{"product_id":"sma-sunny-boy-sb5000tl-21-5kw-single-phase-220v-new-sb-5000-tl","title":"SMA Sunny Boy SB5000TL-21 5kW 5000W Single Phase 2mppt 220VAC","description":"\u003cp\u003e\u003cspan\u003eNew. The official guarantee has expired. But the Green Energy company gives a 12 month guarantee \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"112\" data-end=\"129\"\u003e1️⃣ Overview\u003c\/h2\u003e\n\u003cp data-start=\"130\" data-end=\"422\"\u003eThe \u003cstrong data-start=\"134\" data-end=\"163\"\u003eSMA Sunny Boy SB5000TL-21\u003c\/strong\u003e is a \u003cstrong data-start=\"169\" data-end=\"221\"\u003e5 kW (5000 W) single-phase photovoltaic inverter\u003c\/strong\u003e with \u003cstrong data-start=\"227\" data-end=\"246\"\u003e2 MPPT channels\u003c\/strong\u003e, designed for residential and small commercial solar installations. It converts DC power from solar modules into AC power suitable for single-phase grid connection at 220 V.\u003c\/p\u003e\n\u003cp data-start=\"424\" data-end=\"439\"\u003eKey features:\u003c\/p\u003e\n\u003cul data-start=\"440\" data-end=\"758\"\u003e\n\u003cli data-start=\"440\" data-end=\"522\"\u003e\n\u003cp data-start=\"442\" data-end=\"522\"\u003eTwo independent Maximum Power Point Trackers (MPPT) for optimal energy harvest\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"523\" data-end=\"565\"\u003e\n\u003cp data-start=\"525\" data-end=\"565\"\u003eHigh efficiency and proven reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"566\" data-end=\"626\"\u003e\n\u003cp data-start=\"568\" data-end=\"626\"\u003eGrid-compliant with European and international standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"627\" data-end=\"691\"\u003e\n\u003cp data-start=\"629\" data-end=\"691\"\u003eAnti-islanding protection and advanced safety certifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eIdeal for rooftop PV systems with multiple string orientations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"760\" data-end=\"763\"\u003e\n\u003ch2 data-start=\"765\" data-end=\"794\"\u003e2️⃣ Safety Instructions ⚠️\u003c\/h2\u003e\n\u003cul data-start=\"796\" data-end=\"1281\"\u003e\n\u003cli data-start=\"796\" data-end=\"879\"\u003e\n\u003cp data-start=\"798\" data-end=\"879\"\u003eInstallation and maintenance must be performed by \u003cstrong data-start=\"848\" data-end=\"876\"\u003equalified personnel only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"880\" data-end=\"959\"\u003e\n\u003cp data-start=\"882\" data-end=\"959\"\u003eDisconnect \u003cstrong data-start=\"893\" data-end=\"913\"\u003eAC and DC supply\u003c\/strong\u003e before performing any work on the inverter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"960\" data-end=\"1063\"\u003e\n\u003cp data-start=\"962\" data-end=\"1063\"\u003eWait at least \u003cstrong data-start=\"976\" data-end=\"1004\"\u003e5 minutes after shutdown\u003c\/strong\u003e before opening the unit (capacitors may remain charged).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1108\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1108\"\u003eEnsure proper grounding (PE connection).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1109\" data-end=\"1187\"\u003e\n\u003cp data-start=\"1111\" data-end=\"1187\"\u003eDo not install in explosive, flammable, or excessively humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1281\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1281\"\u003eFollow all local electrical codes, utility requirements, and SMA installation guidelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1283\" data-end=\"1286\"\u003e\n\u003ch2 data-start=\"1288\" data-end=\"1314\"\u003e3️⃣ System Requirements\u003c\/h2\u003e\n\u003cul data-start=\"1316\" data-end=\"1536\"\u003e\n\u003cli data-start=\"1316\" data-end=\"1357\"\u003e\n\u003cp data-start=\"1318\" data-end=\"1357\"\u003eSingle-phase 220 V AC grid connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1358\" data-end=\"1410\"\u003e\n\u003cp data-start=\"1360\" data-end=\"1410\"\u003ePV array voltage within inverter DC input limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1411\" data-end=\"1491\"\u003e\n\u003cp data-start=\"1413\" data-end=\"1491\"\u003eDC isolator and AC circuit breaker installed according to safety regulations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1492\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1494\" data-end=\"1536\"\u003eAdequate ventilation around the inverter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1538\" data-end=\"1541\"\u003e\n\u003ch2 data-start=\"1543\" data-end=\"1562\"\u003e4️⃣ Installation\u003c\/h2\u003e\n\u003ch3 data-start=\"1564\" data-end=\"1579\"\u003eA. Mounting\u003c\/h3\u003e\n\u003col data-start=\"1580\" data-end=\"1810\"\u003e\n\u003cli data-start=\"1580\" data-end=\"1662\"\u003e\n\u003cp data-start=\"1583\" data-end=\"1662\"\u003eInstall the inverter on a solid vertical wall or suitable mounting structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1663\" data-end=\"1741\"\u003e\n\u003cp data-start=\"1666\" data-end=\"1741\"\u003eMaintain a minimum clearance (~30 cm) for ventilation and service access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1742\" data-end=\"1810\"\u003e\n\u003cp data-start=\"1745\" data-end=\"1810\"\u003eAvoid direct exposure to sunlight, rain, or excessive humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"1812\" data-end=\"1832\"\u003eB. DC Connection\u003c\/h3\u003e\n\u003col data-start=\"1833\" data-end=\"2018\"\u003e\n\u003cli data-start=\"1833\" data-end=\"1867\"\u003e\n\u003cp data-start=\"1836\" data-end=\"1867\"\u003eTurn off AC and DC isolators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1868\" data-end=\"1951\"\u003e\n\u003cp data-start=\"1871\" data-end=\"1951\"\u003eConnect PV strings to the two MPPT input channels, observing correct polarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1952\" data-end=\"2018\"\u003e\n\u003cp data-start=\"1955\" data-end=\"2018\"\u003eEnsure each string voltage is within the allowed input range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"2020\" data-end=\"2040\"\u003eC. AC Connection\u003c\/h3\u003e\n\u003col data-start=\"2041\" data-end=\"2230\"\u003e\n\u003cli data-start=\"2041\" data-end=\"2094\"\u003e\n\u003cp data-start=\"2044\" data-end=\"2094\"\u003eConnect L (phase), N (neutral), and PE (ground).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2095\" data-end=\"2156\"\u003e\n\u003cp data-start=\"2098\" data-end=\"2156\"\u003eTighten terminals according to the torque specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2157\" data-end=\"2230\"\u003e\n\u003cp data-start=\"2160\" data-end=\"2230\"\u003eInstall appropriate AC protection devices (circuit breaker or fuse).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"2232\" data-end=\"2235\"\u003e\n\u003ch2 data-start=\"2237\" data-end=\"2264\"\u003e5️⃣ Startup Procedure 🚀\u003c\/h2\u003e\n\u003col data-start=\"2266\" data-end=\"2514\"\u003e\n\u003cli data-start=\"2266\" data-end=\"2295\"\u003e\n\u003cp data-start=\"2269\" data-end=\"2295\"\u003eTurn on the DC isolator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2296\" data-end=\"2324\"\u003e\n\u003cp data-start=\"2299\" data-end=\"2324\"\u003eTurn on the AC breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2325\" data-end=\"2364\"\u003e\n\u003cp data-start=\"2328\" data-end=\"2364\"\u003eThe inverter performs a self-test.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2365\" data-end=\"2438\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2438\"\u003eDisplay shows initialization → grid verification → power production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2439\" data-end=\"2514\"\u003e\n\u003cp data-start=\"2442\" data-end=\"2514\"\u003eWhen grid conditions are confirmed, the inverter begins feeding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"2516\" data-end=\"2519\"\u003e\n\u003ch2 data-start=\"2521\" data-end=\"2547\"\u003e6️⃣ Display \u0026amp; Operation\u003c\/h2\u003e\n\u003cp data-start=\"2549\" data-end=\"2578\"\u003eThe inverter display shows:\u003c\/p\u003e\n\u003cul data-start=\"2579\" data-end=\"2750\"\u003e\n\u003cli