{"product_id":"sma-sunny-mini-ceentral-smc-7000hw-hw-7kw-single-phase-220v-used-tested","title":"SMA Sunny Mini Central SMC 7000HW HW 7kw Single Phase 220v","description":"\u003cp\u003eUsed. Green Energy company gives a 12 month guarantee \u003c\/p\u003e\n\u003ch2 data-start=\"110\" data-end=\"127\"\u003e1️⃣ Overview\u003c\/h2\u003e\n\u003cp data-start=\"128\" data-end=\"396\"\u003eThe \u003cstrong data-start=\"132\" data-end=\"169\"\u003eSMA Sunny Mini Central SMC 7000HW\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"192\" data-end=\"225\"\u003e7 kW single-phase PV inverter\u003c\/strong\u003e designed for commercial and small utility-scale solar systems. It converts DC power from solar modules into AC power suitable for grid connection at 220 V single-phase.\u003c\/p\u003e\n\u003cp data-start=\"398\" data-end=\"419\"\u003eKey features include:\u003c\/p\u003e\n\u003cul data-start=\"420\" data-end=\"614\"\u003e\n\u003cli data-start=\"420\" data-end=\"497\"\u003e\n\u003cp data-start=\"422\" data-end=\"497\"\u003eIntegrated Maximum Power Point Tracking (MPPT) for efficient energy harvest\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"498\" data-end=\"555\"\u003e\n\u003cp data-start=\"500\" data-end=\"555\"\u003eHigh efficiency and reliability for long-term operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"556\" data-end=\"614\"\u003e\n\u003cp data-start=\"558\" data-end=\"614\"\u003eGrid-compliant with European and international standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"621\" data-end=\"650\"\u003e2️⃣ Safety Instructions ⚠️\u003c\/h2\u003e\n\u003cul data-start=\"652\" data-end=\"1079\"\u003e\n\u003cli data-start=\"652\" data-end=\"730\"\u003e\n\u003cp data-start=\"654\" data-end=\"730\"\u003eInstallation and maintenance must be performed by \u003cstrong data-start=\"704\" data-end=\"727\"\u003equalified personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"731\" data-end=\"791\"\u003e\n\u003cp data-start=\"733\" data-end=\"791\"\u003eAlways disconnect \u003cstrong data-start=\"751\" data-end=\"771\"\u003eDC and AC supply\u003c\/strong\u003e before servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"792\" data-end=\"898\"\u003e\n\u003cp data-start=\"794\" data-end=\"898\"\u003eWait at least \u003cstrong data-start=\"808\" data-end=\"836\"\u003e5 minutes after shutdown\u003c\/strong\u003e before opening the inverter (capacitors may retain charge).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"899\" data-end=\"943\"\u003e\n\u003cp data-start=\"901\" data-end=\"943\"\u003eEnsure proper grounding (PE connection).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"944\" data-end=\"1022\"\u003e\n\u003cp data-start=\"946\" data-end=\"1022\"\u003eDo not operate in explosive, flammable, or excessively humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1023\" data-end=\"1079\"\u003e\n\u003cp data-start=\"1025\" data-end=\"1079\"\u003eFollow local electrical codes and utility regulations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1086\" data-end=\"1112\"\u003e3️⃣ System Requirements\u003c\/h2\u003e\n\u003cul data-start=\"1114\" data-end=\"1304\"\u003e\n\u003cli data-start=\"1114\" data-end=\"1155\"\u003e\n\u003cp data-start=\"1116\" data-end=\"1155\"\u003eSingle-phase 220 V AC grid connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1156\" data-end=\"1202\"\u003e\n\u003cp data-start=\"1158\" data-end=\"1202\"\u003ePV array voltage within inverter DC limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1203\" data-end=\"1263\"\u003e\n\u003cp data-start=\"1205\" data-end=\"1263\"\u003eAppropriate DC isolator and AC circuit breaker installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1264\" data-end=\"1304\"\u003e\n\u003cp data-start=\"1266\" data-end=\"1304\"\u003eAdequate ventilation around the unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1311\" data-end=\"1330\"\u003e4️⃣ Installation\u003c\/h2\u003e\n\u003ch3 data-start=\"1332\" data-end=\"1347\"\u003eA. Mounting\u003c\/h3\u003e\n\u003col data-start=\"1348\" data-end=\"1601\"\u003e\n\u003cli data-start=\"1348\" data-end=\"1429\"\u003e\n\u003cp data-start=\"1351\" data-end=\"1429\"\u003eSecure the inverter on a solid vertical wall or suitable mounting structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1526\"\u003e\n\u003cp data-start=\"1433\" data-end=\"1526\"\u003eMaintain recommended clearance (≈30 cm) around the unit for ventilation and service access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1527\" data-end=\"1601\"\u003e\n\u003cp data-start=\"1530\" data-end=\"1601\"\u003eEnsure stable environmental conditions (temperature, humidity, dust).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"1603\" data-end=\"1623\"\u003eB. DC Connection\u003c\/h3\u003e\n\u003col data-start=\"1624\" data-end=\"1813\"\u003e\n\u003cli data-start=\"1624\" data-end=\"1660\"\u003e\n\u003cp data-start=\"1627\" data-end=\"1660\"\u003eTurn off AC and DC disconnects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1661\" data-end=\"1742\"\u003e\n\u003cp data-start=\"1664\" data-end=\"1742\"\u003eConnect PV strings to the inverter DC terminals, observing correct polarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1743\" data-end=\"1813\"\u003e\n\u003cp data-start=\"1746\" data-end=\"1813\"\u003eEnsure that string voltages fall within the inverter's input range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"1815\" data-end=\"1835\"\u003eC. AC Connection\u003c\/h3\u003e\n\u003col data-start=\"1836\" data-end=\"2028\"\u003e\n\u003cli data-start=\"1836\" data-end=\"1888\"\u003e\n\u003cp data-start=\"1839\" data-end=\"1888\"\u003eConnect L (live), N (neutral), and PE (ground).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1889\" data-end=\"1956\"\u003e\n\u003cp data-start=\"1892\" data-end=\"1956\"\u003eVerify terminal torque according to manufacturer instructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1957\" data-end=\"2028\"\u003e\n\u003cp data-start=\"1960\" data-end=\"2028\"\u003eInstall a suitable AC protection device (circuit breaker or fuse).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2035\" data-end=\"2062\"\u003e5️⃣ Startup Procedure 🚀\u003c\/h2\u003e\n\u003col data-start=\"2064\" data-end=\"2300\"\u003e\n\u003cli data-start=\"2064\" data-end=\"2093\"\u003e\n\u003cp data-start=\"2067\" data-end=\"2093\"\u003eTurn on the DC isolator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2094\" data-end=\"2122\"\u003e\n\u003cp data-start=\"2097\" data-end=\"2122\"\u003eTurn on the AC breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2123\" data-end=\"2162\"\u003e\n\u003cp data-start=\"2126\" data-end=\"2162\"\u003eThe inverter performs a self-test.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2163\" data-end=\"2229\"\u003e\n\u003cp data-start=\"2166\" data-end=\"2229\"\u003eDisplay shows initialization → grid check → power production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2230\" data-end=\"2300\"\u003e\n\u003cp data-start=\"2233\" data-end=\"2300\"\u003eWhen grid parameters are verified, inverter begins feeding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2307\" data-end=\"2333\"\u003e6️⃣ Display \u0026amp; Operation\u003c\/h2\u003e\n\u003cp data-start=\"2335\" data-end=\"2363\"\u003eTypical display information:\u003c\/p\u003e\n\u003cul data-start=\"2364\" data-end=\"2522\"\u003e\n\u003cli data-start=\"2364\" data-end=\"2390\"\u003e\n\u003cp data-start=\"2366\" data-end=\"2390\"\u003ePV voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2391\" data-end=\"2424\"\u003e\n\u003cp data-start=\"2393\" data-end=\"2424\"\u003eAC output voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2425\" data-end=\"2454\"\u003e\n\u003cp