{"product_id":"italweber-bch-3x38-32a-400-690v-2303038-16f5-50-60hz-ggmax-3w-am-max-1-2w","title":"Italweber BCH 3x38 – 3P Modular Fuse Holder for 10×38 mm Fuses | 32A | 690V AC","description":"\u003cp data-start=\"183\" data-end=\"461\"\u003eThe \u003cstrong data-start=\"187\" data-end=\"209\"\u003eItalweber BCH 3x38\u003c\/strong\u003e is a \u003cstrong data-start=\"215\" data-end=\"250\"\u003ethree-phase modular fuse holder\u003c\/strong\u003e designed to accommodate \u003cstrong data-start=\"275\" data-end=\"310\"\u003e10×38 mm cylindrical fuse links\u003c\/strong\u003e. This device is intended for protecting electrical circuits in both \u003cstrong data-start=\"379\" data-end=\"423\"\u003eindustrial and residential installations\u003c\/strong\u003e against overloads and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"463\" data-end=\"721\"\u003eThe unit allows the installation of \u003cstrong data-start=\"499\" data-end=\"523\"\u003ethree 10×38 mm fuses\u003c\/strong\u003e, one for each phase, ensuring effective protection of three-phase electrical lines. It is designed for \u003cstrong data-start=\"627\" data-end=\"657\"\u003estandard DIN rail mounting\u003c\/strong\u003e, making it compatible with most electrical distribution panels.\u003c\/p\u003e\n\u003cp data-start=\"723\" data-end=\"1003\"\u003eThanks to its \u003cstrong data-start=\"737\" data-end=\"798\"\u003erobust construction and high-quality insulating materials\u003c\/strong\u003e, the fuse holder ensures high operational reliability and safety. The \u003cstrong data-start=\"869\" data-end=\"896\"\u003efront-opening mechanism\u003c\/strong\u003e allows quick and safe replacement of the fuse links without removing the device from the electrical panel.\u003c\/p\u003e\n\u003cp data-start=\"1005\" data-end=\"1220\"\u003eThe product complies with major \u003cstrong data-start=\"1037\" data-end=\"1098\"\u003einternational standards for electrical protection devices\u003c\/strong\u003e, making it suitable for industrial applications, distribution boards, photovoltaic systems, and automation installations.\u003c\/p\u003e\n\u003chr data-start=\"1222\" data-end=\"1225\"\u003e\n\u003ch2 data-start=\"1227\" data-end=\"1259\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1261\" data-end=\"1353\"\u003e\u003cstrong data-start=\"1261\" data-end=\"1271\"\u003eBrand:\u003c\/strong\u003e Italweber\u003cbr data-start=\"1281\" data-end=\"1284\"\u003e\u003cstrong data-start=\"1284\" data-end=\"1295\"\u003eSeries:\u003c\/strong\u003e BCH\u003cbr data-start=\"1299\" data-end=\"1302\"\u003e\u003cstrong data-start=\"1302\" data-end=\"1312\"\u003eModel:\u003c\/strong\u003e BCH 3x38\u003cbr data-start=\"1321\" data-end=\"1324\"\u003e\u003cstrong data-start=\"1324\" data-end=\"1341\"\u003eProduct code:\u003c\/strong\u003e \u003cstrong data-start=\"1342\" data-end=\"1353\"\u003e2303038\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1355\" data-end=\"1385\"\u003e🔌 Electrical Parameters\u003c\/h3\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1428\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1428\"\u003eFuse type: \u003cstrong data-start=\"1400\" data-end=\"1426\"\u003eCylindrical 10 × 38 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1429\" data-end=\"1456\"\u003e\n\u003cp data-start=\"1431\" data-end=\"1456\"\u003eRated current: \u003cstrong data-start=\"1446\" data-end=\"1454\"\u003e32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1457\" data-end=\"1488\"\u003e\n\u003cp data-start=\"1459\" data-end=\"1488\"\u003eRated voltage: \u003cstrong data-start=\"1474\" data-end=\"1486\"\u003e690 