{"product_id":"abb-power-one-filter-relay-board-pn-3g83-pb-free-for-inverters-up-to-12-5kw-refurbished-fixes-e013-e032-w003","title":"ABB \/ Power-One Filter \u0026 Relay Board | PN: 3G83 Pb-Free | For Inverters up to 10.0kW \u0026 12.5kW | Refurbished | Fixes E013–E032, W003","description":"\u003cp class=\"\" data-end=\"667\" data-start=\"307\"\u003eThis is a genuine \u003cstrong data-end=\"349\" data-start=\"325\"\u003eFilter \u0026amp; Relay Board\u003c\/strong\u003e for \u003cstrong data-end=\"396\" data-start=\"354\"\u003eAurora ABB \/ Power-One solar inverters\u003c\/strong\u003e rated up to \u003cstrong\u003e10.0kW \u0026amp;\u003c\/strong\u003e \u003cstrong data-end=\"419\" data-start=\"409\"\u003e12.5kW\u003c\/strong\u003e, labeled \u003cstrong data-end=\"445\" data-start=\"429\"\u003e3G83 Pb-Free\u003c\/strong\u003e. The board is responsible for \u003cstrong data-end=\"542\" data-start=\"476\"\u003eAC grid interface filtering, relay switching, surge protection\u003c\/strong\u003e, and communication line conditioning. It is a key element in ensuring stable operation and grid compliance in your inverter.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"861\" data-start=\"669\"\u003eProfessionally \u003cstrong data-end=\"710\" data-start=\"684\"\u003erefurbished and tested\u003c\/strong\u003e, this board includes all original components, such as \u003cstrong data-end=\"860\" data-start=\"765\"\u003eMIROBO high-voltage relays, inductive filters, ferrite chokes, and communication interfaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1079\" data-start=\"863\"\u003e🛠️ \u003cstrong data-end=\"939\" data-start=\"867\"\u003eThis board is known to eliminate the following inverter error codes:\u003c\/strong\u003e\u003cbr data-end=\"942\" data-start=\"939\"\u003e\u003cstrong data-end=\"1004\" data-start=\"942\"\u003eE013, E019, E021, E023, E026, E029, E030, E031, E032, W003\u003c\/strong\u003e\u003cbr data-end=\"1007\" data-start=\"1004\"\u003e(\u003cem data-end=\"1078\" data-start=\"1008\"\u003ealso displayed as: 013, 019, 021, 023, 026, 029, 030, 031, 032, W003\u003c\/em\u003e)\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"1138\" data-start=\"1086\"\u003e🔧 \u003cstrong data-end=\"1136\" data-start=\"1093\"\u003eTechnical Details \u0026amp; Visible Components:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"1171\" data-start=\"1141\"\u003e\n\u003cstrong data-end=\"1156\" data-start=\"1141\"\u003ePCB Number:\u003c\/strong\u003e 3G83 Pb-Free\u003c\/li\u003e\n\u003cli data-end=\"1233\" data-start=\"1174\"\u003e\n\u003cstrong data-end=\"1199\" data-start=\"1174\"\u003eManufacturer Marking:\u003c\/strong\u003e Power-One (pre-ABB acquisition)\u003c\/li\u003e\n\u003cli data-end=\"1278\" data-start=\"1236\"\u003e\n\u003cstrong data-end=\"1254\" data-start=\"1236\"\u003eBarcode Label:\u003c\/strong\u003e 9F53G83E2130586674110\u003c\/li\u003e\n\u003cli data-end=\"1345\" data-start=\"1281\"\u003e\n\u003cstrong data-end=\"1305\" data-start=\"1281\"\u003eRelay (Blue Casing):\u003c\/strong\u003e MIROBO D1L, rated for 800–850V, 275°C\u003c\/li\u003e\n\u003cli data-end=\"1566\" data-start=\"1348\"\u003e\n\u003cstrong data-end=\"1374\" data-start=\"1348\"\u003eAdditional Components:\u003c\/strong\u003e\u003cbr data-end=\"1377\" data-start=\"1374\"\u003e• Ferrite-core inductors \u0026amp; copper-wound chokes\u003cbr