{"product_id":"refurbished-board-for-abb-aurora-fimer-inverters-fix-errors-e019-e029-e031-e030-e023-e015-e021-e020-e013","title":"ABB Aurora Power-One 8kW \/ 10.0kW \/ 12.5kW Filter \u0026 Relay Board – PN 3G83 – Photovoltaic Inverter Module","description":"\u003cp data-start=\"288\" data-end=\"474\"\u003eThis is an original \u003cstrong data-start=\"308\" data-end=\"351\"\u003eABB \/ Power-One Aurora electronic board\u003c\/strong\u003e, designed for both \u003cstrong data-start=\"371\" data-end=\"426\"\u003esingle-phase and three-phase photovoltaic inverters\u003c\/strong\u003e in the \u003cstrong data-start=\"434\" data-end=\"473\"\u003e8.0 kW, 10.0 kW, and 12.5 kW series\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"476\" data-end=\"661\"\u003eThe module serves as the \u003cstrong data-start=\"501\" data-end=\"559\"\u003einterface between the inverter and the electrical grid\u003c\/strong\u003e, integrating advanced \u003cstrong data-start=\"582\" data-end=\"632\"\u003efiltering, protection, and switching functions\u003c\/strong\u003e through high-voltage relays.\u003c\/p\u003e\n\u003cp data-start=\"663\" data-end=\"794\"\u003eIdentified as a \u003cstrong data-start=\"679\" data-end=\"721\"\u003eFilter \u0026amp; Relay Board (PN 3G83 Pb-Free)\u003c\/strong\u003e, it is a key component for proper inverter operation on the \u003cstrong data-start=\"782\" data-end=\"793\"\u003eAC side\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"796\" data-end=\"799\"\u003e\n\u003ch3 data-start=\"801\" data-end=\"822\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"823\" data-end=\"1076\"\u003e\n\u003cli data-start=\"823\" data-end=\"859\"\u003eEMI\/RFI filtering on the AC line\u003c\/li\u003e\n\u003cli data-start=\"860\" data-end=\"914\"\u003eGrid connection\/disconnection via \u003cstrong data-start=\"896\" data-end=\"912\"\u003epower relays\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"915\" data-end=\"972\"\u003eOvervoltage protection (MOVs and protection circuits)\u003c\/li\u003e\n\u003cli data-start=\"973\" data-end=\"1025\"\u003eElectrical signal stabilization and conditioning\u003c\/li\u003e\n\u003cli data-start=\"1026\" data-end=\"1076\"\u003eInterface between inverter and grid (\u003cstrong data-start=\"1065\" data-end=\"1073\"\u003eGRID\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1078\" data-end=\"1081\"\u003e\n\u003ch3 data-start=\"1083\" data-end=\"1108\"\u003e🔌 Technical Features\u003c\/h3\u003e\n\u003cul data-start=\"1109\" data-end=\"1342\"\u003e\n\u003cli data-start=\"1109\" data-end=\"1140\"\u003ePCB Model: \u003cstrong data-start=\"1122\" data-end=\"1138\"\u003e3G83 Pb-Free\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1141\" data-end=\"1194\"\u003eCompatibility: \u003cstrong data-start=\"1158\" data-end=\"1192\"\u003eAurora inverters up to 12.5 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1195\" data-end=\"1241\"\u003eHigh-voltage relays (\u003cstrong data-start=\"1218\" data-end=\"1238\"\u003eup to ~800–850 V\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1288\"\u003eInductors and ferrite chokes for filtering\u003c\/li\u003e\n\u003cli data-start=\"1289\" data-end=\"1342\"\u003ePower capacitors and anti-interference components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1344\" data-end=\"1359\"\u003e\u003cstrong data-start=\"1344\" data-end=\"1359\"\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1360\" data-end=\"1421\"\u003e\n\u003cli data-start=\"1360\" data-end=\"1389\"\u003eDC Inputs (\u003cstrong data-start=\"1373\" data-end=\"1386\"\u003eIN1 \/ IN2\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1390\" data-end=\"1421\"\u003eGRID (AC output connection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1423\" data-end=\"1426\"\u003e\n\u003ch3 data-start=\"1428\" data-end=\"1459\"\u003e🔧 Key Components (Visible)\u003c\/h3\u003e\n\u003cul data-start=\"1460\" data-end=\"1655\"\u003e\n\u003cli data-start=\"1460\" data-end=\"1493\"\u003ePower relays (grid switching)\u003c\/li\u003e\n\u003cli data-start=\"1494\" data-end=\"1533\"\u003eToroidal copper inductors (filters)\u003c\/li\u003e\n\u003cli data-start=\"1534\" data-end=\"1579\"\u003eHigh-capacity film capacitors (blue\/grey)\u003c\/li\u003e\n\u003cli