data-start=\"2579\" data-end=\"2627\"\u003e\n\u003cp data-start=\"2581\" data-end=\"2627\"\u003ePV voltage and current for each MPPT channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2628\" data-end=\"2661\"\u003e\n\u003cp data-start=\"2630\" data-end=\"2661\"\u003eAC output voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2662\" data-end=\"2691\"\u003e\n\u003cp data-start=\"2664\" data-end=\"2691\"\u003eActive and reactive power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2692\" data-end=\"2723\"\u003e\n\u003cp data-start=\"2694\" data-end=\"2723\"\u003eTotal energy produced (kWh)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2724\" data-end=\"2750\"\u003e\n\u003cp data-start=\"2726\" data-end=\"2750\"\u003eStatus and fault codes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2752\" data-end=\"2779\"\u003eNavigation buttons allow:\u003c\/p\u003e\n\u003cul data-start=\"2780\" data-end=\"2863\"\u003e\n\u003cli data-start=\"2780\" data-end=\"2805\"\u003e\n\u003cp data-start=\"2782\" data-end=\"2805\"\u003eViewing system status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2806\" data-end=\"2835\"\u003e\n\u003cp data-start=\"2808\" data-end=\"2835\"\u003eAccessing production data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2836\" data-end=\"2863\"\u003e\n\u003cp data-start=\"2838\" data-end=\"2863\"\u003eReviewing fault history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2865\" data-end=\"2868\"\u003e\n\u003ch2 data-start=\"2870\" data-end=\"2903\"\u003e7️⃣ Monitoring \u0026amp; Communication\u003c\/h2\u003e\n\u003cp data-start=\"2905\" data-end=\"2932\"\u003eThe SB5000TL-21 supports:\u003c\/p\u003e\n\u003cul data-start=\"2933\" data-end=\"3150\"\u003e\n\u003cli data-start=\"2933\" data-end=\"3002\"\u003e\n\u003cp data-start=\"2935\" data-end=\"3002\"\u003eOptional SMA WebConnect or Bluetooth module for remote monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3003\" data-end=\"3077\"\u003e\n\u003cp data-start=\"3005\" data-end=\"3077\"\u003eRS-485 interface for integration with SMA data loggers or Sunny Portal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3078\" data-end=\"3150\"\u003e\n\u003cp data-start=\"3080\" data-end=\"3150\"\u003eRemote diagnostics, energy management, and multi-inverter monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3152\" data-end=\"3155\"\u003e\n\u003ch2 data-start=\"3157\" data-end=\"3175\"\u003e8️⃣ Maintenance\u003c\/h2\u003e\n\u003cul data-start=\"3177\" data-end=\"3367\"\u003e\n\u003cli data-start=\"3177\" data-end=\"3230\"\u003e\n\u003cp data-start=\"3179\" data-end=\"3230\"\u003eInspect air inlets and outlets every 6–12 months.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3231\" data-end=\"3292\"\u003e\n\u003cp data-start=\"3233\" data-end=\"3292\"\u003eClean dust using dry compressed air (do not use liquids).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3293\" data-end=\"3334\"\u003e\n\u003cp data-start=\"3295\" data-end=\"3334\"\u003eCheck AC and DC connections annually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3335\" data-end=\"3367\"\u003e\n\u003cp data-start=\"3337\" data-end=\"3367\"\u003eReview fault logs regularly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3369\" data-end=\"3415\"\u003eNo internal components are user-serviceable.\u003c\/p\u003e\n\u003chr data-start=\"3417\" data-end=\"3420\"\u003e\n\u003ch2 data-start=\"3422\" data-end=\"3447\"\u003e9️⃣ Common Fault Codes\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3449\" data-end=\"3805\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3449\" data-end=\"3484\"\u003e\n\u003ctr data-start=\"3449\" data-end=\"3484\"\u003e\n\u003cth data-start=\"3449\" data-end=\"3457\" data-col-size=\"sm\" class=\"\"\u003eFault\u003c\/th\u003e\n\u003cth data-start=\"3457\" data-end=\"3474\" data-col-size=\"sm\" class=\"\"\u003ePossible Cause\u003c\/th\u003e\n\u003cth data-start=\"3474\" data-end=\"3484\" data-col-size=\"sm\" class=\"\"\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3521\" data-end=\"3805\"\u003e\n\u003ctr