{"product_id":"protechnic-magic-mgt6012ub-w25-12-v-dc-4-56-w","title":"Protechnic MAGIC MGT6012UB-W25 | 12 V DC | 4.56 W","description":"\u003ch3 dir=\"auto\" data-start=\"56\" data-end=\"78\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"63\" data-end=\"78\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"79\" data-end=\"656\"\u003e\u003cstrong data-start=\"79\" data-end=\"95\"\u003eUsed product\u003c\/strong\u003e and \u003cstrong data-start=\"100\" data-end=\"153\"\u003efunctioning at the time of packaging and shipment\u003c\/strong\u003e, as shown in the photograph. Professional \u003cstrong data-start=\"196\" data-end=\"239\"\u003eProtechnic Electric MAGIC MGT6012UB-W25\u003c\/strong\u003e axial fan, designed for forced cooling of electronic equipment, power supplies, inverters, servers and industrial systems.\u003cbr\u003eThe label clearly identifies model \u003cstrong data-start=\"398\" data-end=\"415\"\u003eMGT6012UB-W25\u003c\/strong\u003e, \u003cstrong data-start=\"417\" data-end=\"428\"\u003e12 V DC\u003c\/strong\u003e power supply and rated current \u003cstrong data-start=\"460\" data-end=\"470\"\u003e0.38 A\u003c\/strong\u003e. Technical documentation for the model confirms \u003cstrong data-start=\"519\" data-end=\"538\"\u003e60 × 60 × 25 mm\u003c\/strong\u003e size, rated power \u003cstrong data-start=\"557\" data-end=\"567\"\u003e4.56 W\u003c\/strong\u003e, speed of approximately \u003cstrong data-start=\"592\" data-end=\"605\"\u003e6,800 rpm\u003c\/strong\u003e and maximum airflow of approximately \u003cstrong data-start=\"643\" data-end=\"655\"\u003e35.5 CFM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"657\" data-end=\"687\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"664\" data-end=\"687\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"688\" data-end=\"1246\"\u003e\n\u003cli data-start=\"688\" data-end=\"732\"\u003e\n\u003cstrong data-start=\"690\" data-end=\"700\"\u003eBrand:\u003c\/strong\u003e \u003cstrong data-start=\"701\" data-end=\"732\"\u003eProtechnic Electric \/ MAGIC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"733\" data-end=\"763\"\u003e\n\u003cstrong data-start=\"735\" data-end=\"745\"\u003eModel:\u003c\/strong\u003e \u003cstrong data-start=\"746\" data-end=\"763\"\u003eMGT6012UB-W25\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"764\" data-end=\"788\"\u003e\n\u003cstrong data-start=\"766\" data-end=\"775\"\u003eType:\u003c\/strong\u003e DC axial fan\u003c\/li\u003e\n\u003cli data-start=\"789\" data-end=\"822\"\u003e\n\u003cstrong data-start=\"791\" data-end=\"810\"\u003eSupply voltage:\u003c\/strong\u003e \u003cstrong data-start=\"811\" data-end=\"822\"\u003e12 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"823\" data-end=\"854\"\u003e\n\u003cstrong data-start=\"825\" data-end=\"843\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"844\" data-end=\"854\"\u003e0.38 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"855\" data-end=\"884\"\u003e\n\u003cstrong data-start=\"857\" data-end=\"873\"\u003eRated power:\u003c\/strong\u003e \u003cstrong data-start=\"874\" data-end=\"884\"\u003e4.56 W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"885\" data-end=\"922\"\u003e\n\u003cstrong data-start=\"887\" data-end=\"902\"\u003eDimensions:\u003c\/strong\u003e \u003cstrong data-start=\"903\" data-end=\"922\"\u003e60 × 60 × 25 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"923\" data-end=\"957\"\u003e\n\u003cstrong data-start=\"925\" data-end=\"935\"\u003eSpeed:\u003c\/strong\u003e approx. \u003cstrong data-start=\"944\" data-end=\"957\"\u003e6,800 rpm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"958\" data-end=\"1016\"\u003e\n\u003cstrong data-start=\"960\" data-end=\"980\"\u003eMaximum airflow:\u003c\/strong\u003e approx. \u003cstrong data-start=\"989\" data-end=\"1016\"\u003e35.5 CFM \/ 1.006 m³\/min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1017\" data-end=\"1060\"\u003e\n\u003cstrong data-start=\"1019\" data-end=\"1039\"\u003eStatic pressure:\u003c\/strong\u003e approx. \u003cstrong data-start=\"1048\" data-end=\"1060\"\u003e123.6 