{"product_id":"kostal-piko-5-5-dcs-display-communication-control-board-10038692-02-with-lcd-panel-for-photovoltaic-inverter","title":"KOSTAL PIKO 5.5 DCS Display, Communication \u0026 Control Board 10038692.02 with LCD Panel for Photovoltaic Inverter","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"a892d0ea-f347-457b-8197-f4ac8815eca4\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"a892d0ea-f347-457b-8197-f4ac8815eca4\" data-turn-id-container=\"a892d0ea-f347-457b-8197-f4ac8815eca4\" data-testid=\"conversation-turn-284\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"a892d0ea-f347-457b-8197-f4ac8815eca4\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"146\" data-end=\"422\"\u003eThe \u003cstrong data-start=\"150\" data-end=\"178\"\u003eKOSTAL Panel 10038692.02\u003c\/strong\u003e is a multifunction electronic board installed in \u003cstrong data-start=\"228\" data-end=\"274\"\u003eKOSTAL PIKO 5.5 DCS photovoltaic inverters\u003c\/strong\u003e. This module integrates the LCD display, user interface, communication circuitry, and several inverter monitoring functions into a single assembly.\u003c\/p\u003e\n\u003cp data-start=\"424\" data-end=\"778\"\u003eThe board enables real-time visualization of production data, configuration of operating parameters, and management of communications between the inverter, local networks, and remote monitoring systems. It serves as the primary access point for both users and service technicians during monitoring, diagnostics, maintenance, and configuration operations.\u003c\/p\u003e\n\u003chr data-start=\"780\" data-end=\"783\"\u003e\n\u003ch2 data-start=\"785\" data-end=\"815\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"817\" data-end=\"1421\"\u003e\n\u003cli data-start=\"817\" data-end=\"858\"\u003e\n\u003cstrong data-start=\"819\" data-end=\"836\"\u003eManufacturer:\u003c\/strong\u003e KOSTAL Solar Electric\u003c\/li\u003e\n\u003cli data-start=\"859\" data-end=\"911\"\u003e\n\u003cstrong data-start=\"861\" data-end=\"891\"\u003eCompatible Inverter Model:\u003c\/strong\u003e KOSTAL PIKO 5.5 DCS\u003c\/li\u003e\n\u003cli data-start=\"912\" data-end=\"948\"\u003e\n\u003cstrong data-start=\"914\" data-end=\"936\"\u003eBoard Part Number:\u003c\/strong\u003e 10038692.02\u003c\/li\u003e\n\u003cli data-start=\"949\" data-end=\"999\"\u003e\n\u003cstrong data-start=\"951\" data-end=\"960\"\u003eType:\u003c\/strong\u003e Display, Communication \u0026amp; Control Board\u003c\/li\u003e\n\u003cli data-start=\"1000\" data-end=\"1028\"\u003e\u003cstrong data-start=\"1002\" data-end=\"1028\"\u003eIntegrated LCD Display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1029\" data-end=\"1073\"\u003e\u003cstrong data-start=\"1031\" data-end=\"1073\"\u003eUser interface with navigation buttons\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1113\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1113\"\u003eIntegrated Ethernet communication\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1114\" data-end=\"1149\"\u003e\u003cstrong data-start=\"1116\" data-end=\"1149\"\u003eRS485 communication interface\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1150\" data-end=\"1176\"\u003e\u003cstrong data-start=\"1152\" data-end=\"1176\"\u003eAnalog input support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1177\" data-end=\"1216\"\u003e\u003cstrong data-start=\"1179\" data-end=\"1216\"\u003eS0 Input\/Output interface support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1217\" data-end=\"1269\"\u003e\u003cstrong data-start=\"1219\" data-end=\"1269\"\u003eBuilt-in