{"title":"Accessories \u0026 Components","description":"","products":[{"product_id":"legrand-csa-c22-2-n66-c22-santerno-inverter-insulated-transformer-power-supply","title":"Legrand 44267 – Safety Transformer | 630\/1300 VA | 230\/400 V AC | 115 V Output | Class II | CSA Certified","description":"\u003cp data-start=\"153\" data-end=\"336\"\u003eThe \u003cstrong data-start=\"157\" data-end=\"174\"\u003eLegrand 44267\u003c\/strong\u003e is a \u003cstrong data-start=\"180\" data-end=\"212\"\u003esafety isolation transformer\u003c\/strong\u003e designed for industrial and civil applications where \u003cstrong data-start=\"266\" data-end=\"288\"\u003egalvanic isolation\u003c\/strong\u003e and stable auxiliary power supply are required.\u003c\/p\u003e\n\u003cp data-start=\"338\" data-end=\"533\"\u003eIt is compliant with international standards, including \u003cstrong data-start=\"394\" data-end=\"413\"\u003eCSA C22.2 No.66\u003c\/strong\u003e, as well as IEC\/EN regulations for safety transformers, ensuring reliable and safe operation in demanding environments.\u003c\/p\u003e\n\u003chr data-start=\"535\" data-end=\"538\"\u003e\n\u003ch3 data-start=\"540\" data-end=\"572\"\u003e⚙️ Electrical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"573\" data-end=\"679\"\u003e\n\u003cli data-start=\"573\" data-end=\"628\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eLegrand\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"629\" data-end=\"649\"\u003eModel: \u003cstrong data-start=\"638\" data-end=\"647\"\u003e44267\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"650\" data-end=\"679\"\u003eFrequency: \u003cstrong data-start=\"663\" data-end=\"677\"\u003e50 \/ 60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"681\" data-end=\"698\"\u003e\u003cstrong data-start=\"681\" data-end=\"698\"\u003ePower Rating:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"699\" data-end=\"723\"\u003e\n\u003cli data-start=\"699\" data-end=\"723\"\u003e\u003cstrong data-start=\"701\" data-end=\"721\"\u003e630 VA \/ 1300 VA\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"725\" data-end=\"745\"\u003e\u003cstrong data-start=\"725\" data-end=\"745\"\u003ePrimary Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"746\" data-end=\"826\"\u003e\n\u003cli data-start=\"746\" data-end=\"768\"\u003e\u003cstrong data-start=\"748\" data-end=\"766\"\u003e230 \/ 400 V AC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"769\" data-end=\"826\"\u003eAdjustable taps: \u003cstrong data-start=\"788\" data-end=\"797\"\u003e±15 V\u003c\/strong\u003e (terminals: +15 \/ 0 \/ -15)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"828\" data-end=\"850\"\u003e\u003cstrong data-start=\"828\" data-end=\"850\"\u003eSecondary Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"851\" data-end=\"867\"\u003e\n\u003cli data-start=\"851\" data-end=\"867\"\u003e\u003cstrong data-start=\"853\" data-end=\"865\"\u003e115 V AC\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"869\" data-end=\"872\"\u003e\n\u003ch3 data-start=\"874\" data-end=\"908\"\u003e🔧 Rated Currents (Indicative)\u003c\/h3\u003e\n\u003cul data-start=\"909\" data-end=\"976\"\u003e\n\u003cli data-start=\"909\" data-end=\"928\"\u003e\u003cstrong data-start=\"911\" data-end=\"926\"\u003e230 V → 6 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"976\"\u003e\n\u003cstrong data-start=\"931\" data-end=\"946\"\u003e230 V → 3 A\u003c\/strong\u003e (alternative configuration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"978\" data-end=\"981\"\u003e\n\u003ch3 data-start=\"983\" data-end=\"1010\"\u003e🛡️ Insulation \u0026amp; Safety\u003c\/h3\u003e\n\u003cul data-start=\"1011\" data-end=\"1118\"\u003e\n\u003cli data-start=\"1011\" data-end=\"1045\"\u003eInsulation class: \u003cstrong data-start=\"1031\" data-end=\"1043\"\u003eClass II\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1046\" data-end=\"1078\"\u003eThermal class: \u003cstrong data-start=\"1063\" data-end=\"1076\"\u003eClass 105\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1079\" data-end=\"1118\"\u003eRated insulation voltage: \u003cstrong data-start=\"1107\" data-end=\"1116\"\u003e450 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1120\" data-end=\"1145\"\u003e\u003cstrong data-start=\"1120\" data-end=\"1145\"\u003eStandards compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1146\" data-end=\"1234\"\u003e\n\u003cli data-start=\"1146\" data-end=\"1169\"\u003e\u003cstrong data-start=\"1148\" data-end=\"1167\"\u003eCSA C22.2 No.66\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1170\" data-end=\"1184\"\u003e\u003cstrong data-start=\"1172\" data-end=\"1182\"\u003eUL 506\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1185\" data-end=\"1209\"\u003e\u003cstrong data-start=\"1187\" data-end=\"1207\"\u003eIEC\/EN 61558-2-2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1210\" data-end=\"1234\"\u003e\u003cstrong data-start=\"1212\" data-end=\"1232\"\u003eIEC\/EN 61558-2-4\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1236\" data-end=\"1239\"\u003e\n\u003ch3 data-start=\"1241\" data-end=\"1259\"\u003e🔌 Connections\u003c\/h3\u003e\n\u003cp data-start=\"1261\" data-end=\"1273\"\u003e\u003cstrong data-start=\"1261\" data-end=\"1273\"\u003ePrimary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1274\" data-end=\"1320\"\u003e\n\u003cli data-start=\"1274\" data-end=\"1320\"\u003eTerminals: \u003cstrong data-start=\"1287\" data-end=\"1318\"\u003e+15 \/ 0 \/ -15 \/ 230 \/ 400 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1322\" data-end=\"1336\"\u003e\u003cstrong data-start=\"1322\" data-end=\"1336\"\u003eSecondary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1337\" data-end=\"1399\"\u003e\n\u003cli data-start=\"1337\" data-end=\"1399\"\u003eTerminals: \u003cstrong data-start=\"1350\" data-end=\"1369\"\u003e0 \/ 115 \/ 230 V\u003c\/strong\u003e (selectable configurations)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1401\" data-end=\"1404\"\u003e\n\u003ch3 data-start=\"1406\" data-end=\"1435\"\u003e🏗️ Construction Features\u003c\/h3\u003e\n\u003cul data-start=\"1436\" data-end=\"1621\"\u003e\n\u003cli data-start=\"1436\" data-end=\"1475\"\u003eCompact design with passive cooling\u003c\/li\u003e\n\u003cli data-start=\"1476\" data-end=\"1516\"\u003eHigh-resistance insulating enclosure\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1552\"\u003eLaminated core to reduce losses\u003c\/li\u003e\n\u003cli data-start=\"1553\" data-end=\"1594\"\u003eMounting on plate or electrical panel\u003c\/li\u003e\n\u003cli data-start=\"1595\" data-end=\"1621\"\u003eRobust screw terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1623\" data-end=\"1626\"\u003e\n\u003ch3 data-start=\"1628\" data-end=\"1654\"\u003e⚡ Typical Applications\u003c\/h3\u003e\n\u003cul data-start=\"1655\" data-end=\"1845\"\u003e\n\u003cli data-start=\"1655\" data-end=\"1704\"\u003ePower supply for control and command circuits\u003c\/li\u003e\n\u003cli data-start=\"1705\" data-end=\"1737\"\u003eIndustrial electrical panels\u003c\/li\u003e\n\u003cli data-start=\"1738\" data-end=\"1771\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli data-start=\"1772\" data-end=\"1804\"\u003eSafety and isolation systems\u003c\/li\u003e\n\u003cli data-start=\"1805\" data-end=\"1845\"\u003eAuxiliary power supply for machinery\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":48682333733197,"sku":"","price":50.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5498.jpg?v=1777122943"},{"product_id":"phoenix-contact-val-cp-s-350-valvetrab-val-cp-350-st-type-2-spd-240-415-v-ac-40-ka","title":"Phoenix Contact VAL-CP-S-350 + VALVETRAB VAL-CP 350-ST | Type 2 SPD | 240\/415 V AC | 40 kA |","description":"\u003ch2 data-start=\"141\" data-end=\"160\"\u003e\u003cstrong data-start=\"144\" data-end=\"160\"\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"162\" data-end=\"402\"\u003eThe \u003cstrong data-start=\"166\" data-end=\"198\"\u003ePhoenix Contact VAL-CP-S-350\u003c\/strong\u003e surge protection system equipped with \u003cstrong data-start=\"237\" data-end=\"264\"\u003eVALVETRAB VAL-CP 350-ST\u003c\/strong\u003e plug-in modules is a modular \u003cstrong data-start=\"294\" data-end=\"345\"\u003eType 2 (Class II) Surge Protective Device (SPD)\u003c\/strong\u003e designed for \u003cstrong data-start=\"359\" data-end=\"386\"\u003e240\/415 V AC – 50\/60 Hz\u003c\/strong\u003e power networks.\u003c\/p\u003e\n\u003cp data-start=\"404\" data-end=\"613\"\u003eManufactured by \u003cstrong data-start=\"420\" data-end=\"461\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003ePhoenix Contact\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e, this high-performance SPD protects electrical installations against transient overvoltages caused by indirect lightning strikes and grid disturbances.\u003c\/p\u003e\n\u003cp data-start=\"615\" data-end=\"884\"\u003eThe system features a \u003cstrong data-start=\"637\" data-end=\"664\"\u003emodular DIN rail design\u003c\/strong\u003e with replaceable plug-in cartridges and integrated visual status indicators (green = operational). It is suitable for both single-phase and three-phase AC systems in residential, commercial, and industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"886\" data-end=\"930\"\u003e🛠 \u003cstrong data-start=\"889\" data-end=\"902\"\u003eWarranty:\u003c\/strong\u003e 12 months by Green Energy\u003c\/p\u003e\n\u003chr data-start=\"932\" data-end=\"935\"\u003e\n\u003ch2 data-start=\"937\" data-end=\"961\"\u003e⚙️ Technical Details:\u003c\/h2\u003e\n\u003ch3 data-start=\"963\" data-end=\"995\"\u003e🔹 Base Unit: VAL-CP-S-350\u003c\/h3\u003e\n\u003cp data-start=\"996\" data-end=\"1448\"\u003e\u003cstrong data-start=\"996\" data-end=\"1012\"\u003eArticle No.:\u003c\/strong\u003e 2859563\u003cbr data-start=\"1020\" data-end=\"1023\"\u003e\u003cstrong data-start=\"1023\" data-end=\"1048\"\u003eNominal Voltage (Un):\u003c\/strong\u003e 240\/415 V AC\u003cbr data-start=\"1061\" data-end=\"1064\"\u003e\u003cstrong data-start=\"1064\" data-end=\"1078\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003cbr data-start=\"1087\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1090\" data-end=\"1132\"\u003eMax Continuous Operating Voltage (Uc):\u003c\/strong\u003e 350 V \/ 264 V\u003cbr data-start=\"1146\" data-end=\"1149\"\u003e\u003cstrong data-start=\"1149\" data-end=\"1183\"\u003eVoltage Protection Level (Up):\u003c\/strong\u003e 1.4 kV \/ 1.5 kV\u003cbr data-start=\"1199\" data-end=\"1202\"\u003e\u003cstrong data-start=\"1202\" data-end=\"1237\"\u003eNominal Discharge Current (In):\u003c\/strong\u003e 20 kA\u003cbr data-start=\"1243\" data-end=\"1246\"\u003e\u003cstrong data-start=\"1246\" data-end=\"1283\"\u003eMaximum Discharge Current (Imax):\u003c\/strong\u003e 40 kA (8\/20 µs)\u003cbr data-start=\"1299\" data-end=\"1302\"\u003e\u003cstrong data-start=\"1302\" data-end=\"1315\"\u003eSPD Type:\u003c\/strong\u003e Type 2 (T2)\u003cbr data-start=\"1327\" data-end=\"1330\"\u003e\u003cstrong data-start=\"1330\" data-end=\"1345\"\u003eTest Class:\u003c\/strong\u003e II – C\u003cbr data-start=\"1352\" data-end=\"1355\"\u003e\u003cstrong data-start=\"1355\" data-end=\"1375\"\u003eMax Backup Fuse:\u003c\/strong\u003e 125 A\u003cbr data-start=\"1381\" data-end=\"1384\"\u003e\u003cstrong data-start=\"1384\" data-end=\"1403\"\u003eCertifications:\u003c\/strong\u003e CE, UL, KEMA-KEUR\u003cbr data-start=\"1421\" data-end=\"1424\"\u003e\u003cstrong data-start=\"1424\" data-end=\"1437\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003ch3 data-start=\"1450\" data-end=\"1475\"\u003e🔹 Plug-in Modules:\u003c\/h3\u003e\n\u003cp data-start=\"1476\" data-end=\"1618\"\u003e\u003cstrong data-start=\"1476\" data-end=\"1487\"\u003eSeries:\u003c\/strong\u003e VALVETRAB\u003cbr data-start=\"1497\" data-end=\"1500\"\u003e\u003cstrong data-start=\"1500\" data-end=\"1510\"\u003eModel:\u003c\/strong\u003e VAL-CP 350-ST\u003cbr data-start=\"1524\" data-end=\"1527\"\u003e\u003cstrong data-start=\"1527\" data-end=\"1548\"\u003eStatus Indicator:\u003c\/strong\u003e Green window (operational status)\u003cbr data-start=\"1582\" data-end=\"1585\"\u003e\u003cstrong data-start=\"1585\" data-end=\"1612\"\u003eReplaceable Cartridges:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr data-start=\"1620\" data-end=\"1623\"\u003e\n\u003ch2 data-start=\"1625\" data-end=\"1645\"\u003e📌 Key Functions:\u003c\/h2\u003e\n\u003cp data-start=\"1647\" data-end=\"1978\"\u003e✔️ Type 2 surge protection for AC power networks\u003cbr data-start=\"1695\" data-end=\"1698\"\u003e✔️ Suitable for 240\/415 V single-phase and three-phase systems\u003cbr data-start=\"1760\" data-end=\"1763\"\u003e✔️ Discharge capacity up to 40 kA\u003cbr data-start=\"1796\" data-end=\"1799\"\u003e✔️ Replaceable plug-in protection modules\u003cbr data-start=\"1840\" data-end=\"1843\"\u003e✔️ Integrated visual status indication\u003cbr data-start=\"1881\" data-end=\"1884\"\u003e✔️ DIN rail mounting for easy installation\u003cbr data-start=\"1926\" data-end=\"1929\"\u003e✔️ Industrial-grade Phoenix Contact reliability\u003c\/p\u003e\n\u003chr data-start=\"1980\" data-end=\"1983\"\u003e\n\u003ch2 data-start=\"1985\" data-end=\"2004\"\u003e🛠 Applications:\u003c\/h2\u003e\n\u003cp data-start=\"2006\" data-end=\"2215\"\u003e✔️ Residential and industrial electrical panels\u003cbr data-start=\"2053\" data-end=\"2056\"\u003e✔️ Power distribution systems\u003cbr data-start=\"2085\" data-end=\"2088\"\u003e✔️ Commercial and technical installations\u003cbr data-start=\"2129\" data-end=\"2132\"\u003e✔️ Protection of sensitive electronic equipment\u003cbr data-start=\"2179\" data-end=\"2182\"\u003e✔️ 240\/415 V AC infrastructures\u003c\/p\u003e\n\u003chr data-start=\"2217\" data-end=\"2220\"\u003e\n\u003ch2 data-start=\"2222\" data-end=\"2247\"\u003e⚡ Operating Principle:\u003c\/h2\u003e\n\u003cp data-start=\"2249\" data-end=\"2289\"\u003eIn the event of a transient overvoltage:\u003c\/p\u003e\n\u003cul data-start=\"2291\" data-end=\"2481\"\u003e\n\u003cli data-start=\"2291\" data-end=\"2332\"\u003e\n\u003cp data-start=\"2293\" data-end=\"2332\"\u003eThe SPD intercepts the voltage spike.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2333\" data-end=\"2385\"\u003e\n\u003cp data-start=\"2335\" data-end=\"2385\"\u003eExcess surge energy is safely diverted to earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2386\" data-end=\"2481\"\u003e\n\u003cp data-start=\"2388\" data-end=\"2481\"\u003eResidual voltage is limited to approximately \u003cstrong data-start=\"2433\" data-end=\"2447\"\u003e1.4–1.5 kV\u003c\/strong\u003e, protecting downstream devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Phoenix Contact","offers":[{"title":"Default Title","offer_id":53348732272973,"sku":null,"price":45.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4829.jpg?v=1770918808"},{"product_id":"con-trade-spd-tipo-2-l-2-0-cod-210004-type-2-surge-arrester-3-pole-400-480-v-ac-40-ka-class-ii-for-electrical-panels","title":"CON.TRADE SPD Tipo 2 L\/2\/0 Cod. 210004 – Type 2 Surge Arrester | 3-Pole | 400–480 V AC | 40 kA | Class II | For Electrical Panels","description":"\u003cp data-start=\"207\" data-end=\"425\"\u003eThe \u003cstrong data-start=\"211\" data-end=\"255\"\u003eCON.TRADE SPD Type 2 L\/2\/0 – Code 210004\u003c\/strong\u003e is a \u003cstrong data-start=\"261\" data-end=\"312\"\u003eClass II (Type 2) Surge Protective Device (SPD)\u003c\/strong\u003e designed to protect \u003cstrong data-start=\"333\" data-end=\"393\"\u003ethree-phase electrical systems operating at 400–480 V AC\u003c\/strong\u003e against transient overvoltages.\u003c\/p\u003e\n\u003cp data-start=\"427\" data-end=\"640\"\u003eEngineered for installation inside electrical distribution boards, this surge arrester protects equipment from voltage spikes caused by indirect lightning strikes and switching operations within the power network.\u003c\/p\u003e\n\u003cp data-start=\"642\" data-end=\"957\"\u003eWith a \u003cstrong data-start=\"649\" data-end=\"698\"\u003emaximum discharge capacity of 40 kA (8\/20 μs)\u003c\/strong\u003e, the device provides reliable protection for industrial and commercial installations. Its \u003cstrong data-start=\"789\" data-end=\"821\"\u003e3-pole configuration (L\/2\/0)\u003c\/strong\u003e makes it suitable for standard three-phase systems without neutral protection, ensuring effective safeguarding of downstream equipment.\u003c\/p\u003e\n\u003cp data-start=\"959\" data-end=\"1070\"\u003eDesigned for \u003cstrong data-start=\"972\" data-end=\"993\"\u003eDIN rail mounting\u003c\/strong\u003e, the unit allows fast and secure installation in standard electrical panels.\u003c\/p\u003e\n\u003chr data-start=\"1072\" data-end=\"1075\"\u003e\n\u003ch2 data-start=\"1077\" data-end=\"1114\"\u003e⚙️ Main Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1116\" data-end=\"1344\"\u003e\u003cstrong data-start=\"1116\" data-end=\"1133\"\u003eManufacturer:\u003c\/strong\u003e CON.TRADE\u003cbr data-start=\"1143\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1156\"\u003eModel:\u003c\/strong\u003e SPD Type 2 L\/2\/0\u003cbr data-start=\"1173\" data-end=\"1176\"\u003e\u003cstrong data-start=\"1176\" data-end=\"1193\"\u003eArticle Code:\u003c\/strong\u003e 210004\u003cbr data-start=\"1200\" data-end=\"1203\"\u003e\u003cstrong data-start=\"1203\" data-end=\"1219\"\u003eDevice Type:\u003c\/strong\u003e Surge Protective Device (SPD)\u003cbr data-start=\"1249\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1252\" data-end=\"1262\"\u003eClass:\u003c\/strong\u003e Class II \/ Type 2\u003cbr data-start=\"1280\" data-end=\"1283\"\u003e\u003cstrong data-start=\"1283\" data-end=\"1301\"\u003eConfiguration:\u003c\/strong\u003e 3 poles (L\/2\/0)\u003cbr data-start=\"1317\" data-end=\"1320\"\u003e\u003cstrong data-start=\"1320\" data-end=\"1333\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003chr data-start=\"1346\" data-end=\"1349\"\u003e\n\u003ch3 data-start=\"1351\" data-end=\"1375\"\u003e🔌 Electrical Data\u003c\/h3\u003e\n\u003cul data-start=\"1377\" data-end=\"1579\"\u003e\n\u003cli data-start=\"1377\" data-end=\"1427\"\u003e\n\u003cp data-start=\"1379\" data-end=\"1427\"\u003eRated operating voltage (Un): \u003cstrong data-start=\"1409\" data-end=\"1425\"\u003e400–480 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1428\" data-end=\"1485\"\u003e\n\u003cp data-start=\"1430\" data-end=\"1485\"\u003eMaximum discharge current (Imax): \u003cstrong data-start=\"1464\" data-end=\"1483\"\u003e40 kA (8\/20 μs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1486\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1488\" data-end=\"1551\"\u003eNominal discharge current (In): typically \u003cstrong data-start=\"1530\" data-end=\"1549\"\u003e20 kA (8\/20 μs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1552\" data-end=\"1579\"\u003e\n\u003cp data-start=\"1554\" data-end=\"1579\"\u003eFrequency: \u003cstrong data-start=\"1565\" data-end=\"1577\"\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1581\" data-end=\"1584\"\u003e\n\u003ch2 data-start=\"1586\" data-end=\"1606\"\u003e🔧 Key Features\u003c\/h2\u003e\n\u003cp data-start=\"1608\" data-end=\"1896\"\u003e✔️ Type 2 \/ Class II surge protection\u003cbr data-start=\"1645\" data-end=\"1648\"\u003e✔️ Suitable for 400–480 V AC three-phase systems\u003cbr data-start=\"1696\" data-end=\"1699\"\u003e✔️ Maximum discharge capacity up to 40 kA\u003cbr data-start=\"1740\" data-end=\"1743\"\u003e✔️ 3-pole configuration\u003cbr data-start=\"1766\" data-end=\"1769\"\u003e✔️ DIN rail mounting\u003cbr data-start=\"1789\" data-end=\"1792\"\u003e✔️ Designed for electrical distribution panels\u003cbr data-start=\"1838\" data-end=\"1841\"\u003e✔️ Reliable protection against transient overvoltages\u003c\/p\u003e\n\u003chr data-start=\"1898\" data-end=\"1901\"\u003e\n\u003ch2 data-start=\"1903\" data-end=\"1929\"\u003e🔗 Ideal Applications\u003c\/h2\u003e\n\u003cp data-start=\"1931\" data-end=\"2143\"\u003e✔️ Industrial distribution boards\u003cbr data-start=\"1964\" data-end=\"1967\"\u003e✔️ Commercial electrical panels\u003cbr data-start=\"1998\" data-end=\"2001\"\u003e✔️ Power distribution systems\u003cbr data-start=\"2030\" data-end=\"2033\"\u003e✔️ Protection of machinery and electrical equipment\u003cbr data-start=\"2084\" data-end=\"2087\"\u003e✔️ Three-phase installations in technical environments\u003c\/p\u003e","brand":"CON.TRADE SPD","offers":[{"title":"Default Title","offer_id":53419434901837,"sku":null,"price":50.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4850.jpg?v=1771931783"},{"product_id":"dehnguard-dg-m-ypv-sci-1000-fm-dehn-dg-mod-string-500-pe-500-type-2-spd-for-photovoltaic-systems-1000-v-dc-40-ka","title":"DEHNguard DG M YPV SCI 1000 FM + DEHN DG MOD STRING 500 \/ PE 500 | Type 2 SPD for Photovoltaic Systems | 1000 V DC | 40 kA","description":"\u003cp data-start=\"200\" data-end=\"405\"\u003eThe \u003cstrong data-start=\"204\" data-end=\"238\"\u003eDEHNguard DG M YPV SCI 1000 FM\u003c\/strong\u003e combined with \u003cstrong data-start=\"253\" data-end=\"283\"\u003eDG MOD STRING 500 \/ PE 500\u003c\/strong\u003e is a \u003cstrong data-start=\"289\" data-end=\"329\"\u003eType 2 Surge Protective Device (SPD)\u003c\/strong\u003e specifically designed for \u003cstrong data-start=\"356\" data-end=\"404\"\u003ephotovoltaic (PV) DC systems up to 1000 V DC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"407\" data-end=\"661\"\u003eManufactured by \u003cstrong data-start=\"423\" data-end=\"464\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eDEHN\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e, this surge protection solution is engineered to protect PV string circuits and downstream inverter inputs against transient overvoltages caused by indirect lightning strikes and switching events.\u003c\/p\u003e\n\u003cp data-start=\"663\" data-end=\"1003\"\u003eThe system integrates DEHN’s \u003cstrong data-start=\"692\" data-end=\"736\"\u003eSCI (Short Circuit Interrupt) technology\u003c\/strong\u003e, which eliminates the need for additional external backup fuses in many configurations, enhancing system safety and simplifying installation. The \u003cstrong data-start=\"883\" data-end=\"923\"\u003eFM (Fault Monitoring) remote contact\u003c\/strong\u003e allows real-time status monitoring of the SPD for improved operational control.\u003c\/p\u003e\n\u003cp data-start=\"1005\" data-end=\"1175\"\u003eWith a \u003cstrong data-start=\"1012\" data-end=\"1066\"\u003emaximum discharge current of up to 40 kA (8\/20 μs)\u003c\/strong\u003e, this device provides high discharge capacity and reliable protection for sensitive photovoltaic components.