data-start=\"1580\" data-end=\"1612\"\u003eVaristors (surge protection)\u003c\/li\u003e\n\u003cli data-start=\"1613\" data-end=\"1655\"\u003eControl and safety electronic circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1657\" data-end=\"1660\"\u003e\n\u003ch3 data-start=\"1662\" data-end=\"1693\"\u003e🌐 Role within the Inverter\u003c\/h3\u003e\n\u003cp data-start=\"1694\" data-end=\"1730\"\u003eThis board performs a critical role:\u003c\/p\u003e\n\u003cul data-start=\"1731\" data-end=\"1878\"\u003e\n\u003cli data-start=\"1731\" data-end=\"1785\"\u003eEnsures \u003cstrong data-start=\"1741\" data-end=\"1783\"\u003esafe connection to the electrical grid\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1786\" data-end=\"1829\"\u003eFilters disturbances and harmonic noise\u003c\/li\u003e\n\u003cli data-start=\"1830\" data-end=\"1878\"\u003eProtects both inverter and electrical system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1880\" data-end=\"2031\"\u003eAurora inverters are based on a \u003cstrong data-start=\"1912\" data-end=\"1936\"\u003emodular architecture\u003c\/strong\u003e, where each board manages a specific function to improve reliability and simplify maintenance.\u003c\/p\u003e\n\u003chr data-start=\"2033\" data-end=\"2036\"\u003e\n\u003ch3 data-start=\"2038\" data-end=\"2068\"\u003e⚠️ Common Faults Addressed\u003c\/h3\u003e\n\u003cp data-start=\"2069\" data-end=\"2125\"\u003eThis board is often involved in inverter errors such as:\u003c\/p\u003e\n\u003cul data-start=\"2126\" data-end=\"2220\"\u003e\n\u003cli data-start=\"2126\" data-end=\"2141\"\u003eGrid faults\u003c\/li\u003e\n\u003cli data-start=\"2142\" data-end=\"2176\"\u003eRelay \/ synchronization errors\u003c\/li\u003e\n\u003cli data-start=\"2177\" data-end=\"2220\"\u003eError codes: \u003cstrong data-start=\"2192\" data-end=\"2218\"\u003eE013,E019,E020,E021,E023,E028,E031,W003,\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2222\" data-end=\"2225\"\u003e\n\u003ch3 data-start=\"2227\" data-end=\"2247\"\u003e🏭 Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"2248\" data-end=\"2358\"\u003e\n\u003cli data-start=\"2248\" data-end=\"2274\"\u003e\u003cstrong data-start=\"2250\" data-end=\"2272\"\u003eABB Aurora PVI-8.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2275\" data-end=\"2302\"\u003e\u003cstrong data-start=\"2277\" data-end=\"2300\"\u003eABB Aurora PVI-10.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2303\" data-end=\"2330\"\u003e\u003cstrong data-start=\"2305\" data-end=\"2328\"\u003eABB Aurora PVI-12.5\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2331\" data-end=\"2358\"\u003eVersions: \u003cstrong data-start=\"2343\" data-end=\"2356\"\u003eOUTD \/ TL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2360\" data-end=\"2363\"\u003e\n\u003ch3 data-start=\"2365\" data-end=\"2384\"\u003e📊 Applications\u003c\/h3\u003e\n\u003cul data-start=\"2385\" data-end=\"2507\"\u003e\n\u003cli data-start=\"2385\" data-end=\"2417\"\u003ePhotovoltaic inverter repair\u003c\/li\u003e\n\u003cli data-start=\"2418\" data-end=\"2450\"\u003eReplacement of faulty boards\u003c\/li\u003e\n\u003cli data-start=\"2451\" data-end=\"2507\"\u003eMaintenance of residential and industrial PV systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2509\" data-end=\"2512\"\u003e\n\u003ch3 data-start=\"2514\" data-end=\"2538\"\u003e📦 Product Condition\u003c\/h3\u003e\n\u003cul data-start=\"2539\" data-end=\"2631\"\u003e\n\u003cli data-start=\"2539\" data-end=\"2571\"\u003e\u003cstrong data-start=\"2541\" data-end=\"2569\"\u003eUsed \/ refurbished board\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2572\" data-end=\"2596\"\u003eTested (if verified)\u003c\/li\u003e\n\u003cli data-start=\"2597\" data-end=\"2631\"\u003eSold as a technical spare part\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB Aurora parts","offers":[{"title":"Default Title","offer_id":50921606676813,"sku":null,"price":350.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5314.jpg?v=1775836084","url":"https:\/\/greenenergy-repair.com\/es\/products\/refurbished-board-for-abb-aurora-fimer-inverters-fix-errors-e019-e029-e031-e030-e023-e015-e021-e020-e013","provider":"Green Energy","version":"1.0","type":"link"}