{"product_id":"aureora-monitoring-data-logger-abb-power-one-pvi-aec-evo-v2-0","title":"Aurora monitoring data logger ABB Power-One PVI-AEC-EVO v2.0","description":"\u003cp\u003eeverything works.  We also provide a warranty on the components. \u003ca href=\"https:\/\/solarparts.eu\/pages\/faq\"\u003eFAQ\u003c\/a\u003e (SBit) \u003c\/p\u003e\n\u003ch2 data-start=\"112\" data-end=\"129\"\u003e1️⃣ Overview\u003c\/h2\u003e\n\u003cp data-start=\"130\" data-end=\"387\"\u003eThe \u003cstrong data-start=\"134\" data-end=\"168\"\u003eABB Power-One PVI-AEC-EVO v2.0\u003c\/strong\u003e is a \u003cstrong data-start=\"174\" data-end=\"230\"\u003edata logger for monitoring photovoltaic (PV) systems\u003c\/strong\u003e. It collects performance and operational data from ABB Aurora inverters and allows remote monitoring, analysis, and reporting through web-based platforms.\u003c\/p\u003e\n\u003cp data-start=\"389\" data-end=\"404\"\u003eKey features:\u003c\/p\u003e\n\u003cul data-start=\"405\" data-end=\"732\"\u003e\n\u003cli data-start=\"405\" data-end=\"466\"\u003e\n\u003cp data-start=\"407\" data-end=\"466\"\u003eMonitors multiple Aurora inverters via RS-485 or Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"467\" data-end=\"544\"\u003e\n\u003cp data-start=\"469\" data-end=\"544\"\u003eLogs real-time energy production, voltages, currents, and inverter status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"545\" data-end=\"598\"\u003e\n\u003cp data-start=\"547\" data-end=\"598\"\u003eProvides historical data for performance analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"599\" data-end=\"673\"\u003e\n\u003cp data-start=\"601\" data-end=\"673\"\u003eSupports remote access via web portals or networked monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"674\" data-end=\"732\"\u003e\n\u003cp data-start=\"676\" data-end=\"732\"\u003eHelps optimize PV system performance and detect faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"739\" data-end=\"768\"\u003e2️⃣ Safety Instructions ⚠️\u003c\/h2\u003e\n\u003cul data-start=\"770\" data-end=\"1061\"\u003e\n\u003cli data-start=\"770\" data-end=\"837\"\u003e\n\u003cp data-start=\"772\" data-end=\"837\"\u003eInstallation must be performed by \u003cstrong data-start=\"806\" data-end=\"834\"\u003equalified personnel only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"838\" data-end=\"928\"\u003e\n\u003cp data-start=\"840\" data-end=\"928\"\u003eDisconnect all AC and DC power from connected inverters before wiring the data logger.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"998\"\u003e\n\u003cp data-start=\"931\" data-end=\"998\"\u003eAvoid installing in wet, dusty, or high-temperature environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1061\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1061\"\u003eEnsure proper grounding for safety and reliable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1068\" data-end=\"1094\"\u003e3️⃣ System Requirements\u003c\/h2\u003e\n\u003cul data-start=\"1096\" data-end=\"1353\"\u003e\n\u003cli data-start=\"1096\" data-end=\"1168\"\u003e\n\u003cp data-start=\"1098\" data-end=\"1168\"\u003eCompatible ABB Aurora inverters (check inverter model compatibility)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1169\" data-end=\"1229\"\u003e\n\u003cp data-start=\"1171\" data-end=\"1229\"\u003eRS-485 or Ethernet cabling from inverters to data logger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1288\"\u003e\n\u003cp data-start=\"1232\" data-end=\"1288\"\u003eNetwork connection for web portal or remote monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1289\" data-end=\"1353\"\u003e\n\u003cp data-start=\"1291\" data-end=\"1353\"\u003eOptional PC or laptop for configuration and local monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1360\" data-end=\"1379\"\u003e4️⃣ Installation\u003c\/h2\u003e\n\u003ch3 data-start=\"1381\" data-end=\"1396\"\u003eA. Mounting\u003c\/h3\u003e\n\u003col data-start=\"1397\" data-end=\"1579\"\u003e\n\u003cli data-start=\"1397\" data-end=\"1476\"\u003e\n\u003cp data-start=\"1400\" data-end=\"1476\"\u003eMount the data logger on a wall or DIN rail in a dry, ventilated location.