\u003c\/p\u003e\n\u003cp data-start=\"1177\" data-end=\"1336\"\u003eDesigned for \u003cstrong data-start=\"1190\" data-end=\"1211\"\u003eDIN rail mounting\u003c\/strong\u003e, the modular construction allows for fast installation and easy maintenance in PV combiner boxes and DC distribution panels.\u003c\/p\u003e\n\u003chr data-start=\"1338\" data-end=\"1341\"\u003e\n\u003ch2 data-start=\"1343\" data-end=\"1380\"\u003e⚙️ Main Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1382\" data-end=\"1620\"\u003e\u003cstrong data-start=\"1382\" data-end=\"1399\"\u003eManufacturer:\u003c\/strong\u003e DEHN\u003cbr data-start=\"1404\" data-end=\"1407\"\u003e\u003cstrong data-start=\"1407\" data-end=\"1426\"\u003eProduct Series:\u003c\/strong\u003e DEHNguard\u003cbr data-start=\"1436\" data-end=\"1439\"\u003e\u003cstrong data-start=\"1439\" data-end=\"1449\"\u003eModel:\u003c\/strong\u003e DG M YPV SCI 1000 FM\u003cbr data-start=\"1470\" data-end=\"1473\"\u003e\u003cstrong data-start=\"1473\" data-end=\"1495\"\u003eAdditional Module:\u003c\/strong\u003e DG MOD STRING 500 \/ PE 500\u003cbr data-start=\"1522\" data-end=\"1525\"\u003e\u003cstrong data-start=\"1525\" data-end=\"1538\"\u003eSPD Type:\u003c\/strong\u003e Type 2 (T2)\u003cbr data-start=\"1550\" data-end=\"1553\"\u003e\u003cstrong data-start=\"1553\" data-end=\"1569\"\u003eApplication:\u003c\/strong\u003e Photovoltaic DC systems\u003cbr data-start=\"1593\" data-end=\"1596\"\u003e\u003cstrong data-start=\"1596\" data-end=\"1609\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003chr data-start=\"1622\" data-end=\"1625\"\u003e\n\u003ch3 data-start=\"1627\" data-end=\"1651\"\u003e🔌 Electrical Data\u003c\/h3\u003e\n\u003cul data-start=\"1653\" data-end=\"1951\"\u003e\n\u003cli data-start=\"1653\" data-end=\"1701\"\u003e\n\u003cp data-start=\"1655\" data-end=\"1701\"\u003eMaximum system voltage (Ucpv): \u003cstrong data-start=\"1686\" data-end=\"1699\"\u003e1000 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1702\" data-end=\"1759\"\u003e\n\u003cp data-start=\"1704\" data-end=\"1759\"\u003eMaximum discharge current (Imax): \u003cstrong data-start=\"1738\" data-end=\"1757\"\u003e40 kA (8\/20 μs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1760\" data-end=\"1825\"\u003e\n\u003cp data-start=\"1762\" data-end=\"1825\"\u003eNominal discharge current (In): typically \u003cstrong data-start=\"1804\" data-end=\"1823\"\u003e20 kA (8\/20 μs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1826\" data-end=\"1882\"\u003e\n\u003cp data-start=\"1828\" data-end=\"1882\"\u003eProtection mode: \u003cstrong data-start=\"1845\" data-end=\"1860\"\u003e+ \/ – to PE\u003c\/strong\u003e (string protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1883\" data-end=\"1951\"\u003e\n\u003cp data-start=\"1885\" data-end=\"1951\"\u003eIntegrated SCI technology (internal short-circuit disconnection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1953\" data-end=\"1956\"\u003e\n\u003ch2 data-start=\"1958\" data-end=\"1985\"\u003e🔔 Additional Features\u003c\/h2\u003e\n\u003cul data-start=\"1987\" data-end=\"2159\"\u003e\n\u003cli data-start=\"1987\" data-end=\"2020\"\u003e\n\u003cp data-start=\"1989\" data-end=\"2020\"\u003eRemote signaling contact (FM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2021\" data-end=\"2053\"\u003e\n\u003cp data-start=\"2023\" data-end=\"2053\"\u003ePluggable protection modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2054\" data-end=\"2093\"\u003e\n\u003cp data-start=\"2056\" data-end=\"2093\"\u003eHigh DC voltage capability (1000 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2094\" data-end=\"2132\"\u003e\n\u003cp data-start=\"2096\" data-end=\"2132\"\u003eOptimized for PV string protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2159\"\u003e\n\u003cp data-start=\"2135\" data-end=\"2159\"\u003eCompact modular design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2161\" data-end=\"2164\"\u003e\n\u003ch2 data-start=\"2166\" data-end=\"2186\"\u003e🔧 Key Features\u003c\/h2\u003e\n\u003cp data-start=\"2188\" data-end=\"2509\"\u003e✔️ Type 2 SPD for photovoltaic DC systems\u003cbr data-start=\"2229\" data-end=\"2232\"\u003e✔️ Suitable for installations up to 1000 V DC\u003cbr data-start=\"2277\" data-end=\"2280\"\u003e✔️ Discharge capacity up to 40 kA\u003cbr data-start=\"2313\" data-end=\"2316\"\u003e✔️ Integrated SCI technology (no additional backup fuse required in many cases)\u003cbr data-start=\"2395\" data-end=\"2398\"\u003e✔️ Remote monitoring contact (FM)\u003cbr data-start=\"2431\" data-end=\"2434\"\u003e✔️ DIN rail mounting\u003cbr data-start=\"2454\" data-end=\"2457\"\u003e✔️ High-quality German-engineered surge protection\u003c\/p\u003e\n\u003chr data-start=\"2511\" data-end=\"2514\"\u003e\n\u003ch2 data-start=\"2516\" data-end=\"2542\"\u003e🔗 Ideal Applications\u003c\/h2\u003e\n\u003cp data-start=\"2544\" data-end=\"2736\"\u003e✔️ Photovoltaic combiner boxes\u003cbr data-start=\"2574\" data-end=\"2577\"\u003e✔️ DC distribution panels\u003cbr data-start=\"2602\" data-end=\"2605\"\u003e✔️ Rooftop and ground-mounted solar installations\u003cbr data-start=\"2654\" data-end=\"2657\"\u003e✔️ Commercial and industrial PV systems\u003cbr data-start=\"2696\" data-end=\"2699\"\u003e✔️ Protection of inverter DC inputs\u003c\/p\u003e","brand":"DEHNguard","offers":[{"title":"Default Title","offer_id":53419444601165,"sku":null,"price":100.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4840.jpg?v=1771928643"},{"product_id":"wohner-aes-2x38-art-31112-2-pole-modular-fuse-holder-10x38-mm-32a-up-to-690v-ac-din-rail-iec-60947-3","title":"Wöhner AES 2x38 Art. 31112 – 2-Pole Modular Fuse Holder 10x38 mm | 32A | Up to 690V AC | DIN Rail | IEC 60947-3","description":"\u003cp data-start=\"190\" data-end=\"382\"\u003eThe \u003cstrong data-start=\"194\" data-end=\"233\"\u003eWöhner AES 2x38 – Article No. 31112\u003c\/strong\u003e is a \u003cstrong data-start=\"239\" data-end=\"271\"\u003etwo-pole modular fuse holder\u003c\/strong\u003e designed for cylindrical \u003cstrong data-start=\"297\" data-end=\"315\"\u003e10x38 mm fuses\u003c\/strong\u003e, suitable for low-voltage distribution systems up to \u003cstrong data-start=\"369\" data-end=\"381\"\u003e690 V AC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"384\" data-end=\"551\"\u003eManufactured according to \u003cstrong data-start=\"410\" data-end=\"425\"\u003eIEC 60947-3\u003c\/strong\u003e, this device ensures high reliability, operational safety, and the robust construction quality typical of German engineering.\u003c\/p\u003e\n\u003cp data-start=\"553\" data-end=\"729\"\u003eIt is intended for the protection of electrical lines, control circuits, and industrial applications requiring fuse-based protection using \u003cstrong data-start=\"692\" data-end=\"728\"\u003egG, aM, or equivalent fuse types\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"897\"\u003eThe sectional (switch-disconnector) design allows safe manual isolation of the circuit and quick fuse replacement, improving maintenance efficiency and system safety.\u003c\/p\u003e\n\u003chr data-start=\"899\" data-end=\"902\"\u003e\n\u003ch2 data-start=\"904\" data-end=\"936\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"938\" data-end=\"1281\"\u003e\u003cstrong data-start=\"938\" data-end=\"948\"\u003eBrand:\u003c\/strong\u003e Wöhner\u003cbr data-start=\"955\" data-end=\"958\"\u003e\u003cstrong data-start=\"958\" data-end=\"968\"\u003eModel:\u003c\/strong\u003e AES 2x38\u003cbr data-start=\"977\" data-end=\"980\"\u003e\u003cstrong data-start=\"980\" data-end=\"999\"\u003eArticle Number:\u003c\/strong\u003e 31 112\u003cbr data-start=\"1006\" data-end=\"1009\"\u003e\u003cstrong data-start=\"1009\" data-end=\"1018\"\u003eType:\u003c\/strong\u003e Fuse holder \/ switch-disconnector\u003cbr data-start=\"1052\" data-end=\"1055\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1075\"\u003eNumber of poles:\u003c\/strong\u003e 2\u003cbr data-start=\"1077\" data-end=\"1080\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1094\"\u003eFuse size:\u003c\/strong\u003e 10x38 mm\u003cbr data-start=\"1103\" data-end=\"1106\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1119\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003cbr data-start=\"1128\" data-end=\"1131\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1156\"\u003eDegree of protection:\u003c\/strong\u003e IP20 (when installed)\u003cbr data-start=\"1178\" data-end=\"1181\"\u003e\u003cstrong data-start=\"1181\" data-end=\"1194\"\u003eMaterial:\u003c\/strong\u003e Self-extinguishing thermoplastic\u003cbr data-start=\"1227\" data-end=\"1230\"\u003e\u003cstrong data-start=\"1230\" data-end=\"1245\"\u003eProduction:\u003c\/strong\u003e Made in Germany\u003cbr data-start=\"1261\" data-end=\"1264\"\u003e\u003cstrong data-start=\"1264\" data-end=\"1276\"\u003eMarking:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003ch3 data-start=\"1283\" data-end=\"1307\"\u003e🔌 Electrical Data\u003c\/h3\u003e\n\u003cul data-start=\"1309\" data-end=\"1441\"\u003e\n\u003cli data-start=\"1309\" data-end=\"1336\"\u003e\n\u003cp data-start=\"1311\" data-end=\"1336\"\u003eRated current: \u003cstrong data-start=\"1326\" data-end=\"1334\"\u003e32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1337\" data-end=\"1376\"\u003e\n\u003cp data-start=\"1339\" data-end=\"1376\"\u003eRated voltage: \u003cstrong data-start=\"1354\" data-end=\"1374\"\u003e400 V \/ 690 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1377\" data-end=\"1404\"\u003e\n\u003cp data-start=\"1379\" data-end=\"1404\"\u003eFrequency: \u003cstrong data-start=\"1390\" data-end=\"1402\"\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1405\" data-end=\"1441\"\u003e\n\u003cp data-start=\"1407\" data-end=\"1441\"\u003eUtilization category: \u003cstrong data-start=\"1429\" data-end=\"1439\"\u003eAC-22B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1443\" data-end=\"1461\"\u003e📜 Standards\u003c\/h3\u003e\n\u003cul data-start=\"1463\" data-end=\"1496\"\u003e\n\u003cli data-start=\"1463\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1465\" data-end=\"1478\"\u003eIEC 60947-3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1479\" data-end=\"1496\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1496\"\u003eIEC 60269-2-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1498\" data-end=\"1528\"\u003e🔄 Compatible Fuse Types\u003c\/h3\u003e\n\u003cul data-start=\"1530\" data-end=\"1617\"\u003e\n\u003cli data-start=\"1530\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1532\" data-end=\"1536\"\u003egG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1537\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1539\" data-end=\"1543\"\u003eaM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1546\" data-end=\"1617\"\u003egR \/ aR (refer to technical documentation for specific compatibility)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1619\" data-end=\"1622\"\u003e\n\u003ch2 data-start=\"1624\" data-end=\"1640\"\u003e🔎 Function\u003c\/h2\u003e\n\u003cp data-start=\"1642\" data-end=\"1669\"\u003eThe fuse holder provides:\u003c\/p\u003e\n\u003cp data-start=\"1671\" data-end=\"1838\"\u003e✔ Secure accommodation of cylindrical fuse links\u003cbr data-start=\"1719\" data-end=\"1722\"\u003e✔ Manual circuit isolation\u003cbr data-start=\"1748\" data-end=\"1751\"\u003e✔ Protection against overloads and short circuits\u003cbr data-start=\"1800\" data-end=\"1803\"\u003e✔ Quick and safe fuse replacement\u003c\/p\u003e\n\u003cp data-start=\"1840\" data-end=\"1919\"\u003eThe lever mechanism ensures safe opening and simplified maintenance operations.\u003c\/p\u003e\n\u003chr data-start=\"1921\" data-end=\"1924\"\u003e\n\u003ch2 data-start=\"1926\" data-end=\"1946\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1948\" data-end=\"2161\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1978\" data-end=\"1981\"\u003e✔ Low-voltage distribution systems\u003cbr data-start=\"2015\" data-end=\"2018\"\u003e✔ Three-phase line protection\u003cbr data-start=\"2047\" data-end=\"2050\"\u003e✔ Control circuit protection\u003cbr data-start=\"2078\" data-end=\"2081\"\u003e✔ Photovoltaic systems (with suitable fuses)\u003cbr data-start=\"2125\" data-end=\"2128\"\u003e✔ Industrial automation systems\u003c\/p\u003e\n\u003chr data-start=\"2163\" data-end=\"2166\"\u003e\n\u003ch2 data-start=\"2168\" data-end=\"2188\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2190\" data-end=\"2385\"\u003e\n\u003cli data-start=\"2190\" data-end=\"2223\"\u003e\n\u003cp data-start=\"2192\" data-end=\"2223\"\u003eMounting on standard DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2224\" data-end=\"2287\"\u003e\n\u003cp data-start=\"2226\" data-end=\"2287\"\u003eCopper conductor connection according to IEC specifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2288\" data-end=\"2342\"\u003e\n\u003cp data-start=\"2290\" data-end=\"2342\"\u003eTightening torque as per manufacturer instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2343\" data-end=\"2385\"\u003e\n\u003cp data-start=\"2345\" data-end=\"2385\"\u003eSuitable for 10x38 mm fuses up to 32 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2387\" data-end=\"2390\"\u003e\n\u003ch2 data-start=\"2392\" data-end=\"2409\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2411\" data-end=\"2503\"\u003eUsed product in good cosmetic and structural condition.\u003cbr data-start=\"2466\" data-end=\"2469\"\u003eSupplied as shown in the images.\u003c\/p\u003e\n\u003chr data-start=\"2505\" data-end=\"2508\"\u003e\n\u003ch2 data-start=\"2510\" data-end=\"2527\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cp data-start=\"2529\" data-end=\"2715\"\u003e✔ High-quality German manufacturing\u003cbr data-start=\"2564\" data-end=\"2567\"\u003e✔ Rated voltage up to 690 V\u003cbr data-start=\"2594\" data-end=\"2597\"\u003e✔ Compact modular structure\u003cbr data-start=\"2624\" data-end=\"2627\"\u003e✔ High operational safety\u003cbr data-start=\"2652\" data-end=\"2655\"\u003e✔ Easy maintenance\u003cbr data-start=\"2673\" data-end=\"2676\"\u003e✔ Compatible with multiple fuse types\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53426020352333,"sku":null,"price":10.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4894.jpg?v=1772012115"},{"product_id":"wohner-aes-3x38-art-31113-3-pole-switch-disconnector-fuse-holder-10x38-mm-32a-690v-ac-din-rail-iec-60947-3","title":"Wöhner AES 3x38 Art. 31113 – 3-Pole Switch-Disconnector Fuse Holder 10x38 mm | 32A | 690V AC | DIN Rail | IEC 60947-3","description":"\u003cp data-start=\"196\" data-end=\"410\"\u003eThe \u003cstrong data-start=\"200\" data-end=\"239\"\u003eWöhner AES 3x38 – Article No. 31113\u003c\/strong\u003e is a \u003cstrong data-start=\"245\" data-end=\"299\"\u003ethree-pole modular switch-disconnector fuse holder\u003c\/strong\u003e designed for cylindrical \u003cstrong data-start=\"325\" data-end=\"343\"\u003e10x38 mm fuses\u003c\/strong\u003e, suitable for low-voltage distribution systems up to \u003cstrong data-start=\"397\" data-end=\"409\"\u003e690 V AC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"412\" data-end=\"674\"\u003ePart of the professional Wöhner product range, this device ensures high operational reliability, safe switching performance, and robust mechanical construction, making it ideal for industrial applications, automation systems, and three-phase distribution panels.\u003c\/p\u003e\n\u003cp data-start=\"676\" data-end=\"840\"\u003eThe design allows \u003cstrong data-start=\"694\" data-end=\"734\"\u003esafe manual isolation of the circuit\u003c\/strong\u003e and effective protection against overloads and short circuits using \u003cstrong data-start=\"803\" data-end=\"839\"\u003egG, aM, or equivalent fuse types\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"842\" data-end=\"845\"\u003e\n\u003ch2 data-start=\"847\" data-end=\"879\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"881\" data-end=\"1259\"\u003e\u003cstrong data-start=\"881\" data-end=\"891\"\u003eBrand:\u003c\/strong\u003e Wöhner\u003cbr data-start=\"898\" data-end=\"901\"\u003e\u003cstrong data-start=\"901\" data-end=\"911\"\u003eModel:\u003c\/strong\u003e AES 3x38\u003cbr data-start=\"920\" data-end=\"923\"\u003e\u003cstrong data-start=\"923\" data-end=\"942\"\u003eArticle Number:\u003c\/strong\u003e 31 113\u003cbr data-start=\"949\" data-end=\"952\"\u003e\u003cstrong data-start=\"952\" data-end=\"961\"\u003eType:\u003c\/strong\u003e Modular switch-disconnector fuse holder\u003cbr data-start=\"1001\" data-end=\"1004\"\u003e\u003cstrong data-start=\"1004\" data-end=\"1024\"\u003eNumber of poles:\u003c\/strong\u003e 3\u003cbr data-start=\"1026\" data-end=\"1029\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1043\"\u003eFuse size:\u003c\/strong\u003e 10x38 mm\u003cbr data-start=\"1052\" data-end=\"1055\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1068\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003cbr data-start=\"1077\" data-end=\"1080\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1105\"\u003eDegree of protection:\u003c\/strong\u003e IP20 (when installed in enclosure)\u003cbr data-start=\"1140\" data-end=\"1143\"\u003e\u003cstrong data-start=\"1143\" data-end=\"1156\"\u003eMaterial:\u003c\/strong\u003e High-resistance self-extinguishing thermoplastic\u003cbr data-start=\"1205\" data-end=\"1208\"\u003e\u003cstrong data-start=\"1208\" data-end=\"1223\"\u003eProduction:\u003c\/strong\u003e Made in Germany\u003cbr data-start=\"1239\" data-end=\"1242\"\u003e\u003cstrong data-start=\"1242\" data-end=\"1254\"\u003eMarking:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003ch3 data-start=\"1261\" data-end=\"1285\"\u003e🔌 Electrical Data\u003c\/h3\u003e\n\u003cul data-start=\"1287\" data-end=\"1419\"\u003e\n\u003cli data-start=\"1287\" data-end=\"1314\"\u003e\n\u003cp data-start=\"1289\" data-end=\"1314\"\u003eRated current: \u003cstrong data-start=\"1304\" data-end=\"1312\"\u003e32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1315\" data-end=\"1354\"\u003e\n\u003cp data-start=\"1317\" data-end=\"1354\"\u003eRated voltage: \u003cstrong data-start=\"1332\" data-end=\"1352\"\u003e400 V \/ 690 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1355\" data-end=\"1382\"\u003e\n\u003cp data-start=\"1357\" data-end=\"1382\"\u003eFrequency: \u003cstrong data-start=\"1368\" data-end=\"1380\"\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1383\" data-end=\"1419\"\u003e\n\u003cp data-start=\"1385\" data-end=\"1419\"\u003eUtilization category: \u003cstrong data-start=\"1407\" data-end=\"1417\"\u003eAC-22B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1421\" data-end=\"1450\"\u003e📜 Applicable Standards\u003c\/h3\u003e\n\u003cul data-start=\"1452\" data-end=\"1485\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1467\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1467\"\u003eIEC 60947-3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1468\" data-end=\"1485\"\u003e\n\u003cp data-start=\"1470\" data-end=\"1485\"\u003eIEC 60269-2-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1487\" data-end=\"1517\"\u003e🔄 Compatible Fuse Types\u003c\/h3\u003e\n\u003cul data-start=\"1519\" data-end=\"1617\"\u003e\n\u003cli data-start=\"1519\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1521\" data-end=\"1543\"\u003egG (general purpose)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1546\" data-end=\"1569\"\u003eaM (motor protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1617\"\u003eaR \/ gR (subject to technical verification)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1619\" data-end=\"1622\"\u003e\n\u003ch2 data-start=\"1624\" data-end=\"1649\"\u003e🔎 Function \u0026amp; Safety\u003c\/h2\u003e\n\u003cp data-start=\"1651\" data-end=\"1676\"\u003eThe fuse holder allows:\u003c\/p\u003e\n\u003cp data-start=\"1678\" data-end=\"1824\"\u003e✔ Quick fuse insertion and replacement\u003cbr data-start=\"1716\" data-end=\"1719\"\u003e✔ Manual circuit disconnection\u003cbr data-start=\"1749\" data-end=\"1752\"\u003e✔ Reliable protection against overcurrents\u003cbr data-start=\"1794\" data-end=\"1797\"\u003e✔ High operational safety\u003c\/p\u003e\n\u003cp data-start=\"1826\" data-end=\"1976\"\u003eThe lever-operated mechanism ensures controlled opening and simplified maintenance, with a compact structure suitable for modular distribution boards.\u003c\/p\u003e\n\u003chr data-start=\"1978\" data-end=\"1981\"\u003e\n\u003ch2 data-start=\"1983\" data-end=\"2003\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"2005\" data-end=\"2231\"\u003e✔ Three-phase industrial electrical panels\u003cbr data-start=\"2047\" data-end=\"2050\"\u003e✔ Low-voltage distribution systems\u003cbr data-start=\"2084\" data-end=\"2087\"\u003e✔ Motor line protection\u003cbr data-start=\"2110\" data-end=\"2113\"\u003e✔ Photovoltaic systems (with appropriate fuses)\u003cbr data-start=\"2160\" data-end=\"2163\"\u003e✔ Automation systems\u003cbr data-start=\"2183\" data-end=\"2186\"\u003e✔ Commercial and manufacturing environments\u003c\/p\u003e\n\u003chr data-start=\"2233\" data-end=\"2236\"\u003e\n\u003ch2 data-start=\"2238\" data-end=\"2258\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2260\" data-end=\"2458\"\u003e\n\u003cli data-start=\"2260\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2262\" data-end=\"2290\"\u003eStandard DIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2291\" data-end=\"2354\"\u003e\n\u003cp data-start=\"2293\" data-end=\"2354\"\u003eCopper conductor connection according to IEC specifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2355\" data-end=\"2397\"\u003e\n\u003cp data-start=\"2357\" data-end=\"2397\"\u003eSuitable for 10x38 mm fuses up to 32 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2398\" data-end=\"2458\"\u003e\n\u003cp data-start=\"2400\" data-end=\"2458\"\u003eTightening torque according to manufacturer instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2460\" data-end=\"2463\"\u003e\n\u003ch2 data-start=\"2465\" data-end=\"2482\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2484\" data-end=\"2576\"\u003eUsed product in good cosmetic and structural condition.\u003cbr data-start=\"2539\" data-end=\"2542\"\u003eSupplied as shown in the images.\u003c\/p\u003e\n\u003chr data-start=\"2578\" data-end=\"2581\"\u003e\n\u003ch2 data-start=\"2583\" data-end=\"2600\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cp data-start=\"2602\" data-end=\"2806\"\u003e✔ German Wöhner manufacturing quality\u003cbr data-start=\"2639\" data-end=\"2642\"\u003e✔ Rated voltage up to 690 V AC\u003cbr data-start=\"2672\" data-end=\"2675\"\u003e✔ Compact three-pole configuration\u003cbr data-start=\"2709\" data-end=\"2712\"\u003e✔ High industrial reliability\u003cbr data-start=\"2741\" data-end=\"2744\"\u003e✔ Easy maintenance\u003cbr data-start=\"2762\" data-end=\"2765\"\u003e✔ Ideal for three-phase line protection\u003c\/p\u003e","brand":"Wöhner","offers":[{"title":"Default Title","offer_id":53426043224397,"sku":null,"price":15.