{"product_id":"photovoltaic-inverter-sma-sb5000tl-20-4600w-5000va","title":"PHOTOVOLTAIC INVERTER SMA SB5000TL-20 4600W\/5000VA","description":"\u003cp\u003eNew. The official guarantee has expired. But the Green Energy company gives a 12 month guarantee \u003c\/p\u003e\n\u003ch2 data-start=\"112\" data-end=\"129\"\u003e1️⃣ Overview\u003c\/h2\u003e\n\u003cp data-start=\"130\" data-end=\"453\"\u003eThe \u003cstrong data-start=\"134\" data-end=\"163\"\u003eSMA Sunny Boy SB5000TL-20\u003c\/strong\u003e is a \u003cstrong data-start=\"169\" data-end=\"204\"\u003egrid-tied photovoltaic inverter\u003c\/strong\u003e with a rated output of 4600 W (5 kVA) designed for residential and small commercial solar systems. It converts DC power from solar panels into AC power compatible with the utility grid (typically single-phase 230 V or 220 V depending on country).\u003c\/p\u003e\n\u003cp data-start=\"455\" data-end=\"470\"\u003eKey features:\u003c\/p\u003e\n\u003cul data-start=\"471\" data-end=\"754\"\u003e\n\u003cli data-start=\"471\" data-end=\"541\"\u003e\n\u003cp data-start=\"473\" data-end=\"541\"\u003eHigh-efficiency conversion with SMA's advanced inverter technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"542\" data-end=\"619\"\u003e\n\u003cp data-start=\"544\" data-end=\"619\"\u003eIntegrated Maximum Power Point Tracking (MPPT) for optimal energy harvest\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"620\" data-end=\"667\"\u003e\n\u003cp data-start=\"622\" data-end=\"667\"\u003eCompliant with international grid standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"668\" data-end=\"706\"\u003e\n\u003cp data-start=\"670\" data-end=\"706\"\u003eBuilt-in anti-islanding protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"707\" data-end=\"754\"\u003e\n\u003cp data-start=\"709\" data-end=\"754\"\u003eRobust and reliable for long-term operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"761\" data-end=\"790\"\u003e2️⃣ Safety Instructions ⚠️\u003c\/h2\u003e\n\u003cul data-start=\"792\" data-end=\"1257\"\u003e\n\u003cli data-start=\"792\" data-end=\"875\"\u003e\n\u003cp data-start=\"794\" data-end=\"875\"\u003eInstallation and maintenance must be performed by \u003cstrong data-start=\"844\" data-end=\"872\"\u003equalified personnel only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"876\" data-end=\"936\"\u003e\n\u003cp data-start=\"878\" data-end=\"936\"\u003eAlways disconnect \u003cstrong data-start=\"896\" data-end=\"916\"\u003eAC and DC supply\u003c\/strong\u003e before servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"937\" data-end=\"1044\"\u003e\n\u003cp data-start=\"939\" data-end=\"1044\"\u003eWait at least \u003cstrong data-start=\"953\" data-end=\"981\"\u003e5 minutes after shutdown\u003c\/strong\u003e before opening the inverter (capacitors may remain charged).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1045\" data-end=\"1089\"\u003e\n\u003cp data-start=\"1047\" data-end=\"1089\"\u003eEnsure proper grounding (PE connection).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1090\" data-end=\"1168\"\u003e\n\u003cp data-start=\"1092\" data-end=\"1168\"\u003eDo not install in explosive, flammable, or excessively humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1169\" data-end=\"1257\"\u003e\n\u003cp data-start=\"1171\" data-end=\"1257\"\u003eFollow local electrical codes, utility regulations, and SMA installation guidelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1264\" data-end=\"1290\"\u003e3️⃣ System Requirements\u003c\/h2\u003e\n\u003cul data-start=\"1292\" data-end=\"1528\"\u003e\n\u003cli data-start=\"1292\" data-end=\"1337\"\u003e\n\u003cp data-start=\"1294\" data-end=\"1337\"\u003eSingle-phase 220–230 V AC grid connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1338\" data-end=\"1402\"\u003e\n\u003cp data-start=\"1340\" data-end=\"1402\"\u003ePV array voltage and current within inverter DC input limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1403\" data-end=\"1483\"\u003e\n\u003cp data-start=\"1405\" data-end=\"1483\"\u003eDC isolator and AC circuit breaker installed according to safety regulations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1484\" data-end=\"1528\"\u003e\n\u003cp data-start=\"1486\" data-end=\"1528\"\u003eAdequate ventilation around the inverter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1535\" data-end=\"1554\"\u003e4️⃣ Installation\u003c\/h2\u003e\n\u003ch3 data-start=\"1556\" data-end=\"1571\"\u003eA. Mounting\u003c\/h3\u003e\n\u003col data-start=\"1572\" data-end=\"1798\"\u003e\n\u003cli data-start=\"1572\" data-end=\"1637\"\u003e\n\u003cp data-start=\"1575\" data-end=\"1637\"\u003eMount the inverter on a vertical wall or suitable structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1709\"\u003e\n\u003cp data-start=\"1641\" data-end=\"1709\"\u003eMaintain a minimum clearance (~30 cm) for airflow and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1798\"\u003e\n\u003cp data-start=\"1713\" data-end=\"1798\"\u003eAvoid exposure to direct sunlight, rain, or high humidity (unit may be IP65 rated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"1800\" data-end=\"1820\"\u003eB. DC Connection\u003c\/h3\u003e\n\u003col data-start=\"1821\" data-end=\"1995\"\u003e\n\u003cli data-start=\"1821\" data-end=\"1857\"\u003e\n\u003cp data-start=\"1824\" data-end=\"1857\"\u003eTurn off AC and DC disconnects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1858\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1861\" data-end=\"1925\"\u003eConnect PV strings to DC terminals (observe correct polarity).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1926\" data-end=\"1995\"\u003e\n\u003cp data-start=\"1929\" data-end=\"1995\"\u003eVerify that the DC voltage is within the inverter’s input range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"1997\" data-end=\"2017\"\u003eC. AC Connection\u003c\/h3\u003e\n\u003col data-start=\"2018\" data-end=\"2208\"\u003e\n\u003cli data-start=\"2018\" data-end=\"2071\"\u003e\n\u003cp data-start=\"2021\" data-end=\"2071\"\u003eConnect L (phase), N (neutral), and PE (ground).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2072\" data-end=\"2136\"\u003e\n\u003cp data-start=\"2075\" data-end=\"2136\"\u003eTighten connections according to the torque specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2137\" data-end=\"2208\"\u003e\n\u003cp data-start=\"2140\" data-end=\"2208\"\u003eInstall a suitable AC protection device (circuit breaker or fuse).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2215\" data-end=\"2242\"\u003e5️⃣ Startup Procedure 🚀\u003c\/h2\u003e\n\u003col data-start=\"2244\" data-end=\"2497\"\u003e\n\u003cli data-start=\"2244\" data-end=\"2273\"\u003e\n\u003cp data-start=\"2247\" data-end=\"2273\"\u003eTurn on the DC isolator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2274\" data-end=\"2302\"\u003e\n\u003cp data-start=\"2277\" data-end=\"2302\"\u003eTurn on the AC breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2303\" data-end=\"2355\"\u003e\n\u003cp data-start=\"2306\" data-end=\"2355\"\u003eInverter performs self-test and initialization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2356\" data-end=\"2427\"\u003e\n\u003cp data-start=\"2359\" data-end=\"2427\"\u003eDisplay shows system check → grid verification → power production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2428\" data-end=\"2497\"\u003e\n\u003cp data-start=\"2431\" data-end=\"2497\"\u003eWhen grid conditions are correct, inverter begins feeding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-start=\"2504\" data-end=\"2530\"\u003e6️⃣ Display \u0026amp; Operation\u003c\/h2\u003e\n\u003cp data-start=\"2532\" data-end=\"2559\"\u003eThe LCD display provides:\u003c\/p\u003e\n\u003cul data-start=\"2560\" data-end=\"2717\"\u003e\n\u003cli