{"product_id":"fronius-ig-plus-35v-1-3500va-4-210-015-3150w-230vac-fully-working","title":"Fronius IG Plus 35v-1 3500va 4.210.015 3150W 230VAC","description":"\u003cp\u003eUsed. Green Energy company gives a 12 month guarantee \u003ca href=\"https:\/\/solarparts.eu\/pages\/faq\"\u003eFAQ \u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"333\" data-end=\"355\"\u003e1. \u003cstrong data-start=\"339\" data-end=\"355\"\u003eIntroduction\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"356\" data-end=\"587\"\u003eThe \u003cstrong data-start=\"360\" data-end=\"385\"\u003eFronius IG Plus 35v‑1\u003c\/strong\u003e is a \u003cstrong data-start=\"391\" data-end=\"444\"\u003esingle-phase grid-connected photovoltaic inverter\u003c\/strong\u003e. It converts DC power from solar panels into AC power suitable for the grid, while monitoring performance and providing protection features.\u003c\/p\u003e\n\u003cp data-start=\"589\" data-end=\"702\"\u003e\u003cstrong data-start=\"589\" data-end=\"599\"\u003eModel:\u003c\/strong\u003e 4.210.015\u003cbr data-start=\"609\" data-end=\"612\"\u003e\u003cstrong data-start=\"612\" data-end=\"623\"\u003eOutput:\u003c\/strong\u003e 3150 W\u003cbr data-start=\"630\" data-end=\"633\"\u003e\u003cstrong data-start=\"633\" data-end=\"651\"\u003eRated Voltage:\u003c\/strong\u003e 230 VAC, 50\/60 Hz\u003cbr data-start=\"669\" data-end=\"672\"\u003e\u003cstrong data-start=\"672\" data-end=\"681\"\u003eType:\u003c\/strong\u003e Grid-tied inverter\u003c\/p\u003e\n\u003ch2 data-start=\"709\" data-end=\"738\"\u003e2. \u003cstrong data-start=\"715\" data-end=\"738\"\u003eSafety Instructions\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"739\" data-end=\"795\"\u003e⚠️ \u003cstrong data-start=\"742\" data-end=\"795\"\u003eImportant – Read Before Installation or Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-start=\"797\" data-end=\"1173\"\u003e\n\u003cli data-start=\"797\" data-end=\"874\"\u003e\n\u003cp data-start=\"800\" data-end=\"874\"\u003eOnly \u003cstrong data-start=\"805\" data-end=\"831\"\u003equalified electricians\u003c\/strong\u003e should install and operate the inverter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"875\" data-end=\"956\"\u003e\n\u003cp data-start=\"878\" data-end=\"956\"\u003eDisconnect the inverter from \u003cstrong data-start=\"907\" data-end=\"926\"\u003eAC and DC power\u003c\/strong\u003e before performing any work.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"1033\"\u003e\n\u003cp data-start=\"960\" data-end=\"1033\"\u003eEnsure proper \u003cstrong data-start=\"974\" data-end=\"999\"\u003egrounding and bonding\u003c\/strong\u003e according to local regulations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1034\" data-end=\"1094\"\u003e\n\u003cp data-start=\"1037\" data-end=\"1094\"\u003eAvoid exposure to water, dust, or extreme temperatures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1095\" data-end=\"1173\"\u003e\n\u003cp data-start=\"1098\" data-end=\"1173\"\u003eDo not open the inverter; there are \u003cstrong data-start=\"1134\" data-end=\"1163\"\u003eno user-serviceable parts\u003c\/strong\u003e inside.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"1180\" data-end=\"1206\"\u003e3. \u003cstrong data-start=\"1186\" data-end=\"1206\"\u003ePackage Contents\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"1207\" data-end=\"1411\"\u003e\n\u003cli data-start=\"1207\" data-end=\"1241\"\u003e\n\u003cp data-start=\"1209\" data-end=\"1241\"\u003eFronius IG Plus 35v‑1 inverter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1283\"\u003e\n\u003cp data-start=\"1244\" data-end=\"1283\"\u003eAC connection cable \/ terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1284\" data-end=\"1316\"\u003e\n\u003cp data-start=\"1286\" data-end=\"1316\"\u003eMounting brackets and screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1317\" data-end=\"1360\"\u003e\n\u003cp