{"product_id":"current-cost-envir-cc128-energy-monitor-ct-clamp","title":"Current Cost EnviR CC128 | Energy Monitor | CT Clamp","description":"\u003ch3 dir=\"auto\" data-start=\"59\" data-end=\"81\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"66\" data-end=\"81\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"82\" data-end=\"750\"\u003e\u003cstrong data-start=\"82\" data-end=\"98\"\u003eNew product,\u003c\/strong\u003e Current Cost \u003cstrong data-start=\"112\" data-end=\"121\"\u003eEnviR\u003c\/strong\u003e energy monitoring system, consisting of an LCD display, wireless transmitter and \u003cstrong data-start=\"203\" data-end=\"223\"\u003eCT current clamp\u003c\/strong\u003e, designed to display electrical consumption in real time.\u003cbr\u003eThe system detects current through the CT clamp and transmits the data to the display via a \u003cstrong data-start=\"374\" data-end=\"385\"\u003e433 MHz\u003c\/strong\u003e radio connection. The display allows instantaneous power, consumption and related costs to be viewed according to the configured tariff.\u003cbr\u003eThe photographs show the \u003cstrong data-start=\"548\" data-end=\"639\"\u003eEnviR display, black transmitter with integrated antenna and Current Cost current clamp\u003c\/strong\u003e. The system is particularly suitable for monitoring household electricity consumption and small installations.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"751\" data-end=\"781\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"758\" data-end=\"781\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"782\" data-end=\"1181\"\u003e\n\u003cli data-start=\"782\" data-end=\"811\"\u003e\n\u003cstrong data-start=\"784\" data-end=\"794\"\u003eBrand:\u003c\/strong\u003e \u003cstrong data-start=\"795\" data-end=\"811\"\u003eCurrent Cost\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"812\" data-end=\"835\"\u003e\n\u003cstrong data-start=\"814\" data-end=\"825\"\u003eSystem:\u003c\/strong\u003e \u003cstrong data-start=\"826\" data-end=\"835\"\u003eEnviR\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"836\" data-end=\"874\"\u003e\n\u003cstrong data-start=\"838\" data-end=\"856\"\u003eMonitor model:\u003c\/strong\u003e \u003cstrong data-start=\"857\" data-end=\"874\"\u003eEnviR \/ CC128\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"875\" data-end=\"913\"\u003e\n\u003cstrong data-start=\"877\" data-end=\"886\"\u003eType:\u003c\/strong\u003e wireless energy monitoring\u003c\/li\u003e\n\u003cli data-start=\"914\" data-end=\"927\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-start=\"928\" data-end=\"950\"\u003eWireless transmitter\u003c\/li\u003e\n\u003cli data-start=\"951\" data-end=\"973\"\u003e\n\u003cstrong data-start=\"953\" data-end=\"959\"\u003eCT\u003c\/strong\u003e current clamp\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"1008\"\u003e\n\u003cstrong data-start=\"976\" data-end=\"996\"\u003eRadio frequency:\u003c\/strong\u003e \u003cstrong data-start=\"997\" data-end=\"1008\"\u003e433 MHz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1009\" data-end=\"1038\"\u003eInstantaneous power display\u003c\/li\u003e\n\u003cli data-start=\"1039\" data-end=\"1067\"\u003eEnergy consumption display\u003c\/li\u003e\n\u003cli data-start=\"1068\" data-end=\"1117\"\u003eCost calculation according to configured tariff\u003c\/li\u003e\n\u003cli data-start=\"1118\" data-end=\"1143\"\u003eHistorical data display\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1181\"\u003ePower supplied via external adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1182\" data-end=\"1207\"\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong data-start=\"1189\" data-end=\"1207\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1208\" data-end=\"1636\"\u003e\n\u003cli data-start=\"1208\" data-end=\"1253\"\u003eIndirect measurement of electrical current.\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1322\"\u003eWireless transmission of data from the transmitter to the display.\u003c\/li\u003e\n\u003cli data-start=\"1323\" data-end=\"1364\"\u003eReal-time display of power consumption.\u003c\/li\u003e\n\u003cli data-start=\"1365\" data-end=\"1400\"\u003eMonitoring of consumption trends.\u003c\/li\u003e\n\u003cli data-start=\"1401\" data-end=\"1442\"\u003eIndicative calculation of energy costs.\u003c\/li\u003e\n\u003cli data-start=\"1443\" data-end=\"1636\"\u003eStorage and comparison of consumption data.