Pa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1061\" data-end=\"1102\"\u003e\n\u003cstrong data-start=\"1063\" data-end=\"1079\"\u003eNoise level:\u003c\/strong\u003e approx. \u003cstrong data-start=\"1088\" data-end=\"1102\"\u003e43.1 dB(A)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1135\"\u003e\n\u003cstrong data-start=\"1105\" data-end=\"1118\"\u003eBearings:\u003c\/strong\u003e \u003cstrong data-start=\"1119\" data-end=\"1135\"\u003eball bearing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1136\" data-end=\"1165\"\u003e\n\u003cstrong data-start=\"1138\" data-end=\"1153\"\u003eConnection:\u003c\/strong\u003e \u003cstrong data-start=\"1154\" data-end=\"1165\"\u003e4 wires\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1166\" data-end=\"1194\"\u003e\n\u003cstrong data-start=\"1168\" data-end=\"1186\"\u003eSpeed control:\u003c\/strong\u003e \u003cstrong data-start=\"1187\" data-end=\"1194\"\u003ePWM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1195\" data-end=\"1246\"\u003e\u003cstrong data-start=\"1197\" data-end=\"1246\"\u003eLocked-rotor protection and automatic restart\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1247\" data-end=\"1272\"\u003e\u003cspan role=\"text\"\u003e🔧 \u003cstrong data-start=\"1254\" data-end=\"1272\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1273\" data-end=\"1542\"\u003eThe fan generates forced airflow to control the temperature of electronic and power components.\u003cbr\u003eThe four-wire connection allows, in equipment designed for this purpose, electronic speed management via \u003cstrong data-start=\"1474\" data-end=\"1481\"\u003ePWM\u003c\/strong\u003e, in addition to power supply and control\/monitoring signals.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"1543\" data-end=\"1575\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"1550\" data-end=\"1575\"\u003ePurpose and Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1576\" data-end=\"1864\"\u003eIt is used to dissipate heat generated by power semiconductors, power supplies, converters and other electronic components.\u003cbr\u003eThe high speed and good static pressure make this model particularly suitable for equipment where airflow must pass through heat sinks or relatively compact spaces.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"1865\" data-end=\"1889\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"1872\" data-end=\"1889\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1890\" data-end=\"2039\"\u003eIt can be used as a replacement in equipment using the \u003cstrong data-start=\"1945\" data-end=\"1962\"\u003eMGT6012UB-W25\u003c\/strong\u003e or a fan with equivalent characteristics.\u003cbr\u003eBefore replacement, always verify:\u003c\/p\u003e\n\u003cul data-start=\"2040\" data-end=\"2503\"\u003e\n\u003cli data-start=\"2040\" data-end=\"2067\"\u003e\n\u003cstrong data-start=\"2042\" data-end=\"2053\"\u003e12 V DC\u003c\/strong\u003e power supply;\u003c\/li\u003e\n\u003cli data-start=\"2068\" data-end=\"2101\"\u003e\n\u003cstrong data-start=\"2070\" data-end=\"2089\"\u003e60 × 60 × 25 mm\u003c\/strong\u003e dimensions;\u003c\/li\u003e\n\u003cli data-start=\"2102\" data-end=\"2124\"\u003ecurrent consumption;\u003c\/li\u003e\n\u003cli data-start=\"2125\" data-end=\"2153\"\u003emounting hole arrangement;\u003c\/li\u003e\n\u003cli data-start=\"2154\" data-end=\"2185\"\u003enumber and function of wires;\u003c\/li\u003e\n\u003cli data-start=\"2186\" data-end=\"2198\"\u003econnector;\u003c\/li\u003e\n\u003cli data-start=\"2199\" data-end=\"2213\"\u003ePWM control;\u003c\/li\u003e\n\u003cli data-start=\"2214\" data-end=\"2503\"\u003eairflow direction.