data-end=\"1428\" data-start=\"1425\"\u003e• Transformers, MOV varistors for surge protection\u003cbr data-end=\"1483\" data-start=\"1480\"\u003e• Surface components labeled: R76, R78, U8, U9, HS1, GP6, GP7, L9, V5, C57, C64\u003c\/li\u003e\n\u003cli data-end=\"1699\" data-start=\"1569\"\u003e\n\u003cstrong data-end=\"1592\" data-start=\"1569\"\u003eConnectors Present:\u003c\/strong\u003e\u003cbr data-end=\"1595\" data-start=\"1592\"\u003e• IN1, IN2 — DC inputs\u003cbr data-end=\"1622\" data-start=\"1619\"\u003e• GRID — AC grid interface\u003cbr data-end=\"1653\" data-start=\"1650\"\u003e• COMM RS485 — inverter communication port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1731\" data-start=\"1706\"\u003e✅ \u003cstrong data-end=\"1729\" data-start=\"1712\"\u003eKey Benefits:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"2072\" data-start=\"1732\"\u003e✔ Solves common inverter errors related to \u003cstrong data-end=\"1852\" data-start=\"1775\"\u003egrid connection, relay faults, insulation resistance, and system start-up\u003c\/strong\u003e\u003cbr data-end=\"1855\" data-start=\"1852\"\u003e✔ Fully refurbished with tested relays, inductors, and filtered signal paths\u003cbr data-end=\"1934\" data-start=\"1931\"\u003e✔ Essential for restoring AC switching and grid interfacing functions\u003cbr data-end=\"2006\" data-start=\"2003\"\u003e✔ Factory-grade construction on \u003cstrong data-end=\"2072\" data-start=\"2038\"\u003ePb-Free green fiberglass board\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"2106\" data-start=\"2079\"\u003e🔗 \u003cstrong data-end=\"2104\" data-start=\"2086\"\u003eCompatibility:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"2220\" data-start=\"2107\"\u003e✔ \u003cstrong data-end=\"2147\" data-start=\"2109\"\u003eAurora \/ ABB \/ Power-One inverters\u003c\/strong\u003e up to \u003cstrong data-end=\"2164\" data-start=\"2154\"\u003e12.5kW\u003c\/strong\u003e\u003cbr data-end=\"2167\" data-start=\"2164\"\u003e(\u003cem data-end=\"2219\" data-start=\"2168\"\u003ee.g., PVI-10.0-OUTD, PVI-12.5-OUTD\u003c\/em\u003e)\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"2420\" data-start=\"2222\"\u003e📦 \u003cstrong data-end=\"2238\" data-start=\"2225\"\u003eIncludes:\u003c\/strong\u003e Filter \u0026amp; relay board only, no cables or housing\u003cbr data-end=\"2289\" data-start=\"2286\"\u003e🏷️ \u003cstrong data-end=\"2307\" data-start=\"2293\"\u003eCondition:\u003c\/strong\u003e Refurbished \u0026amp; tested\u003cbr data-end=\"2331\" data-start=\"2328\"\u003e⚠️ \u003cstrong data-end=\"2350\" data-start=\"2334\"\u003eInstall Tip:\u003c\/strong\u003e Verify system grounding and logic board condition before replacement.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"2541\" data-start=\"2422\"\u003e🚀 \u003cstrong data-end=\"2541\" data-start=\"2425\"\u003eResolve critical inverter errors and restore safe grid operation with this OEM Power-One filter and relay board.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB Aurora parts","offers":[{"title":"Default Title","offer_id":51644007645517,"sku":"","price":350.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/photo_2025-05-12_15-11-31.jpg?v=1747052855","url":"https:\/\/greenenergy-repair.com\/es\/products\/abb-power-one-filter-relay-board-pn-3g83-pb-free-for-inverters-up-to-12-5kw-refurbished-fixes-e013-e032-w003","provider":"Green Energy","version":"1.0","type":"link"}