{"product_id":"used-regenerated-solarmax-35s-centralized-35ooow-35kw-photovoltaic-inverter","title":"SolarMax 35S 35kW Three-Phase Photovoltaic Inverter – 400VAC Industrial Grid-Tie Solar Inverter","description":"\u003ch1 data-start=\"0\" data-end=\"97\"\u003eSolarMax 35S 35kW Three-Phase Photovoltaic Inverter – 400VAC Industrial Grid-Tie Solar Inverter\u003c\/h1\u003e\n\u003ch2 data-start=\"99\" data-end=\"124\"\u003e📘 Product Description\u003c\/h2\u003e\n\u003cp data-start=\"126\" data-end=\"497\"\u003eThe \u003cstrong data-start=\"130\" data-end=\"146\"\u003eSolarMax 35S\u003c\/strong\u003e is a three-phase photovoltaic inverter designed for commercial and industrial solar power systems requiring reliable and efficient grid-connected energy conversion. Manufactured by \u003cstrong data-start=\"328\" data-end=\"354\"\u003eSputnik Engineering AG\u003c\/strong\u003e, this inverter converts the DC power generated by photovoltaic modules into three-phase AC power for direct connection to the electrical grid.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"769\"\u003eFeaturing a wide MPPT operating range, industrial-grade construction, and an IP54 protection rating, the SolarMax 35S is suitable for demanding photovoltaic installations in commercial buildings, industrial facilities, agricultural sites, and utility-scale applications.\u003c\/p\u003e\n\u003cp data-start=\"771\" data-end=\"928\"\u003eThe inverter includes an integrated LCD display for real-time monitoring, system diagnostics, operational status visualization, and configuration management.\u003c\/p\u003e\n\u003ch2 data-start=\"930\" data-end=\"960\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"962\" data-end=\"1454\"\u003e\n\u003cli data-start=\"962\" data-end=\"1000\"\u003eManufacturer: Sputnik Engineering AG\u003c\/li\u003e\n\u003cli data-start=\"1001\" data-end=\"1022\"\u003eModel: SolarMax 35S\u003c\/li\u003e\n\u003cli data-start=\"1023\" data-end=\"1082\"\u003eInverter Type: Three-Phase Grid-Tie Photovoltaic Inverter\u003c\/li\u003e\n\u003cli data-start=\"1083\" data-end=\"1113\"\u003eRated AC Output Power: 35 kW\u003c\/li\u003e\n\u003cli data-start=\"1114\" data-end=\"1150\"\u003eMaximum PV Generator Power: 45 kWp\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1183\"\u003eAC Output Voltage: 3 × 400 VAC\u003c\/li\u003e\n\u003cli data-start=\"1184\" data-end=\"1215\"\u003eRated AC Output Current: 54 A\u003c\/li\u003e\n\u003cli data-start=\"1216\" data-end=\"1239\"\u003eGrid Frequency: 50 Hz\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1275\"\u003eMaximum DC Input Voltage: 900 VDC\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1311\"\u003eMPPT Voltage Range: 400 – 800 VDC\u003c\/li\u003e\n\u003cli data-start=\"1312\" data-end=\"1337\"\u003eProtection Rating: IP54\u003c\/li\u003e\n\u003cli data-start=\"1338\" data-end=\"1377\"\u003eOperating Temperature: -20°C to +60°C\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1454\"\u003eApplication: Commercial and Industrial Grid-Connected Photovoltaic Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1456\" data-end=\"1475\"\u003e🔧 Main Features\u003c\/h2\u003e\n\u003cul data-start=\"1477\" data-end=\"1845\"\u003e\n\u003cli data-start=\"1477\" data-end=\"1517\"\u003eHigh-efficiency DC\/AC power conversion\u003c\/li\u003e\n\u003cli data-start=\"1518\" data-end=\"1556\"\u003eThree-phase grid-connected operation\u003c\/li\u003e\n\u003cli