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4898.jpg?v=1772012938"},{"product_id":"bticino-f84-4-40-bticino-g44-63as-4-pole-rcbo-assembly-40a-curve-c-400v-ac-idn-0-3a-type-ac-6ka","title":"BTicino F84\/4\/40 + BTicino G44\/63AS – 4-Pole RCBO Assembly 40A Curve C | 400V AC | Idn 0.3A | Type AC | 6kA","description":"\u003cp data-start=\"186\" data-end=\"464\"\u003eThis assembly consists of a \u003cstrong data-start=\"214\" data-end=\"273\"\u003eBTicino F84\/4\/40 4-pole miniature circuit breaker (MCB)\u003c\/strong\u003e combined with a \u003cstrong data-start=\"290\" data-end=\"346\"\u003eBTicino G44\/63AS residual current block (RCD module)\u003c\/strong\u003e, forming a complete \u003cstrong data-start=\"367\" data-end=\"426\"\u003emagnetothermal and residual current protection solution\u003c\/strong\u003e for three-phase systems with neutral.\u003c\/p\u003e\n\u003cp data-start=\"466\" data-end=\"493\"\u003eThe combined unit provides:\u003c\/p\u003e\n\u003cul data-start=\"495\" data-end=\"595\"\u003e\n\u003cli data-start=\"495\" data-end=\"518\"\u003e\n\u003cp data-start=\"497\" data-end=\"518\"\u003eOverload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"519\" data-end=\"547\"\u003e\n\u003cp data-start=\"521\" data-end=\"547\"\u003eShort-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"548\" data-end=\"595\"\u003e\n\u003cp data-start=\"550\" data-end=\"595\"\u003eEarth leakage (residual current) protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"597\" data-end=\"746\"\u003eIt is particularly suitable for advanced residential switchboards and industrial distribution panels where reliable four-pole protection is required.\u003c\/p\u003e\n\u003cp data-start=\"748\" data-end=\"956\"\u003eWith a \u003cstrong data-start=\"755\" data-end=\"808\"\u003erated residual operating current of 300 mA (0.3A)\u003c\/strong\u003e, this device is especially appropriate as a \u003cstrong data-start=\"853\" data-end=\"888\"\u003emain upstream protection device\u003c\/strong\u003e, contributing to fire prevention in the event of insulation faults.\u003c\/p\u003e\n\u003chr data-start=\"958\" data-end=\"961\"\u003e\n\u003ch2 data-start=\"963\" data-end=\"995\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-start=\"997\" data-end=\"1035\"\u003e🔹 Miniature Circuit Breaker (MCB)\u003c\/h3\u003e\n\u003cp data-start=\"1037\" data-end=\"1255\"\u003e\u003cstrong data-start=\"1037\" data-end=\"1047\"\u003eBrand:\u003c\/strong\u003e BTicino\u003cbr data-start=\"1055\" data-end=\"1058\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1068\"\u003eModel:\u003c\/strong\u003e F84\/4\/40\u003cbr data-start=\"1077\" data-end=\"1080\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1100\"\u003eNumber of poles:\u003c\/strong\u003e 4P (3P + N)\u003cbr data-start=\"1112\" data-end=\"1115\"\u003e\u003cstrong data-start=\"1115\" data-end=\"1138\"\u003eRated current (In):\u003c\/strong\u003e 40 A\u003cbr data-start=\"1143\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1165\"\u003eTripping curve:\u003c\/strong\u003e C\u003cbr data-start=\"1167\" data-end=\"1170\"\u003e\u003cstrong data-start=\"1170\" data-end=\"1188\"\u003eRated voltage:\u003c\/strong\u003e 400 V AC\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e\u003cstrong data-start=\"1200\" data-end=\"1222\"\u003eBreaking capacity:\u003c\/strong\u003e 6 kA\u003cbr data-start=\"1227\" data-end=\"1230\"\u003e\u003cstrong data-start=\"1230\" data-end=\"1244\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003chr data-start=\"1257\" data-end=\"1260\"\u003e\n\u003ch3 data-start=\"1262\" data-end=\"1304\"\u003e🔹 Residual Current Block (RCD Module)\u003c\/h3\u003e\n\u003cp data-start=\"1306\" data-end=\"1512\"\u003e\u003cstrong data-start=\"1306\" data-end=\"1316\"\u003eModel:\u003c\/strong\u003e G44\/63AS\u003cbr data-start=\"1325\" data-end=\"1328\"\u003e\u003cstrong data-start=\"1328\" data-end=\"1356\"\u003eRated current supported:\u003c\/strong\u003e 63 A\u003cbr data-start=\"1361\" data-end=\"1364\"\u003e\u003cstrong data-start=\"1364\" data-end=\"1407\"\u003eRated residual operating current (Idn):\u003c\/strong\u003e 0.3 A (300 mA)\u003cbr data-start=\"1422\" data-end=\"1425\"\u003e\u003cstrong data-start=\"1425\" data-end=\"1434\"\u003eType:\u003c\/strong\u003e AC\u003cbr data-start=\"1437\" data-end=\"1440\"\u003e\u003cstrong data-start=\"1440\" data-end=\"1456\"\u003eTest button:\u003c\/strong\u003e Present\u003cbr data-start=\"1464\" data-end=\"1467\"\u003e\u003cstrong data-start=\"1467\" data-end=\"1489\"\u003eStatus indication:\u003c\/strong\u003e Dedicated blue lever\u003c\/p\u003e\n\u003chr data-start=\"1514\" data-end=\"1517\"\u003e\n\u003ch2 data-start=\"1519\" data-end=\"1539\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1541\" data-end=\"1729\"\u003e✔ Three-phase electrical panels\u003cbr data-start=\"1572\" data-end=\"1575\"\u003e✔ Industrial installations\u003cbr data-start=\"1601\" data-end=\"1604\"\u003e✔ Main distribution lines\u003cbr data-start=\"1629\" data-end=\"1632\"\u003e✔ Feeder protection\u003cbr data-start=\"1651\" data-end=\"1654\"\u003e✔ Commercial buildings\u003cbr data-start=\"1676\" data-end=\"1679\"\u003e✔ Upstream protection of sub-distribution boards\u003c\/p\u003e\n\u003cp data-start=\"1731\" data-end=\"1864\"\u003eThe \u003cstrong data-start=\"1735\" data-end=\"1764\"\u003e300 mA residual threshold\u003c\/strong\u003e makes this device particularly suitable for general fire protection against earth leakage currents.\u003c\/p\u003e\n\u003chr data-start=\"1866\" data-end=\"1869\"\u003e\n\u003ch2 data-start=\"1871\" data-end=\"1899\"\u003e🔒 Protection Functions\u003c\/h2\u003e\n\u003cp data-start=\"1901\" data-end=\"2087\"\u003e✔ Thermal protection against overloads\u003cbr data-start=\"1939\" data-end=\"1942\"\u003e✔ Magnetic protection against short circuits\u003cbr data-start=\"1986\" data-end=\"1989\"\u003e✔ Residual current protection against earth faults\u003cbr data-start=\"2039\" data-end=\"2042\"\u003e✔ Simultaneous disconnection of all 4 poles\u003c\/p\u003e\n\u003chr data-start=\"2089\" data-end=\"2092\"\u003e\n\u003ch2 data-start=\"2094\" data-end=\"2114\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2116\" data-end=\"2267\"\u003e\n\u003cli data-start=\"2116\" data-end=\"2137\"\u003e\n\u003cp data-start=\"2118\" data-end=\"2137\"\u003eDIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2138\" data-end=\"2168\"\u003e\n\u003cp data-start=\"2140\" data-end=\"2168\"\u003eScrew terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2169\" data-end=\"2212\"\u003e\n\u003cp data-start=\"2171\" data-end=\"2212\"\u003eCompatible with BTicino modular systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2213\" data-end=\"2267\"\u003e\n\u003cp data-start=\"2215\" data-end=\"2267\"\u003eDirect integration of MCB + residual current block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2269\" data-end=\"2272\"\u003e\n\u003ch2 data-start=\"2274\" data-end=\"2291\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2293\" data-end=\"2423\"\u003eUsed product in good cosmetic condition.\u003cbr data-start=\"2333\" data-end=\"2336\"\u003eElectrical functionality not tested at this stage.\u003cbr data-start=\"2386\" data-end=\"2389\"\u003eSupplied as shown in the images.\u003c\/p\u003e\n\u003chr data-start=\"2425\" data-end=\"2428\"\u003e\n\u003ch2 data-start=\"2430\" data-end=\"2447\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cp data-start=\"2449\" data-end=\"2645\"\u003e✔ Compact combined protection system\u003cbr data-start=\"2485\" data-end=\"2488\"\u003e✔ Complete 4-pole protection\u003cbr data-start=\"2516\" data-end=\"2519\"\u003e✔ High BTicino build quality\u003cbr data-start=\"2547\" data-end=\"2550\"\u003e✔ Suitable as a three-phase main breaker\u003cbr data-start=\"2590\" data-end=\"2593\"\u003e✔ Integrated TEST button for periodic verification\u003c\/p\u003e","brand":"BTicino","offers":[{"title":"Default Title","offer_id":53426504237389,"sku":null,"price":60.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4912.jpg?v=1772013992"},{"product_id":"bticino-f82-32-2-pole-mcb-32a-curve-c-400v-ac-6ka-btdin60-series-bipolar-miniature-circuit-breaker","title":"BTicino F82\/32 – 2-Pole MCB 32A Curve C | 400V AC | 6kA | btdin60 Series | Bipolar Miniature Circuit Breaker","description":"\u003cp data-start=\"187\" data-end=\"421\"\u003eThe \u003cstrong data-start=\"191\" data-end=\"209\"\u003eBTicino F82\/32\u003c\/strong\u003e is a \u003cstrong data-start=\"215\" data-end=\"267\"\u003e2-pole (bipolar) miniature circuit breaker (MCB)\u003c\/strong\u003e from the \u003cstrong data-start=\"277\" data-end=\"295\"\u003ebtdin60 series\u003c\/strong\u003e, designed to protect electrical lines against overloads and short circuits in residential and light industrial installations.\u003c\/p\u003e\n\u003cp data-start=\"423\" data-end=\"654\"\u003eWith a \u003cstrong data-start=\"430\" data-end=\"454\"\u003erated current of 32A\u003c\/strong\u003e and \u003cstrong data-start=\"459\" data-end=\"479\"\u003eC tripping curve\u003c\/strong\u003e, this breaker is particularly suitable for circuits with mixed loads or moderate inrush currents, such as small motors, industrial sockets, and secondary distribution boards.\u003c\/p\u003e\n\u003cp data-start=\"656\" data-end=\"830\"\u003eIts compact modular design allows easy \u003cstrong data-start=\"695\" data-end=\"720\"\u003eDIN rail installation\u003c\/strong\u003e, ensuring reliability, operational safety, and straightforward maintenance within standard electrical panels.\u003c\/p\u003e\n\u003chr data-start=\"832\" data-end=\"835\"\u003e\n\u003ch2 data-start=\"837\" data-end=\"869\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"871\" data-end=\"1144\"\u003e\u003cstrong data-start=\"871\" data-end=\"881\"\u003eBrand:\u003c\/strong\u003e BTicino\u003cbr data-start=\"889\" data-end=\"892\"\u003e\u003cstrong data-start=\"892\" data-end=\"902\"\u003eModel:\u003c\/strong\u003e F82\/32\u003cbr data-start=\"909\" data-end=\"912\"\u003e\u003cstrong data-start=\"912\" data-end=\"923\"\u003eSeries:\u003c\/strong\u003e btdin60\u003cbr data-start=\"931\" data-end=\"934\"\u003e\u003cstrong data-start=\"934\" data-end=\"954\"\u003eNumber of poles:\u003c\/strong\u003e 2P (bipolar)\u003cbr data-start=\"967\" data-end=\"970\"\u003e\u003cstrong data-start=\"970\" data-end=\"993\"\u003eRated current (In):\u003c\/strong\u003e 32 A\u003cbr data-start=\"998\" data-end=\"1001\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1020\"\u003eTripping curve:\u003c\/strong\u003e C\u003cbr data-start=\"1022\" data-end=\"1025\"\u003e\u003cstrong data-start=\"1025\" data-end=\"1043\"\u003eRated voltage:\u003c\/strong\u003e 400 V AC\u003cbr data-start=\"1052\" data-end=\"1055\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1077\"\u003eBreaking capacity:\u003c\/strong\u003e 6 kA (6000 A)\u003cbr data-start=\"1091\" data-end=\"1094\"\u003e\u003cstrong data-start=\"1094\" data-end=\"1108\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003cbr data-start=\"1117\" data-end=\"1120\"\u003e\u003cstrong data-start=\"1120\" data-end=\"1133\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003ch3 data-start=\"1146\" data-end=\"1170\"\u003e🔒 Protection Type\u003c\/h3\u003e\n\u003cul data-start=\"1172\" data-end=\"1245\"\u003e\n\u003cli data-start=\"1172\" data-end=\"1205\"\u003e\n\u003cp data-start=\"1174\" data-end=\"1205\"\u003eThermal protection (overload)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1206\" data-end=\"1245\"\u003e\n\u003cp data-start=\"1208\" data-end=\"1245\"\u003eMagnetic protection (short circuit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1247\" data-end=\"1303\"\u003e\u003cstrong data-start=\"1247\" data-end=\"1268\"\u003eOperating handle:\u003c\/strong\u003e Black lever with I-ON indication\u003c\/p\u003e\n\u003chr data-start=\"1305\" data-end=\"1308\"\u003e\n\u003ch2 data-start=\"1310\" data-end=\"1338\"\u003e🔒 Protection Functions\u003c\/h2\u003e\n\u003cp data-start=\"1340\" data-end=\"1496\"\u003e✔ Protection against prolonged overloads\u003cbr data-start=\"1380\" data-end=\"1383\"\u003e✔ Fast response to short circuits\u003cbr data-start=\"1416\" data-end=\"1419\"\u003e✔ Simultaneous disconnection of both poles\u003cbr data-start=\"1461\" data-end=\"1464\"\u003e✔ Certified operational safety\u003c\/p\u003e\n\u003chr data-start=\"1498\" data-end=\"1501\"\u003e\n\u003ch2 data-start=\"1503\" data-end=\"1523\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1525\" data-end=\"1692\"\u003e✔ Residential electrical panels\u003cbr data-start=\"1556\" data-end=\"1559\"\u003e✔ Socket outlet circuits\u003cbr data-start=\"1583\" data-end=\"1586\"\u003e✔ Light industrial installations\u003cbr data-start=\"1618\" data-end=\"1621\"\u003e✔ Single-phase 230V line protection\u003cbr data-start=\"1656\" data-end=\"1659\"\u003e✔ Secondary distribution boards\u003c\/p\u003e","brand":"BTicino","offers":[{"title":"Default Title","offer_id":53426505154893,"sku":null,"price":20.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4920.jpg?v=1772015755"},{"product_id":"abb-s201-c6-1p-6a-curve-c-mcb-230-400v-ac-6ka-s200-series-single-pole-miniature-circuit-breaker","title":"ABB S201 C6 – 1P 6A Curve C MCB | 230\/400V AC | 6kA | S200 Series | Single-Pole Miniature Circuit Breaker","description":"\u003cp data-start=\"184\" data-end=\"436\"\u003eThe \u003cstrong data-start=\"188\" data-end=\"203\"\u003eABB S201 C6\u003c\/strong\u003e is a \u003cstrong data-start=\"209\" data-end=\"256\"\u003esingle-pole miniature circuit breaker (MCB)\u003c\/strong\u003e from the professional \u003cstrong data-start=\"279\" data-end=\"294\"\u003eS200 series\u003c\/strong\u003e, designed to protect electrical circuits against overloads and short circuits in residential, commercial, and light industrial installations.\u003c\/p\u003e\n\u003cp data-start=\"438\" data-end=\"646\"\u003eWith a \u003cstrong data-start=\"445\" data-end=\"468\"\u003erated current of 6A\u003c\/strong\u003e and \u003cstrong data-start=\"473\" data-end=\"493\"\u003eC tripping curve\u003c\/strong\u003e, this device is ideal for protecting light-load circuits with moderate inrush currents, such as lighting lines, auxiliary circuits, and control systems.\u003c\/p\u003e\n\u003cp data-start=\"648\" data-end=\"785\"\u003eABB’s high manufacturing standards ensure excellent reliability, long operational life, and full compliance with international standards.\u003c\/p\u003e\n\u003chr data-start=\"787\" data-end=\"790\"\u003e\n\u003ch2 data-start=\"792\" data-end=\"824\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"826\" data-end=\"1182\"\u003e\u003cstrong data-start=\"826\" data-end=\"836\"\u003eBrand:\u003c\/strong\u003e ABB\u003cbr data-start=\"840\" data-end=\"843\"\u003e\u003cstrong data-start=\"843\" data-end=\"853\"\u003eModel:\u003c\/strong\u003e S201\u003cbr data-start=\"858\" data-end=\"861\"\u003e\u003cstrong data-start=\"861\" data-end=\"872\"\u003eSeries:\u003c\/strong\u003e S200\u003cbr data-start=\"877\" data-end=\"880\"\u003e\u003cstrong data-start=\"880\" data-end=\"903\"\u003eRated current (In):\u003c\/strong\u003e 6 A\u003cbr data-start=\"907\" data-end=\"910\"\u003e\u003cstrong data-start=\"910\" data-end=\"929\"\u003eTripping curve:\u003c\/strong\u003e C\u003cbr data-start=\"931\" data-end=\"934\"\u003e\u003cstrong data-start=\"934\" data-end=\"954\"\u003eNumber of poles:\u003c\/strong\u003e 1P (single-pole)\u003cbr data-start=\"971\" data-end=\"974\"\u003e\u003cstrong data-start=\"974\" data-end=\"992\"\u003eRated voltage:\u003c\/strong\u003e 230\/400 V AC\u003cbr data-start=\"1005\" data-end=\"1008\"\u003e\u003cstrong data-start=\"1008\" data-end=\"1030\"\u003eBreaking capacity:\u003c\/strong\u003e 6 kA (6000 A)\u003cbr data-start=\"1044\" data-end=\"1047\"\u003e\u003cstrong data-start=\"1047\" data-end=\"1061\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003cbr data-start=\"1070\" data-end=\"1073\"\u003e\u003cstrong data-start=\"1073\" data-end=\"1086\"\u003eMounting:\u003c\/strong\u003e DIN rail (35 mm)\u003cbr data-start=\"1103\" data-end=\"1106\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1127\"\u003eOperating handle:\u003c\/strong\u003e Front lever with ON\/OFF indication\u003cbr data-start=\"1162\" data-end=\"1165\"\u003e\u003cstrong data-start=\"1165\" data-end=\"1177\" data-is-only-node=\"\"\u003eMarking:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003chr data-start=\"1184\" data-end=\"1187\"\u003e\n\u003ch2 data-start=\"1189\" data-end=\"1217\"\u003e🔒 Protection Functions\u003c\/h2\u003e\n\u003cp data-start=\"1219\" data-end=\"1390\"\u003e✔ Thermal protection against prolonged overloads\u003cbr data-start=\"1267\" data-end=\"1270\"\u003e✔ Magnetic protection against short circuits\u003cbr data-start=\"1314\" data-end=\"1317\"\u003e✔ Safe circuit isolation\u003cbr data-start=\"1341\" data-end=\"1344\"\u003e✔ High mechanical and electrical reliability\u003c\/p\u003e\n\u003chr data-start=\"1392\" data-end=\"1395\"\u003e\n\u003ch2 data-start=\"1397\" data-end=\"1417\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1419\" data-end=\"1552\"\u003e✔ Lighting circuits\u003cbr data-start=\"1438\" data-end=\"1441\"\u003e✔ Auxiliary lines\u003cbr data-start=\"1458\" data-end=\"1461\"\u003e✔ Residential electrical panels\u003cbr data-start=\"1492\" data-end=\"1495\"\u003e✔ Light industrial installations\u003cbr data-start=\"1527\" data-end=\"1530\"\u003e✔ Automation systems\u003c\/p\u003e\n\u003cp data-start=\"1554\" data-end=\"1641\"\u003eThe \u003cstrong data-start=\"1558\" data-end=\"1584\"\u003eC curve characteristic\u003c\/strong\u003e allows use with loads that have small starting currents.\u003c\/p\u003e\n\u003chr data-start=\"1643\" data-end=\"1646\"\u003e\n\u003ch2 data-start=\"1648\" data-end=\"1668\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1670\" data-end=\"1786\"\u003e\n\u003cli data-start=\"1670\" data-end=\"1709\"\u003e\n\u003cp data-start=\"1672\" data-end=\"1709\"\u003eMounting on standard 35 mm DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1740\"\u003e\n\u003cp data-start=\"1712\" data-end=\"1740\"\u003eScrew terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1741\" data-end=\"1786\"\u003e\n\u003cp data-start=\"1743\" data-end=\"1786\"\u003eFully compatible with ABB modular systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53426512691533,"sku":null,"price":7.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4924.jpg?v=1772016996"},{"product_id":"schneider-electric-sw60-dc-63a-4-pole-dc-switch-disconnector-63a-1000v-dc-dc-21a-iec-en-60947-3-multi-9","title":"Schneider Electric SW60-DC 63A – 4-Pole DC Switch Disconnector 63A | 1000V DC | DC-21A | IEC\/EN 60947-3 | Multi 9","description":"\u003cp data-start=\"207\" data-end=\"527\"\u003eThe \u003cstrong data-start=\"211\" data-end=\"245\"\u003eSchneider Electric SW60-DC 63A\u003c\/strong\u003e is a \u003cstrong data-start=\"251\" data-end=\"284\"\u003e4-pole DC switch disconnector\u003c\/strong\u003e designed for applications up to \u003cstrong data-start=\"317\" data-end=\"330\"\u003e1000 V DC\u003c\/strong\u003e. Part of the professional \u003cstrong data-start=\"357\" data-end=\"398\"\u003eMulti 9 range (formerly Merlin Gerin)\u003c\/strong\u003e, it is specifically engineered for photovoltaic systems and high-voltage DC installations requiring safe and reliable isolation.\u003c\/p\u003e\n\u003cp data-start=\"529\" data-end=\"787\"\u003eThe device allows \u003cstrong data-start=\"547\" data-end=\"596\"\u003eload switching in DC-21A utilization category\u003c\/strong\u003e, ensuring high operational safety and robust mechanical performance. The \u003cstrong data-start=\"670\" data-end=\"694\"\u003e4-pole configuration\u003c\/strong\u003e enables simultaneous isolation of multiple strings or conductors in high-voltage DC systems.\u003c\/p\u003e\n\u003cp data-start=\"789\" data-end=\"900\"\u003e⚠ This device is a \u003cstrong data-start=\"808\" data-end=\"836\"\u003eswitch disconnector only\u003c\/strong\u003e – it does \u003cstrong data-start=\"847\" data-end=\"854\"\u003enot\u003c\/strong\u003e provide overload or short-circuit protection.\u003c\/p\u003e\n\u003chr data-start=\"902\" data-end=\"905\"\u003e\n\u003ch2 data-start=\"907\" data-end=\"939\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"941\" data-end=\"1402\"\u003e\u003cstrong data-start=\"941\" data-end=\"951\"\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003cbr data-start=\"970\" data-end=\"973\"\u003e\u003cstrong data-start=\"973\" data-end=\"984\"\u003eSeries:\u003c\/strong\u003e SW60-DC (Multi 9 \/ Merlin Gerin)\u003cbr data-start=\"1017\" data-end=\"1020\"\u003e\u003cstrong data-start=\"1020\" data-end=\"1036\"\u003eDevice Type:\u003c\/strong\u003e DC switch disconnector\u003cbr data-start=\"1059\" data-end=\"1062\"\u003e\u003cstrong data-start=\"1062\" data-end=\"1082\"\u003eNumber of poles:\u003c\/strong\u003e 4P\u003cbr data-start=\"1085\" data-end=\"1088\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1111\"\u003eRated current (In):\u003c\/strong\u003e 63 A\u003cbr data-start=\"1116\" data-end=\"1119\"\u003e\u003cstrong data-start=\"1119\" data-end=\"1154\"\u003eRated operational voltage (Ui):\u003c\/strong\u003e 1000 V DC\u003cbr data-start=\"1164\" data-end=\"1167\"\u003e\u003cstrong data-start=\"1167\" data-end=\"1192\"\u003eUtilization category:\u003c\/strong\u003e DC-21A\u003cbr data-start=\"1199\" data-end=\"1202\"\u003e\u003cstrong data-start=\"1202\" data-end=\"1239\"\u003eImpulse withstand voltage (Uimp):\u003c\/strong\u003e 6 kV\u003cbr data-start=\"1244\" data-end=\"1247\"\u003e\u003cstrong data-start=\"1247\" data-end=\"1260\"\u003eStandard:\u003c\/strong\u003e IEC \/ EN 60947-3\u003cbr data-start=\"1277\" data-end=\"1280\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1308\"\u003eConductor cross-section:\u003c\/strong\u003e 1 – 35 mm²\u003cbr data-start=\"1319\" data-end=\"1322\"\u003e\u003cstrong data-start=\"1322\" data-end=\"1344\"\u003eTightening torque:\u003c\/strong\u003e 3.5 Nm\u003cbr data-start=\"1351\" data-end=\"1354\"\u003e\u003cstrong data-start=\"1354\" data-end=\"1367\"\u003eMounting:\u003c\/strong\u003e DIN rail 35 mm\u003cbr data-start=\"1382\" data-end=\"1385\"\u003e\u003cstrong data-start=\"1385\" data-end=\"1397\"\u003eMarking:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003cp data-start=\"1404\" data-end=\"1472\"\u003e⚠ Clear polarity indication \u003cstrong data-start=\"1432\" data-end=\"1443\"\u003eL+ \/ L-\u003c\/strong\u003e for correct DC installation.