data-start=\"1319\" data-end=\"1360\"\u003eQuick Start Guide \/ Safety Instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1361\" data-end=\"1411\"\u003e\n\u003cp data-start=\"1363\" data-end=\"1411\"\u003eOptional: Fronius IG Com Card (for monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1418\" data-end=\"1443\"\u003e4. \u003cstrong data-start=\"1424\" data-end=\"1443\"\u003eDevice Overview\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"1444\" data-end=\"1828\"\u003e\n\u003cli data-start=\"1444\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1446\" data-end=\"1536\"\u003e\u003cstrong data-start=\"1446\" data-end=\"1459\"\u003eDC Input:\u003c\/strong\u003e Connects to solar PV array (max voltage and current as per specification).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1537\" data-end=\"1593\"\u003e\n\u003cp data-start=\"1539\" data-end=\"1593\"\u003e\u003cstrong data-start=\"1539\" data-end=\"1553\"\u003eAC Output:\u003c\/strong\u003e Single-phase 230 VAC grid connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1594\" data-end=\"1729\"\u003e\n\u003cp data-start=\"1596\" data-end=\"1617\"\u003e\u003cstrong data-start=\"1596\" data-end=\"1615\"\u003eLED Indicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1620\" data-end=\"1729\"\u003e\n\u003cli data-start=\"1620\" data-end=\"1651\"\u003e\n\u003cp data-start=\"1622\" data-end=\"1651\"\u003e\u003cstrong data-start=\"1622\" data-end=\"1632\"\u003eGreen:\u003c\/strong\u003e Normal operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1700\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1700\"\u003e\u003cstrong data-start=\"1656\" data-end=\"1667\"\u003eYellow:\u003c\/strong\u003e Warning \/ inverter starting up\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"1729\"\u003e\n\u003cp data-start=\"1705\" data-end=\"1729\"\u003e\u003cstrong data-start=\"1705\" data-end=\"1713\"\u003eRed:\u003c\/strong\u003e Fault \/ error\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1730\" data-end=\"1828\"\u003e\n\u003cp data-start=\"1732\" data-end=\"1828\"\u003e\u003cstrong data-start=\"1732\" data-end=\"1761\"\u003eCommunication Interfaces:\u003c\/strong\u003e Optional COM card for data logging, monitoring via PC or network\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1835\" data-end=\"1857\"\u003e5. \u003cstrong data-start=\"1841\" data-end=\"1857\"\u003eInstallation\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003col data-start=\"1858\" data-end=\"2651\"\u003e\n\u003cli data-start=\"1858\" data-end=\"2026\"\u003e\n\u003cp data-start=\"1861\" data-end=\"1894\"\u003e\u003cstrong data-start=\"1861\" data-end=\"1892\"\u003eSelect a suitable location:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1898\" data-end=\"2026\"\u003e\n\u003cli data-start=\"1898\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1900\" data-end=\"1925\"\u003eIndoor, dry, ventilated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1929\" data-end=\"1964\"\u003e\n\u003cp data-start=\"1931\" data-end=\"1964\"\u003eMax ambient temperature: +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1968\" data-end=\"2026\"\u003e\n\u003cp data-start=\"1970\" data-end=\"2026\"\u003eAvoid direct sunlight, dust, or corrosive environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2028\" data-end=\"2176\"\u003e\n\u003cp data-start=\"2031\" data-end=\"2059\"\u003e\u003cstrong data-start=\"2031\" data-end=\"2057\"\u003eMounting the inverter:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2063\" data-end=\"2176\"\u003e\n\u003cli data-start=\"2063\" data-end=\"2099\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2099\"\u003eUse supplied brackets and screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2103\" data-end=\"2134\"\u003e\n\u003cp data-start=\"2105\" data-end=\"2134\"\u003eEnsure vertical orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2138\" data-end=\"2176\"\u003e\n\u003cp