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1489\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1491\" data-end=\"1516\"\u003eFrequency: \u003cstrong data-start=\"1502\" data-end=\"1516\"\u003e50 \/ 60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1518\" data-end=\"1536\"\u003e📜 Standards\u003c\/h3\u003e\n\u003cul data-start=\"1538\" data-end=\"1577\"\u003e\n\u003cli data-start=\"1538\" data-end=\"1557\"\u003e\n\u003cp data-start=\"1540\" data-end=\"1557\"\u003e\u003cstrong data-start=\"1540\" data-end=\"1555\"\u003eIEC 60947-3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1558\" data-end=\"1577\"\u003e\n\u003cp data-start=\"1560\" data-end=\"1577\"\u003e\u003cstrong data-start=\"1560\" data-end=\"1577\"\u003eIEC 60269-2-1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1579\" data-end=\"1606\"\u003e🔧 Fuse Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"1608\" data-end=\"1740\"\u003e\n\u003cli data-start=\"1608\" data-end=\"1653\"\u003e\n\u003cp data-start=\"1610\" data-end=\"1653\"\u003e\u003cstrong data-start=\"1610\" data-end=\"1616\"\u003egG\u003c\/strong\u003e (general protection) – max \u003cstrong data-start=\"1644\" data-end=\"1651\"\u003e3 W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1699\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1699\"\u003e\u003cstrong data-start=\"1656\" data-end=\"1662\"\u003eaM\u003c\/strong\u003e (motor protection) – max \u003cstrong data-start=\"1688\" data-end=\"1697\"\u003e1.2 W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1700\" data-end=\"1740\"\u003e\n\u003cp data-start=\"1702\" data-end=\"1740\"\u003e\u003cstrong data-start=\"1702\" data-end=\"1713\"\u003eaR \/ gR\u003c\/strong\u003e (semiconductor protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1742\" data-end=\"1745\"\u003e\n\u003ch2 data-start=\"1747\" data-end=\"1766\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003cul data-start=\"1768\" data-end=\"1863\"\u003e\n\u003cli data-start=\"1768\" data-end=\"1814\"\u003e\n\u003cp data-start=\"1770\" data-end=\"1814\"\u003eConductor cross-section: \u003cstrong data-start=\"1795\" data-end=\"1812\"\u003e0.75 – 25 mm²\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1815\" data-end=\"1863\"\u003e\n\u003cp data-start=\"1817\" data-end=\"1863\"\u003eTerminal tightening torque: approx. \u003cstrong data-start=\"1853\" data-end=\"1863\"\u003e2.5 Nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1865\" data-end=\"1868\"\u003e\n\u003ch2 data-start=\"1870\" data-end=\"1890\"\u003e🔧 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1892\" data-end=\"2014\"\u003e\n\u003cli data-start=\"1892\" data-end=\"1935\"\u003e\n\u003cp data-start=\"1894\" data-end=\"1935\"\u003eMounting on \u003cstrong data-start=\"1906\" data-end=\"1933\"\u003estandard 35 mm DIN rail\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1936\" data-end=\"1969\"\u003e\n\u003cp data-start=\"1938\" data-end=\"1969\"\u003e\u003cstrong data-start=\"1938\" data-end=\"1967\"\u003eThree-phase configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1970\" data-end=\"2014\"\u003e\n\u003cp data-start=\"1972\" data-end=\"2014\"\u003e\u003cstrong data-start=\"1972\" data-end=\"1988\"\u003eFront access\u003c\/strong\u003e for easy fuse replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":50167302422861,"sku":"","price":20.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4953.jpg?v=1772720931","url":"https:\/\/greenenergy-repair.com\/pl\/products\/italweber-bch-3x38-32a-400-690v-2303038-16f5-50-60hz-ggmax-3w-am-max-1-2w","provider":"Green Energy","version":"1.0","type":"link"}