\u003c\/p\u003e\n\u003chr data-start=\"1474\" data-end=\"1477\"\u003e\n\u003ch2 data-start=\"1479\" data-end=\"1495\"\u003e🔒 Function\u003c\/h2\u003e\n\u003cp data-start=\"1497\" data-end=\"1510\"\u003eDesigned for:\u003c\/p\u003e\n\u003cp data-start=\"1512\" data-end=\"1658\"\u003e✔ DC line isolation\u003cbr data-start=\"1531\" data-end=\"1534\"\u003e✔ Photovoltaic string disconnection\u003cbr data-start=\"1569\" data-end=\"1572\"\u003e✔ Load switching in DC-21A category\u003cbr data-start=\"1607\" data-end=\"1610\"\u003e✔ Safe interruption in systems up to 1000 V DC\u003c\/p\u003e\n\u003cp data-start=\"1660\" data-end=\"1754\"\u003eThis unit ensures secure manual disconnection of DC circuits in compliance with IEC standards.\u003c\/p\u003e\n\u003chr data-start=\"1756\" data-end=\"1759\"\u003e\n\u003ch2 data-start=\"1761\" data-end=\"1781\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1783\" data-end=\"1941\"\u003e✔ Photovoltaic installations (string isolation)\u003cbr data-start=\"1830\" data-end=\"1833\"\u003e✔ DC combiner boxes\u003cbr data-start=\"1852\" data-end=\"1855\"\u003e✔ Energy storage systems\u003cbr data-start=\"1879\" data-end=\"1882\"\u003e✔ Industrial DC systems\u003cbr data-start=\"1905\" data-end=\"1908\"\u003e✔ Inverter DC-side applications\u003c\/p\u003e\n\u003chr data-start=\"1943\" data-end=\"1946\"\u003e\n\u003ch2 data-start=\"1948\" data-end=\"1968\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1970\" data-end=\"2176\"\u003e\n\u003cli data-start=\"1970\" data-end=\"2009\"\u003e\n\u003cp data-start=\"1972\" data-end=\"2009\"\u003eMounting on standard 35 mm DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2010\" data-end=\"2054\"\u003e\n\u003cp data-start=\"2012\" data-end=\"2054\"\u003eConnection respecting indicated polarity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2055\" data-end=\"2115\"\u003e\n\u003cp data-start=\"2057\" data-end=\"2115\"\u003eInstallation inside suitably rated electrical enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2116\" data-end=\"2176\"\u003e\n\u003cp data-start=\"2118\" data-end=\"2176\"\u003eCompliant with IEC standards for DC switch disconnectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2178\" data-end=\"2181\"\u003e\n\u003ch2 data-start=\"2183\" data-end=\"2200\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2202\" data-end=\"2284\"\u003eUsed product in good cosmetic condition.\u003cbr data-start=\"2242\" data-end=\"2245\"\u003eSupplied as shown in the photographs.\u003c\/p\u003e\n\u003chr data-start=\"2286\" data-end=\"2289\"\u003e\n\u003ch2 data-start=\"2291\" data-end=\"2314\"\u003e📦 Scope of Supply\u003c\/h2\u003e\n\u003cul data-start=\"2316\" data-end=\"2376\"\u003e\n\u003cli data-start=\"2316\" data-end=\"2376\"\u003e\n\u003cp data-start=\"2318\" data-end=\"2376\"\u003e1x Schneider Electric SW60-DC 63A 4P switch disconnector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2378\" data-end=\"2381\"\u003e\n\u003ch2 data-start=\"2383\" data-end=\"2409\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2411\" data-end=\"2689\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eA professional 63A DC switch disconnector rated up to 1000V DC, featuring 4-pole isolation and DC-21A load switching capability. The Schneider Electric SW60-DC offers a reliable and standards-compliant solution for safe disconnection in photovoltaic and high-voltage DC systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53459592446285,"sku":null,"price":80.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5069.jpg?v=1772529684"},{"product_id":"moeller-xpole-pls4-c6-mw-1p-6a-curve-c-mcb-4-5ka-230-400v-ac-xpole-series-code-243176-iec-en-60898","title":"Moeller Xpole PLS4-C6-MW – 1P 6A Curve C MCB | 4.5kA | 230\/400V AC | Xpole Series | Code 243176 | IEC\/EN 60898","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"18c2525a-7bd9-401e-aa1e-68fc0089976a\" data-testid=\"conversation-turn-40\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"18c2525a-7bd9-401e-aa1e-68fc0089976a\" dir=\"auto\" data-message-model-slug=\"gpt-5-2\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-start=\"189\" data-end=\"401\"\u003eThe \u003cstrong data-start=\"193\" data-end=\"221\"\u003eMoeller Xpole PLS4-C6-MW\u003c\/strong\u003e is a \u003cstrong data-start=\"227\" data-end=\"282\"\u003esingle-pole modular miniature circuit breaker (MCB)\u003c\/strong\u003e designed to protect electrical lines against overloads and short circuits in residential and industrial installations.\u003c\/p\u003e\n\u003cp data-start=\"403\" data-end=\"642\"\u003ePart of the \u003cstrong data-start=\"415\" data-end=\"431\"\u003eXpole series\u003c\/strong\u003e, this device ensures high operational reliability, long mechanical life, and full compliance with international standards. Originally manufactured by Moeller (Austria), the brand is now part of the Eaton group.\u003c\/p\u003e\n\u003cp data-start=\"644\" data-end=\"824\"\u003eWith a \u003cstrong data-start=\"651\" data-end=\"674\"\u003erated current of 6A\u003c\/strong\u003e and \u003cstrong data-start=\"679\" data-end=\"699\"\u003eC tripping curve\u003c\/strong\u003e, it is suitable for circuits with moderate inrush currents, offering dependable protection for a wide range of applications.\u003c\/p\u003e\n\u003chr data-start=\"826\" data-end=\"829\"\u003e\n\u003ch2 data-start=\"831\" data-end=\"863\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"865\" data-end=\"1392\"\u003e\u003cstrong data-start=\"865\" data-end=\"875\"\u003eBrand:\u003c\/strong\u003e Moeller\u003cbr data-start=\"883\" data-end=\"886\"\u003e\u003cstrong data-start=\"886\" data-end=\"897\"\u003eSeries:\u003c\/strong\u003e Xpole\u003cbr data-start=\"903\" data-end=\"906\"\u003e\u003cstrong data-start=\"906\" data-end=\"916\"\u003eModel:\u003c\/strong\u003e PLS4-C6-MW\u003cbr data-start=\"927\" data-end=\"930\"\u003e\u003cstrong data-start=\"930\" data-end=\"947\"\u003eProduct Code:\u003c\/strong\u003e 243176\u003cbr data-start=\"954\" data-end=\"957\"\u003e\u003cstrong data-start=\"957\" data-end=\"966\"\u003eType:\u003c\/strong\u003e Miniature Circuit Breaker (MCB)\u003cbr data-start=\"998\" data-end=\"1001\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1021\"\u003eNumber of poles:\u003c\/strong\u003e 1P\u003cbr data-start=\"1024\" data-end=\"1027\"\u003e\u003cstrong data-start=\"1027\" data-end=\"1050\"\u003eRated current (In):\u003c\/strong\u003e 6 A\u003cbr data-start=\"1054\" data-end=\"1057\"\u003e\u003cstrong data-start=\"1057\" data-end=\"1076\"\u003eTripping curve:\u003c\/strong\u003e C\u003cbr data-start=\"1078\" data-end=\"1081\"\u003e\u003cstrong data-start=\"1081\" data-end=\"1103\"\u003eBreaking capacity:\u003c\/strong\u003e 4.5 kA\u003cbr data-start=\"1110\" data-end=\"1113\"\u003e\u003cstrong data-start=\"1113\" data-end=\"1131\"\u003eRated voltage:\u003c\/strong\u003e 230\/400 V AC\u003cbr data-start=\"1144\" data-end=\"1147\"\u003e\u003cstrong data-start=\"1147\" data-end=\"1160\"\u003eStandard:\u003c\/strong\u003e IEC\/EN 60898\u003cbr data-start=\"1173\" data-end=\"1176\"\u003e\u003cstrong data-start=\"1176\" data-end=\"1189\"\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail\u003cbr data-start=\"1204\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1207\" data-end=\"1235\"\u003eConductor cross-section:\u003c\/strong\u003e up to 25 mm² (depending on installation standards)\u003cbr data-start=\"1286\" data-end=\"1289\"\u003e\u003cstrong data-start=\"1289\" data-end=\"1316\"\u003eCountry of manufacture:\u003c\/strong\u003e Austria\u003cbr data-start=\"1324\" data-end=\"1327\"\u003e\u003cstrong data-start=\"1327\" data-end=\"1340\"\u003eMarkings:\u003c\/strong\u003e CE and international approvals (ÖVE, CEBEC, etc.)\u003c\/p\u003e\n\u003chr data-start=\"1394\" data-end=\"1397\"\u003e\n\u003ch2 data-start=\"1399\" data-end=\"1426\"\u003e🔎 Operating Principle\u003c\/h2\u003e\n\u003cp data-start=\"1428\" data-end=\"1465\"\u003eThe breaker provides dual protection:\u003c\/p\u003e\n\u003cul data-start=\"1467\" data-end=\"1572\"\u003e\n\u003cli data-start=\"1467\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1469\" data-end=\"1521\"\u003e\u003cstrong data-start=\"1469\" data-end=\"1491\"\u003eThermal protection\u003c\/strong\u003e against prolonged overloads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1522\" data-end=\"1572\"\u003e\n\u003cp data-start=\"1524\" data-end=\"1572\"\u003e\u003cstrong data-start=\"1524\" data-end=\"1547\"\u003eMagnetic protection\u003c\/strong\u003e against short circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1574\" data-end=\"1674\"\u003eThe \u003cstrong data-start=\"1578\" data-end=\"1604\"\u003eC curve characteristic\u003c\/strong\u003e makes it suitable for loads with moderate starting currents, such as:\u003c\/p\u003e\n\u003cp data-start=\"1676\" data-end=\"1776\"\u003e✔ Socket outlet circuits\u003cbr data-start=\"1700\" data-end=\"1703\"\u003e✔ Lighting lines\u003cbr data-start=\"1719\" data-end=\"1722\"\u003e✔ Small motors\u003cbr data-start=\"1736\" data-end=\"1739\"\u003e✔ Domestic and commercial equipment\u003c\/p\u003e\n\u003chr data-start=\"1778\" data-end=\"1781\"\u003e\n\u003ch2 data-start=\"1783\" data-end=\"1803\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1805\" data-end=\"1935\"\u003e✔ Residential electrical panels\u003cbr data-start=\"1836\" data-end=\"1839\"\u003e✔ Industrial sub-distribution boards\u003cbr data-start=\"1875\" data-end=\"1878\"\u003e✔ Commercial installations\u003cbr data-start=\"1904\" data-end=\"1907\"\u003e✔ Final circuit protection\u003c\/p\u003e\n\u003chr data-start=\"1937\" data-end=\"1940\"\u003e\n\u003ch2 data-start=\"1942\" data-end=\"1962\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1964\" data-end=\"2121\"\u003e\n\u003cli data-start=\"1964\" data-end=\"2007\"\u003e\n\u003cp data-start=\"1966\" data-end=\"2007\"\u003eQuick installation on standard DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2008\" data-end=\"2038\"\u003e\n\u003cp data-start=\"2010\" data-end=\"2038\"\u003eScrew terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2039\" data-end=\"2076\"\u003e\n\u003cp data-start=\"2041\" data-end=\"2076\"\u003eStandard modular width (1 module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2077\" data-end=\"2121\"\u003e\n\u003cp data-start=\"2079\" data-end=\"2121\"\u003eCompatible with Xpole series accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2123\" data-end=\"2126\"\u003e\n\u003ch2 data-start=\"2128\" data-end=\"2145\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2147\" data-end=\"2278\"\u003eUsed product in good cosmetic and functional condition.\u003cbr data-start=\"2202\" data-end=\"2205\"\u003eInspection by qualified personnel is recommended prior to installation.\u003c\/p\u003e\n\u003chr data-start=\"2280\" data-end=\"2283\"\u003e\n\u003ch2 data-start=\"2285\" data-end=\"2308\"\u003e📦 Scope of Supply\u003c\/h2\u003e\n\u003cul data-start=\"2310\" data-end=\"2373\"\u003e\n\u003cli data-start=\"2310\" data-end=\"2373\"\u003e\n\u003cp data-start=\"2312\" data-end=\"2373\"\u003e1x Moeller Xpole PLS4-C6-MW 6A 1P miniature circuit breaker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2375\" data-end=\"2378\"\u003e\n\u003ch2 data-start=\"2380\" data-end=\"2406\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2408\" data-end=\"2663\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eReliable 6A single-pole circuit breaker with C curve and 4.5 kA breaking capacity. The Moeller Xpole PLS4-C6-MW offers compact design, proven Austrian engineering, and IEC-compliant protection—ideal for residential and light industrial electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Moeller","offers":[{"title":"Default Title","offer_id":53459594936653,"sku":null,"price":10.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5066.jpg?v=1772530685"},{"product_id":"ferraz-shawmut-us101hel-1p-modular-fuse-holder-1000v-dc-32a-10x38-mm-modulo-star-series-iec-60947-3-ul-512","title":"Ferraz Shawmut US101HEL – 1P Modular Fuse Holder 1000V DC 32A | 10x38 mm | Modulo Star Series | IEC 60947-3 \/ UL 512","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"bf4d44cc-70c4-4c79-a3b5-0d4bd7ad8b45\" data-testid=\"conversation-turn-42\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"bf4d44cc-70c4-4c79-a3b5-0d4bd7ad8b45\" dir=\"auto\" data-message-model-slug=\"gpt-5-2\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-start=\"195\" data-end=\"406\"\u003eThe \u003cstrong data-start=\"199\" data-end=\"226\"\u003eFerraz Shawmut US101HEL\u003c\/strong\u003e is a \u003cstrong data-start=\"232\" data-end=\"267\"\u003esingle-pole modular fuse holder\u003c\/strong\u003e designed for \u003cstrong data-start=\"281\" data-end=\"316\"\u003eDC applications up to 1000 V DC\u003c\/strong\u003e, making it ideal for photovoltaic installations and high-voltage DC distribution systems.\u003c\/p\u003e\n\u003cp data-start=\"408\" data-end=\"659\"\u003ePart of the \u003cstrong data-start=\"420\" data-end=\"442\"\u003eModulo Star series\u003c\/strong\u003e by Ferraz Shawmut (now Mersen), this device is compatible with \u003cstrong data-start=\"506\" data-end=\"541\"\u003e10x38 mm cylindrical fuse links\u003c\/strong\u003e and ensures high electrical reliability and operational safety in compliance with international IEC and UL standards.\u003c\/p\u003e\n\u003cp data-start=\"661\" data-end=\"791\"\u003e⚠️ This is a \u003cstrong data-start=\"674\" data-end=\"709\"\u003efuse-switch disconnector device\u003c\/strong\u003e and must \u003cstrong data-start=\"719\" data-end=\"749\"\u003enot be operated under load\u003c\/strong\u003e, as clearly indicated on the front label.\u003c\/p\u003e\n\u003chr data-start=\"793\" data-end=\"796\"\u003e\n\u003ch2 data-start=\"798\" data-end=\"830\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"832\" data-end=\"1056\"\u003e\u003cstrong data-start=\"832\" data-end=\"842\"\u003eBrand:\u003c\/strong\u003e Ferraz Shawmut (Mersen)\u003cbr data-start=\"866\" data-end=\"869\"\u003e\u003cstrong data-start=\"869\" data-end=\"879\"\u003eModel:\u003c\/strong\u003e US101HEL\u003cbr data-start=\"888\" data-end=\"891\"\u003e\u003cstrong data-start=\"891\" data-end=\"902\"\u003eSeries:\u003c\/strong\u003e Modulo Star\u003cbr data-start=\"914\" data-end=\"917\"\u003e\u003cstrong data-start=\"917\" data-end=\"926\"\u003eType:\u003c\/strong\u003e Modular fuse holder\u003cbr data-start=\"946\" data-end=\"949\"\u003e\u003cstrong data-start=\"949\" data-end=\"969\"\u003eNumber of poles:\u003c\/strong\u003e 1P\u003cbr data-start=\"972\" data-end=\"975\"\u003e\u003cstrong data-start=\"975\" data-end=\"989\"\u003eFuse size:\u003c\/strong\u003e 10x38 mm\u003cbr data-start=\"998\" data-end=\"1001\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1014\"\u003eMounting:\u003c\/strong\u003e DIN rail 35 mm\u003cbr data-start=\"1029\" data-end=\"1032\"\u003e\u003cstrong data-start=\"1032\" data-end=\"1044\"\u003eMarking:\u003c\/strong\u003e CE, cURus\u003c\/p\u003e\n\u003ch3 data-start=\"1058\" data-end=\"1085\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1087\" data-end=\"1455\"\u003e\n\u003cli data-start=\"1087\" data-end=\"1119\"\u003e\n\u003cp data-start=\"1089\" data-end=\"1119\"\u003eRated voltage: \u003cstrong data-start=\"1104\" data-end=\"1117\"\u003e1000 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1120\" data-end=\"1153\"\u003e\n\u003cp data-start=\"1122\" data-end=\"1153\"\u003eRated current: \u003cstrong data-start=\"1137\" data-end=\"1151\"\u003eup to 32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1154\" data-end=\"1190\"\u003e\n\u003cp data-start=\"1156\" data-end=\"1190\"\u003eUtilization category: \u003cstrong data-start=\"1178\" data-end=\"1188\"\u003eDC-20B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1191\" data-end=\"1239\"\u003e\n\u003cp data-start=\"1193\" data-end=\"1239\"\u003eInterrupting rating (UL): \u003cstrong data-start=\"1219\" data-end=\"1237\"\u003e100 kA RMS Sym\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1273\"\u003e\n\u003cp data-start=\"1242\" data-end=\"1273\"\u003eDegree of protection: \u003cstrong data-start=\"1264\" data-end=\"1271\"\u003eIP2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1274\" data-end=\"1301\"\u003e\n\u003cp data-start=\"1276\" data-end=\"1301\"\u003ePollution degree: \u003cstrong data-start=\"1294\" data-end=\"1299\"\u003e2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1302\" data-end=\"1358\"\u003e\n\u003cp data-start=\"1304\" data-end=\"1358\"\u003eConductor cross-section: \u003cstrong data-start=\"1329\" data-end=\"1356\"\u003e1 – 16 mm² (18 – 6 AWG)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1359\" data-end=\"1404\"\u003e\n\u003cp data-start=\"1361\" data-end=\"1404\"\u003eTightening torque: \u003cstrong data-start=\"1380\" data-end=\"1402\"\u003e2.2 Nm (19 in-lbs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1405\" data-end=\"1455\"\u003e\n\u003cp data-start=\"1407\" data-end=\"1455\"\u003eConductor temperature rating: \u003cstrong data-start=\"1437\" data-end=\"1453\"\u003e75°C CU only\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1457\" data-end=\"1475\"\u003e📜 Standards\u003c\/h3\u003e\n\u003cul data-start=\"1477\" data-end=\"1503\"\u003e\n\u003cli data-start=\"1477\" data-end=\"1492\"\u003e\n\u003cp data-start=\"1479\" data-end=\"1492\"\u003eIEC 60947-3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1493\" data-end=\"1503\"\u003e\n\u003cp data-start=\"1495\" data-end=\"1503\"\u003eUL 512\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1505\" data-end=\"1508\"\u003e\n\u003ch2 data-start=\"1510\" data-end=\"1526\"\u003e🔎 Function\u003c\/h2\u003e\n\u003cp data-start=\"1528\" data-end=\"1548\"\u003eThe device allows:\u003c\/p\u003e\n\u003cp data-start=\"1550\" data-end=\"1735\"\u003e✔ Secure installation of 10x38 mm cylindrical fuses\u003cbr data-start=\"1601\" data-end=\"1604\"\u003e✔ Overcurrent protection in DC systems\u003cbr data-start=\"1642\" data-end=\"1645\"\u003e✔ Line isolation by fuse carrier removal\u003cbr data-start=\"1685\" data-end=\"1688\"\u003e✔ Use in photovoltaic systems up to 1000 V DC\u003c\/p\u003e\n\u003cp data-start=\"1737\" data-end=\"1812\"\u003e⚠️ Not a miniature circuit breaker.\u003cbr data-start=\"1772\" data-end=\"1775\"\u003e⚠️ Must not be switched under load.\u003c\/p\u003e\n\u003chr data-start=\"1814\" data-end=\"1817\"\u003e\n\u003ch2 data-start=\"1819\" data-end=\"1839\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1841\" data-end=\"2003\"\u003e✔ Photovoltaic installations (string protection)\u003cbr data-start=\"1889\" data-end=\"1892\"\u003e✔ DC combiner boxes\u003cbr data-start=\"1911\" data-end=\"1914\"\u003e✔ Energy storage systems\u003cbr data-start=\"1938\" data-end=\"1941\"\u003e✔ Industrial DC distribution\u003cbr data-start=\"1969\" data-end=\"1972\"\u003e✔ Inverter DC-side protection\u003c\/p\u003e\n\u003chr data-start=\"2005\" data-end=\"2008\"\u003e\n\u003ch2 data-start=\"2010\" data-end=\"2030\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2032\" data-end=\"2183\"\u003e\n\u003cli data-start=\"2032\" data-end=\"2062\"\u003e\n\u003cp data-start=\"2034\" data-end=\"2062\"\u003eStandard DIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2093\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2093\"\u003eScrew terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2094\" data-end=\"2138\"\u003e\n\u003cp data-start=\"2096\" data-end=\"2138\"\u003eUse with 10x38 fuses rated for 1000 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2139\" data-end=\"2183\"\u003e\n\u003cp data-start=\"2141\" data-end=\"2183\"\u003eInstallation by qualified personnel only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2185\" data-end=\"2188\"\u003e\n\u003ch2 data-start=\"2190\" data-end=\"2207\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2209\" data-end=\"2308\"\u003eUsed product in good cosmetic condition.\u003cbr data-start=\"2249\" data-end=\"2252\"\u003eTechnical inspection recommended before commissioning.\u003c\/p\u003e\n\u003chr data-start=\"2310\" data-end=\"2313\"\u003e\n\u003ch2 data-start=\"2315\" data-end=\"2338\"\u003e📦 Scope of Supply\u003c\/h2\u003e\n\u003cul data-start=\"2340\" data-end=\"2431\"\u003e\n\u003cli data-start=\"2340\" data-end=\"2431\"\u003e\n\u003cp data-start=\"2342\" data-end=\"2431\"\u003e1x Ferraz Shawmut US101HEL fuse holder\u003cbr data-start=\"2380\" data-end=\"2383\"\u003e(Fuse not included unless otherwise specified)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2433\" data-end=\"2436\"\u003e\n\u003ch2 data-start=\"2438\" data-end=\"2464\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2466\" data-end=\"2721\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eProfessional 1000 V DC modular fuse holder for 10x38 mm fuse links, ideal for photovoltaic string protection and high-voltage DC applications. The Ferraz Shawmut US101HEL provides IEC and UL certified safety and reliability for demanding DC installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Ferraz Shawmut","offers":[{"title":"Default Title","offer_id":53459782336845,"sku":null,"price":8.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5063.jpg?v=1772532001"},{"product_id":"siba-5106304-dc-1p-fuse-holder-10x38-mm-1000v-dc-30-32a-iec-60947-din-rail","title":"SIBA 5106304.DC – 1P Fuse Holder 10x38 mm | 1000V DC | 30\/32A | IEC 60947 | DIN Rail","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"3f2154e0-c9d1-4a90-8dfb-bef173fc5de8\" data-testid=\"conversation-turn-44\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"3f2154e0-c9d1-4a90-8dfb-bef173fc5de8\" dir=\"auto\" data-message-model-slug=\"gpt-5-2\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-start=\"163\" data-end=\"359\"\u003eThe \u003cstrong data-start=\"167\" data-end=\"186\"\u003eSIBA 5106304.DC\u003c\/strong\u003e is a \u003cstrong data-start=\"192\" data-end=\"227\"\u003esingle-pole modular fuse holder\u003c\/strong\u003e designed for \u003cstrong data-start=\"241\" data-end=\"276\"\u003eDC applications up to 1000 V DC\u003c\/strong\u003e, suitable for photovoltaic systems and high-voltage DC distribution installations.\u003c\/p\u003e\n\u003cp data-start=\"361\" data-end=\"561\"\u003eEngineered to accommodate \u003cstrong data-start=\"387\" data-end=\"422\"\u003e10x38 mm cylindrical fuse links\u003c\/strong\u003e, this device provides safe fuse integration and reliable circuit isolation in accordance with \u003cstrong data-start=\"517\" data-end=\"530\"\u003eIEC 60947\u003c\/strong\u003e and \u003cstrong data-start=\"535\" data-end=\"550\"\u003eIEC 60269-2\u003c\/strong\u003e standards.