data logging and monitoring functions\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1270\" data-end=\"1308\"\u003e\u003cstrong data-start=\"1272\" data-end=\"1308\"\u003ePowered directly by the inverter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1309\" data-end=\"1345\"\u003e\u003cstrong data-start=\"1311\" data-end=\"1345\"\u003eInternal inverter installation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1421\"\u003e\u003cstrong data-start=\"1348\" data-end=\"1421\"\u003eDedicated microcontroller-based monitoring and data management system\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1423\" data-end=\"1426\"\u003e\n\u003ch2 data-start=\"1428\" data-end=\"1448\"\u003e🔧 Main Functions\u003c\/h2\u003e\n\u003ch3 data-start=\"1450\" data-end=\"1480\"\u003eLCD Display and Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"1482\" data-end=\"1511\"\u003eProvides real-time access to:\u003c\/p\u003e\n\u003cul data-start=\"1513\" data-end=\"1732\"\u003e\n\u003cli data-start=\"1513\" data-end=\"1541\"\u003eInstantaneous power output\u003c\/li\u003e\n\u003cli data-start=\"1542\" data-end=\"1567\"\u003eDaily energy production\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1602\"\u003eTotal lifetime energy generation\u003c\/li\u003e\n\u003cli data-start=\"1603\" data-end=\"1628\"\u003eDC voltage measurements\u003c\/li\u003e\n\u003cli data-start=\"1629\" data-end=\"1654\"\u003eDC current measurements\u003c\/li\u003e\n\u003cli data-start=\"1655\" data-end=\"1675\"\u003eAC grid parameters\u003c\/li\u003e\n\u003cli data-start=\"1676\" data-end=\"1703\"\u003eInverter operating status\u003c\/li\u003e\n\u003cli data-start=\"1704\" data-end=\"1732\"\u003eWarning and fault messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1734\" data-end=\"1760\"\u003eInverter Configuration\u003c\/h3\u003e\n\u003cp data-start=\"1762\" data-end=\"1779\"\u003eAllows access to:\u003c\/p\u003e\n\u003cul data-start=\"1781\" data-end=\"1957\"\u003e\n\u003cli data-start=\"1781\" data-end=\"1796\"\u003eGrid settings\u003c\/li\u003e\n\u003cli data-start=\"1797\" data-end=\"1821\"\u003eEthernet configuration\u003c\/li\u003e\n\u003cli data-start=\"1822\" data-end=\"1852\"\u003eRS485 communication settings\u003c\/li\u003e\n\u003cli data-start=\"1853\" data-end=\"1882\"\u003eCountry-specific parameters\u003c\/li\u003e\n\u003cli data-start=\"1883\" data-end=\"1903\"\u003eMonitoring options\u003c\/li\u003e\n\u003cli data-start=\"1904\" data-end=\"1928\"\u003eRemote portal settings\u003c\/li\u003e\n\u003cli data-start=\"1929\" data-end=\"1957\"\u003eSystem configuration menus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1959\" data-end=\"1991\"\u003eCommunication and Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"1993\" data-end=\"2022\"\u003eHandles data transmission to:\u003c\/p\u003e\n\u003cul data-start=\"2024\" data-end=\"2132\"\u003e\n\u003cli data-start=\"2024\" data-end=\"2041\"\u003eLocal computers\u003c\/li\u003e\n\u003cli data-start=\"2042\" data-end=\"2059\"\u003eNetwork routers\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2087\"\u003eRemote monitoring portals\u003c\/li\u003e\n\u003cli data-start=\"2088\" data-end=\"2103\"\u003eSCADA systems\u003c\/li\u003e\n\u003cli data-start=\"2104\" data-end=\"2132\"\u003eEnergy management software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2134\" data-end=\"2151\"\u003eEvent Logging\u003c\/h3\u003e\n\u003cp data-start=\"2153\" data-end=\"2172\"\u003eStores and manages:\u003c\/p\u003e\n\u003cul