\u003cbr\u003eThe system periodically sends data from the transmitter to the display; the documentation indicates transmission approximately every \u003cstrong data-start=\"1622\" data-end=\"1635\"\u003e6 seconds\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1637\" data-end=\"1669\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"1644\" data-end=\"1669\"\u003ePurpose and Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1670\" data-end=\"2210\"\u003eThe \u003cstrong data-start=\"1674\" data-end=\"1702\"\u003eCT (Current Transformer)\u003c\/strong\u003e clamp is installed around the conductor being monitored. The current flowing through the cable generates a magnetic field, which is detected by the clamp and converted by the transmitter into consumption-related information.\u003cbr\u003eThe transmitter then sends the data by radio to the EnviR display, which shows the power consumption and energy information.\u003cbr\u003eFor correct measurement, the clamp must be installed around the \u003cstrong data-start=\"2117\" data-end=\"2137\"\u003esingle conductor\u003c\/strong\u003e specified by the system and not around a complete multi-conductor cable.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"2211\" data-end=\"2235\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"2218\" data-end=\"2235\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2236\" data-end=\"2274\"\u003eThe system is intended for monitoring:\u003c\/p\u003e\n\u003cul data-start=\"2275\" data-end=\"2575\"\u003e\n\u003cli data-start=\"2275\" data-end=\"2312\"\u003ehousehold electrical installations;\u003c\/li\u003e\n\u003cli data-start=\"2313\" data-end=\"2346\"\u003esmall commercial installations;\u003c\/li\u003e\n\u003cli data-start=\"2347\" data-end=\"2377\"\u003eindividual electrical lines;\u003c\/li\u003e\n\u003cli data-start=\"2378\" data-end=\"2397\"\u003eelectrical loads;\u003c\/li\u003e\n\u003cli data-start=\"2398\" data-end=\"2575\"\u003eenergy monitoring systems.\u003cbr\u003eThe EnviR receiver operates in the \u003cstrong data-start=\"2462\" data-end=\"2473\"\u003e433 MHz\u003c\/strong\u003e band and supports recognition of multiple compatible channels\/sensors from the Current Cost platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2576\" data-end=\"2614\"\u003e\u003cspan role=\"text\"\u003e⚠️ \u003cstrong data-start=\"2583\" data-end=\"2614\"\u003eTypical Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2615\" data-end=\"3033\"\u003e\n\u003cli data-start=\"2615\" data-end=\"2639\"\u003eDisplay without power.\u003c\/li\u003e\n\u003cli data-start=\"2640\" data-end=\"2682\"\u003eNo signal received from the transmitter.\u003c\/li\u003e\n\u003cli data-start=\"2683\" data-end=\"2709\"\u003eZero or missing reading.\u003c\/li\u003e\n\u003cli data-start=\"2710\" data-end=\"2735\"\u003eIncorrect power values.\u003c\/li\u003e\n\u003cli data-start=\"2736\" data-end=\"2786\"\u003eLoss of pairing between display and transmitter.\u003c\/li\u003e\n\u003cli data-start=\"2787\" data-end=\"2817\"\u003eUnstable radio transmission.\u003c\/li\u003e\n\u003cli data-start=\"2818\" data-end=\"2872\"\u003eDamaged CT clamp or incorrect installation position.\u003c\/li\u003e\n\u003cli data-start=\"2873\" data-end=\"3033\"\u003eFaulty power adapter.\u003cbr\u003eAn abnormal reading does not necessarily indicate an electronic fault: clamp positioning and system configuration may affect the result.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3034\" data-end=\"3054\"\u003e\u003cspan role=\"text\"\u003e🔍 \u003cstrong data-start=\"3041\" data-end=\"3054\"\u003eDiagnosis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3055\" data-end=\"3078\"\u003eInspection may include:\u003c\/p\u003e\n\u003col data-start=\"3079\" data-end=\"3367\"\u003e\n\u003cli data-start=\"3079\" data-end=\"3117\"\u003echecking the display power adapter;\u003c\/li\u003e\n\u003cli data-start=\"3118\" data-end=\"3150\"\u003echecking transmitter startup;\u003c\/li\u003e\n\u003cli data-start=\"3151\" data-end=\"3191\"\u003echecking display\/transmitter pairing;\u003c\/li\u003e\n\u003cli data-start=\"3192\" data-end=\"3228\"\u003echecking the CT clamp connection;\u003c\/li\u003e\n\u003cli data-start=\"3229\" data-end=\"3267\"\u003echecking correct clamp positioning;\u003c\/li\u003e\n\u003cli data-start=\"3268\" data-end=\"3299\"\u003echecking radio transmission;\u003c\/li\u003e\n\u003cli data-start=\"3300\" data-end=\"3367\"\u003ecomparing the reading with the electrical load actually present.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 dir=\"auto\" data-start=\"3368\" data-end=\"3414\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3376\" data-end=\"3414\"\u003eCommon Services in Case of Failure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3415\" data-end=\"3612\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3433\"\u003eDisplay testing.