{"product_id":"abb-sace-tmax-t4d-250-250-a-690-v-with-yo-shunt-trip-24-30-v-ac-dc","title":"ABB SACE Tmax T4D 250 Power Circuit Breaker | 3-Pole | 250 A | 690 V AC | YO Shunt Trip 24–30 V AC\/DC | MCCB | IEC 60947","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eUsed product.\u003c\/strong\u003e The \u003cstrong\u003eABB SACE Tmax T4D 250\u003c\/strong\u003e is a \u003cstrong\u003emolded-case circuit breaker (MCCB)\u003c\/strong\u003e designed for industrial applications and electrical power systems, with a \u003cstrong\u003erated current of 250 A\u003c\/strong\u003e and a rated operational voltage of up to \u003cstrong\u003e690 V AC\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe device is equipped with a \u003cstrong\u003eYO shunt trip\u003c\/strong\u003e, with a control voltage of \u003cstrong\u003e24–30 V AC or 24–30 V DC\u003c\/strong\u003e, allowing the circuit breaker to be opened by means of a remote electrical command.\u003c\/p\u003e\n\u003cp\u003eThe component shows normal \u003cstrong\u003esigns of previous use\u003c\/strong\u003e, including light abrasions and superficial marks on the external surfaces and hardware. The \u003cstrong\u003econtrol wiring connected to the YO shunt trip\u003c\/strong\u003e is also present, as shown in the photographs.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003eSACE Tmax\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eT4D 250\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e \u003cstrong\u003eMolded-Case Circuit Breaker (MCCB)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e \u003cstrong\u003e250 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage Ue:\u003c\/strong\u003e up to \u003cstrong\u003e690 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage Ui:\u003c\/strong\u003e \u003cstrong\u003e800 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Withstand Voltage Uimp:\u003c\/strong\u003e \u003cstrong\u003e8 kV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e \u003cstrong\u003eIEC 60947-3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Utilization Category:\u003c\/strong\u003e \u003cstrong\u003eAC-23A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e \u003cstrong\u003e50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e \u003cstrong\u003e250 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShunt Trip:\u003c\/strong\u003e \u003cstrong\u003eYO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYO Voltage:\u003c\/strong\u003e \u003cstrong\u003e24–30 V AC, 50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYO DC Voltage:\u003c\/strong\u003e \u003cstrong\u003e24–30 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e ABB SACE Tmax equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicated Origin:\u003c\/strong\u003e \u003cstrong\u003eMade in Italy\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe nameplate also indicates configurations for \u003cstrong\u003eDC applications\u003c\/strong\u003e, including \u003cstrong\u003eDC23A\u003c\/strong\u003e and connection of \u003cstrong\u003e2 poles in series\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong\u003eFunction in the Electrical System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTmax T4D 250\u003c\/strong\u003e is used for the \u003cstrong\u003eprotection and interruption of electrical power circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe circuit breaker allows the user to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterrupt the circuit under abnormal conditions covered by the protection system\u003c\/li\u003e\n\u003cli\u003eManually open and close the circuit\u003c\/li\u003e\n\u003cli\u003eIntegrate \u003cstrong\u003eremote control and tripping systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eIsolate electrical circuits during maintenance operations\u003c\/li\u003e\n\u003cli\u003eProtect lines and electrical equipment designed for currents up to \u003cstrong\u003e250 A\u003c\/strong\u003e, according to the specific system configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eYO shunt trip\u003c\/strong\u003e allows the circuit breaker to be electrically opened through an external control circuit operating at \u003cstrong\u003e24–30 V AC\/DC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🏭 \u003cstrong\u003eConstruction \u0026amp; Installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe device features the typical compact construction of the \u003cstrong\u003eABB SACE Tmax\u003c\/strong\u003e family, with a high-strength insulating body and front \u003cstrong\u003eON\/OFF\u003c\/strong\u003e operating mechanism.\u003c\/p\u003e\n\u003cp\u003eThe assembly also includes the connections associated with the \u003cstrong\u003eYO shunt trip\u003c\/strong\u003e, with external control wiring visible in the photographs.