data-start=\"2140\" data-end=\"2176\"\u003eMaintain clearance for ventilation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2178\" data-end=\"2423\"\u003e\n\u003cp data-start=\"2181\" data-end=\"2210\"\u003e\u003cstrong data-start=\"2181\" data-end=\"2208\"\u003eElectrical connections:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2214\" data-end=\"2423\"\u003e\n\u003cli data-start=\"2214\" data-end=\"2276\"\u003e\n\u003cp data-start=\"2216\" data-end=\"2276\"\u003e\u003cstrong data-start=\"2216\" data-end=\"2229\"\u003eDC input:\u003c\/strong\u003e Connect PV array (+\/−) to inverter terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2280\" data-end=\"2356\"\u003e\n\u003cp data-start=\"2282\" data-end=\"2356\"\u003e\u003cstrong data-start=\"2282\" data-end=\"2296\"\u003eAC output:\u003c\/strong\u003e Connect to grid via a dedicated circuit breaker (230 VAC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2360\" data-end=\"2423\"\u003e\n\u003cp data-start=\"2362\" data-end=\"2423\"\u003e\u003cstrong data-start=\"2362\" data-end=\"2376\"\u003eGrounding:\u003c\/strong\u003e Connect inverter grounding terminal to earth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2425\" data-end=\"2534\"\u003e\n\u003cp data-start=\"2428\" data-end=\"2452\"\u003e\u003cstrong data-start=\"2428\" data-end=\"2450\"\u003eOptional COM card:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2456\" data-end=\"2534\"\u003e\n\u003cli data-start=\"2456\" data-end=\"2534\"\u003e\n\u003cp data-start=\"2458\" data-end=\"2534\"\u003eInstall for data logging and monitoring (connects to PC via RS‑232 or USB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2536\" data-end=\"2651\"\u003e\n\u003cp data-start=\"2539\" data-end=\"2554\"\u003e\u003cstrong data-start=\"2539\" data-end=\"2552\"\u003ePower up:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2558\" data-end=\"2651\"\u003e\n\u003cli data-start=\"2558\" data-end=\"2588\"\u003e\n\u003cp data-start=\"2560\" data-end=\"2588\"\u003eSwitch on DC and AC supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2592\" data-end=\"2651\"\u003e\n\u003cp data-start=\"2594\" data-end=\"2651\"\u003eInverter performs self-test and begins feeding the grid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2658\" data-end=\"2677\"\u003e6. \u003cstrong data-start=\"2664\" data-end=\"2677\"\u003eOperation\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3 data-start=\"2678\" data-end=\"2702\"\u003e6.1 Normal Operation\u003c\/h3\u003e\n\u003cul data-start=\"2703\" data-end=\"2984\"\u003e\n\u003cli data-start=\"2703\" data-end=\"2788\"\u003e\n\u003cp data-start=\"2705\" data-end=\"2788\"\u003e\u003cstrong data-start=\"2705\" data-end=\"2718\"\u003eGreen LED\u003c\/strong\u003e indicates the inverter is operating correctly and feeding the grid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2789\" data-end=\"2984\"\u003e\n\u003cp data-start=\"2791\" data-end=\"2874\"\u003e\u003cstrong data-start=\"2791\" data-end=\"2818\"\u003ePerformance monitoring:\u003c\/strong\u003e Using COM card and Fronius monitoring software, view:\u003c\/p\u003e\n\u003cul data-start=\"2877\" data-end=\"2984\"\u003e\n\u003cli data-start=\"2877\" data-end=\"2904\"\u003e\n\u003cp data-start=\"2879\" data-end=\"2904\"\u003eEnergy production (kWh)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2907\" data-end=\"2936\"\u003e\n\u003cp data-start=\"2909\" data-end=\"2936\"\u003eAC and DC voltage\/current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2939\" data-end=\"2959\"\u003e\n\u003cp data-start=\"2941\" data-end=\"2959\"\u003ePower output (W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2962\" data-end=\"2984\"\u003e\n\u003cp data-start=\"2964\" data-end=\"2984\"\u003eOperational status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2986\" data-end=\"3001\"\u003e6.2 Startup\u003c\/h3\u003e\n\u003cul data-start=\"3002\" data-end=\"3137\"\u003e\n\u003cli