{"product_id":"phoenix-contact-valvetrab-val-ms-500-st-val-ms-be-fm-surge-protection-device-type-2-600-v-ac-30-ka","title":"Phoenix Contact VALVETRAB VAL-MS 500 ST + VAL-MS BE\/FM | Surge Protection Device Type 2 | 600 V AC | 30 kA |","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"9713cfb5-b6c1-4a55-a020-d3af03c16ed1\" data-testid=\"conversation-turn-12\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"9713cfb5-b6c1-4a55-a020-d3af03c16ed1\" dir=\"auto\" data-message-model-slug=\"gpt-5-2\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-start=\"42\" data-end=\"227\"\u003e\u003cstrong data-start=\"42\" data-end=\"85\"\u003ePhoenix Contact VALVETRAB VAL-MS 500 ST\u003c\/strong\u003e is a \u003cstrong data-start=\"91\" data-end=\"131\"\u003eType 2 Surge Protective Device (SPD)\u003c\/strong\u003e designed to protect electrical installations up to \u003cstrong data-start=\"183\" data-end=\"195\"\u003e600 V AC\u003c\/strong\u003e against transient overvoltages.\u003c\/p\u003e\n\u003cp data-start=\"229\" data-end=\"563\"\u003eThe device consists of the \u003cstrong data-start=\"256\" data-end=\"273\"\u003eVAL-MS 500 ST\u003c\/strong\u003e plug-in protection module and the \u003cstrong data-start=\"308\" data-end=\"324\"\u003eVAL-MS BE\/FM\u003c\/strong\u003e base, which includes a \u003cstrong data-start=\"348\" data-end=\"400\"\u003eremote signaling contact (FM – Fault Monitoring)\u003c\/strong\u003e for status monitoring. This feature enables remote supervision of the arrester’s operational state, making it ideal for installations requiring system monitoring.\u003c\/p\u003e\n\u003cp data-start=\"565\" data-end=\"793\"\u003eEngineered for \u003cstrong data-start=\"580\" data-end=\"601\"\u003eDIN rail mounting\u003c\/strong\u003e, this SPD provides effective protection against transient overvoltages caused by indirect lightning strikes and switching operations, safeguarding distribution boards and sensitive equipment.\u003c\/p\u003e\n\u003cp data-start=\"795\" data-end=\"1001\"\u003eThanks to its \u003cstrong data-start=\"809\" data-end=\"840\"\u003epluggable protection module\u003c\/strong\u003e, maintenance is quick and straightforward: in the event of activation, only the protection cartridge needs to be replaced without disconnecting the entire base.\u003c\/p\u003e\n\u003cp data-start=\"1003\" data-end=\"1213\"\u003eThe industrial-grade build quality of \u003cstrong data-start=\"1041\" data-end=\"1082\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003ePhoenix Contact\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e ensures reliability, compliance with international standards, and long operational life even in demanding industrial environments.\u003c\/p\u003e\n\u003chr data-start=\"1215\" data-end=\"1218\"\u003e\n\u003ch2 data-start=\"1220\" data-end=\"1257\"\u003e⚙️ Main Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1259\" data-end=\"1435\"\u003e\u003cstrong data-start=\"1259\" data-end=\"1276\"\u003eManufacturer:\u003c\/strong\u003e Phoenix Contact\u003cbr data-start=\"1292\" data-end=\"1295\"\u003e\u003cstrong data-start=\"1295\" data-end=\"1306\"\u003eSeries:\u003c\/strong\u003e VALVETRAB\u003cbr data-start=\"1316\" data-end=\"1319\"\u003e\u003cstrong data-start=\"1319\" data-end=\"1341\"\u003eProtection Module:\u003c\/strong\u003e VAL-MS 500 ST\u003cbr data-start=\"1355\" data-end=\"1358\"\u003e\u003cstrong data-start=\"1358\" data-end=\"1367\"\u003eBase:\u003c\/strong\u003e VAL-MS BE\/FM\u003cbr data-start=\"1380\" data-end=\"1383\"\u003e\u003cstrong data-start=\"1383\" data-end=\"1396\"\u003eSPD Type:\u003c\/strong\u003e Type 2 (T2)\u003cbr data-start=\"1408\" data-end=\"1411\"\u003e\u003cstrong data-start=\"1411\" data-end=\"1424\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003chr data-start=\"1437\" data-end=\"1440\"\u003e\n\u003ch3 data-start=\"1442\" data-end=\"1466\"\u003e🔌 Electrical Data\u003c\/h3\u003e\n\u003cul data-start=\"1468\" data-end=\"1721\"\u003e\n\u003cli data-start=\"1468\" data-end=\"1527\"\u003e\n\u003cp data-start=\"1470\" data-end=\"1527\"\u003eMaximum continuous operating voltage (Uc): \u003cstrong data-start=\"1513\" data-end=\"1525\"\u003e600 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1528\" data-end=\"1573\"\u003e\n\u003cp data-start=\"1530\" data-end=\"1573\"\u003eVoltage