{"product_id":"aurora-abb-pvi-12-0-i-outd-12-0kw-12000w-three-phase-photovoltaic-inverter","title":"ABB Aurora PVI-12.0-I-OUTD – 12kW Three-Phase Photovoltaic Inverter with Amorphous Transformer | 380Vac Grid-Tie","description":"\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThree-phase photovoltaic inverter \u003c\/span\u003e\u003cstrong data-start=\"185\" data-end=\"215\" style=\"font-size: 0.875rem;\"\u003eABB Aurora PVI-12.0-I-OUTD\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e, designed for commercial and industrial photovoltaic systems connected to a three-phase electrical grid.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"322\" data-end=\"536\"\u003eThis \u003cstrong data-start=\"327\" data-end=\"353\"\u003e12kW \/ 12000W inverter\u003c\/strong\u003e uses a high-efficiency \u003cstrong data-start=\"377\" data-end=\"415\"\u003eamorphous transformer architecture\u003c\/strong\u003e, providing galvanic isolation between the DC and AC sides, excellent operational reliability, and reduced energy losses.\u003c\/p\u003e\n\u003cp data-start=\"538\" data-end=\"730\"\u003eThe \u003cstrong data-start=\"542\" data-end=\"556\"\u003ePVI-I-OUTD\u003c\/strong\u003e series is engineered for outdoor installation and is widely appreciated for its robust construction, stable performance, and long-term durability in industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"732\" data-end=\"891\"\u003eThe inverter integrates advanced \u003cstrong data-start=\"765\" data-end=\"789\"\u003eMPPT control systems\u003c\/strong\u003e, grid protection functions, and electronic diagnostics for continuous photovoltaic system monitoring.\u003c\/p\u003e\n\u003chr data-start=\"893\" data-end=\"896\"\u003e\n\u003ch2 data-start=\"898\" data-end=\"917\"\u003e⚙️ Main Features\u003c\/h2\u003e\n\u003cp data-start=\"919\" data-end=\"1238\"\u003e✔ Rated AC power: \u003cstrong data-start=\"937\" data-end=\"945\"\u003e12kW\u003c\/strong\u003e\u003cbr data-start=\"945\" data-end=\"948\"\u003e✔ Three-phase grid-connected inverter\u003cbr data-start=\"985\" data-end=\"988\"\u003e✔ Integrated amorphous transformer\u003cbr data-start=\"1022\" data-end=\"1025\"\u003e✔ DC\/AC galvanic isolation\u003cbr data-start=\"1051\" data-end=\"1054\"\u003e✔ Outdoor installation design\u003cbr data-start=\"1083\" data-end=\"1086\"\u003e✔ High industrial reliability\u003cbr data-start=\"1115\" data-end=\"1118\"\u003e✔ Advanced MPPT management\u003cbr data-start=\"1144\" data-end=\"1147\"\u003e✔ Optimized cooling system\u003cbr data-start=\"1173\" data-end=\"1176\"\u003e✔ Suitable for commercial and industrial photovoltaic plants\u003c\/p\u003e\n\u003chr data-start=\"1240\" data-end=\"1243\"\u003e\n\u003ch2 data-start=\"1245\" data-end=\"1275\"\u003e🔧 Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1277\" data-end=\"1697\"\u003e\n\u003cli data-start=\"1277\" data-end=\"1302\"\u003e\n\u003cstrong data-start=\"1279\" data-end=\"1296\"\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli data-start=\"1303\" data-end=\"1325\"\u003e\n\u003cstrong data-start=\"1305\" data-end=\"1316\"\u003eSeries:\u003c\/strong\u003e Aurora\u003c\/li\u003e\n\u003cli data-start=\"1326\" data-end=\"1356\"\u003e\n\u003cstrong data-start=\"1328\" data-end=\"1338\"\u003eModel:\u003c\/strong\u003e PVI-12.0-I-OUTD\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1404\"\u003e\n\u003cstrong data-start=\"1359\" data-end=\"1368\"\u003eType:\u003c\/strong\u003e Three-phase photovoltaic inverter\u003c\/li\u003e\n\u003cli data-start=\"1405\" data-end=\"1441\"\u003e\n\u003cstrong data-start=\"1407\" data-end=\"1423\"\u003eRated Power:\u003c\/strong\u003e 