\u003cbr\u003eThe fan should not be attributed to a specific inverter model based solely on the photograph, because the \u003cstrong data-start=\"2341\" data-end=\"2358\"\u003eMGT6012UB-W25\u003c\/strong\u003e is also used in other electronic equipment and power supplies. It is also documented, for example, inside high-power workstation power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2504\" data-end=\"2542\"\u003e\u003cspan role=\"text\"\u003e⚠️ \u003cstrong data-start=\"2511\" data-end=\"2542\"\u003eTypical Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2543\" data-end=\"2574\"\u003eA worn or faulty fan may cause:\u003c\/p\u003e\n\u003cul data-start=\"2575\" data-end=\"2850\"\u003e\n\u003cli data-start=\"2575\" data-end=\"2594\"\u003efailure to start;\u003c\/li\u003e\n\u003cli data-start=\"2595\" data-end=\"2619\"\u003eintermittent rotation;\u003c\/li\u003e\n\u003cli data-start=\"2620\" data-end=\"2641\"\u003einsufficient speed;\u003c\/li\u003e\n\u003cli data-start=\"2642\" data-end=\"2659\"\u003eabnormal noise;\u003c\/li\u003e\n\u003cli data-start=\"2660\" data-end=\"2673\"\u003evibrations;\u003c\/li\u003e\n\u003cli data-start=\"2674\" data-end=\"2691\"\u003erotor blockage;\u003c\/li\u003e\n\u003cli data-start=\"2692\" data-end=\"2710\"\u003ereduced airflow;\u003c\/li\u003e\n\u003cli data-start=\"2711\" data-end=\"2744\"\u003eincreased internal temperature;\u003c\/li\u003e\n\u003cli data-start=\"2745\" data-end=\"2797\"\u003eactivation of the equipment's thermal protections;\u003c\/li\u003e\n\u003cli data-start=\"2798\" data-end=\"2850\"\u003efan fault indication, when provided by the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2851\" data-end=\"2888\"\u003e\u003cspan role=\"text\"\u003e🚨 \u003cstrong data-start=\"2858\" data-end=\"2888\"\u003ePossible Associated Errors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2889\" data-end=\"3151\"\u003eThe error code depends on the equipment in which the fan is installed. A fan failure may generate indications such as \u003cstrong data-start=\"3007\" data-end=\"3069\"\u003eFan Fault, Fan Error, Over Temperature or Thermal Shutdown\u003c\/strong\u003e, but there is no universal error code directly associated with the MGT6012UB-W25.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"3152\" data-end=\"3172\"\u003e\u003cspan role=\"text\"\u003e🔍 \u003cstrong data-start=\"3159\" data-end=\"3172\"\u003eDiagnosis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3173\" data-end=\"3216\"\u003eFor verification, it is advisable to check:\u003c\/p\u003e\n\u003cul data-start=\"3217\" data-end=\"3443\"\u003e\n\u003cli data-start=\"3217\" data-end=\"3243\"\u003epresence of \u003cstrong data-start=\"3231\" data-end=\"3242\"\u003e12 V DC\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-start=\"3244\" data-end=\"3270\"\u003efan current consumption;\u003c\/li\u003e\n\u003cli data-start=\"3271\" data-end=\"3289\"\u003ecorrect startup;\u003c\/li\u003e\n\u003cli data-start=\"3290\" data-end=\"3307\"\u003erotation speed;\u003c\/li\u003e\n\u003cli data-start=\"3308\" data-end=\"3322\"\u003ePWM command;\u003c\/li\u003e\n\u003cli data-start=\"3323\" data-end=\"3353\"\u003epossible tachometric signal;\u003c\/li\u003e\n\u003cli data-start=\"3354\" data-end=\"3377\"\u003enoise and vibrations;\u003c\/li\u003e\n\u003cli data-start=\"3378\" data-end=\"3406\"\u003efreedom of rotor movement;\u003c\/li\u003e\n\u003cli data-start=\"3407\" data-end=\"3443\"\u003econdition of cables and connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3444\" data-end=\"3490\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3452\" data-end=\"3490\"\u003eCommon Services in Case of Failure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3491\" data-end=\"3669\"\u003e\n\u003cli data-start=\"3491\" data-end=\"3506\"\u003eFan cleaning.\u003c\/li\u003e\n\u003cli data-start=\"3507\" data-end=\"3527\"\u003eWiring inspection.\u003c\/li\u003e\n\u003cli data-start=\"3528\" data-end=\"3556\"\u003ePower supply verification.\u003c\/li\u003e\n\u003cli data-start=\"3557\" data-end=\"3592\"\u003eRotation and PWM control testing.\u003c\/li\u003e\n\u003cli data-start=\"3593\" data-end=\"3614\"\u003eBearing inspection.