\u003c\/p\u003e\n\u003cp\u003eInstallation must be carried out by qualified personnel, with prior verification of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eRated current of the circuit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOperating voltage\u003c\/li\u003e\n\u003cli\u003eConnection diagram\u003c\/li\u003e\n\u003cli\u003eConductor sizing\u003c\/li\u003e\n\u003cli\u003eRequired breaking capacity of the electrical system\u003c\/li\u003e\n\u003cli\u003eCorrect power supply for the \u003cstrong\u003e24–30 V AC\/DC YO shunt trip\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🌐 \u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB SACE Tmax T4D 250\u003c\/strong\u003e is suitable for \u003cstrong\u003eindustrial electrical distribution and automation applications\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial electrical panels\u003c\/li\u003e\n\u003cli\u003eLow-voltage distribution\u003c\/li\u003e\n\u003cli\u003eLine and load protection\u003c\/li\u003e\n\u003cli\u003eAutomation systems\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery\u003c\/li\u003e\n\u003cli\u003eControl systems with \u003cstrong\u003eremote tripping\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical systems requiring electrically commanded remote opening\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThanks to the \u003cstrong\u003eYO shunt trip\u003c\/strong\u003e, it can be integrated into systems where the circuit breaker must be opened through a \u003cstrong\u003eremote electrical command\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e💡 \u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e250 A rated current\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOperational voltage up to \u003cstrong\u003e690 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUi 800 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUimp 8 kV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIndustrial \u003cstrong\u003eABB SACE Tmax\u003c\/strong\u003e construction\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eYO shunt trip\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eYO control voltage \u003cstrong\u003e24–30 V AC\/DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote tripping\u003c\/strong\u003e capability\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003eAC and DC applications\u003c\/strong\u003e according to the specified configuration\u003c\/li\u003e\n\u003cli\u003eRobust construction for use in industrial electrical panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong\u003eSafety \u0026amp; Product Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e⚠️ \u003cstrong\u003eWARNING: EQUIPMENT INTENDED FOR ELECTRICAL POWER CIRCUITS.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe circuit breaker must be installed and tested exclusively by \u003cstrong\u003equalified personnel\u003c\/strong\u003e, in accordance with the characteristics of the electrical system and applicable safety requirements.\u003c\/p\u003e\n\u003cp\u003eThe component is \u003cstrong\u003eused\u003c\/strong\u003e and shows signs of previous installation, mainly on the external surfaces, terminals, and hardware.\u003c\/p\u003e\n\u003cp\u003eThe correct operation of the \u003cstrong\u003emain contacts, opening\/closing mechanism, and YO shunt trip\u003c\/strong\u003e cannot be certified from the photographs alone. Before selling it as a fully functional component, a complete mechanical and electrical inspection is therefore recommended, including a \u003cstrong\u003e24–30 V AC\/DC shunt-trip test\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1 × ABB SACE Tmax T4D 250\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 × YO Shunt Trip 24–30 V AC\/DC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl wiring present\u003c\/strong\u003e, as shown in the photographs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🚀 \u003cstrong\u003eFinal Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB SACE Tmax T4D 250\u003c\/strong\u003e is a \u003cstrong\u003e250 A molded-case circuit breaker\u003c\/strong\u003e, designed for industrial electrical distribution and protection applications with voltages up to \u003cstrong\u003e690 V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe presence of the \u003cstrong\u003e24–30 V AC\/DC YO shunt trip\u003c\/strong\u003e makes it particularly interesting as a replacement component for industrial electrical panels and systems requiring the possibility of \u003cstrong\u003eelectrically controlled remote opening\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe component is offered as \u003cstrong\u003eused\u003c\/strong\u003e, with normal signs of previous installation. For sale as a fully operational device, a \u003cstrong\u003efunctional test of the operating mechanism and YO shunt trip\u003c\/strong\u003e is recommended.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":54649256968525,"sku":null,"price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6649.jpg?v=1788452827","url":"https:\/\/greenenergy-repair.com\/es\/products\/abb-sace-tmax-t4d-250-250-a-690-v-with-yo-shunt-trip-24-30-v-ac-dc","provider":"Green Energy","version":"1.0","type":"link"}