12.0kW \/ 12000W\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1487\"\u003e\n\u003cstrong data-start=\"1444\" data-end=\"1466\"\u003eAC Output Voltage:\u003c\/strong\u003e 380Vac three-phase\u003c\/li\u003e\n\u003cli data-start=\"1488\" data-end=\"1535\"\u003e\n\u003cstrong data-start=\"1490\" data-end=\"1505\"\u003eTechnology:\u003c\/strong\u003e Amorphous transformer-based\u003c\/li\u003e\n\u003cli data-start=\"1536\" data-end=\"1567\"\u003e\n\u003cstrong data-start=\"1538\" data-end=\"1561\"\u003eGalvanic Isolation:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1597\"\u003e\n\u003cstrong data-start=\"1570\" data-end=\"1587\"\u003eInstallation:\u003c\/strong\u003e Outdoor\u003c\/li\u003e\n\u003cli data-start=\"1598\" data-end=\"1631\"\u003e\n\u003cstrong data-start=\"1600\" data-end=\"1620\"\u003eGrid Connection:\u003c\/strong\u003e Grid-tie\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1697\"\u003e\n\u003cstrong data-start=\"1634\" data-end=\"1650\"\u003eApplication:\u003c\/strong\u003e Commercial \/ industrial photovoltaic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1699\" data-end=\"1702\"\u003e\n\u003ch2 data-start=\"1704\" data-end=\"1755\"\u003e⚡ Advantages of Amorphous Transformer Technology\u003c\/h2\u003e\n\u003cp data-start=\"1757\" data-end=\"1803\"\u003eThe integrated amorphous transformer provides:\u003c\/p\u003e\n\u003cp data-start=\"1805\" data-end=\"2002\"\u003e✔ Reduced magnetic losses\u003cbr data-start=\"1830\" data-end=\"1833\"\u003e✔ Improved energy efficiency\u003cbr data-start=\"1861\" data-end=\"1864\"\u003e✔ Enhanced electrical isolation\u003cbr data-start=\"1895\" data-end=\"1898\"\u003e✔ Lower grid interference and noise\u003cbr data-start=\"1933\" data-end=\"1936\"\u003e✔ Improved long-term reliability\u003cbr data-start=\"1968\" data-end=\"1971\"\u003e✔ Advanced DC-side protection\u003c\/p\u003e\n\u003chr data-start=\"2004\" data-end=\"2007\"\u003e\n\u003ch2 data-start=\"2009\" data-end=\"2027\"\u003e🌐 Applications\u003c\/h2\u003e\n\u003cp data-start=\"2029\" data-end=\"2039\"\u003eIdeal for:\u003c\/p\u003e\n\u003cul data-start=\"2041\" data-end=\"2239\"\u003e\n\u003cli data-start=\"2041\" data-end=\"2076\"\u003eIndustrial photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"2077\" data-end=\"2123\"\u003eCommercial three-phase solar installations\u003c\/li\u003e\n\u003cli data-start=\"2124\" data-end=\"2163\"\u003eIndustrial buildings and warehouses\u003c\/li\u003e\n\u003cli data-start=\"2164\" data-end=\"2198\"\u003ePhotovoltaic retrofit projects\u003c\/li\u003e\n\u003cli data-start=\"2199\" data-end=\"2239\"\u003eSystems requiring galvanic isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2241\" data-end=\"2244\"\u003e\n\u003ch2 data-start=\"2246\" data-end=\"2272\"\u003e🔋 Integrated Functions\u003c\/h2\u003e\n\u003cp data-start=\"2274\" data-end=\"2469\"\u003e✔ Three-phase DC\/AC conversion\u003cbr data-start=\"2304\" data-end=\"2307\"\u003e✔ MPPT management and optimization\u003cbr data-start=\"2341\" data-end=\"2344\"\u003e✔ Grid synchronization\u003cbr data-start=\"2366\" data-end=\"2369\"\u003e✔ Integrated AC\/DC protections\u003cbr data-start=\"2399\" data-end=\"2402\"\u003e✔ Plant parameter monitoring\u003cbr data-start=\"2430\" data-end=\"2433\"\u003e✔ Diagnostics and fault management\u003c\/p\u003e\n\u003chr data-start=\"2471\" data-end=\"2474\"\u003e\n\u003ch2 data-start=\"2476\" data-end=\"2503\"\u003e⚠️ Common Related Errors\u003c\/h2\u003e\n\u003cp data-start=\"2505\" data-end=\"2557\"\u003eABB Aurora PVI inverters may display alarms such as:\u003c\/p\u003e\n\u003cul data-start=\"2559\" data-end=\"2762\"\u003e\n\u003cli