{"product_id":"aurora-abb-logic-board-pn-3f25-99-1-pb-free-for-pvi-3-0-6-0tl-inverters-used-tested","title":"Aurora ABB Logic Board | PN: 3F25-99-1 Pb-Free | For PVI 3.0–6.0TL Inverters | Used \u0026 Tested","description":"\u003cp data-start=\"254\" data-end=\"605\" class=\"\"\u003eThis is a \u003cstrong data-start=\"264\" data-end=\"287\"\u003egenuine logic board\u003c\/strong\u003e for \u003cstrong data-start=\"292\" data-end=\"328\"\u003eAurora ABB \/ Power-One inverters\u003c\/strong\u003e rated from \u003cstrong data-start=\"340\" data-end=\"358\"\u003e3.0kW to 6.0kW\u003c\/strong\u003e, marked as \u003cstrong data-start=\"370\" data-end=\"391\"\u003e3F25-99-1 Pb-Free\u003c\/strong\u003e. Installed as the \u003cstrong data-start=\"410\" data-end=\"434\"\u003ecentral control unit\u003c\/strong\u003e in the inverter, this board manages all core operations, including \u003cstrong data-start=\"502\" data-end=\"604\"\u003eIGBT switching control, communication with auxiliary modules, grid monitoring, and MPPT management\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"607\" data-end=\"836\" class=\"\"\u003eWhen this board fails, it often results in \u003cstrong data-start=\"650\" data-end=\"680\"\u003ecomplete inverter shutdown\u003c\/strong\u003e, control malfunctions, or persistent communication errors. In many cases, \u003cstrong data-start=\"755\" data-end=\"792\"\u003ereplacement and firmware flashing\u003c\/strong\u003e are required to restore full functionality.\u003c\/p\u003e\n\u003cp data-start=\"838\" data-end=\"932\" class=\"\"\u003e🔄 \u003cstrong data-start=\"841\" data-end=\"855\"\u003eCondition:\u003c\/strong\u003e Used, tested, and verified for performance.\u003cbr data-start=\"899\" data-end=\"902\"\u003e📦 In stock and ready to ship.\u003c\/p\u003e\n\u003ch3 data-start=\"939\" data-end=\"970\" class=\"\"\u003e🔧 \u003cstrong data-start=\"946\" data-end=\"968\"\u003eTechnical Details:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"973\" data-end=\"1013\"\u003e\n\u003cstrong data-start=\"973\" data-end=\"983\"\u003eModel:\u003c\/strong\u003e Power-One 3F25-99-1 Pb-Free\u003c\/li\u003e\n\u003cli data-start=\"1016\" data-end=\"1102\"\u003e\n\u003cstrong data-start=\"1016\" data-end=\"1029\"\u003eFunction:\u003c\/strong\u003e Central logic, control signal processing, and communication management\u003c\/li\u003e\n\u003cli data-start=\"1105\" data-end=\"1143\"\u003e\n\u003cstrong data-start=\"1105\" data-end=\"1115\"\u003eBuild:\u003c\/strong\u003e Lead-free, multilayer PCB\u003c\/li\u003e\n\u003cli data-start=\"1146\" data-end=\"1217\"\u003e\n\u003cstrong data-start=\"1146\" data-end=\"1163\"\u003eInstallation:\u003c\/strong\u003e Direct-fit replacement; may require firmware update\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1224\" data-end=\"1251\" class=\"\"\u003e🔗 \u003cstrong data-start=\"1231\" data-end=\"1249\"\u003eCompatibility:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"1252\" data-end=\"1388\" class=\"\"\u003e✔ \u003cstrong data-start=\"1254\" data-end=\"1293\"\u003eAurora \/ ABB \/ Power-One inverters:\u003c\/strong\u003e\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e• \u003cstrong data-start=\"1298\" data-end=\"1312\"\u003ePVI-3.0-TL\u003c\/strong\u003e\u003cbr data-start=\"1312\" data-end=\"1315\"\u003e• \u003cstrong