data-start=\"2560\" data-end=\"2586\"\u003e\n\u003cp data-start=\"2562\" data-end=\"2586\"\u003ePV voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2587\" data-end=\"2620\"\u003e\n\u003cp data-start=\"2589\" data-end=\"2620\"\u003eAC output voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2621\" data-end=\"2650\"\u003e\n\u003cp data-start=\"2623\" data-end=\"2650\"\u003eActive and reactive power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2651\" data-end=\"2676\"\u003e\n\u003cp data-start=\"2653\" data-end=\"2676\"\u003eEnergy produced (kWh)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2677\" data-end=\"2717\"\u003e\n\u003cp data-start=\"2679\" data-end=\"2717\"\u003eStatus indicators and fault messages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2719\" data-end=\"2746\"\u003eNavigation buttons allow:\u003c\/p\u003e\n\u003cul data-start=\"2747\" data-end=\"2830\"\u003e\n\u003cli data-start=\"2747\" data-end=\"2772\"\u003e\n\u003cp data-start=\"2749\" data-end=\"2772\"\u003eViewing system status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2773\" data-end=\"2802\"\u003e\n\u003cp data-start=\"2775\" data-end=\"2802\"\u003eAccessing production data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2803\" data-end=\"2830\"\u003e\n\u003cp data-start=\"2805\" data-end=\"2830\"\u003eReviewing fault history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2837\" data-end=\"2870\"\u003e7️⃣ Monitoring \u0026amp; Communication\u003c\/h2\u003e\n\u003cp data-start=\"2872\" data-end=\"2920\"\u003eDepending on the model, the inverter supports:\u003c\/p\u003e\n\u003cul data-start=\"2921\" data-end=\"3101\"\u003e\n\u003cli data-start=\"2921\" data-end=\"2981\"\u003e\n\u003cp data-start=\"2923\" data-end=\"2981\"\u003eSMA WebConnect or Bluetooth module for remote monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2982\" data-end=\"3056\"\u003e\n\u003cp data-start=\"2984\" data-end=\"3056\"\u003eRS-485 interface for integration with SMA data loggers or Sunny Portal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3057\" data-end=\"3101\"\u003e\n\u003cp data-start=\"3059\" data-end=\"3101\"\u003eRemote diagnostics and energy management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3108\" data-end=\"3126\"\u003e8️⃣ Maintenance\u003c\/h2\u003e\n\u003cul data-start=\"3128\" data-end=\"3319\"\u003e\n\u003cli data-start=\"3128\" data-end=\"3179\"\u003e\n\u003cp data-start=\"3130\" data-end=\"3179\"\u003eClean air inlets and outlets every 6–12 months.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3180\" data-end=\"3241\"\u003e\n\u003cp data-start=\"3182\" data-end=\"3241\"\u003eRemove dust with dry compressed air (do not use liquids).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3242\" data-end=\"3283\"\u003e\n\u003cp data-start=\"3244\" data-end=\"3283\"\u003eCheck AC and DC connections annually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3284\" data-end=\"3319\"\u003e\n\u003cp data-start=\"3286\" data-end=\"3319\"\u003eReview the error log regularly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3321\" data-end=\"3367\"\u003eNo internal components are user-serviceable.\u003c\/p\u003e\n\u003ch2 data-start=\"3374\" data-end=\"3399\"\u003e9️⃣ Common Fault Codes\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3401\" data-end=\"3758\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3401\" data-end=\"3436\"\u003e\n\u003ctr data-start=\"3401\" data-end=\"3436\"\u003e\n\u003cth data-start=\"3401\" data-end=\"3409\" data-col-size=\"sm\" class=\"\"\u003eFault\u003c\/th\u003e\n\u003cth data-start=\"3409\" data-end=\"3426\" data-col-size=\"sm\" class=\"\"\u003ePossible Cause\u003c\/th\u003e\n\u003cth data-start=\"3426\" data-end=\"3436\" data-col-size=\"sm\" class=\"\"\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3473\" data-end=\"3758\"\u003e\n\u003ctr data-start=\"3473\" data-end=\"3542\"\u003e\n\u003ctd