data-start=\"2427\" data-end=\"2454\"\u003eActive and reactive power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2455\" data-end=\"2486\"\u003e\n\u003cp data-start=\"2457\" data-end=\"2486\"\u003eTotal energy produced (kWh)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2487\" data-end=\"2522\"\u003e\n\u003cp data-start=\"2489\" data-end=\"2522\"\u003eStatus messages and fault codes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2524\" data-end=\"2538\"\u003eButtons allow:\u003c\/p\u003e\n\u003cul data-start=\"2539\" data-end=\"2622\"\u003e\n\u003cli data-start=\"2539\" data-end=\"2564\"\u003e\n\u003cp data-start=\"2541\" data-end=\"2564\"\u003eViewing system status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2565\" data-end=\"2594\"\u003e\n\u003cp data-start=\"2567\" data-end=\"2594\"\u003eAccessing production data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2595\" data-end=\"2622\"\u003e\n\u003cp data-start=\"2597\" data-end=\"2622\"\u003eReviewing fault history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2629\" data-end=\"2662\"\u003e7️⃣ Monitoring \u0026amp; Communication\u003c\/h2\u003e\n\u003cp data-start=\"2664\" data-end=\"2710\"\u003eThe Sunny Mini Central SMC 7000HW may include:\u003c\/p\u003e\n\u003cul data-start=\"2711\" data-end=\"2904\"\u003e\n\u003cli data-start=\"2711\" data-end=\"2758\"\u003e\n\u003cp data-start=\"2713\" data-end=\"2758\"\u003eRS-485 interface for SMA data communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2759\" data-end=\"2828\"\u003e\n\u003cp data-start=\"2761\" data-end=\"2828\"\u003eOptional SMA WebConnect or Bluetooth module for remote monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2829\" data-end=\"2904\"\u003e\n\u003cp data-start=\"2831\" data-end=\"2904\"\u003eIntegration with SMA Sunny Portal for energy management and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2911\" data-end=\"2929\"\u003e8️⃣ Maintenance\u003c\/h2\u003e\n\u003cul data-start=\"2931\" data-end=\"3128\"\u003e\n\u003cli data-start=\"2931\" data-end=\"2999\"\u003e\n\u003cp data-start=\"2933\" data-end=\"2999\"\u003eInspect air inlets and outlets periodically (every 6–12 months).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3000\" data-end=\"3058\"\u003e\n\u003cp data-start=\"3002\" data-end=\"3058\"\u003eRemove dust using compressed air (do not use liquids).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3059\" data-end=\"3096\"\u003e\n\u003cp data-start=\"3061\" data-end=\"3096\"\u003eCheck cable connections annually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3097\" data-end=\"3128\"\u003e\n\u003cp data-start=\"3099\" data-end=\"3128\"\u003eReview fault log regularly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3130\" data-end=\"3172\"\u003eNo internal serviceable parts for users.\u003c\/p\u003e\n\u003ch2 data-start=\"3179\" data-end=\"3204\"\u003e9️⃣ Common Fault Codes\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3206\" data-end=\"3561\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3206\" data-end=\"3241\"\u003e\n\u003ctr data-start=\"3206\" data-end=\"3241\"\u003e\n\u003cth data-start=\"3206\" data-end=\"3214\" data-col-size=\"sm\" class=\"\"\u003eFault\u003c\/th\u003e\n\u003cth data-start=\"3214\" data-end=\"3231\" data-col-size=\"sm\" class=\"\"\u003ePossible Cause\u003c\/th\u003e\n\u003cth data-start=\"3231\" data-end=\"3241\" data-col-size=\"sm\" class=\"\"\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3278\" data-end=\"3561\"\u003e\n\u003ctr data-start=\"3278\" data-end=\"3345\"\u003e\n\u003ctd data-start=\"3278\" data-end=\"3291\" data-col-size=\"sm\"\u003eGrid Fault\u003c\/td\u003e\n\u003ctd data-start=\"3291\" data-end=\"3324\" data-col-size=\"sm\"\u003eVoltage\/frequency out of range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3324\" data-end=\"3345\"\u003eCheck