data-start=\"1317\" data-end=\"1331\"\u003ePVI-3.6-TL\u003c\/strong\u003e\u003cbr data-start=\"1331\" data-end=\"1334\"\u003e• \u003cstrong data-start=\"1336\" data-end=\"1350\"\u003ePVI-4.2-TL\u003c\/strong\u003e\u003cbr data-start=\"1350\" data-end=\"1353\"\u003e• \u003cstrong data-start=\"1355\" data-end=\"1369\"\u003ePVI-5.0-TL\u003c\/strong\u003e\u003cbr data-start=\"1369\" data-end=\"1372\"\u003e• \u003cstrong data-start=\"1374\" data-end=\"1388\"\u003ePVI-6.0-TL\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1395\" data-end=\"1421\" class=\"\"\u003e✅ \u003cstrong data-start=\"1401\" data-end=\"1419\"\u003eKey Functions:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"1422\" data-end=\"1677\" class=\"\"\u003e✔ Controls \u003cstrong data-start=\"1433\" data-end=\"1480\"\u003einverter logic and grid interface protocols\u003c\/strong\u003e\u003cbr data-start=\"1480\" data-end=\"1483\"\u003e✔ Manages \u003cstrong data-start=\"1493\" data-end=\"1537\"\u003eIGBT driver sequences and MPPT operation\u003c\/strong\u003e\u003cbr data-start=\"1537\" data-end=\"1540\"\u003e✔ Handles \u003cstrong data-start=\"1550\" data-end=\"1573\"\u003eRS485 communication\u003c\/strong\u003e with monitoring systems\u003cbr data-start=\"1597\" data-end=\"1600\"\u003e✔ Common point of failure in inverters experiencing startup or control errors\u003c\/p\u003e\n\u003cp data-start=\"1684\" data-end=\"1869\" class=\"\"\u003e⚠️ \u003cstrong data-start=\"1687\" data-end=\"1696\"\u003eNote:\u003c\/strong\u003e\u003cbr data-start=\"1696\" data-end=\"1699\"\u003eA faulty logic board is a common cause of persistent system errors.\u003cbr data-start=\"1766\" data-end=\"1769\"\u003eThis unit may require \u003cstrong data-start=\"1791\" data-end=\"1812\"\u003efirmware flashing\u003c\/strong\u003e upon replacement to match your inverter’s configuration.\u003c\/p\u003e\n\u003cp data-start=\"1871\" data-end=\"1977\" class=\"\"\u003e📦 \u003cstrong data-start=\"1874\" data-end=\"1887\"\u003eIncludes:\u003c\/strong\u003e Logic board only (no cables or accessories)\u003cbr data-start=\"1931\" data-end=\"1934\"\u003e🏷️ \u003cstrong data-start=\"1938\" data-end=\"1952\"\u003eCondition:\u003c\/strong\u003e Used, tested, functional\u003c\/p\u003e\n\u003cp data-start=\"1979\" data-end=\"2077\" class=\"\"\u003e🚀 \u003cstrong data-start=\"1982\" data-end=\"2077\"\u003eRestore inverter intelligence and stable operation with this original ABB logic controller.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB Aurora parts","offers":[{"title":"3kW","offer_id":51649010794829,"sku":"","price":100.0,"currency_code":"EUR","in_stock":true},{"title":"3.6kW","offer_id":51649010827597,"sku":"","price":120.0,"currency_code":"EUR","in_stock":true},{"title":"4.2kW","offer_id":51649010860365,"sku":"","price":130.0,"currency_code":"EUR","in_stock":true},{"title":"5kW","offer_id":51649010893133,"sku":"","price":150.0,"currency_code":"EUR","in_stock":true},{"title":"6kW","offer_id":51649010925901,"sku":"","price":150.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5991.jpg?v=1781017251","url":"https:\/\/greenenergy-repair.com\/pl\/products\/aurora-abb-logic-board-pn-3f25-99-1-pb-free-for-pvi-3-0-6-0tl-inverters-used-tested","provider":"Green Energy","version":"1.0","type":"link"}