data-start=\"3473\" data-end=\"3486\" data-col-size=\"sm\"\u003eGrid Fault\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3486\" data-end=\"3520\"\u003eVoltage\/frequency outside range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3520\" data-end=\"3542\"\u003eCheck utility grid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3543\" data-end=\"3620\"\u003e\n\u003ctd data-start=\"3543\" data-end=\"3560\" data-col-size=\"sm\"\u003eDC Overvoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3560\" data-end=\"3589\"\u003ePV string voltage too high\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3589\" data-end=\"3620\"\u003eAdjust string configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3621\" data-end=\"3680\"\u003e\n\u003ctd data-start=\"3621\" data-end=\"3639\" data-col-size=\"sm\"\u003eIsolation Fault\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3639\" data-end=\"3659\"\u003eGrounding problem\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3659\" data-end=\"3680\"\u003eInspect PV wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3681\" data-end=\"3758\"\u003e\n\u003ctd data-start=\"3681\" data-end=\"3699\" data-col-size=\"sm\"\u003eOvertemperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3699\" data-end=\"3718\"\u003ePoor ventilation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3718\" data-end=\"3758\"\u003eImprove airflow or relocate inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3760\" data-end=\"3820\"\u003eContact SMA-certified service personnel if faults persist.\u003c\/p\u003e\n\u003ch2 data-start=\"3827\" data-end=\"3851\"\u003e🔟 Shutdown Procedure\u003c\/h2\u003e\n\u003col data-start=\"3853\" data-end=\"3969\"\u003e\n\u003cli data-start=\"3853\" data-end=\"3878\"\u003e\n\u003cp data-start=\"3856\" data-end=\"3878\"\u003eTurn off AC breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3879\" data-end=\"3905\"\u003e\n\u003cp data-start=\"3882\" data-end=\"3905\"\u003eTurn off DC isolator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3906\" data-end=\"3969\"\u003e\n\u003cp data-start=\"3909\" data-end=\"3969\"\u003eWait at least 5 minutes before performing any maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-start=\"3976\" data-end=\"3997\"\u003eTechnical Summary\u003c\/h3\u003e\n\u003cul data-start=\"3999\" data-end=\"4296\"\u003e\n\u003cli data-start=\"3999\" data-end=\"4033\"\u003e\n\u003cp data-start=\"4001\" data-end=\"4033\"\u003eRated Output: 4600 W \/ 5000 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4034\" data-end=\"4099\"\u003e\n\u003cp data-start=\"4036\" data-end=\"4099\"\u003eInput: DC from PV modules (check nameplate for voltage range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4100\" data-end=\"4137\"\u003e\n\u003cp data-start=\"4102\" data-end=\"4137\"\u003eAC Output: Single-phase 220–230 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4138\" data-end=\"4158\"\u003e\n\u003cp data-start=\"4140\" data-end=\"4158\"\u003eMPPT: Integrated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4159\" data-end=\"4197\"\u003e\n\u003cp data-start=\"4161\" data-end=\"4197\"\u003eProtection: IP65 (model dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4198\" data-end=\"4264\"\u003e\n\u003cp data-start=\"4200\" data-end=\"4264\"\u003eCooling: Natural convection or fan-assisted depending on model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4265\" data-end=\"4296\"\u003e\n\u003cp data-start=\"4267\" data-end=\"4296\"\u003eCertifications: CE, UL, VDE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMA INVERTER","offers":[{"title":"Default Title","offer_id":50239952322893,"sku":"","price":470.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/IMG-20240925_162837_285.jpg?v=1727270945","url":"https:\/\/greenenergy-repair.com\/es\/products\/photovoltaic-inverter-sma-sb5000tl-20-4600w-5000va","provider":"Green Energy","version":"1.0","type":"link"}