\u003c\/p\u003e\n\u003cp data-start=\"563\" data-end=\"590\"\u003eThe unit is clearly marked:\u003c\/p\u003e\n\u003cp data-start=\"592\" data-end=\"654\"\u003e⚠ \u003cstrong data-start=\"594\" data-end=\"620\"\u003eDO NOT OPEN UNDER LOAD\u003c\/strong\u003e\u003cbr data-start=\"620\" data-end=\"623\"\u003e⚠ \u003cstrong data-start=\"625\" data-end=\"654\"\u003eSUPPLY SIDE FROM TOP ONLY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"656\" data-end=\"798\"\u003eThis confirms that the device is intended for fuse-based protection and manual isolation, but must not be operated while energized under load.\u003c\/p\u003e\n\u003chr data-start=\"800\" data-end=\"803\"\u003e\n\u003ch2 data-start=\"805\" data-end=\"837\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"839\" data-end=\"996\"\u003e\u003cstrong data-start=\"839\" data-end=\"849\"\u003eBrand:\u003c\/strong\u003e SIBA\u003cbr data-start=\"854\" data-end=\"857\"\u003e\u003cstrong data-start=\"857\" data-end=\"874\"\u003eModel \/ Code:\u003c\/strong\u003e 5106304.DC\u003cbr data-start=\"885\" data-end=\"888\"\u003e\u003cstrong data-start=\"888\" data-end=\"897\"\u003eType:\u003c\/strong\u003e Modular fuse holder\u003cbr data-start=\"917\" data-end=\"920\"\u003e\u003cstrong data-start=\"920\" data-end=\"940\"\u003eNumber of poles:\u003c\/strong\u003e 1P\u003cbr data-start=\"943\" data-end=\"946\"\u003e\u003cstrong data-start=\"946\" data-end=\"960\"\u003eFuse size:\u003c\/strong\u003e 10x38 mm\u003cbr data-start=\"969\" data-end=\"972\"\u003e\u003cstrong data-start=\"972\" data-end=\"985\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003ch3 data-start=\"998\" data-end=\"1025\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1027\" data-end=\"1300\"\u003e\n\u003cli data-start=\"1027\" data-end=\"1061\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1061\"\u003eMaximum voltage: \u003cstrong data-start=\"1046\" data-end=\"1059\"\u003e1000 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1062\" data-end=\"1092\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1092\"\u003eRated current: \u003cstrong data-start=\"1079\" data-end=\"1090\"\u003e30\/32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1093\" data-end=\"1128\"\u003e\n\u003cp data-start=\"1095\" data-end=\"1128\"\u003eRated power acceptance: \u003cstrong data-start=\"1119\" data-end=\"1126\"\u003e4 W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1129\" data-end=\"1168\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1168\"\u003eIEC utilization category: \u003cstrong data-start=\"1157\" data-end=\"1166\"\u003eDC-20\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1169\" data-end=\"1217\"\u003e\n\u003cp data-start=\"1171\" data-end=\"1217\"\u003eAC rating (per marking): \u003cstrong data-start=\"1196\" data-end=\"1215\"\u003e600 V AC – 30 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1218\" data-end=\"1258\"\u003e\n\u003cp data-start=\"1220\" data-end=\"1258\"\u003eMaximum connecting cable: \u003cstrong data-start=\"1246\" data-end=\"1256\"\u003e25 mm²\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1259\" data-end=\"1300\"\u003e\n\u003cp data-start=\"1261\" data-end=\"1300\"\u003eMaximum tightening torque: \u003cstrong data-start=\"1288\" data-end=\"1298\"\u003e1.5 Nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1302\" data-end=\"1332\"\u003e📜 Standards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1334\" data-end=\"1456\"\u003e\n\u003cli data-start=\"1334\" data-end=\"1347\"\u003e\n\u003cp data-start=\"1336\" data-end=\"1347\"\u003eIEC 60947\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1348\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1350\" data-end=\"1363\"\u003eIEC 60269-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1377\"\u003e\n\u003cp data-start=\"1366\" data-end=\"1377\"\u003eNFC 61201\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1391\"\u003e\n\u003cp data-start=\"1380\" data-end=\"1391\"\u003eUNE 21103\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1392\" data-end=\"1406\"\u003e\n\u003cp data-start=\"1394\" data-end=\"1406\"\u003eCE Marking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1407\" data-end=\"1456\"\u003e\n\u003cp data-start=\"1409\" data-end=\"1456\"\u003eUL Recognized (600 V AC 30 A marking visible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1458\" data-end=\"1461\"\u003e\n\u003ch2 data-start=\"1463\" data-end=\"1479\"\u003e🔎 Function\u003c\/h2\u003e\n\u003cp data-start=\"1481\" data-end=\"1504\"\u003eThe fuse holder allows:\u003c\/p\u003e\n\u003cp data-start=\"1506\" data-end=\"1693\"\u003e✔ Safe installation of 10x38 mm fuse links\u003cbr data-start=\"1548\" data-end=\"1551\"\u003e✔ Overcurrent protection in DC systems\u003cbr data-start=\"1589\" data-end=\"1592\"\u003e✔ Manual circuit isolation via fuse carrier\u003cbr data-start=\"1635\" data-end=\"1638\"\u003e✔ Application in photovoltaic systems up to 1000 V DC\u003c\/p\u003e\n\u003cp data-start=\"1695\" data-end=\"1756\"\u003e⚠ Not a circuit breaker.\u003cbr data-start=\"1719\" data-end=\"1722\"\u003e⚠ Must not be opened under load.\u003c\/p\u003e\n\u003chr data-start=\"1758\" data-end=\"1761\"\u003e\n\u003ch2 data-start=\"1763\" data-end=\"1783\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1785\" data-end=\"1939\"\u003e✔ Photovoltaic string protection\u003cbr data-start=\"1817\" data-end=\"1820\"\u003e✔ DC combiner boxes\u003cbr data-start=\"1839\" data-end=\"1842\"\u003e✔ Industrial DC distribution systems\u003cbr data-start=\"1878\" data-end=\"1881\"\u003e✔ Energy storage systems\u003cbr data-start=\"1905\" data-end=\"1908\"\u003e✔ Inverter DC-side protection\u003c\/p\u003e\n\u003chr data-start=\"1941\" data-end=\"1944\"\u003e\n\u003ch2 data-start=\"1946\" data-end=\"1966\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1968\" data-end=\"2128\"\u003e\n\u003cli data-start=\"1968\" data-end=\"1997\"\u003e\n\u003cp data-start=\"1970\" data-end=\"1997\"\u003eDIN rail mounting (35 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1998\" data-end=\"2037\"\u003e\n\u003cp data-start=\"2000\" data-end=\"2037\"\u003eTop-side supply connection required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2038\" data-end=\"2088\"\u003e\n\u003cp data-start=\"2040\" data-end=\"2088\"\u003eUse only with suitable 10x38 mm DC-rated fuses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2089\" data-end=\"2128\"\u003e\n\u003cp data-start=\"2091\" data-end=\"2128\"\u003eInstallation by qualified personnel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2130\" data-end=\"2133\"\u003e\n\u003ch2 data-start=\"2135\" data-end=\"2152\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2154\" data-end=\"2278\"\u003eUsed product in good cosmetic condition, as shown in the photos.\u003cbr data-start=\"2218\" data-end=\"2221\"\u003eTechnical inspection recommended prior to installation.\u003c\/p\u003e\n\u003chr data-start=\"2280\" data-end=\"2283\"\u003e\n\u003ch2 data-start=\"2285\" data-end=\"2308\"\u003e📦 Scope of Supply\u003c\/h2\u003e\n\u003cul data-start=\"2310\" data-end=\"2393\"\u003e\n\u003cli data-start=\"2310\" data-end=\"2393\"\u003e\n\u003cp data-start=\"2312\" data-end=\"2393\"\u003e1x SIBA 5106304.DC fuse holder\u003cbr data-start=\"2342\" data-end=\"2345\"\u003e(Fuse not included unless otherwise specified)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2395\" data-end=\"2398\"\u003e\n\u003ch2 data-start=\"2400\" data-end=\"2426\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2428\" data-end=\"2665\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eProfessional 1000 V DC fuse holder for 10x38 mm fuse links, ideal for photovoltaic and high-voltage DC applications. The SIBA 5106304.DC provides reliable, standards-compliant protection and safe isolation for demanding DC installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"SIBA","offers":[{"title":"Default Title","offer_id":53459784663373,"sku":null,"price":5.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5059.jpg?v=1772532772"},{"product_id":"schneider-electric-lc1d32-3p-32a-ac-3-contactor-690v-ac-coil-a1-a2-tesys-d-series","title":"Schneider Electric LC1D32 – 3P 32A AC-3 Contactor | 690V AC | Coil A1\/A2 | TeSys D Series","description":"\u003cp data-start=\"184\" data-end=\"432\"\u003eThe \u003cstrong data-start=\"188\" data-end=\"217\"\u003eSchneider Electric LC1D32\u003c\/strong\u003e is a three-phase electromechanical power contactor from the \u003cstrong data-start=\"278\" data-end=\"296\"\u003eTeSys D series\u003c\/strong\u003e (formerly Telemecanique), designed for switching and controlling electric motors and industrial loads in \u003cstrong data-start=\"402\" data-end=\"431\"\u003eAC-3 utilization category\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"434\" data-end=\"644\"\u003eCompact, robust, and highly reliable, this contactor is suitable for industrial automation panels and power distribution systems, offering high switching performance and long mechanical and electrical lifespan.\u003c\/p\u003e\n\u003chr data-start=\"646\" data-end=\"649\"\u003e\n\u003ch2 data-start=\"651\" data-end=\"683\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"685\" data-end=\"826\"\u003e\u003cstrong data-start=\"685\" data-end=\"695\"\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003cbr data-start=\"714\" data-end=\"717\"\u003e\u003cstrong data-start=\"717\" data-end=\"728\"\u003eSeries:\u003c\/strong\u003e TeSys D\u003cbr data-start=\"736\" data-end=\"739\"\u003e\u003cstrong data-start=\"739\" data-end=\"749\"\u003eModel:\u003c\/strong\u003e LC1D32\u003cbr data-start=\"756\" data-end=\"759\"\u003e\u003cstrong data-start=\"759\" data-end=\"768\"\u003eType:\u003c\/strong\u003e Power contactor\u003cbr data-start=\"784\" data-end=\"787\"\u003e\u003cstrong data-start=\"787\" data-end=\"807\"\u003eNumber of poles:\u003c\/strong\u003e 3P (three-phase)\u003c\/p\u003e\n\u003ch3 data-start=\"828\" data-end=\"855\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"857\" data-end=\"1085\"\u003e\n\u003cli data-start=\"857\" data-end=\"903\"\u003e\n\u003cp data-start=\"859\" data-end=\"903\"\u003eRated operational current (AC-3): \u003cstrong data-start=\"893\" data-end=\"901\"\u003e32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"958\"\u003e\n\u003cp data-start=\"906\" data-end=\"958\"\u003eRated operational voltage (Ue): \u003cstrong data-start=\"938\" data-end=\"956\"\u003eup to 690 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"959\" data-end=\"1003\"\u003e\n\u003cp data-start=\"961\" data-end=\"1003\"\u003eRated insulation voltage (Ui): \u003cstrong data-start=\"992\" data-end=\"1001\"\u003e690 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1004\" data-end=\"1050\"\u003e\n\u003cp data-start=\"1006\" data-end=\"1050\"\u003eImpulse withstand voltage (Uimp): \u003cstrong data-start=\"1040\" data-end=\"1048\"\u003e6 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1051\" data-end=\"1085\"\u003e\n\u003cp data-start=\"1053\" data-end=\"1085\"\u003eUtilization category: \u003cstrong data-start=\"1075\" data-end=\"1083\"\u003eAC-3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1087\" data-end=\"1124\"\u003e⚡ Indicative Motor Power (AC-3)\u003c\/h3\u003e\n\u003cul data-start=\"1126\" data-end=\"1194\"\u003e\n\u003cli data-start=\"1126\" data-end=\"1148\"\u003e\n\u003cp data-start=\"1128\" data-end=\"1148\"\u003e\u003cstrong data-start=\"1128\" data-end=\"1146\"\u003e7.5 kW @ 230 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1170\"\u003e\n\u003cp data-start=\"1151\" data-end=\"1170\"\u003e\u003cstrong data-start=\"1151\" data-end=\"1168\"\u003e15 kW @ 400 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1171\" data-end=\"1194\"\u003e\n\u003cp data-start=\"1173\" data-end=\"1194\"\u003e\u003cstrong data-start=\"1173\" data-end=\"1192\"\u003e18.5 kW @ 500 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1196\" data-end=\"1220\"\u003e🔄 Control Circuit\u003c\/h3\u003e\n\u003cul data-start=\"1222\" data-end=\"1313\"\u003e\n\u003cli data-start=\"1222\" data-end=\"1253\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1253\"\u003eCoil terminals: \u003cstrong data-start=\"1240\" data-end=\"1251\"\u003eA1 – A2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1313\"\u003e\n\u003cp data-start=\"1256\" data-end=\"1313\"\u003e⚠ Coil voltage must be verified on the device nameplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1315\" data-end=\"1355\"\u003e🔧 Auxiliary Contacts (Integrated)\u003c\/h3\u003e\n\u003cul data-start=\"1357\" data-end=\"1398\"\u003e\n\u003cli data-start=\"1357\" data-end=\"1377\"\u003e\n\u003cp data-start=\"1359\" data-end=\"1377\"\u003e\u003cstrong data-start=\"1359\" data-end=\"1375\"\u003e1 NO (13-14)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1398\"\u003e\n\u003cp data-start=\"1380\" data-end=\"1398\"\u003e\u003cstrong data-start=\"1380\" data-end=\"1396\"\u003e1 NC (21-22)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1400\" data-end=\"1418\"\u003e📜 Standards\u003c\/h3\u003e\n\u003cul data-start=\"1420\" data-end=\"1442\"\u003e\n\u003cli data-start=\"1420\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1422\" data-end=\"1442\"\u003eIEC \/ EN 60947-4-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1444\" data-end=\"1461\"\u003e🛠 Mounting\u003c\/h3\u003e\n\u003cul data-start=\"1463\" data-end=\"1515\"\u003e\n\u003cli data-start=\"1463\" data-end=\"1484\"\u003e\n\u003cp data-start=\"1465\" data-end=\"1484\"\u003eDIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1485\" data-end=\"1515\"\u003e\n\u003cp data-start=\"1487\" data-end=\"1515\"\u003ePanel mounting with screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1517\" data-end=\"1520\"\u003e\n\u003ch2 data-start=\"1522\" data-end=\"1538\"\u003e🔎 Function\u003c\/h2\u003e\n\u003cp data-start=\"1540\" data-end=\"1570\"\u003eThe contactor is designed for:\u003c\/p\u003e\n\u003cp data-start=\"1572\" data-end=\"1734\"\u003e✔ Starting and stopping three-phase motors\u003cbr data-start=\"1614\" data-end=\"1617\"\u003e✔ Switching inductive loads\u003cbr data-start=\"1644\" data-end=\"1647\"\u003e✔ Integration into industrial automation systems\u003cbr data-start=\"1695\" data-end=\"1698\"\u003e✔ Use in power distribution panels\u003c\/p\u003e\n\u003cp data-start=\"1736\" data-end=\"1824\"\u003eIntegrated auxiliary contacts allow signaling, control logic, or interlocking functions.\u003c\/p\u003e\n\u003chr data-start=\"1826\" data-end=\"1829\"\u003e\n\u003ch2 data-start=\"1831\" data-end=\"1851\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1853\" data-end=\"1999\"\u003e✔ Industrial automation panels\u003cbr data-start=\"1883\" data-end=\"1886\"\u003e✔ Three-phase motor control\u003cbr data-start=\"1913\" data-end=\"1916\"\u003e✔ Compressors\u003cbr data-start=\"1929\" data-end=\"1932\"\u003e✔ Pumps\u003cbr data-start=\"1939\" data-end=\"1942\"\u003e✔ Industrial fans\u003cbr data-start=\"1959\" data-end=\"1962\"\u003e✔ HVAC systems\u003cbr data-start=\"1976\" data-end=\"1979\"\u003e✔ Production lines\u003c\/p\u003e\n\u003chr data-start=\"2001\" data-end=\"2004\"\u003e\n\u003ch2 data-start=\"2006\" data-end=\"2026\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2028\" data-end=\"2189\"\u003e\n\u003cli data-start=\"2028\" data-end=\"2061\"\u003e\n\u003cp data-start=\"2030\" data-end=\"2061\"\u003eMounting on DIN rail or panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2062\" data-end=\"2108\"\u003e\n\u003cp data-start=\"2064\" data-end=\"2108\"\u003ePower connections: \u003cstrong data-start=\"2083\" data-end=\"2106\"\u003eL1-L2-L3 \/ T1-T2-T3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2109\" data-end=\"2139\"\u003e\n\u003cp data-start=\"2111\" data-end=\"2139\"\u003eCoil connection: \u003cstrong data-start=\"2128\" data-end=\"2137\"\u003eA1-A2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2140\" data-end=\"2189\"\u003e\n\u003cp data-start=\"2142\" data-end=\"2189\"\u003eCompatible with TeSys thermal overload relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2191\" data-end=\"2194\"\u003e\n\u003ch2 data-start=\"2196\" data-end=\"2213\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2215\" data-end=\"2326\"\u003eUsed product in good cosmetic condition.\u003cbr data-start=\"2255\" data-end=\"2258\"\u003eVerification of coil voltage is recommended prior to installation.\u003c\/p\u003e\n\u003chr data-start=\"2328\" data-end=\"2331\"\u003e\n\u003ch2 data-start=\"2333\" data-end=\"2356\"\u003e📦 Scope of Supply\u003c\/h2\u003e\n\u003cul data-start=\"2358\" data-end=\"2400\"\u003e\n\u003cli data-start=\"2358\" data-end=\"2400\"\u003e\n\u003cp data-start=\"2360\" data-end=\"2400\"\u003e1x Schneider Electric LC1D32 contactor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2402\" data-end=\"2405\"\u003e\n\u003ch2 data-start=\"2407\" data-end=\"2433\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2435\" data-end=\"2673\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eProfessional 32A AC-3 three-phase contactor from the Schneider Electric TeSys D range. The LC1D32 is ideal for controlling motors up to 15 kW at 400V, offering reliable performance for industrial automation and power control applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53459797311821,"sku":null,"price":45.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5056.jpg?v=1772533386"},{"product_id":"schneider-electric-lc1d09-3p-9a-ac-3-contactor-690v-ac-tesys-d-series-with-auxiliary-contacts-1no-1nc","title":"Schneider Electric LC1D09 – 3P 9A AC-3 Contactor | 690V AC | TeSys D Series | With Auxiliary Contacts 1NO + 1NC","description":"\u003cp data-start=\"190\" data-end=\"384\"\u003eThe \u003cstrong data-start=\"194\" data-end=\"223\"\u003eSchneider Electric LC1D09\u003c\/strong\u003e is a \u003cstrong data-start=\"229\" data-end=\"278\"\u003ethree-phase electromechanical power contactor\u003c\/strong\u003e from the \u003cstrong data-start=\"288\" data-end=\"306\"\u003eTeSys D series\u003c\/strong\u003e, designed for switching and controlling electric motors and industrial loads.\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"658\"\u003eWidely used in \u003cstrong data-start=\"401\" data-end=\"433\"\u003eindustrial automation panels\u003c\/strong\u003e, this contactor offers high reliability, compact design, and long electrical and mechanical lifespan. It is specifically suited for \u003cstrong data-start=\"566\" data-end=\"595\"\u003eAC-3 utilization category\u003c\/strong\u003e, making it ideal for motor starting and stopping applications.\u003c\/p\u003e\n\u003cp data-start=\"660\" data-end=\"821\"\u003eThe device includes \u003cstrong data-start=\"680\" data-end=\"727\"\u003eintegrated auxiliary contacts (1 NO + 1 NC)\u003c\/strong\u003e, allowing signaling, interlocking, and control feedback functions within automation circuits.\u003c\/p\u003e\n\u003chr data-start=\"823\" data-end=\"826\"\u003e\n\u003ch2 data-start=\"828\" data-end=\"860\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"862\" data-end=\"1001\"\u003e\u003cstrong data-start=\"862\" data-end=\"872\"\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003cbr data-start=\"891\" data-end=\"894\"\u003e\u003cstrong data-start=\"894\" data-end=\"905\"\u003eSeries:\u003c\/strong\u003e TeSys D\u003cbr data-start=\"913\" data-end=\"916\"\u003e\u003cstrong data-start=\"916\" data-end=\"926\"\u003eModel:\u003c\/strong\u003e LC1D09\u003cbr data-start=\"933\" data-end=\"936\"\u003e\u003cstrong data-start=\"936\" data-end=\"945\"\u003eType:\u003c\/strong\u003e Power contactor\u003cbr data-start=\"961\" data-end=\"964\"\u003e\u003cstrong data-start=\"964\" data-end=\"984\"\u003eNumber of poles:\u003c\/strong\u003e 3P (three-phase)\u003c\/p\u003e\n\u003ch3 data-start=\"1003\" data-end=\"1030\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1032\" data-end=\"1202\"\u003e\n\u003cli data-start=\"1032\" data-end=\"1077\"\u003e\n\u003cp data-start=\"1034\" data-end=\"1077\"\u003eRated operational current (AC-3): \u003cstrong data-start=\"1068\" data-end=\"1075\"\u003e9 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1078\" data-end=\"1122\"\u003e\n\u003cp data-start=\"1080\" data-end=\"1122\"\u003eRated insulation voltage (Ui): \u003cstrong data-start=\"1111\" data-end=\"1120\"\u003e690 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1123\" data-end=\"1169\"\u003e\n\u003cp data-start=\"1125\" data-end=\"1169\"\u003eImpulse withstand voltage (Uimp): \u003cstrong data-start=\"1159\" data-end=\"1167\"\u003e6 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1170\" data-end=\"1202\"\u003e\n\u003cp data-start=\"1172\" data-end=\"1202\"\u003eUtilization category: \u003cstrong data-start=\"1194\" data-end=\"1202\"\u003eAC-3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1204\" data-end=\"1236\"\u003e⚡ Typical Motor Power (AC-3)\u003c\/h3\u003e\n\u003cul data-start=\"1238\" data-end=\"1325\"\u003e\n\u003cli data-start=\"1238\" data-end=\"1260\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1260\"\u003e\u003cstrong data-start=\"1240\" data-end=\"1258\"\u003e2.2 kW @ 230 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1261\" data-end=\"1281\"\u003e\n\u003cp data-start=\"1263\" data-end=\"1281\"\u003e\u003cstrong data-start=\"1263\" data-end=\"1279\"\u003e4 kW @ 400 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1282\" data-end=\"1304\"\u003e\n\u003cp data-start=\"1284\" data-end=\"1304\"\u003e\u003cstrong data-start=\"1284\" data-end=\"1302\"\u003e5.5 kW @ 500 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1305\" data-end=\"1325\"\u003e\n\u003cp data-start=\"1307\" data-end=\"1325\"\u003e\u003cstrong data-start=\"1307\" data-end=\"1325\"\u003e5.5 kW @ 690 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1327\" data-end=\"1330\"\u003e\n\u003ch2 data-start=\"1332\" data-end=\"1351\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003ch3 data-start=\"1353\" data-end=\"1374\"\u003ePower Terminals\u003c\/h3\u003e\n\u003cp data-start=\"1376\" data-end=\"1388\"\u003e\u003cstrong data-start=\"1376\" data-end=\"1386\"\u003eInput:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1389\" data-end=\"1412\"\u003e\n\u003cli data-start=\"1389\" data-end=\"1396\"\u003e\n\u003cp data-start=\"1391\" data-end=\"1396\"\u003e1L1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1397\" data-end=\"1404\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1404\"\u003e3L2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1405\" data-end=\"1412\"\u003e\n\u003cp