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1529\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1529\"\u003eEnsure accessibility for wiring and monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1579\"\u003e\n\u003cp data-start=\"1533\" data-end=\"1579\"\u003eAvoid direct sunlight and moisture exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"1581\" data-end=\"1608\"\u003eB. Communication Wiring\u003c\/h3\u003e\n\u003col data-start=\"1609\" data-end=\"2040\"\u003e\n\u003cli data-start=\"1609\" data-end=\"1832\"\u003e\n\u003cp data-start=\"1612\" data-end=\"1635\"\u003e\u003cstrong data-start=\"1612\" data-end=\"1633\"\u003eRS-485 Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1639\" data-end=\"1832\"\u003e\n\u003cli data-start=\"1639\" data-end=\"1689\"\u003e\n\u003cp data-start=\"1641\" data-end=\"1689\"\u003eConnect RS-485 A\/B terminals to the inverters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1693\" data-end=\"1754\"\u003e\n\u003cp data-start=\"1695\" data-end=\"1754\"\u003eUse twisted pair cabling recommended for RS-485 networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1758\" data-end=\"1832\"\u003e\n\u003cp data-start=\"1760\" data-end=\"1832\"\u003eTerminate the RS-485 bus with 120 Ω resistors at each end if required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1834\" data-end=\"1972\"\u003e\n\u003cp data-start=\"1837\" data-end=\"1863\"\u003e\u003cstrong data-start=\"1837\" data-end=\"1861\"\u003eEthernet (optional):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1867\" data-end=\"1972\"\u003e\n\u003cli data-start=\"1867\" data-end=\"1934\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1934\"\u003eConnect the RJ45 port to the local network for internet access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1938\" data-end=\"1972\"\u003e\n\u003cp data-start=\"1940\" data-end=\"1972\"\u003eAssign IP addresses if needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1974\" data-end=\"2040\"\u003e\n\u003cp data-start=\"1977\" data-end=\"2040\"\u003eCheck wiring polarity and shielding for proper communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"2042\" data-end=\"2061\"\u003eC. Power Supply\u003c\/h3\u003e\n\u003col data-start=\"2062\" data-end=\"2216\"\u003e\n\u003cli data-start=\"2062\" data-end=\"2169\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2169\"\u003eConnect the data logger to its power source (typically 12–24 V DC or 230 V AC depending on the model).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2170\" data-end=\"2216\"\u003e\n\u003cp data-start=\"2173\" data-end=\"2216\"\u003eVerify LED indicators power-on correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2223\" data-end=\"2253\"\u003e5️⃣ Configuration Procedure\u003c\/h2\u003e\n\u003col data-start=\"2255\" data-end=\"2631\"\u003e\n\u003cli data-start=\"2255\" data-end=\"2312\"\u003e\n\u003cp data-start=\"2258\" data-end=\"2312\"\u003eConnect a PC to the data logger via Ethernet or USB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2313\" data-end=\"2411\"\u003e\n\u003cp data-start=\"2316\" data-end=\"2411\"\u003eAccess the device configuration page using a web browser (IP address provided in the manual).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2412\" data-end=\"2480\"\u003e\n\u003cp data-start=\"2415\" data-end=\"2480\"\u003eSet up inverter network settings (RS-485 addresses, baud rate).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2481\" data-end=\"2550\"\u003e\n\u003cp data-start=\"2484\" data-end=\"2550\"\u003eConfigure connection to web portal or local monitoring software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2551\" data-end=\"2631\"\u003e\n\u003cp data-start=\"2554\" data-end=\"2631\"\u003eTest communication with each inverter to ensure data logging is functional.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2638\" data-end=\"2667\"\u003e6️⃣ Monitoring \u0026amp; Operation\u003c\/h2\u003e\n\u003cul data-start=\"2669\" data-end=\"3021\"\u003e\n\u003cli data-start=\"2669\" data-end=\"2758\"\u003e\n\u003cp data-start=\"2671\" data-end=\"2758\"\u003e\u003cstrong data-start=\"2671\" data-end=\"2696\"\u003eReal-time Monitoring:\u003c\/strong\u003e View inverter status, power output, voltages, and currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2759\" data-end=\"2836\"\u003e\n\u003cp data-start=\"2761\" data-end=\"2836\"\u003e\u003cstrong data-start=\"2761\" data-end=\"2781\"\u003eHistorical Data:\u003c\/strong\u003e Access daily, monthly, and yearly energy statistics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2837\" data-end=\"2915\"\u003e\n\u003cp data-start=\"2839\" data-end=\"2915\"\u003e\u003cstrong data-start=\"2839\" data-end=\"2857\"\u003eFault Logging:\u003c\/strong\u003e Records inverter faults and events for troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2916\" data-end=\"3021\"\u003e\n\u003cp data-start=\"2918\" data-end=\"3021\"\u003e\u003cstrong data-start=\"2918\" data-end=\"2936\"\u003eRemote Access:\u003c\/strong\u003e View system performance remotely via web portal or compatible monitoring software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3028\" data-end=\"3046\"\u003e7️⃣ Maintenance\u003c\/h2\u003e\n\u003cul data-start=\"3048\" data-end=\"3316\"\u003e\n\u003cli data-start=\"3048\" data-end=\"3111\"\u003e\n\u003cp data-start=\"3050\" data-end=\"3111\"\u003eKeep the data logger clean and free from dust and moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3112\" data-end=\"3169\"\u003e\n\u003cp data-start=\"3114\" data-end=\"3169\"\u003eInspect RS-485 and Ethernet connections periodically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3170\" data-end=\"3223\"\u003e\n\u003cp data-start=\"3172\" data-end=\"3223\"\u003eCheck LED status indicators for proper operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3224\" data-end=\"3316\"\u003e\n\u003cp data-start=\"3226\" data-end=\"3316\"\u003eUpdate firmware via the ABB portal when prompted to maintain compatibility and security.