data-start=\"2174\" data-end=\"2275\"\u003e\n\u003cli data-start=\"2174\" data-end=\"2189\"\u003eAlarm history\u003c\/li\u003e\n\u003cli data-start=\"2190\" data-end=\"2208\"\u003eOperational logs\u003c\/li\u003e\n\u003cli data-start=\"2209\" data-end=\"2236\"\u003eEnergy production records\u003c\/li\u003e\n\u003cli data-start=\"2237\" data-end=\"2250\"\u003eGrid events\u003c\/li\u003e\n\u003cli data-start=\"2251\" data-end=\"2275\"\u003eDiagnostic information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2277\" data-end=\"2280\"\u003e\n\u003ch2 data-start=\"2282\" data-end=\"2309\"\u003e🔌 Purpose and Operation\u003c\/h2\u003e\n\u003cp data-start=\"2311\" data-end=\"2410\"\u003eThis board functions as the inverter's \u003cstrong data-start=\"2350\" data-end=\"2383\"\u003eHuman Machine Interface (HMI)\u003c\/strong\u003e and communication gateway.\u003c\/p\u003e\n\u003cp data-start=\"2412\" data-end=\"2447\"\u003eIt allows users and technicians to:\u003c\/p\u003e\n\u003cul data-start=\"2449\" data-end=\"2674\"\u003e\n\u003cli data-start=\"2449\" data-end=\"2490\"\u003eMonitor photovoltaic system performance\u003c\/li\u003e\n\u003cli data-start=\"2491\" data-end=\"2517\"\u003eVerify energy production\u003c\/li\u003e\n\u003cli data-start=\"2518\" data-end=\"2552\"\u003eView alarms and fault conditions\u003c\/li\u003e\n\u003cli data-start=\"2553\" data-end=\"2582\"\u003eConfigure inverter settings\u003c\/li\u003e\n\u003cli data-start=\"2583\" data-end=\"2620\"\u003ePerform diagnostics and maintenance\u003c\/li\u003e\n\u003cli data-start=\"2621\" data-end=\"2674\"\u003eConnect the inverter to remote monitoring platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2676\" data-end=\"2815\"\u003eWithout this board, the inverter may continue operating but can become difficult or impossible to configure, monitor, or diagnose properly.\u003c\/p\u003e\n\u003chr data-start=\"2817\" data-end=\"2820\"\u003e\n\u003ch2 data-start=\"2822\" data-end=\"2852\"\u003e🧩 Role Within the Inverter\u003c\/h2\u003e\n\u003cp data-start=\"2854\" data-end=\"2912\"\u003eInside the \u003cstrong data-start=\"2865\" data-end=\"2888\"\u003eKOSTAL PIKO 5.5 DCS\u003c\/strong\u003e, the board operates as:\u003c\/p\u003e\n\u003cul data-start=\"2914\" data-end=\"3080\"\u003e\n\u003cli data-start=\"2914\" data-end=\"2933\"\u003eData display unit\u003c\/li\u003e\n\u003cli data-start=\"2934\" data-end=\"2959\"\u003eConfiguration interface\u003c\/li\u003e\n\u003cli data-start=\"2960\" data-end=\"2983\"\u003eCommunication gateway\u003c\/li\u003e\n\u003cli data-start=\"2984\" data-end=\"3003\"\u003eLocal data logger\u003c\/li\u003e\n\u003cli data-start=\"3004\" data-end=\"3029\"\u003eAlarm management system\u003c\/li\u003e\n\u003cli data-start=\"3030\" data-end=\"3080\"\u003eInterface between power electronics and the user\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3082\" data-end=\"3217\"\u003eIt receives information from the main control board and converts it into readable data on the LCD display and communication interfaces.\u003c\/p\u003e\n\u003chr data-start=\"3219\" data-end=\"3222\"\u003e\n\u003ch2 data-start=\"3224\" data-end=\"3257\"\u003e⚠️ Typical Faults and Symptoms\u003c\/h2\u003e\n\u003ch3 data-start=\"3259\" data-end=\"3286\"\u003eLCD Display Not Working\u003c\/h3\u003e\n\u003cp data-start=\"3288\" data-end=\"3304\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-start=\"3306\" data-end=\"3409\"\u003e\n\u003cli data-start=\"3306\" data-end=\"3334\"\u003eMissing board power supply\u003c\/li\u003e\n\u003cli data-start=\"3335\" data-end=\"3361\"\u003eFailed