data-start=\"1407\" data-end=\"1412\"\u003e5L3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1414\" data-end=\"1427\"\u003e\u003cstrong data-start=\"1414\" data-end=\"1425\"\u003eOutput:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1428\" data-end=\"1451\"\u003e\n\u003cli data-start=\"1428\" data-end=\"1435\"\u003e\n\u003cp data-start=\"1430\" data-end=\"1435\"\u003e2T1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1436\" data-end=\"1443\"\u003e\n\u003cp data-start=\"1438\" data-end=\"1443\"\u003e4T2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1444\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1446\" data-end=\"1451\"\u003e6T3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1453\" data-end=\"1477\"\u003eAuxiliary Contacts\u003c\/h3\u003e\n\u003cul data-start=\"1479\" data-end=\"1546\"\u003e\n\u003cli data-start=\"1479\" data-end=\"1512\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1512\"\u003e\u003cstrong data-start=\"1481\" data-end=\"1491\"\u003e13–14:\u003c\/strong\u003e NO (Normally Open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1546\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1546\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1525\"\u003e21–22:\u003c\/strong\u003e NC (Normally Closed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1548\" data-end=\"1566\"\u003eControl Coil\u003c\/h3\u003e\n\u003cul data-start=\"1568\" data-end=\"1657\"\u003e\n\u003cli data-start=\"1568\" data-end=\"1657\"\u003e\n\u003cp data-start=\"1570\" data-end=\"1657\"\u003e\u003cstrong data-start=\"1570\" data-end=\"1581\"\u003eA1 – A2\u003c\/strong\u003e\u003cbr data-start=\"1581\" data-end=\"1584\"\u003e⚠ Coil voltage varies depending on the specific version of the contactor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1659\" data-end=\"1662\"\u003e\n\u003ch2 data-start=\"1664\" data-end=\"1698\"\u003e🛡 Standards \u0026amp; Certifications\u003c\/h2\u003e\n\u003cul data-start=\"1700\" data-end=\"1789\"\u003e\n\u003cli data-start=\"1700\" data-end=\"1722\"\u003e\n\u003cp data-start=\"1702\" data-end=\"1722\"\u003eIEC \/ EN 60947-4-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1723\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1725\" data-end=\"1745\"\u003eIEC \/ EN 60947-5-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1746\" data-end=\"1789\"\u003e\n\u003cp data-start=\"1748\" data-end=\"1789\"\u003eInternational industrial certifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1791\" data-end=\"1794\"\u003e\n\u003ch2 data-start=\"1796\" data-end=\"1816\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1818\" data-end=\"1872\"\u003eThe contactor is designed for industrial uses such as:\u003c\/p\u003e\n\u003cp data-start=\"1874\" data-end=\"2050\"\u003e✔ Three-phase motor starting\u003cbr data-start=\"1902\" data-end=\"1905\"\u003e✔ Industrial automation panels\u003cbr data-start=\"1935\" data-end=\"1938\"\u003e✔ HVAC systems\u003cbr data-start=\"1952\" data-end=\"1955\"\u003e✔ Pumps and ventilation systems\u003cbr data-start=\"1986\" data-end=\"1989\"\u003e✔ Compressors\u003cbr data-start=\"2002\" data-end=\"2005\"\u003e✔ Production lines\u003cbr data-start=\"2023\" data-end=\"2026\"\u003e✔ Industrial machinery\u003c\/p\u003e\n\u003chr data-start=\"2052\" data-end=\"2055\"\u003e\n\u003ch2 data-start=\"2057\" data-end=\"2077\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2079\" data-end=\"2274\"\u003e\n\u003cli data-start=\"2079\" data-end=\"2118\"\u003e\n\u003cp data-start=\"2081\" data-end=\"2118\"\u003eDIN rail mounting or panel mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2119\" data-end=\"2191\"\u003e\n\u003cp data-start=\"2121\" data-end=\"2191\"\u003eCompatible with \u003cstrong data-start=\"2137\" data-end=\"2189\"\u003eSchneider Electric TeSys thermal overload relays\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2192\" data-end=\"2222\"\u003e\n\u003cp data-start=\"2194\" data-end=\"2222\"\u003eScrew terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2223\" data-end=\"2274\"\u003e\n\u003cp data-start=\"2225\" data-end=\"2274\"\u003eInstallation recommended by qualified personnel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53472481968461,"sku":null,"price":40.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5052.jpg?v=1772623056"},{"product_id":"legrand-05808-1-pole-fuse-holder-10-38-mm-32a-400-500v-din-rail","title":"Legrand 05808 – 1-Pole Fuse Holder | 10×38 mm | 32A | 400\/500V | DIN Rail","description":"\u003cp data-start=\"152\" data-end=\"362\"\u003eThe \u003cstrong data-start=\"156\" data-end=\"173\"\u003eLegrand 05808\u003c\/strong\u003e is a \u003cstrong data-start=\"179\" data-end=\"214\"\u003esingle-pole modular fuse holder\u003c\/strong\u003e designed for \u003cstrong data-start=\"228\" data-end=\"263\"\u003e10×38 mm cylindrical fuse links\u003c\/strong\u003e, used for protecting electrical circuits in industrial, commercial, and residential installations.\u003c\/p\u003e\n\u003cp data-start=\"364\" data-end=\"679\"\u003eThanks to its \u003cstrong data-start=\"378\" data-end=\"407\"\u003ecompact and robust design\u003c\/strong\u003e, this fuse holder provides reliable protection against overcurrents and short circuits, making it suitable for installation in electrical panels on \u003cstrong data-start=\"556\" data-end=\"578\"\u003estandard DIN rails\u003c\/strong\u003e. The device features a \u003cstrong data-start=\"602\" data-end=\"636\"\u003etransparent front safety cover\u003c\/strong\u003e, allowing quick and safe fuse replacement.\u003c\/p\u003e\n\u003cp data-start=\"681\" data-end=\"883\"\u003eManufactured according to \u003cstrong data-start=\"707\" data-end=\"738\"\u003einternational IEC standards\u003c\/strong\u003e, the unit offers high interrupting capacity when used with appropriate fuse links, making it ideal for distribution and automation applications.\u003c\/p\u003e\n\u003chr data-start=\"885\" data-end=\"888\"\u003e\n\u003ch2 data-start=\"890\" data-end=\"922\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"924\" data-end=\"1127\"\u003e\u003cstrong data-start=\"924\" data-end=\"934\"\u003eBrand:\u003c\/strong\u003e Legrand\u003cbr data-start=\"942\" data-end=\"945\"\u003e\u003cstrong data-start=\"945\" data-end=\"962\"\u003eProduct Code:\u003c\/strong\u003e 05808\u003cbr data-start=\"968\" data-end=\"971\"\u003e\u003cstrong data-start=\"971\" data-end=\"980\"\u003eType:\u003c\/strong\u003e Modular fuse holder\u003cbr data-start=\"1000\" data-end=\"1003\"\u003e\u003cstrong data-start=\"1003\" data-end=\"1023\"\u003eNumber of poles:\u003c\/strong\u003e 1P (single-pole)\u003cbr data-start=\"1040\" data-end=\"1043\"\u003e\u003cstrong data-start=\"1043\" data-end=\"1068\"\u003eCompatible fuse type:\u003c\/strong\u003e Cylindrical \u003cstrong data-start=\"1081\" data-end=\"1095\"\u003e10 × 38 mm\u003c\/strong\u003e\u003cbr data-start=\"1095\" data-end=\"1098\"\u003e\u003cstrong data-start=\"1098\" data-end=\"1116\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1117\" data-end=\"1125\"\u003e32 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1129\" data-end=\"1156\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1158\" data-end=\"1296\"\u003e\n\u003cli data-start=\"1158\" data-end=\"1232\"\u003e\n\u003cp data-start=\"1160\" data-end=\"1176\"\u003eRated voltage:\u003c\/p\u003e\n\u003cul data-start=\"1179\" data-end=\"1232\"\u003e\n\u003cli data-start=\"1179\" data-end=\"1204\"\u003e\n\u003cp data-start=\"1181\" data-end=\"1204\"\u003e\u003cstrong data-start=\"1181\" data-end=\"1202\"\u003e400 V (IEC 269-3)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1207\" data-end=\"1232\"\u003e\n\u003cp data-start=\"1209\" data-end=\"1232\"\u003e\u003cstrong data-start=\"1209\" data-end=\"1230\"\u003e500 V (IEC 269-2)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1233\" data-end=\"1296\"\u003e\n\u003cp data-start=\"1235\" data-end=\"1296\"\u003eBreaking capacity: \u003cstrong data-start=\"1254\" data-end=\"1270\"\u003eup to 100 kA\u003c\/strong\u003e (with appropriate fuse)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1298\" data-end=\"1316\"\u003e📜 Standards\u003c\/h3\u003e\n\u003cul data-start=\"1318\" data-end=\"1345\"\u003e\n\u003cli data-start=\"1318\" data-end=\"1331\"\u003e\n\u003cp data-start=\"1320\" data-end=\"1331\"\u003eIEC 269-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1332\" data-end=\"1345\"\u003e\n\u003cp data-start=\"1334\" data-end=\"1345\"\u003eIEC 269-3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1347\" data-end=\"1364\"\u003e🛠 Mounting\u003c\/h3\u003e\n\u003cul data-start=\"1366\" data-end=\"1386\"\u003e\n\u003cli data-start=\"1366\" data-end=\"1386\"\u003e\n\u003cp data-start=\"1368\" data-end=\"1386\"\u003e\u003cstrong data-start=\"1368\" data-end=\"1386\"\u003eDIN rail 35 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1388\" data-end=\"1391\"\u003e\n\u003ch2 data-start=\"1393\" data-end=\"1422\"\u003e🛡 Construction Features\u003c\/h2\u003e\n\u003cp data-start=\"1424\" data-end=\"1607\"\u003e✔ Compact modular structure\u003cbr data-start=\"1451\" data-end=\"1454\"\u003e✔ Transparent protective front cover\u003cbr data-start=\"1490\" data-end=\"1493\"\u003e✔ Screw terminal connections\u003cbr data-start=\"1521\" data-end=\"1524\"\u003e✔ High operational reliability and durability\u003cbr data-start=\"1569\" data-end=\"1572\"\u003e✔ Quick and safe fuse replacement\u003c\/p\u003e\n\u003chr data-start=\"1609\" data-end=\"1612\"\u003e\n\u003ch2 data-start=\"1614\" data-end=\"1634\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1636\" data-end=\"1673\"\u003eThis fuse holder is commonly used in:\u003c\/p\u003e\n\u003cp data-start=\"1675\" data-end=\"1851\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1705\" data-end=\"1708\"\u003e✔ Power distribution boards\u003cbr data-start=\"1735\" data-end=\"1738\"\u003e✔ Photovoltaic installations\u003cbr data-start=\"1766\" data-end=\"1769\"\u003e✔ Supply line protection\u003cbr data-start=\"1793\" data-end=\"1796\"\u003e✔ Automation systems\u003cbr data-start=\"1816\" data-end=\"1819\"\u003e✔ Auxiliary circuit protection\u003c\/p\u003e\n\u003chr data-start=\"1853\" data-end=\"1856\"\u003e\n\u003ch2 data-start=\"1858\" data-end=\"1878\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1880\" data-end=\"2063\"\u003e\n\u003cli data-start=\"1880\" data-end=\"1923\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1923\"\u003eMounting on standard \u003cstrong data-start=\"1903\" data-end=\"1921\"\u003e35 mm DIN rail\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1924\" data-end=\"1958\"\u003e\n\u003cp data-start=\"1926\" data-end=\"1958\"\u003eWiring via \u003cstrong data-start=\"1937\" data-end=\"1956\"\u003escrew terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1959\" data-end=\"2011\"\u003e\n\u003cp data-start=\"1961\" data-end=\"2011\"\u003eFuse replacement through \u003cstrong data-start=\"1986\" data-end=\"2009\"\u003efront opening cover\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2012\" data-end=\"2063\"\u003e\n\u003cp data-start=\"2014\" data-end=\"2063\"\u003eInstallation recommended by qualified personnel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2065\" data-end=\"2068\"\u003e\n\u003ch2 data-start=\"2070\" data-end=\"2096\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2098\" data-end=\"2403\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"2102\" data-end=\"2119\"\u003eLegrand 05808\u003c\/strong\u003e modular fuse holder offers reliable protection and easy maintenance for circuits using \u003cstrong data-start=\"2207\" data-end=\"2230\"\u003e10×38 mm fuse links\u003c\/strong\u003e. Its compact DIN-rail design and high interrupting capability make it a dependable solution for electrical distribution, automation systems, and photovoltaic installations.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":53473821753677,"sku":null,"price":8.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5046.jpg?v=1772623874"},{"product_id":"siemens-3nw7033-3p-fuse-holder-for-10-38-mm-fuses-32a-up-to-690v-ac-din-rail-mount","title":"Siemens 3NW7033 – 3P Fuse Holder for 10×38 mm Fuses | 32A | up to 690V AC | DIN Rail Mount","description":"\u003cp data-start=\"169\" data-end=\"438\"\u003eThe \u003cstrong data-start=\"173\" data-end=\"192\"\u003eSiemens 3NW7033\u003c\/strong\u003e is a \u003cstrong data-start=\"198\" data-end=\"243\"\u003ethree-phase modular fuse holder (3 poles)\u003c\/strong\u003e designed to accommodate \u003cstrong data-start=\"268\" data-end=\"303\"\u003e10×38 mm cylindrical fuse links\u003c\/strong\u003e, commonly used for protecting electrical lines and equipment in industrial installations, distribution boards, and automation systems.\u003c\/p\u003e\n\u003cp data-start=\"440\" data-end=\"620\"\u003eThis device allows the installation of \u003cstrong data-start=\"479\" data-end=\"511\"\u003ethree independent fuse links\u003c\/strong\u003e, providing compact and reliable protection for three-phase circuits against overcurrents and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"622\" data-end=\"795\"\u003eThanks to Siemens’ modular construction and compatibility with \u003cstrong data-start=\"685\" data-end=\"715\"\u003estandard DIN rail mounting\u003c\/strong\u003e, the fuse holder ensures fast and secure installation inside electrical panels.\u003c\/p\u003e\n\u003chr data-start=\"797\" data-end=\"800\"\u003e\n\u003ch2 data-start=\"802\" data-end=\"834\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"836\" data-end=\"1147\"\u003e\u003cstrong data-start=\"836\" data-end=\"846\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"854\" data-end=\"857\"\u003e\u003cstrong data-start=\"857\" data-end=\"867\"\u003eModel:\u003c\/strong\u003e 3NW7033\u003cbr data-start=\"875\" data-end=\"878\"\u003e\u003cstrong data-start=\"878\" data-end=\"887\"\u003eType:\u003c\/strong\u003e Modular fuse holder\u003cbr data-start=\"907\" data-end=\"910\"\u003e\u003cstrong data-start=\"910\" data-end=\"930\"\u003eNumber of poles:\u003c\/strong\u003e 3P (three-phase)\u003cbr data-start=\"947\" data-end=\"950\"\u003e\u003cstrong data-start=\"950\" data-end=\"975\"\u003eCompatible fuse type:\u003c\/strong\u003e Cylindrical \u003cstrong data-start=\"988\" data-end=\"1002\"\u003e10 × 38 mm\u003c\/strong\u003e\u003cbr data-start=\"1002\" data-end=\"1005\"\u003e\u003cstrong data-start=\"1005\" data-end=\"1023\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1024\" data-end=\"1032\"\u003e32 A\u003c\/strong\u003e\u003cbr data-start=\"1032\" data-end=\"1035\"\u003e\u003cstrong data-start=\"1035\" data-end=\"1053\"\u003eRated voltage:\u003c\/strong\u003e up to \u003cstrong data-start=\"1060\" data-end=\"1072\"\u003e690 V AC\u003c\/strong\u003e\u003cbr data-start=\"1072\" data-end=\"1075\"\u003e\u003cstrong data-start=\"1075\" data-end=\"1097\"\u003ePower dissipation:\u003c\/strong\u003e approx. \u003cstrong data-start=\"1106\" data-end=\"1113\"\u003e3 W\u003c\/strong\u003e\u003cbr data-start=\"1113\" data-end=\"1116\"\u003e\u003cstrong data-start=\"1116\" data-end=\"1129\"\u003eStandard:\u003c\/strong\u003e \u003cstrong data-start=\"1130\" data-end=\"1145\"\u003eIEC 60947-3\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1149\" data-end=\"1186\"\u003e🔌 Electrical \u0026amp; Mechanical Data\u003c\/h3\u003e\n\u003cul data-start=\"1188\" data-end=\"1311\"\u003e\n\u003cli data-start=\"1188\" data-end=\"1229\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1229\"\u003eCable cross-section: \u003cstrong data-start=\"1211\" data-end=\"1227\"\u003e0.5 – 10 mm²\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1280\"\u003e\n\u003cp data-start=\"1232\" data-end=\"1280\"\u003eTerminal tightening torque: approx. \u003cstrong data-start=\"1268\" data-end=\"1278\"\u003e1.2 Nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1281\" data-end=\"1311\"\u003e\n\u003cp data-start=\"1283\" data-end=\"1311\"\u003eMounting: \u003cstrong data-start=\"1293\" data-end=\"1311\"\u003eDIN rail 35 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1313\" data-end=\"1316\"\u003e\n\u003ch2 data-start=\"1318\" data-end=\"1337\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003cp data-start=\"1339\" data-end=\"1388\"\u003eThe device includes \u003cstrong data-start=\"1359\" data-end=\"1387\"\u003esix connection terminals\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp data-start=\"1390\" data-end=\"1407\"\u003e\u003cstrong data-start=\"1390\" data-end=\"1405\"\u003eLine input:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1408\" data-end=\"1425\"\u003e\n\u003cli data-start=\"1408\" data-end=\"1413\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1413\"\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1414\" data-end=\"1419\"\u003e\n\u003cp data-start=\"1416\" data-end=\"1419\"\u003e3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1425\"\u003e\n\u003cp data-start=\"1422\" data-end=\"1425\"\u003e5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1427\" data-end=\"1445\"\u003e\u003cstrong data-start=\"1427\" data-end=\"1443\"\u003eLoad output:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1446\" data-end=\"1463\"\u003e\n\u003cli data-start=\"1446\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1448\" data-end=\"1451\"\u003e2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1457\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1457\"\u003e4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1458\" data-end=\"1463\"\u003e\n\u003cp data-start=\"1460\" data-end=\"1463\"\u003e6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1465\" data-end=\"1526\"\u003eTypical configuration for \u003cstrong data-start=\"1491\" data-end=\"1525\"\u003ethree-phase protection systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1528\" data-end=\"1531\"\u003e\n\u003ch2 data-start=\"1533\" data-end=\"1562\"\u003e🛡 Construction Features\u003c\/h2\u003e\n\u003cp data-start=\"1564\" data-end=\"1761\"\u003e✔ Compact Siemens modular design\u003cbr data-start=\"1596\" data-end=\"1599\"\u003e✔ Housing for \u003cstrong data-start=\"1613\" data-end=\"1650\"\u003e3 cylindrical fuse links 10×38 mm\u003c\/strong\u003e\u003cbr data-start=\"1650\" data-end=\"1653\"\u003e✔ Robust screw terminals\u003cbr data-start=\"1677\" data-end=\"1680\"\u003e✔ High reliability for industrial applications\u003cbr data-start=\"1726\" data-end=\"1729\"\u003e✔ Simple DIN rail installation\u003c\/p\u003e\n\u003cp data-start=\"1763\" data-end=\"1837\"\u003e⚠ Safety marking present on the device:\u003cbr data-start=\"1802\" data-end=\"1805\"\u003e\u003cstrong data-start=\"1805\" data-end=\"1837\"\u003e“Do not operate under load.”\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1839\" data-end=\"1842\"\u003e\n\u003ch2 data-start=\"1844\" data-end=\"1864\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1866\" data-end=\"1906\"\u003eThe Siemens fuse holder is suitable for:\u003c\/p\u003e\n\u003cp data-start=\"1908\" data-end=\"2117\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1938\" data-end=\"1941\"\u003e✔ Three-phase line protection\u003cbr data-start=\"1970\" data-end=\"1973\"\u003e✔ Industrial automation systems\u003cbr data-start=\"2004\" data-end=\"2007\"\u003e✔ Photovoltaic installations\u003cbr data-start=\"2035\" data-end=\"2038\"\u003e✔ Power distribution boards\u003cbr data-start=\"2065\" data-end=\"2068\"\u003e✔ Protection of motors and electrical equipment\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53473921794381,"sku":null,"price":8.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5043.jpg?v=1772624198"},{"product_id":"abb-e93-32-3p-modular-fuse-holder-for-10-38-mm-fuses-32a-400v-ac-din-rail","title":"ABB E93\/32 – 3P Modular Fuse Holder for 10×38 mm Fuses | 32A | 400V AC | DIN Rail","description":"\u003cp data-start=\"160\" data-end=\"399\"\u003eThe \u003cstrong data-start=\"164\" data-end=\"178\"\u003eABB E93\/32\u003c\/strong\u003e is a \u003cstrong data-start=\"184\" data-end=\"229\"\u003ethree-phase modular fuse holder (3 poles)\u003c\/strong\u003e designed to accommodate \u003cstrong data-start=\"254\" data-end=\"289\"\u003e10×38 mm cylindrical fuse links\u003c\/strong\u003e, used for protecting electrical lines and equipment in residential, commercial, and industrial installations.\u003c\/p\u003e\n\u003cp data-start=\"401\" data-end=\"687\"\u003eThis device allows \u003cstrong data-start=\"420\" data-end=\"466\"\u003eindependent protection of the three phases\u003c\/strong\u003e using separate fuse links, providing reliable protection against overcurrents and short circuits. Its compact modular design enables easy integration into electrical distribution boards mounted on \u003cstrong data-start=\"664\" data-end=\"686\"\u003estandard DIN rails\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"689\" data-end=\"862\"\u003eABB’s robust construction ensures long service life, operational safety, and simple maintenance, with \u003cstrong data-start=\"791\" data-end=\"825\"\u003eindividual front fuse carriers\u003c\/strong\u003e for quick and safe fuse replacement.