\u003c\/li\u003e\n\u003cli data-start=\"3615\" data-end=\"3669\"\u003eComplete fan replacement in case of wear or failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3670\" data-end=\"3694\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"3678\" data-end=\"3694\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3695\" data-end=\"3716\"\u003eSuitable for cooling:\u003c\/p\u003e\n\u003cul data-start=\"3717\" data-end=\"3895\"\u003e\n\u003cli data-start=\"3717\" data-end=\"3755\"\u003eelectronic inverters and converters;\u003c\/li\u003e\n\u003cli data-start=\"3756\" data-end=\"3783\"\u003eswitching power supplies;\u003c\/li\u003e\n\u003cli data-start=\"3784\" data-end=\"3811\"\u003eservers and workstations;\u003c\/li\u003e\n\u003cli data-start=\"3812\" data-end=\"3835\"\u003eindustrial equipment;\u003c\/li\u003e\n\u003cli data-start=\"3836\" data-end=\"3857\"\u003eautomation systems;\u003c\/li\u003e\n\u003cli data-start=\"3858\" data-end=\"3878\"\u003eelectronic panels;\u003c\/li\u003e\n\u003cli data-start=\"3879\" data-end=\"3895\"\u003epower devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"3896\" data-end=\"3917\"\u003e\u003cspan role=\"text\"\u003e💡 \u003cstrong data-start=\"3903\" data-end=\"3917\"\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3918\" data-end=\"4140\"\u003e\n\u003cli data-start=\"3918\" data-end=\"3955\"\u003eCompact \u003cstrong data-start=\"3928\" data-end=\"3947\"\u003e60 × 60 × 25 mm\u003c\/strong\u003e format.\u003c\/li\u003e\n\u003cli data-start=\"3956\" data-end=\"3978\"\u003eHigh rotation speed.\u003c\/li\u003e\n\u003cli data-start=\"3979\" data-end=\"4014\"\u003eGood airflow and static pressure.\u003c\/li\u003e\n\u003cli data-start=\"4015\" data-end=\"4051\"\u003eStandard \u003cstrong data-start=\"4026\" data-end=\"4037\"\u003e12 V DC\u003c\/strong\u003e power supply.\u003c\/li\u003e\n\u003cli data-start=\"4052\" data-end=\"4072\"\u003e4-wire connection.\u003c\/li\u003e\n\u003cli data-start=\"4073\" data-end=\"4087\"\u003ePWM control.\u003c\/li\u003e\n\u003cli data-start=\"4088\" data-end=\"4140\"\u003eBall bearings for continuous cooling applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4141\" data-end=\"4170\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"4149\" data-end=\"4170\"\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4171\" data-end=\"4410\"\u003e\u003cstrong data-start=\"4171\" data-end=\"4187\"\u003eUsed product\u003c\/strong\u003e, with normal signs of use as visible in the photograph.\u003cbr\u003eBefore installation, verify electrical and mechanical compatibility, paying particular attention to \u003cstrong data-start=\"4344\" data-end=\"4409\"\u003evoltage, connector, pinout, PWM control and airflow direction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"4411\" data-end=\"4438\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"4418\" data-end=\"4438\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4439\" data-end=\"4530\"\u003e\n\u003cli data-start=\"4439\" data-end=\"4530\"\u003e\n\u003cstrong data-start=\"4441\" data-end=\"4501\"\u003e1 × Protechnic MAGIC MGT6012UB-W25 fan – 12 V DC, 0.38 A\u003c\/strong\u003e, as shown in the photograph.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"4531\" data-end=\"4549\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"4538\" data-end=\"4549\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4550\" data-end=\"4931\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"4554\" data-end=\"4588\"\u003eProtechnic MAGIC MGT6012UB-W25\u003c\/strong\u003e is a \u003cstrong data-start=\"4594\" data-end=\"4605\"\u003e12 V DC\u003c\/strong\u003e axial fan, \u003cstrong data-start=\"4617\" data-end=\"4636\"\u003e60 × 60 × 25 mm\u003c\/strong\u003e, designed for cooling electronic equipment with high heat dissipation. It provides approximately \u003cstrong data-start=\"4734\" data-end=\"4747\"\u003e6,800 rpm\u003c\/strong\u003e, maximum airflow of \u003cstrong data-start=\"4768\" data-end=\"4780\"\u003e35.5 CFM\u003c\/strong\u003e and 4-wire PWM control. It is suitable as a replacement for inverters, power supplies and industrial equipment, subject to compatibility verification.\u003c\/p\u003e","brand":"Protechnic MAGIC axial fan","offers":[{"title":"Default Title","offer_id":54956005065037,"sku":null,"price":20.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7067.jpg?v=1791213200","url":"https:\/\/greenenergy-repair.com\/it\/products\/protechnic-magic-mgt6012ub-w25-12-v-dc-4-56-w","provider":"Green Energy","version":"1.0","type":"link"}