data-start=\"1557\" data-end=\"1582\"\u003eWide MPPT voltage range\u003c\/li\u003e\n\u003cli data-start=\"1583\" data-end=\"1618\"\u003eIntegrated LCD monitoring display\u003c\/li\u003e\n\u003cli data-start=\"1619\" data-end=\"1655\"\u003eAdvanced grid monitoring functions\u003c\/li\u003e\n\u003cli data-start=\"1656\" data-end=\"1695\"\u003eBuilt-in AC and DC protection systems\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1736\"\u003eEvent logging and diagnostic functions\u003c\/li\u003e\n\u003cli data-start=\"1737\" data-end=\"1787\"\u003eIndustrial-grade design for continuous operation\u003c\/li\u003e\n\u003cli data-start=\"1788\" data-end=\"1845\"\u003eSuitable for indoor and protected outdoor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1847\" data-end=\"1874\"\u003e🔌 Purpose and Operation\u003c\/h2\u003e\n\u003cp data-start=\"1876\" data-end=\"2042\"\u003eThe SolarMax 35S converts the direct current generated by photovoltaic panels into synchronized three-phase alternating current for export to the public utility grid.\u003c\/p\u003e\n\u003cp data-start=\"2044\" data-end=\"2247\"\u003eThe integrated MPPT system continuously tracks the maximum power point of the photovoltaic array, maximizing energy harvest and improving overall system efficiency under varying environmental conditions.\u003c\/p\u003e\n\u003ch2 data-start=\"2249\" data-end=\"2290\"\u003e🧩 Role Within the Photovoltaic System\u003c\/h2\u003e\n\u003cp data-start=\"2292\" data-end=\"2383\"\u003eThe inverter serves as the central energy conversion unit of the photovoltaic installation.\u003c\/p\u003e\n\u003cp data-start=\"2385\" data-end=\"2407\"\u003eIts functions include:\u003c\/p\u003e\n\u003cul data-start=\"2409\" data-end=\"2688\"\u003e\n\u003cli data-start=\"2409\" data-end=\"2466\"\u003eConverting DC solar energy into grid-compliant AC power\u003c\/li\u003e\n\u003cli data-start=\"2467\" data-end=\"2510\"\u003eMonitoring photovoltaic array performance\u003c\/li\u003e\n\u003cli data-start=\"2511\" data-end=\"2542\"\u003eManaging grid synchronization\u003c\/li\u003e\n\u003cli data-start=\"2543\" data-end=\"2592\"\u003eProtecting the system against electrical faults\u003c\/li\u003e\n\u003cli data-start=\"2593\" data-end=\"2632\"\u003eRecording operational data and alarms\u003c\/li\u003e\n\u003cli data-start=\"2633\" data-end=\"2688\"\u003eEnsuring compliance with grid connection requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2690\" data-end=\"2708\"\u003e🛠 Applications\u003c\/h2\u003e\n\u003cp data-start=\"2710\" data-end=\"2720\"\u003eIdeal for:\u003c\/p\u003e\n\u003cul data-start=\"2722\" data-end=\"2983\"\u003e\n\u003cli data-start=\"2722\" data-end=\"2755\"\u003eCommercial photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"2756\" data-end=\"2788\"\u003eIndustrial solar installations\u003c\/li\u003e\n\u003cli data-start=\"2789\" data-end=\"2816\"\u003eAgricultural solar plants\u003c\/li\u003e\n\u003cli data-start=\"2817\" data-end=\"2843\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli data-start=\"2844\" data-end=\"2881\"\u003eWarehouses and industrial buildings\u003c\/li\u003e\n\u003cli data-start=\"2882\" data-end=\"2909\"\u003eLarge commercial rooftops\u003c\/li\u003e\n\u003cli data-start=\"2910\" data-end=\"2949\"\u003eThree-phase grid-connected PV systems\u003c\/li\u003e\n\u003cli data-start=\"2950\" data-end=\"2983\"\u003eSolar power plants