data-start=\"2559\" data-end=\"2585\"\u003e\u003cstrong data-start=\"2561\" data-end=\"2583\"\u003eE007 – Relay Fault\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2586\" data-end=\"2611\"\u003e\u003cstrong data-start=\"2588\" data-end=\"2609\"\u003eE016 – Grid Fault\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2612\" data-end=\"2638\"\u003e\u003cstrong data-start=\"2614\" data-end=\"2636\"\u003eE031 – DC\/DC Error\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2639\" data-end=\"2671\"\u003e\u003cstrong data-start=\"2641\" data-end=\"2669\"\u003eE034 – Power Stage Fault\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2672\" data-end=\"2688\"\u003eGround Fault\u003c\/li\u003e\n\u003cli data-start=\"2689\" data-end=\"2708\"\u003eIsolation Fault\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2737\"\u003eInverter startup failure\u003c\/li\u003e\n\u003cli data-start=\"2738\" data-end=\"2762\"\u003eNo energy production\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2764\" data-end=\"2767\"\u003e\n\u003ch2 data-start=\"2769\" data-end=\"2792\"\u003e🛠 Product Condition\u003c\/h2\u003e\n\u003cp data-start=\"2794\" data-end=\"2955\"\u003e✔ Used \/ refurbished \u003cem data-start=\"2815\" data-end=\"2832\"\u003e(if applicable)\u003c\/em\u003e\u003cbr data-start=\"2832\" data-end=\"2835\"\u003e✔ Professionally tested\u003cbr data-start=\"2858\" data-end=\"2861\"\u003e✔ Functional operation verified\u003cbr data-start=\"2892\" data-end=\"2895\"\u003e✔ Complete electronic and power-stage inspection performed\u003c\/p\u003e\n\u003chr data-start=\"2957\" data-end=\"2960\"\u003e\n\u003ch2 data-start=\"2962\" data-end=\"2981\"\u003e🔌 Compatibility\u003c\/h2\u003e\n\u003cp data-start=\"2983\" data-end=\"2999\"\u003eCompatible with:\u003c\/p\u003e\n\u003cul data-start=\"3001\" data-end=\"3161\"\u003e\n\u003cli data-start=\"3001\" data-end=\"3027\"\u003eABB Aurora PVI systems\u003c\/li\u003e\n\u003cli data-start=\"3028\" data-end=\"3077\"\u003eThree-phase 380Vac photovoltaic installations\u003c\/li\u003e\n\u003cli data-start=\"3078\" data-end=\"3122\"\u003eIndustrial grid-tie photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"3123\" data-end=\"3161\"\u003eHigh-power commercial solar plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3163\" data-end=\"3166\"\u003e\n\u003ch2 data-start=\"3168\" data-end=\"3181\"\u003e🟢 Summary\u003c\/h2\u003e\n\u003cp data-start=\"3183\" data-end=\"3383\"\u003eThe \u003cstrong data-start=\"3187\" data-end=\"3217\"\u003eABB Aurora PVI-12.0-I-OUTD\u003c\/strong\u003e is a professional-grade \u003cstrong data-start=\"3242\" data-end=\"3284\"\u003e12kW three-phase photovoltaic inverter\u003c\/strong\u003e featuring an integrated \u003cstrong data-start=\"3309\" data-end=\"3334\"\u003eamorphous transformer\u003c\/strong\u003e for galvanic isolation and enhanced reliability.\u003c\/p\u003e\n\u003cp data-start=\"3385\" data-end=\"3591\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eDesigned for industrial and commercial photovoltaic applications, it delivers stable grid-connected performance, advanced protection features, and long-term operational durability in demanding environments.\u003c\/p\u003e","brand":"ABB Aurora used","offers":[{"title":"Default Title","offer_id":48393104228685,"sku":"","price":1000.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/Screenshot-2024-03-18-14-43-10-11_260528048de7f2f358f0056f785be619.jpg?v=1710765849","url":"https:\/\/greenenergy-repair.com\/pl\/products\/aurora-abb-pvi-12-0-i-outd-12-0kw-12000w-three-phase-photovoltaic-inverter","provider":"Green Energy","version":"1.0","type":"link"}