{"product_id":"moeller-nzm1-a125-mccb-adjustable-trip-unit-125a-690v-ac-dc-cat-a-iec-60947-made-in-germany-used-copy","title":"Moeller NZM1 Circuit Breaker | 3-Pole | 125 A | 690 V AC | Trip Unit NZM B1-A125 | Made in Romania","description":"\u003cp data-end=\"822\" data-start=\"457\"\u003eThe \u003cstrong data-end=\"477\" data-start=\"461\"\u003eMoeller NZM1\u003c\/strong\u003e is a 3-pole molded case circuit breaker (MCCB) engineered for reliable protection of electrical systems in industrial and solar power installations.\u003cbr data-end=\"629\" data-start=\"626\"\u003eEquipped with the \u003cstrong data-end=\"700\" data-start=\"647\"\u003eNZM B1-A125 adjustable thermal-magnetic trip unit\u003c\/strong\u003e, it provides precise overcurrent and short-circuit protection up to \u003cstrong data-end=\"778\" data-start=\"769\"\u003e125 A\u003c\/strong\u003e at operating voltages up to \u003cstrong data-end=\"819\" data-start=\"807\"\u003e690 V AC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1015\" data-start=\"824\"\u003eThis breaker meets international safety standards (IEC\/EN 60947-2, DIN-VDE 0660) and is ideal for AC power distribution panels, inverter protection circuits, and heavy-duty control systems.\u003c\/p\u003e\n\u003cp data-end=\"1108\" data-start=\"1017\"\u003e🔄 \u003cstrong data-end=\"1034\" data-start=\"1020\"\u003eCondition:\u003c\/strong\u003e Used\u003cbr data-end=\"1064\" data-start=\"1061\"\u003e🛠 \u003cstrong data-end=\"1080\" data-start=\"1067\"\u003eWarranty:\u003c\/strong\u003e 6 months by Green Energy\u003c\/p\u003e\n\u003cp data-end=\"1149\" data-start=\"1115\"\u003e⚙️ \u003cstrong data-end=\"1147\" data-start=\"1118\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"1196\" data-start=\"1152\"\u003e\n\u003cstrong data-end=\"1162\" data-start=\"1152\"\u003eModel:\u003c\/strong\u003e NZM1 with NZM B1-A125 Trip Unit\u003c\/li\u003e\n\u003cli data-end=\"1230\" data-start=\"1199\"\u003e\n\u003cstrong data-end=\"1222\" data-start=\"1199\"\u003eRated Current (In):\u003c\/strong\u003e 125 A\u003c\/li\u003e\n\u003cli data-end=\"1252\" data-start=\"1233\"\u003e\n\u003cstrong data-end=\"1243\" data-start=\"1233\"\u003ePoles:\u003c\/strong\u003e 3-pole\u003c\/li\u003e\n\u003cli data-end=\"1295\" data-start=\"1255\"\u003e\n\u003cstrong data-end=\"1278\" data-start=\"1255\"\u003eRated Voltage (Ue):\u003c\/strong\u003e up to 690 V AC\u003c\/li\u003e\n\u003cli data-end=\"1340\" data-start=\"1298\"\u003e\n\u003cstrong data-end=\"1332\" data-start=\"1298\"\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e 690 V\u003c\/li\u003e\n\u003cli data-end=\"1387\" data-start=\"1343\"\u003e\n\u003cstrong data-end=\"1380\" data-start=\"1343\"\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003cli data-end=\"1458\" data-start=\"1390\"\u003e\n\u003cstrong data-end=\"1418\" data-start=\"1390\"\u003eBreaking Capacity (Icu):\u003c\/strong\u003e up to 30 kA at 230 V \/ 25 kA at 400 V\u003c\/li\u003e\n\u003cli data-end=\"1486\" data-start=\"1461\"\u003e\n\u003cstrong data-end=\"1475\" data-start=\"1461\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-end=\"1544\" data-start=\"1489\"\u003e\n\u003cstrong data-end=\"1513\" data-start=\"1489\"\u003eStandard Compliance:\u003c\/strong\u003e IEC\/EN 60947-2, DIN-VDE 0660\u003c\/li\u003e\n\u003cli data-end=\"1579\" data-start=\"1547\"\u003e\n\u003cstrong data-end=\"1569\" data-start=\"1547\"\u003eCountry of Origin:\u003c\/strong\u003e Romania\u003c\/li\u003e\n\u003cli data-end=\"1630\" data-start=\"1582\"\u003e\n\u003cstrong data-end=\"1600\" data-start=\"1582\"\u003eMounting Type:\u003c\/strong\u003e Panel \/ DIN-rail compatible\u003c\/li\u003e\n\u003cli data-end=\"1674\" data-start=\"1633\"\u003e\n\u003cstrong data-end=\"1650\" data-start=\"1633\"\u003eManufacturer:\u003c\/strong\u003e Moeller (Eaton Group)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1970\" data-start=\"1681\"\u003e📌 \u003cstrong data-end=\"1701\" data-start=\"1684\"\u003eKey Features:\u003c\/strong\u003e\u003cbr data-end=\"1704\" data-start=\"1701\"\u003e✔️ High-reliability molded case circuit breaker\u003cbr data-end=\"1754\" data-start=\"1751\"\u003e✔️ Adjustable thermal-magnetic trip settings\u003cbr data-end=\"1801\" data-start=\"1798\"\u003e✔️ Rated for demanding industrial and PV inverter applications\u003cbr data-end=\"1866\" data-start=\"1863\"\u003e✔️ Compact 3-pole construction for easy integration\u003cbr data-end=\"1920\" data-start=\"1917\"\u003e✔️ Certified per IEC\/EN 60947-2 safety standards\u003c\/p\u003e\n\u003cp data-end=\"2155\" data-start=\"1977\"\u003e🚀 \u003cstrong data-end=\"2155\" data-start=\"1980\"\u003eEnsure safe and efficient operation of your industrial or solar power system with the original Moeller NZM1 circuit breaker — tested, verified, and backed by Green Energy.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Moeller circuit breaker","offers":[{"title":"Default Title","offer_id":52663751049549,"sku":null,"price":80.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/rn-image_picker_lib_temp_f0f0c836-f6b5-43bb-9764-de39ab10a852.jpg?v=1761653861","url":"https:\/\/greenenergy-repair.com\/pl\/products\/moeller-nzm1-a125-mccb-adjustable-trip-unit-125a-690v-ac-dc-cat-a-iec-60947-made-in-germany-used-copy","provider":"Green Energy","version":"1.0","type":"link"}