\u003c\/li\u003e\n\u003cli data-start=\"3434\" data-end=\"3456\"\u003eTransmitter testing.\u003c\/li\u003e\n\u003cli data-start=\"3457\" data-end=\"3476\"\u003eCT clamp testing.\u003c\/li\u003e\n\u003cli data-start=\"3477\" data-end=\"3504\"\u003ePower adapter inspection.\u003c\/li\u003e\n\u003cli data-start=\"3505\" data-end=\"3536\"\u003eWireless pairing restoration.\u003c\/li\u003e\n\u003cli data-start=\"3537\" data-end=\"3573\"\u003e433 MHz transmission verification.\u003c\/li\u003e\n\u003cli data-start=\"3574\" data-end=\"3612\"\u003eReplacement of the faulty component.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3613\" data-end=\"3637\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3621\" data-end=\"3637\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3638\" data-end=\"3879\"\u003e\n\u003cli data-start=\"3638\" data-end=\"3680\"\u003eHousehold energy consumption monitoring.\u003c\/li\u003e\n\u003cli data-start=\"3681\" data-end=\"3701\"\u003eEnergy monitoring.\u003c\/li\u003e\n\u003cli data-start=\"3702\" data-end=\"3731\"\u003eElectrical load monitoring.\u003c\/li\u003e\n\u003cli data-start=\"3732\" data-end=\"3781\"\u003eMonitoring of small photovoltaic installations.\u003c\/li\u003e\n\u003cli data-start=\"3782\" data-end=\"3826\"\u003eConsumption analysis in homes and offices.\u003c\/li\u003e\n\u003cli data-start=\"3827\" data-end=\"3879\"\u003eMonitoring of energy absorbed by individual lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3880\" data-end=\"3909\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"3888\" data-end=\"3909\"\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3910\" data-end=\"4009\"\u003e\u003cstrong data-start=\"3910\" data-end=\"3926\"\u003eUsed product\u003c\/strong\u003e, with normal cosmetic signs due to previous use and storage.\u003cbr\u003eThe photographs show:\u003c\/p\u003e\n\u003cul data-start=\"4010\" data-end=\"4074\"\u003e\n\u003cli data-start=\"4010\" data-end=\"4026\"\u003eEnviR display;\u003c\/li\u003e\n\u003cli data-start=\"4027\" data-end=\"4050\"\u003ewireless transmitter;\u003c\/li\u003e\n\u003cli data-start=\"4051\" data-end=\"4074\"\u003eone CT current clamp.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4075\" data-end=\"4102\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"4082\" data-end=\"4102\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4103\" data-end=\"4318\"\u003e\n\u003cli data-start=\"4103\" data-end=\"4139\"\u003e\u003cstrong data-start=\"4105\" data-end=\"4139\"\u003e1 × Current Cost EnviR Display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"4140\" data-end=\"4183\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4183\"\u003e1 × Current Cost wireless transmitter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"4184\" data-end=\"4210\"\u003e\u003cstrong data-start=\"4186\" data-end=\"4210\"\u003e1 × CT current clamp\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"4211\" data-end=\"4318\"\u003ePower adapter\/accessories \u003cstrong data-start=\"4239\" data-end=\"4265\"\u003eif present and working\u003c\/strong\u003e, according to what is actually included in the sale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4319\" data-end=\"4337\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"4326\" data-end=\"4337\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4338\" data-end=\"4915\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"4342\" data-end=\"4364\"\u003eCurrent Cost EnviR\u003c\/strong\u003e is a wireless system for monitoring electrical consumption, consisting of a display, transmitter and CT current clamp. Current is measured without interrupting the circuit and transmitted to the display via \u003cstrong data-start=\"4572\" data-end=\"4583\"\u003e433 MHz\u003c\/strong\u003e radio, allowing power, consumption and energy costs to be viewed.\u003cbr\u003e\u003cstrong data-start=\"4650\" data-end=\"4666\"\u003eSafety Note:\u003c\/strong\u003e Installation of the clamp on electrical panels or supply conductors must be carried out by qualified personnel in accordance with applicable regulations. The Current Cost manual requires particular care when installing the system on mains circuits.\u003c\/p\u003e","brand":"Current Cost","offers":[{"title":"Default Title","offer_id":54970656915789,"sku":null,"price":50.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7093.jpg?v=1791302632","url":"https:\/\/greenenergy-repair.com\/pl\/products\/current-cost-envir-cc128-energy-monitor-ct-clamp","provider":"Green Energy","version":"1.0","type":"link"}