up to 45 kWp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2985\" data-end=\"3026\"\u003e🚨 Common Faults and Associated Errors\u003c\/h2\u003e\n\u003cp data-start=\"3028\" data-end=\"3077\"\u003eSolarMax inverters may experience faults such as:\u003c\/p\u003e\n\u003cul data-start=\"3079\" data-end=\"3362\"\u003e\n\u003cli data-start=\"3079\" data-end=\"3091\"\u003eGrid Fault\u003c\/li\u003e\n\u003cli data-start=\"3092\" data-end=\"3109\"\u003eIsolation Fault\u003c\/li\u003e\n\u003cli data-start=\"3110\" data-end=\"3124\"\u003eGround Fault\u003c\/li\u003e\n\u003cli data-start=\"3125\" data-end=\"3142\"\u003eOver Voltage DC\u003c\/li\u003e\n\u003cli data-start=\"3143\" data-end=\"3161\"\u003eUnder Voltage DC\u003c\/li\u003e\n\u003cli data-start=\"3162\" data-end=\"3180\"\u003eOver Temperature\u003c\/li\u003e\n\u003cli data-start=\"3181\" data-end=\"3192\"\u003eFan Fault\u003c\/li\u003e\n\u003cli data-start=\"3193\" data-end=\"3214\"\u003eCommunication Error\u003c\/li\u003e\n\u003cli data-start=\"3215\" data-end=\"3240\"\u003eInternal Hardware Error\u003c\/li\u003e\n\u003cli data-start=\"3241\" data-end=\"3261\"\u003eAC Frequency Error\u003c\/li\u003e\n\u003cli data-start=\"3262\" data-end=\"3280\"\u003eAC Voltage Error\u003c\/li\u003e\n\u003cli data-start=\"3281\" data-end=\"3302\"\u003eMPPT Tracking Fault\u003c\/li\u003e\n\u003cli data-start=\"3303\" data-end=\"3322\"\u003ePower Stage Fault\u003c\/li\u003e\n\u003cli data-start=\"3323\" data-end=\"3340\"\u003eStartup Failure\u003c\/li\u003e\n\u003cli data-start=\"3341\" data-end=\"3362\"\u003eInverter Stop Error\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3364\" data-end=\"3386\"\u003e🔍 Typical Symptoms\u003c\/h2\u003e\n\u003ch3 data-start=\"3388\" data-end=\"3416\"\u003eGrid Connection Problems\u003c\/h3\u003e\n\u003cp data-start=\"3418\" data-end=\"3427\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-start=\"3429\" data-end=\"3527\"\u003e❗ Inverter does not connect to the grid\u003cbr data-start=\"3468\" data-end=\"3471\"\u003e❗ Repeated startup attempts\u003cbr data-start=\"3498\" data-end=\"3501\"\u003e❗ Production interruptions\u003c\/p\u003e\n\u003ch3 data-start=\"3529\" data-end=\"3559\"\u003eOvertemperature Conditions\u003c\/h3\u003e\n\u003cp data-start=\"3561\" data-end=\"3570\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-start=\"3572\" data-end=\"3638\"\u003e❗ Reduced power output\u003cbr data-start=\"3594\" data-end=\"3597\"\u003e❗ Thermal derating\u003cbr data-start=\"3615\" data-end=\"3618\"\u003e❗ Automatic shutdown\u003c\/p\u003e\n\u003ch3 data-start=\"3640\" data-end=\"3664\"\u003eCommunication Faults\u003c\/h3\u003e\n\u003cp data-start=\"3666\" data-end=\"3675\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-start=\"3677\" data-end=\"3761\"\u003e❗ Missing monitoring data\u003cbr data-start=\"3702\" data-end=\"3705\"\u003e❗ Communication alarms\u003cbr data-start=\"3727\" data-end=\"3730\"\u003e❗ Remote monitoring unavailable\u003c\/p\u003e\n\u003ch3 data-start=\"3763\" data-end=\"3785\"\u003ePower Stage Issues\u003c\/h3\u003e\n\u003cp data-start=\"3787\" data-end=\"3796\"\u003eSymptoms:\u003c\/p\u003e\n\u003cp data-start=\"3798\" data-end=\"3871\"\u003e❗ No energy production\u003cbr data-start=\"3820\" data-end=\"3823\"\u003e❗ Hardware fault alarms\u003cbr data-start=\"3846\" data-end=\"3849\"\u003e❗ Unexpected shutdowns\u003c\/p\u003e\n\u003ch2 