{"product_id":"schneider-electric-prd-c40-1000-pv-type-2-surge-protection-device-1000-vdc-40-ka-3-pole-spd","title":"Schneider Electric PRD C40-1000 PV Type 2 Surge Protection Device | 1000 VDC | 40 kA | 3-Pole SPD","description":"\u003cp data-start=\"317\" data-end=\"628\"\u003eThe \u003cstrong data-start=\"321\" data-end=\"359\"\u003eSchneider Electric PRD C40-1000 PV\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"382\" data-end=\"427\"\u003eType 2 \/ Class II surge protection device\u003c\/strong\u003e designed specifically for \u003cstrong data-start=\"454\" data-end=\"481\"\u003ephotovoltaic DC systems\u003c\/strong\u003e. It protects PV strings, inverters, and DC distribution equipment against transient overvoltages caused by lightning strikes and switching surges.\u003c\/p\u003e\n\u003cp data-start=\"630\" data-end=\"916\"\u003eThis SPD supports \u003cstrong data-start=\"648\" data-end=\"667\"\u003eup to 1000 V DC\u003c\/strong\u003e and features a \u003cstrong data-start=\"683\" data-end=\"722\"\u003e3-pole configuration (L+ \/ PE \/ L−)\u003c\/strong\u003e, providing comprehensive protection for modern PV installations. With a high discharge capacity of \u003cstrong data-start=\"822\" data-end=\"841\"\u003e40 kA (8\/20 µs)\u003c\/strong\u003e per pole, it is suitable for commercial and industrial solar power plants.\u003c\/p\u003e\n\u003cp data-start=\"918\" data-end=\"1086\"\u003eManufactured by Schneider Electric to international standards, the PRD series ensures long-term reliability, modular serviceability, and clear visual status indication.\u003c\/p\u003e\n\u003cp data-start=\"1088\" data-end=\"1175\"\u003e🔄 \u003cstrong data-start=\"1091\" data-end=\"1105\"\u003eCondition:\u003c\/strong\u003e Used, fully functional\u003cbr data-start=\"1130\" data-end=\"1133\"\u003e🛠 \u003cstrong data-start=\"1136\" data-end=\"1149\"\u003eWarranty:\u003c\/strong\u003e 6 months by Green Energy\u003c\/p\u003e\n\u003ch3 data-start=\"1182\" data-end=\"1214\"\u003e⚙️ Technical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1218\" data-end=\"1256\"\u003e\n\u003cstrong data-start=\"1218\" data-end=\"1235\"\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli data-start=\"1259\" data-end=\"1276\"\u003e\n\u003cstrong data-start=\"1259\" data-end=\"1270\"\u003eSeries:\u003c\/strong\u003e PRD\u003c\/li\u003e\n\u003cli data-start=\"1279\" data-end=\"1303\"\u003e\n\u003cstrong data-start=\"1279\" data-end=\"1289\"\u003eModel:\u003c\/strong\u003e C40-1000 PV\u003c\/li\u003e\n\u003cli data-start=\"1306\" data-end=\"1344\"\u003e\n\u003cstrong data-start=\"1306\" data-end=\"1319\"\u003eSPD Type:\u003c\/strong\u003e Type 2 \/ Class II (T2)\u003c\/li\u003e\n\u003cli data-start=\"1347\" data-end=\"1385\"\u003e\n\u003cstrong data-start=\"1347\" data-end=\"1373\"\u003eMax PV Voltage (Ucpv):\u003c\/strong\u003e 1000 V DC\u003c\/li\u003e\n\u003cli data-start=\"1388\" data-end=\"1441\"\u003e\n\u003cstrong data-start=\"1388\" data-end=\"1423\"\u003eNominal Discharge Current (In):\u003c\/strong\u003e 15 kA (8\/20 µs)\u003c\/li\u003e\n\u003cli data-start=\"1444\" data-end=\"1499\"\u003e\n\u003cstrong data-start=\"1444\" data-end=\"1481\"\u003eMaximum Discharge Current (Imax):\u003c\/strong\u003e 40 kA (8\/20 µs)\u003c\/li\u003e\n\u003cli data-start=\"1502\" data-end=\"1539\"\u003e\n\u003cstrong data-start=\"1502\" data-end=\"1528\"\u003eProtection Level (Up):\u003c\/strong\u003e ≤ 1.9 kV\u003c\/li\u003e\n\u003cli data-start=\"1542\" data-end=\"1584\"\u003e\n\u003cstrong data-start=\"1542\" data-end=\"1560\"\u003eConfiguration:\u003c\/strong\u003e 3-pole (L+ \/ PE \/ L−)\u003c\/li\u003e\n\u003cli data-start=\"1587\" data-end=\"1617\"\u003e\n\u003cstrong data-start=\"1587\" data-end=\"1610\"\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli data-start=\"1620\" data-end=\"1644\"\u003e\n\u003cstrong data-start=\"1620\" data-end=\"1633\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1694\"\u003e\n\u003cstrong data-start=\"1647\" data-end=\"1661\"\u003eStandards:\u003c\/strong\u003e IEC \/ EN 61740-51, EN 50539-11\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1752\"\u003e\n\u003cstrong data-start=\"1697\" data-end=\"1719\"\u003eStatus Indication:\u003c\/strong\u003e Visual indicator (Red = Replace)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1759\" data-end=\"1779\"\u003e📌 Key Features:\u003c\/h3\u003e\n\u003cp data-start=\"1781\" data-end=\"2059\"\u003e✔️ Original Schneider Electric PV surge protection device\u003cbr data-start=\"1838\" data-end=\"1841\"\u003e✔️ Designed for DC side of solar PV systems\u003cbr data-start=\"1884\" data-end=\"1887\"\u003e✔️ High discharge capacity for lightning and surge protection\u003cbr data-start=\"1948\" data-end=\"1951\"\u003e✔️ Modular plug-in design for easy replacement\u003cbr data-start=\"1997\" data-end=\"2000\"\u003e✔️ Ideal for string combiner boxes and inverter DC inputs\u003c\/p\u003e\n\u003cp data-start=\"2066\" data-end=\"2241\"\u003e🚀 \u003cstrong data-start=\"2069\" data-end=\"2241\"\u003eProtect your photovoltaic installation from damaging DC surges with this Schneider Electric PRD C40-1000 PV SPD — tested, reliable, and backed by Green Energy warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53185365115213,"sku":null,"price":45.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/IMG20260115101523_efb0d28a-af54-4c31-a423-4910162f112e.jpg?v=1768479591","url":"https:\/\/greenenergy-repair.com\/pl\/products\/schneider-electric-prd-c40-1000-pv-type-2-surge-protection-device-1000-vdc-40-ka-3-pole-spd","provider":"Green Energy","version":"1.0","type":"link"}