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3323\" data-end=\"3345\"\u003e8️⃣ Troubleshooting\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3347\" data-end=\"3845\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3347\" data-end=\"3384\"\u003e\n\u003ctr data-start=\"3347\" data-end=\"3384\"\u003e\n\u003cth data-start=\"3347\" data-end=\"3357\" data-col-size=\"sm\" class=\"\"\u003eSymptom\u003c\/th\u003e\n\u003cth data-start=\"3357\" data-end=\"3374\" data-col-size=\"md\" class=\"\"\u003ePossible Cause\u003c\/th\u003e\n\u003cth data-start=\"3374\" data-end=\"3384\" data-col-size=\"md\" class=\"\"\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3423\" data-end=\"3845\"\u003e\n\u003ctr data-start=\"3423\" data-end=\"3517\"\u003e\n\u003ctd data-start=\"3423\" data-end=\"3456\" data-col-size=\"sm\"\u003eNo communication with inverter\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3456\" data-end=\"3478\"\u003eRS-485 wiring issue\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3478\" data-end=\"3517\"\u003eVerify A\/B polarity and connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3518\" data-end=\"3619\"\u003e\n\u003ctd data-start=\"3518\" data-end=\"3542\" data-col-size=\"sm\"\u003eNo data on web portal\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3542\" data-end=\"3570\"\u003eNetwork or Internet issue\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3570\" data-end=\"3619\"\u003eCheck Ethernet connection and router settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3620\" data-end=\"3704\"\u003e\n\u003ctd data-start=\"3620\" data-end=\"3642\" data-col-size=\"sm\"\u003eError LED on logger\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3642\" data-end=\"3668\"\u003eHardware fault or short\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3668\" data-end=\"3704\"\u003eContact ABB-certified technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3705\" data-end=\"3845\"\u003e\n\u003ctd data-start=\"3705\" data-end=\"3725\" data-col-size=\"sm\"\u003eIntermittent data\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3725\" data-end=\"3770\"\u003eElectrical noise or excessive cable length\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3770\" data-end=\"3845\"\u003eUse twisted pair cables, proper grounding, reduce RS-485 segment length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-start=\"3852\" data-end=\"3877\"\u003e9️⃣ Shutdown Procedure\u003c\/h2\u003e\n\u003col data-start=\"3879\" data-end=\"4039\"\u003e\n\u003cli data-start=\"3879\" data-end=\"3910\"\u003e\n\u003cp data-start=\"3882\" data-end=\"3910\"\u003ePower off the data logger.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3911\" data-end=\"3980\"\u003e\n\u003cp data-start=\"3914\" data-end=\"3980\"\u003eDisconnect RS-485 and Ethernet cables if performing maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3981\" data-end=\"4039\"\u003e\n\u003cp data-start=\"3984\" data-end=\"4039\"\u003eEnsure connected inverters continue normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"4046\" data-end=\"4067\"\u003eTechnical Summary\u003c\/h3\u003e\n\u003cul data-start=\"4069\" data-end=\"4415\"\u003e\n\u003cli data-start=\"4069\" data-end=\"4117\"\u003e\n\u003cp data-start=\"4071\" data-end=\"4117\"\u003eInterface: RS-485 for inverter communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4118\" data-end=\"4157\"\u003e\n\u003cp data-start=\"4120\" data-end=\"4157\"\u003eOptional Ethernet for portal access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4158\" data-end=\"4216\"\u003e\n\u003cp data-start=\"4160\" data-end=\"4216\"\u003ePower Supply: 12–24 V DC or 230 V AC (model dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4217\" data-end=\"4258\"\u003e\n\u003cp data-start=\"4219\" data-end=\"4258\"\u003eCompatible with: ABB Aurora inverters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4259\" data-end=\"4289\"\u003e\n\u003cp data-start=\"4261\" data-end=\"4289\"\u003eMounting: Wall or DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4290\" data-end=\"4344\"\u003e\n\u003cp data-start=\"4292\" data-end=\"4344\"\u003eData Access: Web portal, local monitoring software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":48306001346893,"sku":"","price":550.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5985.jpg?v=1781013921","url":"https:\/\/greenenergy-repair.com\/pl\/products\/aureora-monitoring-data-logger-abb-power-one-pvi-aec-evo-v2-0","provider":"Green Energy","version":"1.0","type":"link"}