voltage regulator\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3385\"\u003eDamaged internal fuse\u003c\/li\u003e\n\u003cli data-start=\"3386\" data-end=\"3409\"\u003eDefective LCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3411\" data-end=\"3443\"\u003ePartial or Corrupted Display\u003c\/h3\u003e\n\u003cp data-start=\"3445\" data-end=\"3461\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-start=\"3463\" data-end=\"3535\"\u003e\n\u003cli data-start=\"3463\" data-end=\"3480\"\u003eLCD degradation\u003c\/li\u003e\n\u003cli data-start=\"3481\" data-end=\"3510\"\u003eLoose flat cable connection\u003c\/li\u003e\n\u003cli data-start=\"3511\" data-end=\"3535\"\u003eDisplay driver failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3537\" data-end=\"3571\"\u003eEthernet Communication Failure\u003c\/h3\u003e\n\u003cp data-start=\"3573\" data-end=\"3589\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-start=\"3591\" data-end=\"3668\"\u003e\n\u003cli data-start=\"3591\" data-end=\"3622\"\u003eDefective Ethernet controller\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3647\"\u003eDamaged RJ45 connector\u003c\/li\u003e\n\u003cli data-start=\"3648\" data-end=\"3668\"\u003eCorrupted firmware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3670\" data-end=\"3700\"\u003eRS485 Communication Errors\u003c\/h3\u003e\n\u003cp data-start=\"3702\" data-end=\"3718\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-start=\"3720\" data-end=\"3815\"\u003e\n\u003cli data-start=\"3720\" data-end=\"3759\"\u003eFaulty serial communication circuitry\u003c\/li\u003e\n\u003cli data-start=\"3760\" data-end=\"3785\"\u003eElectrical interference\u003c\/li\u003e\n\u003cli data-start=\"3786\" data-end=\"3815\"\u003eIncorrect bus configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3817\" data-end=\"3847\"\u003eRandom Freezing or Reboots\u003c\/h3\u003e\n\u003cp data-start=\"3849\" data-end=\"3865\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-start=\"3867\" data-end=\"3960\"\u003e\n\u003cli data-start=\"3867\" data-end=\"3887\"\u003eCorrupted firmware\u003c\/li\u003e\n\u003cli data-start=\"3888\" data-end=\"3911\"\u003eUnstable power supply\u003c\/li\u003e\n\u003cli data-start=\"3912\" data-end=\"3937\"\u003eMicrocontroller failure\u003c\/li\u003e\n\u003cli data-start=\"3938\" data-end=\"3960\"\u003eAging SMD components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3962\" data-end=\"3986\"\u003eData Logging Failure\u003c\/h3\u003e\n\u003cp data-start=\"3988\" data-end=\"4004\"\u003ePossible causes:\u003c\/p\u003e\n\u003cul data-start=\"4006\" data-end=\"4073\"\u003e\n\u003cli data-start=\"4006\" data-end=\"4029\"\u003eDamaged memory device\u003c\/li\u003e\n\u003cli data-start=\"4030\" data-end=\"4047\"\u003eSoftware errors\u003c\/li\u003e\n\u003cli data-start=\"4048\" data-end=\"4073\"\u003eData logger malfunction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4075\" data-end=\"4078\"\u003e\n\u003ch2 data-start=\"4080\" data-end=\"4112\"\u003e🚨 Possible Associated Errors\u003c\/h2\u003e\n\u003cp data-start=\"4114\" data-end=\"4147\"\u003eA malfunctioning board may cause:\u003c\/p\u003e\n\u003cul data-start=\"4149\" data-end=\"4466\"\u003e\n\u003cli data-start=\"4149\" data-end=\"4182\"\u003eMissing production data display\u003c\/li\u003e\n\u003cli data-start=\"4183\" data-end=\"4214\"\u003eEthernet communication errors\u003c\/li\u003e\n\u003cli data-start=\"4215\" data-end=\"4243\"\u003eRS485 communication faults\u003c\/li\u003e\n\u003cli