\u003c\/p\u003e\n\u003chr data-start=\"864\" data-end=\"867\"\u003e\n\u003ch2 data-start=\"869\" data-end=\"901\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"903\" data-end=\"1236\"\u003e\u003cstrong data-start=\"903\" data-end=\"913\"\u003eBrand:\u003c\/strong\u003e ABB\u003cbr data-start=\"917\" data-end=\"920\"\u003e\u003cstrong data-start=\"920\" data-end=\"930\"\u003eModel:\u003c\/strong\u003e E93\/32\u003cbr data-start=\"937\" data-end=\"940\"\u003e\u003cstrong data-start=\"940\" data-end=\"949\"\u003eType:\u003c\/strong\u003e Modular fuse holder\u003cbr data-start=\"969\" data-end=\"972\"\u003e\u003cstrong data-start=\"972\" data-end=\"992\"\u003eNumber of poles:\u003c\/strong\u003e 3P (three-phase)\u003cbr data-start=\"1009\" data-end=\"1012\"\u003e\u003cstrong data-start=\"1012\" data-end=\"1037\"\u003eCompatible fuse type:\u003c\/strong\u003e Cylindrical \u003cstrong data-start=\"1050\" data-end=\"1064\"\u003e10 × 38 mm\u003c\/strong\u003e\u003cbr data-start=\"1064\" data-end=\"1067\"\u003e\u003cstrong data-start=\"1067\" data-end=\"1085\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1086\" data-end=\"1094\"\u003e32 A\u003c\/strong\u003e\u003cbr data-start=\"1094\" data-end=\"1097\"\u003e\u003cstrong data-start=\"1097\" data-end=\"1115\"\u003eRated voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1116\" data-end=\"1128\"\u003e400 V AC\u003c\/strong\u003e\u003cbr data-start=\"1128\" data-end=\"1131\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1144\"\u003eStandard:\u003c\/strong\u003e \u003cstrong data-start=\"1145\" data-end=\"1160\"\u003eIEC 60947-3\u003c\/strong\u003e\u003cbr data-start=\"1160\" data-end=\"1163\"\u003e\u003cstrong data-start=\"1163\" data-end=\"1176\"\u003eMounting:\u003c\/strong\u003e \u003cstrong data-start=\"1177\" data-end=\"1195\"\u003eDIN rail 35 mm\u003c\/strong\u003e\u003cbr data-start=\"1195\" data-end=\"1198\"\u003e\u003cstrong data-start=\"1198\" data-end=\"1220\"\u003ePower dissipation:\u003c\/strong\u003e approx. \u003cstrong data-start=\"1229\" data-end=\"1236\"\u003e3 W\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1238\" data-end=\"1241\"\u003e\n\u003ch2 data-start=\"1243\" data-end=\"1262\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003cp data-start=\"1264\" data-end=\"1318\"\u003eThe fuse holder includes \u003cstrong data-start=\"1289\" data-end=\"1317\"\u003esix connection terminals\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp data-start=\"1320\" data-end=\"1337\"\u003e\u003cstrong data-start=\"1320\" data-end=\"1335\"\u003eLine input:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1338\" data-end=\"1355\"\u003e\n\u003cli data-start=\"1338\" data-end=\"1343\"\u003e\n\u003cp data-start=\"1340\" data-end=\"1343\"\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1344\" data-end=\"1349\"\u003e\n\u003cp data-start=\"1346\" data-end=\"1349\"\u003e3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1350\" data-end=\"1355\"\u003e\n\u003cp data-start=\"1352\" data-end=\"1355\"\u003e5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1357\" data-end=\"1375\"\u003e\u003cstrong data-start=\"1357\" data-end=\"1373\"\u003eLoad output:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1376\" data-end=\"1393\"\u003e\n\u003cli data-start=\"1376\" data-end=\"1381\"\u003e\n\u003cp data-start=\"1378\" data-end=\"1381\"\u003e2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1382\" data-end=\"1387\"\u003e\n\u003cp data-start=\"1384\" data-end=\"1387\"\u003e4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1388\" data-end=\"1393\"\u003e\n\u003cp data-start=\"1390\" data-end=\"1393\"\u003e6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1395\" data-end=\"1457\"\u003eStandard configuration for \u003cstrong data-start=\"1422\" data-end=\"1456\"\u003ethree-phase circuit protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1459\" data-end=\"1462\"\u003e\n\u003ch2 data-start=\"1464\" data-end=\"1493\"\u003e🛡 Construction Features\u003c\/h2\u003e\n\u003cp data-start=\"1495\" data-end=\"1713\"\u003e✔ Compact ABB modular design\u003cbr data-start=\"1523\" data-end=\"1526\"\u003e✔ Housing for \u003cstrong data-start=\"1540\" data-end=\"1581\"\u003ethree 10×38 mm cylindrical fuse links\u003c\/strong\u003e\u003cbr data-start=\"1581\" data-end=\"1584\"\u003e✔ Independent front fuse carriers for each phase\u003cbr data-start=\"1632\" data-end=\"1635\"\u003e✔ Robust screw terminals for secure wiring\u003cbr data-start=\"1677\" data-end=\"1680\"\u003e✔ Easy installation on DIN rail\u003c\/p\u003e\n\u003cp data-start=\"1715\" data-end=\"1781\"\u003e⚠ Safety marking on the device:\u003cbr data-start=\"1746\" data-end=\"1749\"\u003e\u003cstrong data-start=\"1749\" data-end=\"1781\"\u003e“Do not operate under load.”\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1783\" data-end=\"1786\"\u003e\n\u003ch2 data-start=\"1788\" data-end=\"1808\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1810\" data-end=\"1843\"\u003eThis fuse holder is suitable for:\u003c\/p\u003e\n\u003cp data-start=\"1845\" data-end=\"2044\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1875\" data-end=\"1878\"\u003e✔ Power distribution systems\u003cbr data-start=\"1906\" data-end=\"1909\"\u003e✔ Three-phase line protection\u003cbr data-start=\"1938\" data-end=\"1941\"\u003e✔ Photovoltaic installations\u003cbr data-start=\"1969\" data-end=\"1972\"\u003e✔ Industrial automation systems\u003cbr data-start=\"2003\" data-end=\"2006\"\u003e✔ Protection of electrical equipment\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53473980973389,"sku":null,"price":8.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5040.jpg?v=1772624555"},{"product_id":"abb-s203-c40-3p-mcb-40a-curve-c-400v-ac-6ka-s200-series","title":"ABB S203 C40 – 3P MCB 40A Curve C | 400V AC | 6kA | S200 Series","description":"\u003cp data-start=\"142\" data-end=\"483\"\u003eThe \u003cstrong data-start=\"146\" data-end=\"162\"\u003eABB S203 C40\u003c\/strong\u003e is a \u003cstrong data-start=\"168\" data-end=\"214\"\u003ethree-pole miniature circuit breaker (MCB)\u003c\/strong\u003e designed to protect electrical installations against overloads and short circuits. It belongs to the well-known \u003cstrong data-start=\"327\" data-end=\"346\"\u003eABB S200 series\u003c\/strong\u003e, widely used in residential, commercial, and industrial distribution boards for its reliability, safety, and high manufacturing quality.\u003c\/p\u003e\n\u003cp data-start=\"485\" data-end=\"687\"\u003eThis device combines \u003cstrong data-start=\"506\" data-end=\"552\"\u003ethermal protection for overload conditions\u003c\/strong\u003e with \u003cstrong data-start=\"558\" data-end=\"600\"\u003emagnetic protection for short circuits\u003c\/strong\u003e, ensuring safe and reliable protection of electrical circuits and connected equipment.\u003c\/p\u003e\n\u003cp data-start=\"689\" data-end=\"831\"\u003eThe breaker features \u003cstrong data-start=\"710\" data-end=\"745\"\u003ethree mechanically linked poles\u003c\/strong\u003e operated by a common handle, allowing simultaneous disconnection of all three phases.\u003c\/p\u003e\n\u003chr data-start=\"833\" data-end=\"836\"\u003e\n\u003ch2 data-start=\"838\" data-end=\"870\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"872\" data-end=\"1017\"\u003e\u003cstrong data-start=\"872\" data-end=\"882\"\u003eBrand:\u003c\/strong\u003e ABB\u003cbr data-start=\"886\" data-end=\"889\"\u003e\u003cstrong data-start=\"889\" data-end=\"900\"\u003eSeries:\u003c\/strong\u003e S200\u003cbr data-start=\"905\" data-end=\"908\"\u003e\u003cstrong data-start=\"908\" data-end=\"918\"\u003eModel:\u003c\/strong\u003e S203 C40\u003cbr data-start=\"927\" data-end=\"930\"\u003e\u003cstrong data-start=\"930\" data-end=\"939\"\u003eType:\u003c\/strong\u003e Miniature Circuit Breaker (MCB)\u003cbr data-start=\"971\" data-end=\"974\"\u003e\u003cstrong data-start=\"974\" data-end=\"994\"\u003eNumber of poles:\u003c\/strong\u003e \u003cstrong data-start=\"995\" data-end=\"1015\"\u003e3P (three-phase)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1019\" data-end=\"1046\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1048\" data-end=\"1216\"\u003e\n\u003cli data-start=\"1048\" data-end=\"1075\"\u003e\n\u003cp data-start=\"1050\" data-end=\"1075\"\u003eRated current: \u003cstrong data-start=\"1065\" data-end=\"1073\"\u003e40 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1076\" data-end=\"1116\"\u003e\n\u003cp data-start=\"1078\" data-end=\"1116\"\u003eTripping characteristic: \u003cstrong data-start=\"1103\" data-end=\"1114\"\u003eCurve C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1117\" data-end=\"1148\"\u003e\n\u003cp data-start=\"1119\" data-end=\"1148\"\u003eRated voltage: \u003cstrong data-start=\"1134\" data-end=\"1146\"\u003e400 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1188\"\u003e\n\u003cp data-start=\"1151\" data-end=\"1188\"\u003eMaximum voltage: \u003cstrong data-start=\"1168\" data-end=\"1186\"\u003e277 \/ 480 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1189\" data-end=\"1216\"\u003e\n\u003cp data-start=\"1191\" data-end=\"1216\"\u003eFrequency: \u003cstrong data-start=\"1202\" data-end=\"1216\"\u003e50 \/ 60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1218\" data-end=\"1243\"\u003e⚡ Breaking Capacity\u003c\/h3\u003e\n\u003cul data-start=\"1245\" data-end=\"1286\"\u003e\n\u003cli data-start=\"1245\" data-end=\"1266\"\u003e\n\u003cp data-start=\"1247\" data-end=\"1266\"\u003e\u003cstrong data-start=\"1247\" data-end=\"1264\"\u003e10 kA @ 400 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1267\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1269\" data-end=\"1286\"\u003e\u003cstrong data-start=\"1269\" data-end=\"1286\"\u003e20 kA @ 230 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1288\" data-end=\"1306\"\u003e📜 Standards\u003c\/h3\u003e\n\u003cul data-start=\"1308\" data-end=\"1348\"\u003e\n\u003cli data-start=\"1308\" data-end=\"1330\"\u003e\n\u003cp data-start=\"1310\" data-end=\"1330\"\u003e\u003cstrong data-start=\"1310\" data-end=\"1328\"\u003eIEC \/ EN 60898\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1331\" data-end=\"1348\"\u003e\n\u003cp data-start=\"1333\" data-end=\"1348\"\u003e\u003cstrong data-start=\"1333\" data-end=\"1348\"\u003eIEC 60947-2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1350\" data-end=\"1353\"\u003e\n\u003ch2 data-start=\"1355\" data-end=\"1374\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003cp data-start=\"1376\" data-end=\"1397\"\u003eConnection terminals:\u003c\/p\u003e\n\u003cp data-start=\"1399\" data-end=\"1416\"\u003e\u003cstrong data-start=\"1399\" data-end=\"1414\"\u003eLine input:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1417\" data-end=\"1434\"\u003e\n\u003cli data-start=\"1417\" data-end=\"1422\"\u003e\n\u003cp data-start=\"1419\" data-end=\"1422\"\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1423\" data-end=\"1428\"\u003e\n\u003cp data-start=\"1425\" data-end=\"1428\"\u003e3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1429\" data-end=\"1434\"\u003e\n\u003cp data-start=\"1431\" data-end=\"1434\"\u003e5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1436\" data-end=\"1454\"\u003e\u003cstrong data-start=\"1436\" data-end=\"1452\"\u003eLoad output:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1455\" data-end=\"1472\"\u003e\n\u003cli data-start=\"1455\" data-end=\"1460\"\u003e\n\u003cp data-start=\"1457\" data-end=\"1460\"\u003e2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1461\" data-end=\"1466\"\u003e\n\u003cp data-start=\"1463\" data-end=\"1466\"\u003e4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1467\" data-end=\"1472\"\u003e\n\u003cp data-start=\"1469\" data-end=\"1472\"\u003e6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1474\" data-end=\"1545\"\u003eCompatible with standard wiring used in electrical distribution panels.\u003c\/p\u003e\n\u003chr data-start=\"1547\" data-end=\"1550\"\u003e\n\u003ch2 data-start=\"1552\" data-end=\"1581\"\u003e🛡 Construction Features\u003c\/h2\u003e\n\u003cp data-start=\"1583\" data-end=\"1770\"\u003e✔ Integrated thermal and magnetic protection\u003cbr data-start=\"1627\" data-end=\"1630\"\u003e✔ Common operating lever for all three poles\u003cbr data-start=\"1674\" data-end=\"1677\"\u003e✔ Compact modular construction\u003cbr data-start=\"1707\" data-end=\"1710\"\u003e✔ High operational reliability\u003cbr data-start=\"1740\" data-end=\"1743\"\u003e✔ DIN rail mounting (35 mm)\u003c\/p\u003e\n\u003chr data-start=\"1772\" data-end=\"1775\"\u003e\n\u003ch2 data-start=\"1777\" data-end=\"1797\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1799\" data-end=\"1840\"\u003eThis circuit breaker is commonly used in:\u003c\/p\u003e\n\u003cp data-start=\"1842\" data-end=\"2063\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1872\" data-end=\"1875\"\u003e✔ Three-phase power distribution systems\u003cbr data-start=\"1915\" data-end=\"1918\"\u003e✔ Industrial automation systems\u003cbr data-start=\"1949\" data-end=\"1952\"\u003e✔ Electrical line protection\u003cbr data-start=\"1980\" data-end=\"1983\"\u003e✔ Photovoltaic installations\u003cbr data-start=\"2011\" data-end=\"2014\"\u003e✔ Protection of motors and electrical equipment\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53474051195213,"sku":null,"price":10.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5036.jpg?v=1772624885"},{"product_id":"siemens-5sm2-322-0-siemens-5sy42-c16-2p-rcbo-assembly-16a-curve-c-30ma-400v-ac-10ka","title":"Siemens 5SM2 322-0 + Siemens 5SY42 C16 – 2P RCBO Assembly | 16A Curve C | 30mA | 400V AC | 10kA","description":"\u003cp data-start=\"174\" data-end=\"464\"\u003eThis device is a \u003cstrong data-start=\"191\" data-end=\"233\"\u003emodular protection assembly by Siemens\u003c\/strong\u003e consisting of a \u003cstrong data-start=\"250\" data-end=\"285\"\u003eresidual current unit (RC Unit)\u003c\/strong\u003e combined with a \u003cstrong data-start=\"302\" data-end=\"337\"\u003eminiature circuit breaker (MCB)\u003c\/strong\u003e, designed to provide complete protection of electrical circuits against overloads, short circuits, and earth leakage currents.\u003c\/p\u003e\n\u003cp data-start=\"466\" data-end=\"493\"\u003eThe configuration includes:\u003c\/p\u003e\n\u003cul data-start=\"495\" data-end=\"609\"\u003e\n\u003cli data-start=\"495\" data-end=\"555\"\u003e\n\u003cp data-start=\"497\" data-end=\"555\"\u003e\u003cstrong data-start=\"497\" data-end=\"519\"\u003eSiemens 5SM2 322-0\u003c\/strong\u003e – Residual current unit (RC Unit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"556\" data-end=\"609\"\u003e\n\u003cp data-start=\"558\" data-end=\"609\"\u003e\u003cstrong data-start=\"558\" data-end=\"579\"\u003eSiemens 5SY42 C16\u003c\/strong\u003e – Miniature circuit breaker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"611\" data-end=\"735\"\u003eWhen assembled, the system functions similarly to a \u003cstrong data-start=\"663\" data-end=\"734\"\u003eResidual Current Circuit Breaker with Overcurrent Protection (RCBO)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"737\" data-end=\"972\"\u003eThe \u003cstrong data-start=\"741\" data-end=\"778\"\u003e30 mA residual current protection\u003c\/strong\u003e ensures personal safety by detecting leakage currents and protecting against indirect contact, while the \u003cstrong data-start=\"884\" data-end=\"916\"\u003e16 A C-curve circuit breaker\u003c\/strong\u003e protects the circuit from overloads and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"974\" data-end=\"1097\"\u003eThis modular protection solution is suitable for installation in residential, commercial, and industrial electrical panels.\u003c\/p\u003e\n\u003chr data-start=\"1099\" data-end=\"1102\"\u003e\n\u003ch2 data-start=\"1104\" data-end=\"1136\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-start=\"1138\" data-end=\"1168\"\u003e🔹 Residual Current Unit\u003c\/h3\u003e\n\u003cp data-start=\"1170\" data-end=\"1390\"\u003e\u003cstrong data-start=\"1170\" data-end=\"1180\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"1188\" data-end=\"1191\"\u003e\u003cstrong data-start=\"1191\" data-end=\"1201\"\u003eModel:\u003c\/strong\u003e 5SM2 322-0\u003cbr data-start=\"1212\" data-end=\"1215\"\u003e\u003cstrong data-start=\"1215\" data-end=\"1224\"\u003eType:\u003c\/strong\u003e RC Unit (Residual current module)\u003cbr data-start=\"1258\" data-end=\"1261\"\u003e\u003cstrong data-start=\"1261\" data-end=\"1294\"\u003eRated residual current (IΔn):\u003c\/strong\u003e \u003cstrong data-start=\"1295\" data-end=\"1313\"\u003e30 mA (0.03 A)\u003c\/strong\u003e\u003cbr data-start=\"1313\" data-end=\"1316\"\u003e\u003cstrong data-start=\"1316\" data-end=\"1336\"\u003eProtection type:\u003c\/strong\u003e Earth leakage protection\u003cbr data-start=\"1361\" data-end=\"1364\"\u003e\u003cstrong data-start=\"1364\" data-end=\"1380\"\u003eTest button:\u003c\/strong\u003e Present\u003c\/p\u003e\n\u003chr data-start=\"1392\" data-end=\"1395\"\u003e\n\u003ch3 data-start=\"1397\" data-end=\"1431\"\u003e🔹 Miniature Circuit Breaker\u003c\/h3\u003e\n\u003cp data-start=\"1433\" data-end=\"1558\"\u003e\u003cstrong data-start=\"1433\" data-end=\"1443\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"1451\" data-end=\"1454\"\u003e\u003cstrong data-start=\"1454\" data-end=\"1464\"\u003eModel:\u003c\/strong\u003e 5SY42\u003cbr data-start=\"1470\" data-end=\"1473\"\u003e\u003cstrong data-start=\"1473\" data-end=\"1491\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1492\" data-end=\"1500\"\u003e16 A\u003c\/strong\u003e\u003cbr data-start=\"1500\" data-end=\"1503\"\u003e\u003cstrong data-start=\"1503\" data-end=\"1522\"\u003eTripping curve:\u003c\/strong\u003e \u003cstrong data-start=\"1523\" data-end=\"1528\"\u003eC\u003c\/strong\u003e\u003cbr data-start=\"1528\" data-end=\"1531\"\u003e\u003cstrong data-start=\"1531\" data-end=\"1551\"\u003eNumber of poles:\u003c\/strong\u003e \u003cstrong data-start=\"1552\" data-end=\"1558\"\u003e2P\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1560\" data-end=\"1563\"\u003e\n\u003ch3 data-start=\"1565\" data-end=\"1589\"\u003e🔌 Electrical Data\u003c\/h3\u003e\n\u003cul data-start=\"1591\" data-end=\"1683\"\u003e\n\u003cli data-start=\"1591\" data-end=\"1622\"\u003e\n\u003cp data-start=\"1593\" data-end=\"1622\"\u003eRated voltage: \u003cstrong data-start=\"1608\" data-end=\"1620\"\u003e400 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1623\" data-end=\"1655\"\u003e\n\u003cp data-start=\"1625\" data-end=\"1655\"\u003eBreaking capacity: \u003cstrong data-start=\"1644\" data-end=\"1653\"\u003e10 kA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1656\" data-end=\"1683\"\u003e\n\u003cp data-start=\"1658\" data-end=\"1683\"\u003eFrequency: \u003cstrong data-start=\"1669\" data-end=\"1683\"\u003e50 \/ 60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1685\" data-end=\"1688\"\u003e\n\u003ch2 data-start=\"1690\" data-end=\"1710\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1712\" data-end=\"1868\"\u003e\n\u003cli data-start=\"1712\" data-end=\"1746\"\u003e\n\u003cp data-start=\"1714\" data-end=\"1746\"\u003eMounting on \u003cstrong data-start=\"1726\" data-end=\"1744\"\u003e35 mm DIN rail\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1812\"\u003e\n\u003cp data-start=\"1749\" data-end=\"1812\"\u003eModular structure compatible with Siemens distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1813\" data-end=\"1868\"\u003e\n\u003cp data-start=\"1815\" data-end=\"1868\"\u003eDirect coupling between RC unit and circuit breaker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1870\" data-end=\"1873\"\u003e\n\u003ch2 data-start=\"1875\" data-end=\"1895\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1897\" data-end=\"1910\"\u003eSuitable for:\u003c\/p\u003e\n\u003cp data-start=\"1912\" data-end=\"2080\"\u003e✔ Residential electrical panels\u003cbr data-start=\"1943\" data-end=\"1946\"\u003e✔ Protection of household circuits\u003cbr data-start=\"1980\" data-end=\"1983\"\u003e✔ Industrial electrical installations\u003cbr data-start=\"2020\" data-end=\"2023\"\u003e✔ Socket outlet circuits\u003cbr data-start=\"2047\" data-end=\"2050\"\u003e✔ Power distribution systems\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53474084290893,"sku":null,"price":40.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5030.jpg?v=1772625331"},{"product_id":"siemens-5sy41-c1-siemens-5st3010-as-1p-1a-mcb-with-auxiliary-contact-curve-c-230-400v-10ka","title":"Siemens 5SY41 C1 + Siemens 5ST3010 AS – 1P 1A MCB with Auxiliary Contact | Curve C | 230\/400V | 10kA","description":"\u003cp data-start=\"179\" data-end=\"428\"\u003eThis assembly consists of a \u003cstrong data-start=\"207\" data-end=\"259\"\u003eSiemens 5SY41 C1 miniature circuit breaker (MCB)\u003c\/strong\u003e combined with a \u003cstrong data-start=\"276\" data-end=\"323\"\u003eSiemens 5ST3010 AS auxiliary contact module\u003c\/strong\u003e, a configuration commonly used in electrical control panels for circuit protection and status signaling.\u003c\/p\u003e\n\u003cp data-start=\"430\" data-end=\"707\"\u003eThe \u003cstrong data-start=\"434\" data-end=\"463\"\u003eminiature circuit breaker\u003c\/strong\u003e protects the circuit against overloads and short circuits, while the \u003cstrong data-start=\"533\" data-end=\"561\"\u003eauxiliary contact module\u003c\/strong\u003e allows external systems—such as PLCs, relays, monitoring systems, or signal lamps—to detect the breaker’s operational status (ON\/OFF or tripped).\u003c\/p\u003e\n\u003cp data-start=\"709\" data-end=\"903\"\u003eWith a \u003cstrong data-start=\"716\" data-end=\"760\"\u003erated current of 1A and C tripping curve\u003c\/strong\u003e, this device is particularly suitable for protecting \u003cstrong data-start=\"814\" data-end=\"902\"\u003econtrol circuits, instrumentation, industrial automation systems, and command panels\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"905\" data-end=\"1044\"\u003eThe side-mounted auxiliary module provides \u003cstrong data-start=\"948\" data-end=\"995\"\u003enormally open (NO) and normally closed (NC)\u003c\/strong\u003e contacts for signaling and automation functions.