data-end=\"948\"\u003e\u003cstrong data-start=\"923\" data-end=\"939\"\u003eMax AC Power\u003c\/strong\u003e: 11 kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"949\" data-end=\"985\"\u003e\n\u003cp data-start=\"951\" data-end=\"985\"\u003e\u003cstrong data-start=\"951\" data-end=\"968\"\u003eInput Voltage\u003c\/strong\u003e: DC 150–1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"986\" data-end=\"1026\"\u003e\n\u003cp data-start=\"988\" data-end=\"1026\"\u003e\u003cstrong data-start=\"988\" data-end=\"1006\"\u003eOutput Voltage\u003c\/strong\u003e: AC 400 V \/ 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1056\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1056\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1043\"\u003eEfficiency\u003c\/strong\u003e: Up to 98%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1058\" data-end=\"1075\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1072\"\u003eComponents\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1076\" data-end=\"1273\"\u003e\n\u003cli data-start=\"1076\" data-end=\"1114\"\u003e\n\u003cp data-start=\"1078\" data-end=\"1114\"\u003eLCD display and navigation buttons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1153\"\u003e\n\u003cp data-start=\"1117\" data-end=\"1153\"\u003eDC input terminals (PV+) and (PV−)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1154\" data-end=\"1193\"\u003e\n\u003cp data-start=\"1156\" data-end=\"1193\"\u003eAC output terminals (L1, L2, L3, N)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1194\" data-end=\"1235\"\u003e\n\u003cp data-start=\"1196\" data-end=\"1235\"\u003eCommunication ports (RS485, Ethernet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1236\" data-end=\"1273\"\u003e\n\u003cp data-start=\"1238\" data-end=\"1273\"\u003eCooling fan and ventilation slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1280\" data-end=\"1311\"\u003e3. Installation Instructions\u003c\/h2\u003e\n\u003col data-start=\"1312\" data-end=\"1945\"\u003e\n\u003cli data-start=\"1312\" data-end=\"1439\"\u003e\n\u003cp data-start=\"1315\" data-end=\"1339\"\u003e\u003cstrong data-start=\"1315\" data-end=\"1336\"\u003eMounting Location\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1343\" data-end=\"1439\"\u003e\n\u003cli data-start=\"1343\" data-end=\"1380\"\u003e\n\u003cp data-start=\"1345\" data-end=\"1380\"\u003eIndoor or sheltered outdoor area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1384\" data-end=\"1439\"\u003e\n\u003cp data-start=\"1386\" data-end=\"1439\"\u003eEnsure adequate airflow (minimum 10 cm from walls).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1440\" data-end=\"1542\"\u003e\n\u003cp data-start=\"1443\" data-end=\"1458\"\u003e\u003cstrong data-start=\"1443\" data-end=\"1455\"\u003eMounting\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1462\" data-end=\"1542\"\u003e\n\u003cli data-start=\"1462\" data-end=\"1542\"\u003e\n\u003cp data-start=\"1464\" data-end=\"1542\"\u003eSecure the inverter on a wall or mounting frame using SMA-supplied brackets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1543\" data-end=\"1672\"\u003e\n\u003cp data-start=\"1546\" data-end=\"1573\"\u003e\u003cstrong data-start=\"1546\" data-end=\"1570\"\u003eDC Wiring (PV Input)\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1577\" data-end=\"1672\"\u003e\n\u003cli data-start=\"1577\" data-end=\"1640\"\u003e\n\u003cp data-start=\"1579\" data-end=\"1640\"\u003eConnect PV+ and PV− from the solar modules to the inverter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1644\" data-end=\"1672\"\u003e\n\u003cp data-start=\"1646\" data-end=\"1672\"\u003eVerify correct polarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1673\" data-end=\"1834\"\u003e\n\u003cp data-start=\"1676\" data-end=\"1710\"\u003e\u003cstrong data-start=\"1676\" data-end=\"1707\"\u003eAC Wiring (Grid Connection)\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1714\" data-end=\"1834\"\u003e\n\u003cli data-start=\"1714\" data-end=\"1773\"\u003e\n\u003cp data-start=\"1716\" data-end=\"1773\"\u003eConnect L1, L2, L3, and N to the AC distribution board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1777\" data-end=\"1834\"\u003e\n\u003cp data-start=\"1779\" data-end=\"1834\"\u003eInstall a dedicated circuit breaker