protection level (Up): \u003cstrong data-start=\"1561\" data-end=\"1571\"\u003e2.8 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1574\" data-end=\"1629\"\u003e\n\u003cp data-start=\"1576\" data-end=\"1629\"\u003eNominal discharge current (In): \u003cstrong data-start=\"1608\" data-end=\"1627\"\u003e15 kA (8\/20 μs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1630\" data-end=\"1687\"\u003e\n\u003cp data-start=\"1632\" data-end=\"1687\"\u003eMaximum discharge current (Imax): \u003cstrong data-start=\"1666\" data-end=\"1685\"\u003e30 kA (8\/20 μs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1688\" data-end=\"1721\"\u003e\n\u003cp data-start=\"1690\" data-end=\"1721\"\u003eCategory: \u003cstrong data-start=\"1700\" data-end=\"1719\"\u003eII \/ C (Type 2)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1723\" data-end=\"1726\"\u003e\n\u003ch2 data-start=\"1728\" data-end=\"1755\"\u003e🔔 Additional Features\u003c\/h2\u003e\n\u003cul data-start=\"1757\" data-end=\"1926\"\u003e\n\u003cli data-start=\"1757\" data-end=\"1796\"\u003e\n\u003cp data-start=\"1759\" data-end=\"1796\"\u003eRemote fault signaling contact (FM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1797\" data-end=\"1824\"\u003e\n\u003cp data-start=\"1799\" data-end=\"1824\"\u003eVisual status indicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1825\" data-end=\"1866\"\u003e\n\u003cp data-start=\"1827\" data-end=\"1866\"\u003ePlug-in replaceable protection module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1926\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1926\"\u003eRecommended backup fuse: up to \u003cstrong data-start=\"1900\" data-end=\"1912\"\u003e125 A gG\u003c\/strong\u003e (as marked)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1928\" data-end=\"1931\"\u003e\n\u003ch2 data-start=\"1933\" data-end=\"1955\"\u003e📜 Certifications\u003c\/h2\u003e\n\u003cul data-start=\"1957\" data-end=\"2003\"\u003e\n\u003cli data-start=\"1957\" data-end=\"1963\"\u003e\n\u003cp data-start=\"1959\" data-end=\"1963\"\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1964\" data-end=\"1981\"\u003e\n\u003cp data-start=\"1966\" data-end=\"1981\"\u003eUL Recognized\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"1995\"\u003e\n\u003cp data-start=\"1984\" data-end=\"1995\"\u003eKEMA-KEUR\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1996\" data-end=\"2003\"\u003e\n\u003cp data-start=\"1998\" data-end=\"2003\"\u003eOVE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2005\" data-end=\"2008\"\u003e\n\u003ch2 data-start=\"2010\" data-end=\"2030\"\u003e🔧 Key Features\u003c\/h2\u003e\n\u003cp data-start=\"2032\" data-end=\"2295\"\u003e✔️ Type 2 surge protection device\u003cbr data-start=\"2065\" data-end=\"2068\"\u003e✔️ Suitable for systems up to 600 V AC\u003cbr data-start=\"2106\" data-end=\"2109\"\u003e✔️ Maximum discharge current 30 kA\u003cbr data-start=\"2143\" data-end=\"2146\"\u003e✔️ Replaceable plug-in module\u003cbr data-start=\"2175\" data-end=\"2178\"\u003e✔️ Remote fault signaling contact (FM)\u003cbr data-start=\"2216\" data-end=\"2219\"\u003e✔️ Easy DIN rail installation\u003cbr data-start=\"2248\" data-end=\"2251\"\u003e✔️ Industrial-grade Phoenix Contact design\u003c\/p\u003e\n\u003chr data-start=\"2297\" data-end=\"2300\"\u003e\n\u003ch2 data-start=\"2302\" data-end=\"2328\"\u003e🔗 Ideal Applications\u003c\/h2\u003e\n\u003cp data-start=\"2330\" data-end=\"2546\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e✔️ Industrial electrical panels\u003cbr data-start=\"2361\" data-end=\"2364\"\u003e✔️ Power distribution systems\u003cbr data-start=\"2393\" data-end=\"2396\"\u003e✔️ AC-side photovoltaic installations\u003cbr data-start=\"2433\" data-end=\"2436\"\u003e✔️ Protection of machinery and sensitive electronics\u003cbr data-start=\"2488\" data-end=\"2491\"\u003e✔️ Installations requiring remote SPD status monitoring\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53419116167501,"sku":null,"price":50.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4837.jpg?v=1771926790","url":"https:\/\/greenenergy-repair.com\/it\/products\/phoenix-contact-valvetrab-val-ms-500-st-val-ms-be-fm-surge-protection-device-type-2-600-v-ac-30-ka","provider":"Green Energy","version":"1.0","type":"link"}