data-start=\"3002\" data-end=\"3092\"\u003e\n\u003cp data-start=\"3004\" data-end=\"3092\"\u003eInverter starts automatically when DC voltage from PV array exceeds startup threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3093\" data-end=\"3137\"\u003e\n\u003cp data-start=\"3095\" data-end=\"3137\"\u003eWarm-up delay: ~30 seconds to 2 minutes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3139\" data-end=\"3155\"\u003e6.3 Shutdown\u003c\/h3\u003e\n\u003cul data-start=\"3156\" data-end=\"3233\"\u003e\n\u003cli data-start=\"3156\" data-end=\"3190\"\u003e\n\u003cp data-start=\"3158\" data-end=\"3190\"\u003eSwitch off AC and\/or DC supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3191\" data-end=\"3233\"\u003e\n\u003cp data-start=\"3193\" data-end=\"3233\"\u003eDisconnect inverter before maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3240\" data-end=\"3261\"\u003e7. \u003cstrong data-start=\"3246\" data-end=\"3261\"\u003eMaintenance\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"3262\" data-end=\"3479\"\u003e\n\u003cli data-start=\"3262\" data-end=\"3321\"\u003e\n\u003cp data-start=\"3264\" data-end=\"3321\"\u003eClean exterior with dry cloth; avoid water or solvents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3322\" data-end=\"3365\"\u003e\n\u003cp data-start=\"3324\" data-end=\"3365\"\u003eInspect cables and terminals regularly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3366\" data-end=\"3412\"\u003e\n\u003cp data-start=\"3368\" data-end=\"3412\"\u003eCheck LED indicators for normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3413\" data-end=\"3479\"\u003e\n\u003cp data-start=\"3415\" data-end=\"3479\"\u003eFaulty inverters must be serviced by \u003cstrong data-start=\"3452\" data-end=\"3476\"\u003eauthorized personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3486\" data-end=\"3511\"\u003e8. \u003cstrong data-start=\"3492\" data-end=\"3511\"\u003eTroubleshooting\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3512\" data-end=\"3851\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3512\" data-end=\"3567\"\u003e\n\u003ctr data-start=\"3512\" data-end=\"3567\"\u003e\n\u003cth data-start=\"3512\" data-end=\"3528\" data-col-size=\"sm\" class=\"\"\u003eLED \/ Symptom\u003c\/th\u003e\n\u003cth data-start=\"3528\" data-end=\"3545\" data-col-size=\"sm\" class=\"\"\u003ePossible Cause\u003c\/th\u003e\n\u003cth data-start=\"3545\" data-end=\"3567\" data-col-size=\"md\" class=\"\"\u003eRecommended Action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3622\" data-end=\"3851\"\u003e\n\u003ctr data-start=\"3622\" data-end=\"3713\"\u003e\n\u003ctd data-start=\"3622\" data-end=\"3635\" data-col-size=\"sm\"\u003eRed LED on\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3635\" data-end=\"3667\"\u003eDC overvoltage \/ undervoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3667\" data-end=\"3713\"\u003eCheck PV array voltage and inverter limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3714\" data-end=\"3788\"\u003e\n\u003ctd data-start=\"3714\" data-end=\"3727\" data-col-size=\"sm\"\u003eYellow LED\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3727\" data-end=\"3747\"\u003eGrid not detected\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3747\" data-end=\"3788\"\u003eVerify AC connection and grid voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3789\" data-end=\"3851\"\u003e\n\u003ctd data-start=\"3789\" data-end=\"3799\" data-col-size=\"sm\"\u003eNo LEDs\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3799\" data-end=\"3810\"\u003eNo power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3810\" data-end=\"3851\"\u003eCheck AC and DC supply, fuses, wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-start=\"3858\" data-end=\"3892\"\u003e9. \u003cstrong data-start=\"3864\" data-end=\"3892\"\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"3893\" data-end=\"4123\"\u003e\n\u003cli