grid supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3346\" data-end=\"3423\"\u003e\n\u003ctd data-start=\"3346\" data-end=\"3363\" data-col-size=\"sm\"\u003eDC Overvoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3363\" data-end=\"3392\"\u003ePV string voltage too high\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3392\" data-end=\"3423\"\u003eAdjust string configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3424\" data-end=\"3483\"\u003e\n\u003ctd data-start=\"3424\" data-end=\"3442\" data-col-size=\"sm\"\u003eIsolation Fault\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3442\" data-end=\"3462\"\u003eGrounding problem\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3462\" data-end=\"3483\"\u003eInspect PV wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3484\" data-end=\"3561\"\u003e\n\u003ctd data-start=\"3484\" data-end=\"3502\" data-col-size=\"sm\"\u003eOvertemperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3502\" data-end=\"3521\"\u003ePoor ventilation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3521\" data-end=\"3561\"\u003eImprove airflow or relocate inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3563\" data-end=\"3622\"\u003eIf errors persist, contact SMA-certified service personnel.\u003c\/p\u003e\n\u003ch2 data-start=\"3629\" data-end=\"3653\"\u003e🔟 Shutdown Procedure\u003c\/h2\u003e\n\u003col data-start=\"3655\" data-end=\"3763\"\u003e\n\u003cli data-start=\"3655\" data-end=\"3680\"\u003e\n\u003cp data-start=\"3658\" data-end=\"3680\"\u003eTurn off AC breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3681\" data-end=\"3707\"\u003e\n\u003cp data-start=\"3684\" data-end=\"3707\"\u003eTurn off DC isolator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3708\" data-end=\"3763\"\u003e\n\u003cp data-start=\"3711\" data-end=\"3763\"\u003eWait 5 minutes before any maintenance or inspection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"3770\" data-end=\"3791\"\u003eTechnical Summary\u003c\/h3\u003e\n\u003cul data-start=\"3793\" data-end=\"4077\"\u003e\n\u003cli data-start=\"3793\" data-end=\"3814\"\u003e\n\u003cp data-start=\"3795\" data-end=\"3814\"\u003eRated Power: 7 kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3815\" data-end=\"3880\"\u003e\n\u003cp data-start=\"3817\" data-end=\"3880\"\u003eInput: DC from PV modules (check nameplate for voltage range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3881\" data-end=\"3914\"\u003e\n\u003cp data-start=\"3883\" data-end=\"3914\"\u003eOutput: Single-phase 220 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3915\" data-end=\"3935\"\u003e\n\u003cp data-start=\"3917\" data-end=\"3935\"\u003eMPPT: Integrated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3936\" data-end=\"3974\"\u003e\n\u003cp data-start=\"3938\" data-end=\"3974\"\u003eProtection: IP65 (model dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3975\" data-end=\"4045\"\u003e\n\u003cp data-start=\"3977\" data-end=\"4045\"\u003eCooling: Natural convection or fan-assisted (depending on variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4046\" data-end=\"4077\"\u003e\n\u003cp data-start=\"4048\" data-end=\"4077\"\u003eCertifications: CE, UL, VDE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4079\" data-end=\"4082\"\u003e\n\u003cp data-start=\"4084\" data-end=\"4258\"\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"SMA INVERTER","offers":[{"title":"Default Title","offer_id":50247519994189,"sku":"","price":500.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/Screenshot-2024-09-26-17-08-09-35_260528048de7f2f358f0056f785be619.jpg?v=1727359773","url":"https:\/\/greenenergy-repair.com\/es\/products\/sma-sunny-mini-ceentral-smc-7000hw-hw-7kw-single-phase-220v-used-tested","provider":"Green Energy","version":"1.0","type":"link"}