for the inverter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1835\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1854\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1851\"\u003eGrounding\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1858\" data-end=\"1945\"\u003e\n\u003cli data-start=\"1858\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1860\" data-end=\"1945\"\u003eConnect the grounding terminal to the system ground according to CEI 0-21 standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"1952\" data-end=\"1971\"\u003e4. Commissioning\u003c\/h2\u003e\n\u003col data-start=\"1972\" data-end=\"2311\"\u003e\n\u003cli data-start=\"1972\" data-end=\"2003\"\u003e\n\u003cp data-start=\"1975\" data-end=\"2003\"\u003eSwitch on DC and AC power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2004\" data-end=\"2049\"\u003e\n\u003cp data-start=\"2007\" data-end=\"2049\"\u003eThe LCD will display the startup screen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2050\" data-end=\"2181\"\u003e\n\u003cp data-start=\"2053\" data-end=\"2092\"\u003eFollow the on-screen setup wizard to:\u003c\/p\u003e\n\u003cul data-start=\"2096\" data-end=\"2181\"\u003e\n\u003cli data-start=\"2096\" data-end=\"2115\"\u003e\n\u003cp data-start=\"2098\" data-end=\"2115\"\u003eSelect language\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2119\" data-end=\"2153\"\u003e\n\u003cp data-start=\"2121\" data-end=\"2153\"\u003eSet grid parameters (CEI 0-21)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2157\" data-end=\"2181\"\u003e\n\u003cp data-start=\"2159\" data-end=\"2181\"\u003eEnter PV system size\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2182\" data-end=\"2226\"\u003e\n\u003cp data-start=\"2185\" data-end=\"2226\"\u003eConfirm PV voltage and grid connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2227\" data-end=\"2311\"\u003e\n\u003cp data-start=\"2230\" data-end=\"2311\"\u003eVerify there are no error messages. The inverter will enter \u003cstrong data-start=\"2290\" data-end=\"2308\"\u003eOperation Mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2318\" data-end=\"2333\"\u003e5. Operation\u003c\/h2\u003e\n\u003cul data-start=\"2334\" data-end=\"2613\"\u003e\n\u003cli data-start=\"2334\" data-end=\"2430\"\u003e\n\u003cp data-start=\"2336\" data-end=\"2430\"\u003e\u003cstrong data-start=\"2336\" data-end=\"2351\"\u003eLCD Display\u003c\/strong\u003e: Shows real-time voltage, current, power, energy yield, and status messages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2431\" data-end=\"2525\"\u003e\n\u003cp data-start=\"2433\" data-end=\"2447\"\u003e\u003cstrong data-start=\"2433\" data-end=\"2444\"\u003eButtons\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"2450\" data-end=\"2525\"\u003e\n\u003cli data-start=\"2450\" data-end=\"2487\"\u003e\n\u003cp data-start=\"2452\" data-end=\"2487\"\u003e\u003cstrong data-start=\"2452\" data-end=\"2464\"\u003eEnter\/OK\u003c\/strong\u003e – confirm selections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2490\" data-end=\"2525\"\u003e\n\u003cp data-start=\"2492\" data-end=\"2525\"\u003e\u003cstrong data-start=\"2492\" data-end=\"2506\"\u003eArrow Keys\u003c\/strong\u003e – navigate menus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2526\" data-end=\"2613\"\u003e\n\u003cp data-start=\"2528\" data-end=\"2613\"\u003e\u003cstrong data-start=\"2528\" data-end=\"2548\"\u003eNormal Operation\u003c\/strong\u003e: Converts DC from PV modules to AC for the grid automatically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2620\" data-end=\"2637\"\u003e6. Maintenance\u003c\/h2\u003e\n\u003cul data-start=\"2638\" data-end=\"2871\"\u003e\n\u003cli data-start=\"2638\" data-end=\"2718\"\u003e\n\u003cp data-start=\"2640\" data-end=\"2718\"\u003e\u003cstrong data-start=\"2640\" data-end=\"2661\"\u003eVisual Inspection\u003c\/strong\u003e: Check monthly for dust, debris, or loose connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2719\" data-end=\"2793\"\u003e\n\u003cp data-start=\"2721\" data-end=\"2793\"\u003e\u003cstrong data-start=\"2721\" data-end=\"2733\"\u003eCleaning\u003c\/strong\u003e: Wipe with a dry cloth; avoid water or chemical solvents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2794\" data-end=\"2871\"\u003e\n\u003cp