data-start=\"3521\" data-end=\"3589\"\u003e\n\u003ctd data-start=\"3521\" data-end=\"3534\" data-col-size=\"sm\"\u003eGrid Fault\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3534\" data-end=\"3567\"\u003eVoltage\/frequency out of range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3567\" data-end=\"3589\"\u003eCheck utility grid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3590\" data-end=\"3667\"\u003e\n\u003ctd data-start=\"3590\" data-end=\"3607\" data-col-size=\"sm\"\u003eDC Overvoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3607\" data-end=\"3636\"\u003ePV string voltage too high\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3636\" data-end=\"3667\"\u003eAdjust string configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3668\" data-end=\"3727\"\u003e\n\u003ctd data-start=\"3668\" data-end=\"3686\" data-col-size=\"sm\"\u003eIsolation Fault\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3686\" data-end=\"3706\"\u003eGrounding problem\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3706\" data-end=\"3727\"\u003eInspect PV wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3728\" data-end=\"3805\"\u003e\n\u003ctd data-start=\"3728\" data-end=\"3746\" data-col-size=\"sm\"\u003eOvertemperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3746\" data-end=\"3765\"\u003ePoor ventilation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3765\" data-end=\"3805\"\u003eImprove airflow or relocate inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3807\" data-end=\"3868\"\u003eIf faults persist, contact SMA-certified service personnel.\u003c\/p\u003e\n\u003chr data-start=\"3870\" data-end=\"3873\"\u003e\n\u003ch2 data-start=\"3875\" data-end=\"3899\"\u003e🔟 Shutdown Procedure\u003c\/h2\u003e\n\u003col data-start=\"3901\" data-end=\"4025\"\u003e\n\u003cli data-start=\"3901\" data-end=\"3930\"\u003e\n\u003cp data-start=\"3904\" data-end=\"3930\"\u003eTurn off the AC breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3931\" data-end=\"3961\"\u003e\n\u003cp data-start=\"3934\" data-end=\"3961\"\u003eTurn off the DC isolator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3962\" data-end=\"4025\"\u003e\n\u003cp data-start=\"3965\" data-end=\"4025\"\u003eWait at least 5 minutes before performing any maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"4027\" data-end=\"4030\"\u003e\n\u003ch3 data-start=\"4032\" data-end=\"4053\"\u003eTechnical Summary\u003c\/h3\u003e\n\u003cul data-start=\"4055\" data-end=\"4357\"\u003e\n\u003cli data-start=\"4055\" data-end=\"4086\"\u003e\n\u003cp data-start=\"4057\" data-end=\"4086\"\u003eRated Power: 5000 W \/ 5 kVA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4087\" data-end=\"4119\"\u003e\n\u003cp data-start=\"4089\" data-end=\"4119\"\u003eMPPT Channels: 2 independent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4120\" data-end=\"4185\"\u003e\n\u003cp data-start=\"4122\" data-end=\"4185\"\u003eDC Input: from PV modules (check nameplate for voltage range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4186\" data-end=\"4219\"\u003e\n\u003cp data-start=\"4188\" data-end=\"4219\"\u003eAC Output: Single-phase 220 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4220\" data-end=\"4258\"\u003e\n\u003cp data-start=\"4222\" data-end=\"4258\"\u003eProtection: IP65 (model-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4259\" data-end=\"4325\"\u003e\n\u003cp data-start=\"4261\" data-end=\"4325\"\u003eCooling: Natural convection or fan-assisted depending on model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4326\" data-end=\"4357\"\u003e\n\u003cp data-start=\"4328\" data-end=\"4357\"\u003eCertifications: CE, UL, VDE \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMA INVERTER","offers":[{"title":"Default Title","offer_id":48321645740365,"sku":"","price":500.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/photo_2_2024-08-28_17-47-27.jpg?v=1724856519","url":"https:\/\/greenenergy-repair.com\/es\/products\/sma-sunny-boy-sb5000tl-21-5kw-single-phase-220v-new-sb-5000-tl","provider":"Green Energy","version":"1.0","type":"link"}