data-start=\"3873\" data-end=\"3888\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cul data-start=\"3890\" data-end=\"4169\"\u003e\n\u003cli data-start=\"3890\" data-end=\"3930\"\u003eProven SolarMax industrial reliability\u003c\/li\u003e\n\u003cli data-start=\"3931\" data-end=\"3959\"\u003eHigh conversion efficiency\u003c\/li\u003e\n\u003cli data-start=\"3960\" data-end=\"3987\"\u003eWide MPPT operating range\u003c\/li\u003e\n\u003cli data-start=\"3988\" data-end=\"4020\"\u003eRobust industrial construction\u003c\/li\u003e\n\u003cli data-start=\"4021\" data-end=\"4060\"\u003eIntegrated monitoring and diagnostics\u003c\/li\u003e\n\u003cli data-start=\"4061\" data-end=\"4110\"\u003eSuitable for demanding commercial installations\u003c\/li\u003e\n\u003cli data-start=\"4111\" data-end=\"4130\"\u003eLong service life\u003c\/li\u003e\n\u003cli data-start=\"4131\" data-end=\"4169\"\u003eEasy maintenance and troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4171\" data-end=\"4194\"\u003e📦 Product Condition\u003c\/h2\u003e\n\u003cp data-start=\"4196\" data-end=\"4289\"\u003eSolarMax 35S photovoltaic inverter complete with original housing and integrated LCD display.\u003c\/p\u003e\n\u003cp data-start=\"4291\" data-end=\"4303\"\u003eSuitable as:\u003c\/p\u003e\n\u003cul data-start=\"4305\" data-end=\"4471\"\u003e\n\u003cli data-start=\"4305\" data-end=\"4327\"\u003eReplacement inverter\u003c\/li\u003e\n\u003cli data-start=\"4328\" data-end=\"4356\"\u003eSpare unit for maintenance\u003c\/li\u003e\n\u003cli data-start=\"4357\" data-end=\"4392\"\u003eRepair and refurbishment projects\u003c\/li\u003e\n\u003cli data-start=\"4393\" data-end=\"4428\"\u003eExisting SolarMax system upgrades\u003c\/li\u003e\n\u003cli data-start=\"4429\" data-end=\"4471\"\u003eIndustrial photovoltaic system servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4473\" data-end=\"4486\"\u003e🟢 Summary\u003c\/h2\u003e\n\u003cp data-start=\"4488\" data-end=\"5012\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"4492\" data-end=\"4508\"\u003eSolarMax 35S\u003c\/strong\u003e is a \u003cstrong data-start=\"4514\" data-end=\"4566\"\u003e35kW three-phase grid-tied photovoltaic inverter\u003c\/strong\u003e designed for commercial and industrial solar installations. Featuring a \u003cstrong data-start=\"4639\" data-end=\"4656\"\u003e400VAC output\u003c\/strong\u003e, \u003cstrong data-start=\"4658\" data-end=\"4690\"\u003e900VDC maximum input voltage\u003c\/strong\u003e, \u003cstrong data-start=\"4692\" data-end=\"4711\"\u003ewide MPPT range\u003c\/strong\u003e, and \u003cstrong data-start=\"4717\" data-end=\"4747\"\u003eIP54 industrial protection\u003c\/strong\u003e, it provides reliable and efficient solar energy conversion for photovoltaic systems up to \u003cstrong data-start=\"4839\" data-end=\"4849\"\u003e45 kWp\u003c\/strong\u003e. Its integrated monitoring functions, robust construction, and proven SolarMax technology make it an excellent solution for professional solar power applications.\u003c\/p\u003e","brand":"solarmax inverter","offers":[{"title":"Default Title","offer_id":48344704909645,"sku":"","price":1000.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/5ac4081a-9354-463b-afee-4e779a2b6be0.png?v=1780677464","url":"https:\/\/greenenergy-repair.com\/es\/products\/used-regenerated-solarmax-35s-centralized-35ooow-35kw-photovoltaic-inverter","provider":"Green Energy","version":"1.0","type":"link"}