data-start=\"2796\" data-end=\"2871\"\u003e\u003cstrong data-start=\"2796\" data-end=\"2816\"\u003eFirmware Updates\u003c\/strong\u003e: Can be performed via SMA Sunny Portal or USB drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2878\" data-end=\"2899\"\u003e7. Troubleshooting\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2900\" data-end=\"3198\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2900\" data-end=\"2939\"\u003e\n\u003ctr data-start=\"2900\" data-end=\"2939\"\u003e\n\u003cth data-start=\"2900\" data-end=\"2910\" data-col-size=\"sm\" class=\"\"\u003eSymptom\u003c\/th\u003e\n\u003cth data-start=\"2910\" data-end=\"2927\" data-col-size=\"sm\" class=\"\"\u003ePossible Cause\u003c\/th\u003e\n\u003cth data-start=\"2927\" data-end=\"2939\" data-col-size=\"sm\" class=\"\"\u003eSolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2979\" data-end=\"3198\"\u003e\n\u003ctr data-start=\"2979\" data-end=\"3031\"\u003e\n\u003ctd data-start=\"2979\" data-end=\"2994\" data-col-size=\"sm\"\u003eNo AC output\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2994\" data-end=\"3009\"\u003eGrid failure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3009\" data-end=\"3031\"\u003eCheck grid voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3032\" data-end=\"3124\"\u003e\n\u003ctd data-start=\"3032\" data-end=\"3052\" data-col-size=\"sm\"\u003eError code on LCD\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3052\" data-end=\"3089\"\u003eOvervoltage, overload, or PV fault\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3089\" data-end=\"3124\"\u003eReduce PV input, reset inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3125\" data-end=\"3198\"\u003e\n\u003ctd data-start=\"3125\" data-end=\"3137\" data-col-size=\"sm\"\u003eLow power\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3137\" data-end=\"3161\"\u003eShading, dirty panels\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3161\" data-end=\"3198\"\u003eClean modules, adjust orientation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-start=\"3205\" data-end=\"3235\"\u003e8. Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3236\" data-end=\"3404\"\u003e\n\u003cli data-start=\"3236\" data-end=\"3266\"\u003e\n\u003cp data-start=\"3238\" data-end=\"3266\"\u003e\u003cstrong data-start=\"3238\" data-end=\"3256\"\u003eMax DC voltage\u003c\/strong\u003e: 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3267\" data-end=\"3304\"\u003e\n\u003cp data-start=\"3269\" data-end=\"3304\"\u003e\u003cstrong data-start=\"3269\" data-end=\"3291\"\u003eMPPT voltage range\u003c\/strong\u003e: 200–800 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3305\" data-end=\"3345\"\u003e\n\u003cp data-start=\"3307\" data-end=\"3345\"\u003e\u003cstrong data-start=\"3307\" data-end=\"3329\"\u003eNominal AC voltage\u003c\/strong\u003e: 400 V, 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3346\" data-end=\"3374\"\u003e\n\u003cp data-start=\"3348\" data-end=\"3374\"\u003e\u003cstrong data-start=\"3348\" data-end=\"3366\"\u003eMax AC current\u003c\/strong\u003e: 16 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3375\" data-end=\"3404\"\u003e\n\u003cp data-start=\"3377\" data-end=\"3404\"\u003e\u003cstrong data-start=\"3377\" data-end=\"3391\"\u003eEfficiency\u003c\/strong\u003e: up to 98%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3411\" data-end=\"3436\"\u003e9. Storage \u0026amp; Transport\u003c\/h2\u003e\n\u003cul data-start=\"3437\" data-end=\"3552\"\u003e\n\u003cli data-start=\"3437\" data-end=\"3473\"\u003e\n\u003cp data-start=\"3439\" data-end=\"3473\"\u003eStore in a dry, ventilated area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3474\" data-end=\"3513\"\u003e\n\u003cp data-start=\"3476\" data-end=\"3513\"\u003eProtect from shocks and vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3514\" data-end=\"3552\"\u003e\n\u003cp data-start=\"3516\" data-end=\"3552\"\u003eTemperature range: −25°C to +60°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":50170264224077,"sku":"","price":400.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/IMG20240910111134.jpg?v=1725958335","url":"https:\/\/greenenergy-repair.com\/pl\/products\/sma-smc-sb-tripower-pv-invereter-grid-gate-11-cei-0-21","provider":"Green Energy","version":"1.0","type":"link"}