data-start=\"4244\" data-end=\"4286\"\u003eFailure to connect to monitoring portals\u003c\/li\u003e\n\u003cli data-start=\"4287\" data-end=\"4315\"\u003eMissing production updates\u003c\/li\u003e\n\u003cli data-start=\"4316\" data-end=\"4336\"\u003eLoss of event logs\u003c\/li\u003e\n\u003cli data-start=\"4337\" data-end=\"4359\"\u003eConfiguration errors\u003c\/li\u003e\n\u003cli data-start=\"4360\" data-end=\"4386\"\u003eFrozen display interface\u003c\/li\u003e\n\u003cli data-start=\"4387\" data-end=\"4418\"\u003eContinuous interface restarts\u003c\/li\u003e\n\u003cli data-start=\"4419\" data-end=\"4466\"\u003eInability to read inverter status information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4468\" data-end=\"4606\"\u003eIn many cases, the inverter may continue producing energy while monitoring, configuration, and communication functions become unavailable.\u003c\/p\u003e\n\u003chr data-start=\"4608\" data-end=\"4611\"\u003e\n\u003ch2 data-start=\"4613\" data-end=\"4631\"\u003e🛠 Applications\u003c\/h2\u003e\n\u003cul data-start=\"4633\" data-end=\"4909\"\u003e\n\u003cli data-start=\"4633\" data-end=\"4674\"\u003eRepair of KOSTAL PIKO 5.5 DCS inverters\u003c\/li\u003e\n\u003cli data-start=\"4675\" data-end=\"4734\"\u003eReplacement of defective display and communication boards\u003c\/li\u003e\n\u003cli data-start=\"4735\" data-end=\"4772\"\u003eRestoration of monitoring functions\u003c\/li\u003e\n\u003cli data-start=\"4773\" data-end=\"4824\"\u003eRepair of Ethernet and RS485 communication faults\u003c\/li\u003e\n\u003cli data-start=\"4825\" data-end=\"4865\"\u003eInverter refurbishment and maintenance\u003c\/li\u003e\n\u003cli data-start=\"4866\" data-end=\"4909\"\u003eTroubleshooting and diagnostic operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4911\" data-end=\"4914\"\u003e\n\u003ch2 data-start=\"4916\" data-end=\"4932\"\u003e💡 Advantages\u003c\/h2\u003e\n\u003cp data-start=\"4934\" data-end=\"5215\"\u003e✔ Original KOSTAL component\u003cbr data-start=\"4961\" data-end=\"4964\"\u003e✔ Integrated LCD display and communication functions\u003cbr data-start=\"5016\" data-end=\"5019\"\u003e✔ Supports local and remote monitoring\u003cbr data-start=\"5057\" data-end=\"5060\"\u003e✔ Enables inverter configuration and diagnostics\u003cbr data-start=\"5108\" data-end=\"5111\"\u003e✔ Built-in data logging capabilities\u003cbr data-start=\"5147\" data-end=\"5150\"\u003e✔ Cost-effective repair solution compared to inverter replacement\u003c\/p\u003e\n\u003chr data-start=\"5217\" data-end=\"5220\"\u003e\n\u003ch2 data-start=\"5222\" data-end=\"5235\"\u003e🟢 Summary\u003c\/h2\u003e\n\u003cp data-start=\"5237\" data-end=\"5678\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"5241\" data-end=\"5282\"\u003eKOSTAL PIKO 5.5 DCS Panel 10038692.02\u003c\/strong\u003e is the original display, communication, and control board used in KOSTAL photovoltaic inverters. Featuring an integrated LCD display, Ethernet and RS485 connectivity, user interface controls, and data logging functions, it serves as the central monitoring and communication hub of the inverter, providing essential functionality for operation, configuration, diagnostics, and remote supervision.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":54026381230413,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6000.jpg?v=1780498984","url":"https:\/\/greenenergy-repair.com\/es\/products\/kostal-piko-5-5-dcs-display-communication-control-board-10038692-02-with-lcd-panel-for-photovoltaic-inverter","provider":"Green Energy","version":"1.0","type":"link"}