{"product_id":"thytronic-nv10h-a2-e-digital-protection-relay-advanced-protection-for-power-systems","title":"Thytronic PRO-N USB Protection Relay NV10P | 110–230 V AC\/DC | Ethernet + RS485 | IEC 61850","description":"\u003cp data-end=\"893\" data-start=\"556\"\u003eThe \u003cstrong data-end=\"579\" data-start=\"560\"\u003eThytronic NV10P\u003c\/strong\u003e is a high-precision \u003cstrong data-end=\"642\" data-start=\"600\"\u003evoltage and frequency protection relay\u003c\/strong\u003e engineered for power distribution, renewable energy, and grid-interconnection systems. Designed and manufactured in Italy, this model provides \u003cstrong data-end=\"845\" data-start=\"786\"\u003ecomprehensive protection, monitoring, and communication\u003c\/strong\u003e for three-phase networks and solar PV plants.\u003c\/p\u003e\n\u003cp data-end=\"1162\" data-start=\"895\"\u003eEquipped with \u003cstrong data-end=\"942\" data-start=\"909\"\u003eEthernet and RS485 interfaces\u003c\/strong\u003e, the NV10P supports \u003cstrong data-end=\"985\" data-start=\"963\"\u003eIEC 61850 protocol\u003c\/strong\u003e for seamless SCADA and automation integration. Its modular construction and intuitive 4×16 display ensure easy configuration, diagnostics, and real-time status visualization.\u003c\/p\u003e\n\u003cp data-end=\"1264\" data-start=\"1164\"\u003e🆕 \u003cstrong data-end=\"1181\" data-start=\"1167\"\u003eCondition:\u003c\/strong\u003e Brand New (factory sealed)\u003cbr data-end=\"1211\" data-start=\"1208\"\u003e🛠 \u003cstrong data-end=\"1227\" data-start=\"1214\"\u003eWarranty:\u003c\/strong\u003e 6 months provided by Green Energy\u003c\/p\u003e\n\u003cp data-end=\"1305\" data-start=\"1271\"\u003e⚙️ \u003cstrong data-end=\"1303\" data-start=\"1274\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"1337\" data-start=\"1309\"\u003e\n\u003cstrong data-end=\"1319\" data-start=\"1309\"\u003eModel:\u003c\/strong\u003e NV10P #JA2TE000\u003c\/li\u003e\n\u003cli data-end=\"1384\" data-start=\"1340\"\u003e\n\u003cstrong data-end=\"1357\" data-start=\"1340\"\u003eManufacturer:\u003c\/strong\u003e Thytronic S.p.A. (Italy)\u003c\/li\u003e\n\u003cli data-end=\"1439\" data-start=\"1387\"\u003e\n\u003cstrong data-end=\"1400\" data-start=\"1387\"\u003eFunction:\u003c\/strong\u003e Voltage \u0026amp; frequency protection relay\u003c\/li\u003e\n\u003cli data-end=\"1494\" data-start=\"1442\"\u003e\n\u003cstrong data-end=\"1476\" data-start=\"1442\"\u003eAuxiliary Power Supply (Uaux):\u003c\/strong\u003e 110–230 V AC\/DC\u003c\/li\u003e\n\u003cli data-end=\"1539\" data-start=\"1497\"\u003e\n\u003cstrong data-end=\"1528\" data-start=\"1497\"\u003eNominal Input Voltage (Un):\u003c\/strong\u003e 100 V AC\u003c\/li\u003e\n\u003cli data-end=\"1748\" data-start=\"1542\"\u003e\n\u003cstrong data-end=\"1567\" data-start=\"1542\"\u003eProtection Functions:\u003c\/strong\u003e\u003cbr data-end=\"1570\" data-start=\"1567\"\u003e27 – Undervoltage, 59 – Overvoltage, 59Umed – Average Voltage\u003cbr data-end=\"1636\" data-start=\"1633\"\u003e81U \/ O – Under\/Over Frequency, 81R – Rate of Change, BF – Breaker Failure, 74TCS – Trip Circuit Supervision\u003c\/li\u003e\n\u003cli data-end=\"1808\" data-start=\"1751\"\u003e\n\u003cstrong data-end=\"1763\" data-start=\"1751\"\u003eDisplay:\u003c\/strong\u003e 4×16 LCD, panel-mounted operator interface\u003c\/li\u003e\n\u003cli data-end=\"1866\" data-start=\"1811\"\u003e\n\u003cstrong data-end=\"1840\" data-start=\"1811\"\u003eCommunication Interfaces:\u003c\/strong\u003e Ethernet (RJ45) + RS485\u003c\/li\u003e\n\u003cli data-end=\"1907\" data-start=\"1869\"\u003e\n\u003cstrong data-end=\"1882\" data-start=\"1869\"\u003eProtocol:\u003c\/strong\u003e IEC 61850 \/ Modbus RTU\u003c\/li\u003e\n\u003cli data-end=\"1943\" data-start=\"1910\"\u003e\n\u003cstrong data-end=\"1923\" data-start=\"1910\"\u003eMounting:\u003c\/strong\u003e Flush panel mount\u003c\/li\u003e\n\u003cli data-end=\"1990\" data-start=\"1946\"\u003e\n\u003cstrong data-end=\"1972\" data-start=\"1946\"\u003eOperating Temperature:\u003c\/strong\u003e –25 °C … +60 °C\u003c\/li\u003e\n\u003cli data-end=\"2043\" data-start=\"1993\"\u003e\n\u003cstrong data-end=\"2008\" data-start=\"1993\"\u003eCompliance:\u003c\/strong\u003e CE certified, IEC 61850 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2072\" data-start=\"2050\"\u003e📌 \u003cstrong data-end=\"2070\" data-start=\"2053\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"2435\" data-start=\"2074\"\u003e✔️ Advanced voltage and frequency protection for grid-connected systems\u003cbr data-end=\"2148\" data-start=\"2145\"\u003e✔️ Supports IEC 61850 and Modbus RTU communication\u003cbr data-end=\"2201\" data-start=\"2198\"\u003e✔️ Dual communication ports – Ethernet + RS485\u003cbr data-end=\"2250\" data-start=\"2247\"\u003e✔️ Compact modular design with user-friendly display\u003cbr data-end=\"2305\" data-start=\"2302\"\u003e✔️ Certified for industrial and renewable energy applications\u003cbr data-end=\"2369\" data-start=\"2366\"\u003e✔️ Ideal for solar PV plants, microgrids and utility connections\u003c\/p\u003e\n\u003chr data-end=\"2440\" data-start=\"2437\"\u003e\n\u003cp data-end=\"2596\" data-start=\"2442\"\u003e🚀 \u003cstrong data-end=\"2594\" data-start=\"2445\"\u003eEnsure precise and reliable grid protection with the Thytronic NV10P — Italian-made, IEC 61850 certified, and supplied brand new by Green Energy.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thytronic S.p.A","offers":[{"title":"Default Title","offer_id":50576303456589,"sku":null,"price":1000.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/rn-image_picker_lib_temp_1cd79c36-b65b-47d3-bd6f-1dc26c084bf4.jpg?v=1761320411","url":"https:\/\/greenenergy-repair.com\/es\/products\/thytronic-nv10h-a2-e-digital-protection-relay-advanced-protection-for-power-systems","provider":"Green Energy","version":"1.0","type":"link"}