{"product_id":"siemens-1","title":"Siemens VL160 Circuit Breaker | 3-Pole | 160 A | 690 V AC | 3VL27 | ETU10M Trip Unit | Made in Germany","description":"\u003cp data-start=\"565\" data-end=\"989\"\u003eThe \u003cstrong data-start=\"569\" data-end=\"594\"\u003eSiemens VL160 (3VL27)\u003c\/strong\u003e is a 3-pole molded case circuit breaker (MCCB) designed for reliable protection and switching of electrical systems in industrial, commercial, and solar power applications.\u003cbr data-start=\"767\" data-end=\"770\"\u003eRated at \u003cstrong data-start=\"779\" data-end=\"788\"\u003e160 A\u003c\/strong\u003e and up to \u003cstrong data-start=\"799\" data-end=\"811\"\u003e690 V AC\u003c\/strong\u003e, this breaker provides dependable overload and short-circuit protection through the \u003cstrong data-start=\"896\" data-end=\"927\"\u003eETU10M adjustable trip unit\u003c\/strong\u003e, ensuring precision and safety under heavy load conditions.\u003c\/p\u003e\n\u003cp data-start=\"991\" data-end=\"1202\"\u003eBuilt in Germany under \u003cstrong data-start=\"1014\" data-end=\"1029\"\u003eIEC 60947-2\u003c\/strong\u003e standards, the VL160 series combines durability, compact design, and advanced protection — making it ideal for power distribution, inverter cabinets, and control systems.\u003c\/p\u003e\n\u003cp data-start=\"1204\" data-end=\"1304\"\u003e🔄 \u003cstrong data-start=\"1207\" data-end=\"1221\"\u003eCondition:\u003c\/strong\u003e Used\u003cbr data-start=\"1248\" data-end=\"1251\"\u003e🛠 \u003cstrong data-start=\"1254\" data-end=\"1267\"\u003eWarranty:\u003c\/strong\u003e 6 months provided by Green Energy\u003c\/p\u003e\n\u003cp data-start=\"1311\" data-end=\"1345\"\u003e⚙️ \u003cstrong data-start=\"1314\" data-end=\"1343\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1348\" data-end=\"1374\"\u003e\n\u003cstrong data-start=\"1348\" data-end=\"1358\"\u003eModel:\u003c\/strong\u003e VL160 \/ 3VL27\u003c\/li\u003e\n\u003cli data-start=\"1377\" data-end=\"1408\"\u003e\n\u003cstrong data-start=\"1377\" data-end=\"1400\"\u003eRated Current (In):\u003c\/strong\u003e 160 A\u003c\/li\u003e\n\u003cli data-start=\"1411\" data-end=\"1457\"\u003e\n\u003cstrong data-start=\"1411\" data-end=\"1446\"\u003eRated Operational Voltage (Ue):\u003c\/strong\u003e 690 V AC\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1502\"\u003e\n\u003cstrong data-start=\"1460\" data-end=\"1494\"\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e 800 V\u003c\/li\u003e\n\u003cli data-start=\"1505\" data-end=\"1549\"\u003e\n\u003cstrong data-start=\"1505\" data-end=\"1542\"\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 8 kV\u003c\/li\u003e\n\u003cli data-start=\"1552\" data-end=\"1582\"\u003e\u003cstrong data-start=\"1552\" data-end=\"1580\"\u003eBreaking Capacity (Icu):\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1587\" data-end=\"1602\"\u003e65 kA @ 240 V\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1622\"\u003e55 kA @ 415 V\u003c\/li\u003e\n\u003cli data-start=\"1627\" data-end=\"1642\"\u003e32 kA @ 690 V\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1698\"\u003e\n\u003cstrong data-start=\"1645\" data-end=\"1659\"\u003eTrip Unit:\u003c\/strong\u003e ETU10M (adjustable thermal-magnetic)\u003c\/li\u003e\n\u003cli data-start=\"1701\" data-end=\"1720\"\u003e\n\u003cstrong data-start=\"1701\" data-end=\"1711\"\u003ePoles:\u003c\/strong\u003e 3-pole\u003c\/li\u003e\n\u003cli data-start=\"1723\" data-end=\"1748\"\u003e\n\u003cstrong data-start=\"1723\" data-end=\"1737\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1751\" data-end=\"1780\"\u003e\n\u003cstrong data-start=\"1751\" data-end=\"1764\"\u003eMounting:\u003c\/strong\u003e Panel-mounted\u003c\/li\u003e\n\u003cli data-start=\"1783\" data-end=\"1834\"\u003e\n\u003cstrong data-start=\"1783\" data-end=\"1797\"\u003eStandards:\u003c\/strong\u003e IEC\/EN 60947-2, NEMA, CE Certified\u003c\/li\u003e\n\u003cli data-start=\"1837\" data-end=\"1869\"\u003e\n\u003cstrong data-start=\"1837\" data-end=\"1859\"\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1876\" data-end=\"2167\"\u003e📌 \u003cstrong data-start=\"1879\" data-end=\"1896\"\u003eKey Features:\u003c\/strong\u003e\u003cbr data-start=\"1896\" data-end=\"1899\"\u003e✔️ Industrial-grade MCCB for systems up to 690 V\u003cbr data-start=\"1947\" data-end=\"1950\"\u003e✔️ Adjustable ETU10M trip unit for precise protection\u003cbr data-start=\"2003\" data-end=\"2006\"\u003e✔️ High short-circuit breaking capacity (up to 65 kA)\u003cbr data-start=\"2059\" data-end=\"2062\"\u003e✔️ Compact and reliable Siemens construction\u003cbr data-start=\"2106\" data-end=\"2109\"\u003e✔️ Suitable for solar inverter cabinets and power panels\u003c\/p\u003e\n\u003cp data-start=\"2174\" data-end=\"2295\"\u003e🚀 \u003cstrong data-start=\"2177\" data-end=\"2295\"\u003eProtect your power or solar system with the original Siemens VL160 —  verified, and backed by Green Energy.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Siemens Circuit Breaker","offers":[{"title":"Default Title","offer_id":52665406226765,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/rn-image_picker_lib_temp_d5a4df56-9fee-4653-a18c-636e627f197d.jpg?v=1761670885","url":"https:\/\/greenenergy-repair.com\/es\/products\/siemens-1","provider":"Green Energy","version":"1.0","type":"link"}