data-start=\"3893\" data-end=\"3931\"\u003e\n\u003cp data-start=\"3895\" data-end=\"3931\"\u003eRated AC output: 230 VAC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3932\" data-end=\"3964\"\u003e\n\u003cp data-start=\"3934\" data-end=\"3964\"\u003eMaximum output power: 3150 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3965\" data-end=\"3997\"\u003e\n\u003cp data-start=\"3967\" data-end=\"3997\"\u003eMaximum DC voltage: 500 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3998\" data-end=\"4032\"\u003e\n\u003cp data-start=\"4000\" data-end=\"4032\"\u003eMaximum DC input current: 15 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4033\" data-end=\"4053\"\u003e\n\u003cp data-start=\"4035\" data-end=\"4053\"\u003eEfficiency: ~95%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4054\" data-end=\"4096\"\u003e\n\u003cp data-start=\"4056\" data-end=\"4096\"\u003eOperating temperature: −25 °C … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4097\" data-end=\"4123\"\u003e\n\u003cp data-start=\"4099\" data-end=\"4123\"\u003eProtection class: IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4130\" data-end=\"4162\"\u003e10. \u003cstrong data-start=\"4137\" data-end=\"4162\"\u003eMonitoring (Optional)\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"4163\" data-end=\"4368\"\u003e\n\u003cli data-start=\"4163\" data-end=\"4220\"\u003e\n\u003cp data-start=\"4165\" data-end=\"4220\"\u003eInstall \u003cstrong data-start=\"4173\" data-end=\"4185\"\u003eCOM card\u003c\/strong\u003e for monitoring and data logging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4221\" data-end=\"4257\"\u003e\n\u003cp data-start=\"4223\" data-end=\"4257\"\u003eConnect to PC via RS‑232 or USB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4258\" data-end=\"4368\"\u003e\n\u003cp data-start=\"4260\" data-end=\"4305\"\u003eUse \u003cstrong data-start=\"4264\" data-end=\"4285\"\u003eFronius IG.access\u003c\/strong\u003e software to view:\u003c\/p\u003e\n\u003cul data-start=\"4308\" data-end=\"4368\"\u003e\n\u003cli data-start=\"4308\" data-end=\"4329\"\u003e\n\u003cp data-start=\"4310\" data-end=\"4329\"\u003eEnergy production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4332\" data-end=\"4351\"\u003e\n\u003cp data-start=\"4334\" data-end=\"4351\"\u003eHistorical data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4354\" data-end=\"4368\"\u003e\n\u003cp data-start=\"4356\" data-end=\"4368\"\u003eError logs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4375\" data-end=\"4406\"\u003e11. \u003cstrong data-start=\"4382\" data-end=\"4406\"\u003eWarranty and Support\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"4407\" data-end=\"4592\"\u003e\n\u003cli data-start=\"4407\" data-end=\"4592\"\u003e\n\u003cp data-start=\"4409\" data-end=\"4592\"\u003eFor technical support and service, contact:\u003cbr data-start=\"4452\" data-end=\"4455\"\u003e\u003cstrong data-start=\"4457\" data-end=\"4487\"\u003eFronius International GmbH\u003c\/strong\u003e\u003cbr data-start=\"4487\" data-end=\"4490\"\u003e\u003cstrong data-start=\"4492\" data-end=\"4504\"\u003eWebsite:\u003c\/strong\u003e https:\/\/www.fronius.com\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-mxwopdm6.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cbr data-start=\"4555\" data-end=\"4558\"\u003e\u003cstrong data-start=\"4560\" data-end=\"4570\"\u003eEmail:\u003c\/strong\u003e support@fronius.com\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fronius INVERTER","offers":[{"title":"Default Title","offer_id":48348586115405,"sku":"","price":300.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/Screenshot-2024-03-12-15-13-51-54_260528048de7f2f358f0056f785be619.jpg?v=1710249315","url":"https:\/\/greenenergy-repair.com\/pl\/products\/fronius-ig-plus-35v-1-3500va-4-210-015-3150w-230vac-fully-working","provider":"Green Energy","version":"1.0","type":"link"}