\u003c\/p\u003e\n\u003chr data-start=\"1046\" data-end=\"1049\"\u003e\n\u003ch2 data-start=\"1051\" data-end=\"1083\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-start=\"1085\" data-end=\"1119\"\u003e🔹 Miniature Circuit Breaker\u003c\/h3\u003e\n\u003cp data-start=\"1121\" data-end=\"1322\"\u003e\u003cstrong data-start=\"1121\" data-end=\"1131\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"1139\" data-end=\"1142\"\u003e\u003cstrong data-start=\"1142\" data-end=\"1152\"\u003eModel:\u003c\/strong\u003e 5SY41\u003cbr data-start=\"1158\" data-end=\"1161\"\u003e\u003cstrong data-start=\"1161\" data-end=\"1179\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1180\" data-end=\"1187\"\u003e1 A\u003c\/strong\u003e\u003cbr data-start=\"1187\" data-end=\"1190\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1209\"\u003eTripping curve:\u003c\/strong\u003e \u003cstrong data-start=\"1210\" data-end=\"1215\"\u003eC\u003c\/strong\u003e\u003cbr data-start=\"1215\" data-end=\"1218\"\u003e\u003cstrong data-start=\"1218\" data-end=\"1238\"\u003eNumber of poles:\u003c\/strong\u003e \u003cstrong data-start=\"1239\" data-end=\"1245\"\u003e1P\u003c\/strong\u003e\u003cbr data-start=\"1245\" data-end=\"1248\"\u003e\u003cstrong data-start=\"1248\" data-end=\"1266\"\u003eRated voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1267\" data-end=\"1285\"\u003e230 \/ 400 V AC\u003c\/strong\u003e\u003cbr data-start=\"1285\" data-end=\"1288\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1310\"\u003eBreaking capacity:\u003c\/strong\u003e \u003cstrong data-start=\"1311\" data-end=\"1320\"\u003e10 kA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1324\" data-end=\"1340\"\u003e\u003cstrong data-start=\"1324\" data-end=\"1338\"\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1341\" data-end=\"1380\"\u003e\n\u003cli data-start=\"1341\" data-end=\"1359\"\u003e\n\u003cp data-start=\"1343\" data-end=\"1359\"\u003eIEC \/ EN 60898\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1360\" data-end=\"1380\"\u003e\n\u003cp data-start=\"1362\" data-end=\"1380\"\u003eIEC \/ EN 60947-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1382\" data-end=\"1385\"\u003e\n\u003ch3 data-start=\"1387\" data-end=\"1420\"\u003e🔹 Auxiliary Contact Module\u003c\/h3\u003e\n\u003cp data-start=\"1422\" data-end=\"1625\"\u003e\u003cstrong data-start=\"1422\" data-end=\"1432\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"1440\" data-end=\"1443\"\u003e\u003cstrong data-start=\"1443\" data-end=\"1453\"\u003eModel:\u003c\/strong\u003e 5ST3010 AS\u003cbr data-start=\"1464\" data-end=\"1467\"\u003e\u003cstrong data-start=\"1467\" data-end=\"1476\"\u003eType:\u003c\/strong\u003e Auxiliary signaling contact\u003cbr data-start=\"1504\" data-end=\"1507\"\u003e\u003cstrong data-start=\"1507\" data-end=\"1533\"\u003eContact configuration:\u003c\/strong\u003e \u003cstrong data-start=\"1534\" data-end=\"1549\"\u003e1 NO + 1 NC\u003c\/strong\u003e\u003cbr data-start=\"1549\" data-end=\"1552\"\u003e\u003cstrong data-start=\"1552\" data-end=\"1572\"\u003eMaximum voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1573\" data-end=\"1582\"\u003e440 V\u003c\/strong\u003e\u003cbr data-start=\"1582\" data-end=\"1585\"\u003e\u003cstrong data-start=\"1585\" data-end=\"1611\"\u003eRated contact current:\u003c\/strong\u003e \u003cstrong data-start=\"1612\" data-end=\"1625\"\u003eup to 6 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1627\" data-end=\"1630\"\u003e\n\u003ch2 data-start=\"1632\" data-end=\"1652\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1654\" data-end=\"1814\"\u003e\n\u003cli data-start=\"1654\" data-end=\"1688\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1688\"\u003eMounting on \u003cstrong data-start=\"1668\" data-end=\"1686\"\u003e35 mm DIN rail\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1689\" data-end=\"1760\"\u003e\n\u003cp data-start=\"1691\" data-end=\"1760\"\u003eDirect side connection between circuit breaker and auxiliary module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1761\" data-end=\"1814\"\u003e\n\u003cp data-start=\"1763\" data-end=\"1814\"\u003eCompatible with Siemens modular electrical panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1816\" data-end=\"1819\"\u003e\n\u003ch2 data-start=\"1821\" data-end=\"1841\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1843\" data-end=\"1853\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1855\" data-end=\"2040\"\u003e✔ Industrial automation panels\u003cbr data-start=\"1885\" data-end=\"1888\"\u003e✔ Control circuits\u003cbr data-start=\"1906\" data-end=\"1909\"\u003e✔ Breaker status signaling systems\u003cbr data-start=\"1943\" data-end=\"1946\"\u003e✔ PLC systems\u003cbr data-start=\"1959\" data-end=\"1962\"\u003e✔ Monitoring and supervisory systems\u003cbr data-start=\"1998\" data-end=\"2001\"\u003e✔ Industrial electrical installations\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53474119647565,"sku":null,"price":7.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5026.jpg?v=1772634109"},{"product_id":"wohner-nh-fuse-switch-disconnector-16a-400v-nh-fuse-switch-disconnector-16a-400v-ac-busbar-panel-mount-vde-0636","title":"Wöhner NH Fuse Switch Disconnector 16A 400V – NH Fuse Switch Disconnector | 16A | 400V AC | Busbar \/ Panel Mount | VDE 0636","description":"\u003cp data-start=\"202\" data-end=\"415\"\u003eThe \u003cstrong data-start=\"206\" data-end=\"244\"\u003eWöhner NH fuse switch disconnector\u003c\/strong\u003e is a component designed for installation in \u003cstrong data-start=\"289\" data-end=\"342\"\u003eelectrical distribution panels and busbar systems\u003c\/strong\u003e, used for housing and protecting circuits through industrial fuse links.\u003c\/p\u003e\n\u003cp data-start=\"417\" data-end=\"590\"\u003eThis device allows \u003cstrong data-start=\"436\" data-end=\"489\"\u003esafe circuit isolation and overcurrent protection\u003c\/strong\u003e using fuse technology, ensuring high reliability and operational safety in electrical installations.\u003c\/p\u003e\n\u003cp data-start=\"592\" data-end=\"824\"\u003eManufactured according to \u003cstrong data-start=\"618\" data-end=\"640\"\u003eVDE 0636 standards\u003c\/strong\u003e, the fuse holder supports a \u003cstrong data-start=\"669\" data-end=\"696\"\u003erated current up to 16A\u003c\/strong\u003e with a \u003cstrong data-start=\"704\" data-end=\"732\"\u003erated voltage of 400V AC\u003c\/strong\u003e, making it suitable for industrial power distribution panels and electrical supply systems.\u003c\/p\u003e\n\u003cp data-start=\"826\" data-end=\"1022\"\u003eIts \u003cstrong data-start=\"830\" data-end=\"865\"\u003erobust and compact construction\u003c\/strong\u003e allows easy installation in modular panel systems and provides secure electrical connections through screw terminals designed for optimal tightening torque.\u003c\/p\u003e\n\u003cp data-start=\"1024\" data-end=\"1184\"\u003eThe fuse holder’s design ensures \u003cstrong data-start=\"1057\" data-end=\"1119\"\u003eefficient heat dissipation and reliable electrical contact\u003c\/strong\u003e, maintaining stable performance even under continuous operation.\u003c\/p\u003e\n\u003chr data-start=\"1186\" data-end=\"1189\"\u003e\n\u003ch2 data-start=\"1191\" data-end=\"1223\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1225\" data-end=\"1584\"\u003e\u003cstrong data-start=\"1225\" data-end=\"1235\"\u003eBrand:\u003c\/strong\u003e Wöhner\u003cbr data-start=\"1242\" data-end=\"1245\"\u003e\u003cstrong data-start=\"1245\" data-end=\"1254\"\u003eType:\u003c\/strong\u003e Fuse holder \/ fuse switch disconnector\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e\u003cstrong data-start=\"1296\" data-end=\"1314\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1315\" data-end=\"1323\"\u003e16 A\u003c\/strong\u003e\u003cbr data-start=\"1323\" data-end=\"1326\"\u003e\u003cstrong data-start=\"1326\" data-end=\"1344\"\u003eRated voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1345\" data-end=\"1357\"\u003e400 V AC\u003c\/strong\u003e\u003cbr data-start=\"1357\" data-end=\"1360\"\u003e\u003cstrong data-start=\"1360\" data-end=\"1373\"\u003eStandard:\u003c\/strong\u003e \u003cstrong data-start=\"1374\" data-end=\"1386\"\u003eVDE 0636\u003c\/strong\u003e\u003cbr data-start=\"1386\" data-end=\"1389\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1421\"\u003eOperating temperature range:\u003c\/strong\u003e \u003cstrong data-start=\"1422\" data-end=\"1440\"\u003e-15°C to +35°C\u003c\/strong\u003e\u003cbr data-start=\"1440\" data-end=\"1443\"\u003e\u003cstrong data-start=\"1443\" data-end=\"1474\"\u003eTerminal tightening torque:\u003c\/strong\u003e \u003cstrong data-start=\"1475\" data-end=\"1489\"\u003e2.5 – 3 Nm\u003c\/strong\u003e\u003cbr data-start=\"1489\" data-end=\"1492\"\u003e\u003cstrong data-start=\"1492\" data-end=\"1505\"\u003eMaterial:\u003c\/strong\u003e High-resistance engineering plastic\u003cbr data-start=\"1541\" data-end=\"1544\"\u003e\u003cstrong data-start=\"1544\" data-end=\"1566\"\u003eConnection system:\u003c\/strong\u003e Screw terminals\u003c\/p\u003e\n\u003chr data-start=\"1586\" data-end=\"1589\"\u003e\n\u003ch2 data-start=\"1591\" data-end=\"1611\"\u003e🔧 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1613\" data-end=\"1788\"\u003e\n\u003cli data-start=\"1613\" data-end=\"1671\"\u003e\n\u003cp data-start=\"1615\" data-end=\"1671\"\u003eInstallation in modular electrical distribution panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1733\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1733\"\u003eSuitable for \u003cstrong data-start=\"1687\" data-end=\"1731\"\u003ebusbar systems or fuse mounting supports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1734\" data-end=\"1788\"\u003e\n\u003cp data-start=\"1736\" data-end=\"1788\"\u003eSecure wiring via high-reliability screw terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1790\" data-end=\"1793\"\u003e\n\u003ch2 data-start=\"1795\" data-end=\"1815\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1817\" data-end=\"1825\"\u003eUsed in:\u003c\/p\u003e\n\u003cp data-start=\"1827\" data-end=\"2006\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1857\" data-end=\"1860\"\u003e✔ Power distribution systems\u003cbr data-start=\"1888\" data-end=\"1891\"\u003e✔ Industrial automation installations\u003cbr data-start=\"1928\" data-end=\"1931\"\u003e✔ Fuse-based circuit protection\u003cbr data-start=\"1962\" data-end=\"1965\"\u003e✔ Three-phase electrical supply systems\u003c\/p\u003e","brand":"Wöhner","offers":[{"title":"Default Title","offer_id":53474842476877,"sku":null,"price":10.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5014.jpg?v=1772636599"},{"product_id":"iskra-zascite-protec-c-40-320-type-2-spd-3p-pen-320v-ac-40ka","title":"Iskra Zaščite PROTEC C 40\/320 – Type 2 SPD | 3P+PEN | 320V AC | 40kA |","description":"\u003cp data-start=\"185\" data-end=\"443\"\u003eThe \u003cstrong data-start=\"189\" data-end=\"222\"\u003eIskra Zaščite PROTEC C 40\/320\u003c\/strong\u003e is a \u003cstrong data-start=\"228\" data-end=\"268\"\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e designed to protect electrical installations and equipment from transient overvoltages caused by \u003cstrong data-start=\"366\" data-end=\"442\"\u003eindirect lightning strikes or switching surges in the electrical network\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"445\" data-end=\"704\"\u003eThis model features a \u003cstrong data-start=\"467\" data-end=\"493\"\u003e3P + PEN configuration\u003c\/strong\u003e, making it suitable for \u003cstrong data-start=\"518\" data-end=\"590\"\u003ethree-phase power distribution systems with a combined PEN conductor\u003c\/strong\u003e, typically found in \u003cstrong data-start=\"611\" data-end=\"638\"\u003eTN-C electrical systems\u003c\/strong\u003e used in industrial installations and power distribution networks.\u003c\/p\u003e\n\u003cp data-start=\"706\" data-end=\"944\"\u003eDesigned for installation inside electrical distribution boards, the device mounts on a \u003cstrong data-start=\"794\" data-end=\"815\"\u003estandard DIN rail\u003c\/strong\u003e, providing reliable protection for electrical systems, automation equipment, sensitive electronics, and critical infrastructure.\u003c\/p\u003e\n\u003cp data-start=\"946\" data-end=\"1138\"\u003eThe \u003cstrong data-start=\"950\" data-end=\"969\"\u003ePROTEC C 40\/320\u003c\/strong\u003e offers a \u003cstrong data-start=\"979\" data-end=\"1017\"\u003enominal discharge current of 20 kA\u003c\/strong\u003e and a \u003cstrong data-start=\"1024\" data-end=\"1065\"\u003emaximum discharge current up to 40 kA\u003c\/strong\u003e, ensuring strong protection against voltage spikes and transient surges.\u003c\/p\u003e\n\u003chr data-start=\"1140\" data-end=\"1143\"\u003e\n\u003ch2 data-start=\"1145\" data-end=\"1177\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1179\" data-end=\"1374\"\u003e\u003cstrong data-start=\"1179\" data-end=\"1189\"\u003eBrand:\u003c\/strong\u003e Iskra Zaščite\u003cbr data-start=\"1203\" data-end=\"1206\"\u003e\u003cstrong data-start=\"1206\" data-end=\"1217\"\u003eSeries:\u003c\/strong\u003e PROTEC\u003cbr data-start=\"1224\" data-end=\"1227\"\u003e\u003cstrong data-start=\"1227\" data-end=\"1237\"\u003eModel:\u003c\/strong\u003e PROTEC C 40\/320\u003cbr data-start=\"1253\" data-end=\"1256\"\u003e\u003cstrong data-start=\"1256\" data-end=\"1272\"\u003eDevice type:\u003c\/strong\u003e Surge Protection Device (SPD)\u003cbr data-start=\"1302\" data-end=\"1305\"\u003e\u003cstrong data-start=\"1305\" data-end=\"1319\"\u003eSPD Class:\u003c\/strong\u003e \u003cstrong data-start=\"1320\" data-end=\"1340\"\u003eType 2 (Class C)\u003c\/strong\u003e\u003cbr data-start=\"1340\" data-end=\"1343\"\u003e\u003cstrong data-start=\"1343\" data-end=\"1361\"\u003eConfiguration:\u003c\/strong\u003e \u003cstrong data-start=\"1362\" data-end=\"1374\"\u003e3P + PEN\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1376\" data-end=\"1403\"\u003e🔌 Electrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1405\" data-end=\"1510\"\u003e\n\u003cli data-start=\"1405\" data-end=\"1464\"\u003e\n\u003cp data-start=\"1407\" data-end=\"1464\"\u003eMaximum continuous operating voltage (Uc): \u003cstrong data-start=\"1450\" data-end=\"1462\"\u003e320 V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1465\" data-end=\"1510\"\u003e\n\u003cp data-start=\"1467\" data-end=\"1510\"\u003eVoltage protection level (Up): \u003cstrong data-start=\"1498\" data-end=\"1510\"\u003e≤ 1.5 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1512\" data-end=\"1537\"\u003e⚡ Discharge Current\u003c\/h3\u003e\n\u003cul data-start=\"1539\" data-end=\"1630\"\u003e\n\u003cli data-start=\"1539\" data-end=\"1584\"\u003e\n\u003cp data-start=\"1541\" data-end=\"1584\"\u003eNominal discharge current (In): \u003cstrong data-start=\"1573\" data-end=\"1582\"\u003e20 kA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1585\" data-end=\"1630\"\u003e\n\u003cp data-start=\"1587\" data-end=\"1630\"\u003eMaximum discharge current (Imax): \u003cstrong data-start=\"1621\" data-end=\"1630\"\u003e40 kA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1632\" data-end=\"1635\"\u003e\n\u003ch2 data-start=\"1637\" data-end=\"1657\"\u003e🔧 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1659\" data-end=\"1822\"\u003e\n\u003cli data-start=\"1659\" data-end=\"1693\"\u003e\n\u003cp data-start=\"1661\" data-end=\"1693\"\u003eMounting on \u003cstrong data-start=\"1673\" data-end=\"1691\"\u003e35 mm DIN rail\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1694\" data-end=\"1755\"\u003e\n\u003cp data-start=\"1696\" data-end=\"1755\"\u003eInstallation in \u003cstrong data-start=\"1712\" data-end=\"1753\"\u003emain or secondary distribution boards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1756\" data-end=\"1822\"\u003e\n\u003cp data-start=\"1758\" data-end=\"1822\"\u003eDirect connection to \u003cstrong data-start=\"1779\" data-end=\"1822\"\u003ethree-phase networks with PEN conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1824\" data-end=\"1827\"\u003e\n\u003ch2 data-start=\"1829\" data-end=\"1858\"\u003e🔌 Additional Protection\u003c\/h2\u003e\n\u003cp data-start=\"1860\" data-end=\"1909\"\u003eA \u003cstrong data-start=\"1862\" data-end=\"1877\"\u003ebackup fuse\u003c\/strong\u003e is required for safe operation:\u003c\/p\u003e\n\u003cul data-start=\"1911\" data-end=\"1954\"\u003e\n\u003cli data-start=\"1911\" data-end=\"1954\"\u003e\n\u003cp data-start=\"1913\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1913\" data-end=\"1941\"\u003eRecommended backup fuse:\u003c\/strong\u003e \u003cstrong data-start=\"1942\" data-end=\"1954\"\u003e125 A gL\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1956\" data-end=\"1959\"\u003e\n\u003ch2 data-start=\"1961\" data-end=\"1981\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1983\" data-end=\"1993\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1995\" data-end=\"2257\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"2025\" data-end=\"2028\"\u003e✔ Three-phase power distribution systems\u003cbr data-start=\"2068\" data-end=\"2071\"\u003e✔ Industrial automation installations\u003cbr data-start=\"2108\" data-end=\"2111\"\u003e✔ Protection of sensitive electronic equipment\u003cbr data-start=\"2157\" data-end=\"2160\"\u003e✔ Commercial and industrial buildings\u003cbr data-start=\"2197\" data-end=\"2200\"\u003e✔ Photovoltaic systems and energy distribution networks\u003c\/p\u003e","brand":"Iskra Zaščite","offers":[{"title":"Default Title","offer_id":53482828955981,"sku":null,"price":30.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4864.jpg?v=1772710453"},{"product_id":"ebm-papst-4184-ngx-119-119-38-mm-axial-fan-24v-dc-3-5w-industrial-cooling-fan","title":"ebm-papst 4184 NGX – 119×119×38 mm Axial Fan | 24V DC | 3.5W | Industrial Cooling Fan","description":"\u003cp data-start=\"161\" data-end=\"348\"\u003eThe \u003cstrong data-start=\"165\" data-end=\"187\"\u003eebm-papst 4184 NGX\u003c\/strong\u003e is a \u003cstrong data-start=\"193\" data-end=\"235\"\u003ecompact and reliable axial cooling fan\u003c\/strong\u003e designed for \u003cstrong data-start=\"249\" data-end=\"291\"\u003eindustrial and electronic applications\u003c\/strong\u003e requiring continuous cooling with low power consumption.\u003c\/p\u003e\n\u003cp data-start=\"350\" data-end=\"550\"\u003ePowered by \u003cstrong data-start=\"361\" data-end=\"371\"\u003e24V DC\u003c\/strong\u003e, this fan offers an excellent balance between \u003cstrong data-start=\"418\" data-end=\"463\"\u003eenergy efficiency and cooling performance\u003c\/strong\u003e, making it ideal for systems that require constant airflow without high energy demand.\u003c\/p\u003e\n\u003cp data-start=\"552\" data-end=\"733\"\u003eThe \u003cstrong data-start=\"556\" data-end=\"569\"\u003eebm-papst\u003c\/strong\u003e brand is widely recognized for its \u003cstrong data-start=\"605\" data-end=\"670\"\u003ehigh-quality construction, reliability, and long service life\u003c\/strong\u003e, making this model a dependable solution for professional use.\u003c\/p\u003e\n\u003chr data-start=\"735\" data-end=\"738\"\u003e\n\u003ch2 data-section-id=\"1hmgiha\" data-start=\"740\" data-end=\"772\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"774\" data-end=\"818\"\u003e\u003cstrong data-start=\"774\" data-end=\"784\"\u003eBrand:\u003c\/strong\u003e ebm-papst\u003cbr data-start=\"794\" data-end=\"797\"\u003e\u003cstrong data-start=\"797\" data-end=\"807\"\u003eModel:\u003c\/strong\u003e 4184 NGX\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r3xgf7\" data-start=\"820\" data-end=\"850\"\u003e🔌 Electrical Parameters\u003c\/h3\u003e\n\u003cul data-start=\"852\" data-end=\"983\"\u003e\n\u003cli data-section-id=\"1t2ljz5\" data-start=\"852\" data-end=\"882\"\u003e\n\u003cp data-start=\"854\" data-end=\"882\"\u003eRated voltage: \u003cstrong data-start=\"869\" data-end=\"880\"\u003e24 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hxwjkg\" data-start=\"883\" data-end=\"928\"\u003e\n\u003cp data-start=\"885\" data-end=\"928\"\u003eOperating voltage range: \u003cstrong data-start=\"910\" data-end=\"926\"\u003e12 – 30 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lwryh3\" data-start=\"929\" data-end=\"952\"\u003e\n\u003cp data-start=\"931\" data-end=\"952\"\u003eCurrent: \u003cstrong data-start=\"940\" data-end=\"950\"\u003e145 mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j35at3\" data-start=\"953\" data-end=\"983\"\u003e\n\u003cp data-start=\"955\" data-end=\"983\"\u003ePower consumption: \u003cstrong data-start=\"974\" data-end=\"983\"\u003e3.5 W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"985\" data-end=\"988\"\u003e\n\u003ch3 data-section-id=\"sjwdr2\" data-start=\"990\" data-end=\"1025\"\u003e🛠 Mechanical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1027\" data-end=\"1183\"\u003e\n\u003cli data-section-id=\"wbcy5s\" data-start=\"1027\" data-end=\"1072\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1072\"\u003eDimensions: approx. \u003cstrong data-start=\"1049\" data-end=\"1070\"\u003e119 × 119 × 38 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"145hhr2\" data-start=\"1073\" data-end=\"1096\"\u003e\n\u003cp data-start=\"1075\" data-end=\"1096\"\u003eType: \u003cstrong data-start=\"1081\" data-end=\"1094\"\u003eAxial fan\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"55dgm6\" data-start=\"1097\" data-end=\"1139\"\u003e\n\u003cp data-start=\"1099\" data-end=\"1139\"\u003eMounting: \u003cstrong data-start=\"1109\" data-end=\"1137\"\u003eStandard 4-hole mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s4cd2x\" data-start=\"1140\" data-end=\"1183\"\u003e\n\u003cp data-start=\"1142\" data-end=\"1183\"\u003eMaterial: \u003cstrong data-start=\"1152\" data-end=\"1183\"\u003eDurable engineering plastic\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1185\" data-end=\"1188\"\u003e\n\u003ch3 data-section-id=\"1mpg2j6\" data-start=\"1190\" data-end=\"1210\"\u003e🔌 Connections\u003c\/h3\u003e\n\u003cul data-start=\"1212\" data-end=\"1325\"\u003e\n\u003cli data-section-id=\"1l2lc\" data-start=\"1212\" data-end=\"1284\"\u003e\n\u003cp data-start=\"1214\" data-end=\"1238\"\u003eNumber of wires: \u003cstrong data-start=\"1231\" data-end=\"1236\"\u003e2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1241\" data-end=\"1284\"\u003e\n\u003cli data-section-id=\"1bpxsp5\" data-start=\"1241\" data-end=\"1261\"\u003e\n\u003cp data-start=\"1243\" data-end=\"1261\"\u003e\u003cstrong data-start=\"1243\" data-end=\"1259\"\u003ePositive (+)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mk29a1\" data-start=\"1264\" data-end=\"1284\"\u003e\n\u003cp data-start=\"1266\" data-end=\"1284\"\u003e\u003cstrong data-start=\"1266\" data-end=\"1282\"\u003eNegative (–)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"51xc7m\" data-start=\"1285\" data-end=\"1325\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1325\"\u003eInstallation: \u003cstrong data-start=\"1301\" data-end=\"1325\"\u003eDirect DC connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1327\" data-end=\"1330\"\u003e\n\u003ch2 data-section-id=\"10tfdtf\" data-start=\"1332\" data-end=\"1364\"\u003e🌬 Performance \u0026amp; Advantages\u003c\/h2\u003e\n\u003cul data-start=\"1366\" data-end=\"1511\"\u003e\n\u003cli data-section-id=\"1lawneu\" data-start=\"1366\" data-end=\"1391\"\u003e\n\u003cp data-start=\"1368\" data-end=\"1391\"\u003eLow power consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19ipqp4\" data-start=\"1392\" data-end=\"1425\"\u003e\n\u003cp data-start=\"1394\" data-end=\"1425\"\u003eReliable continuous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o40qij\" data-start=\"1426\" data-end=\"1454\"\u003e\n\u003cp data-start=\"1428\" data-end=\"1454\"\u003eGood airflow performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1flaa54\" data-start=\"1455\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1457\" data-end=\"1478\"\u003eRobust construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v5msi5\" data-start=\"1479\" data-end=\"1511\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1511\"\u003eLow maintenance requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1513\" data-end=\"1516\"\u003e\n\u003ch2 data-section-id=\"1d4s25f\" data-start=\"1518\" data-end=\"1538\"\u003e🔧 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1540\" data-end=\"1665\"\u003e\n\u003cli data-section-id=\"1cdhogk\" data-start=\"1540\" data-end=\"1571\"\u003e\n\u003cp data-start=\"1542\" data-end=\"1571\"\u003ePanel or enclosure mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8dct8z\" data-start=\"1572\" data-end=\"1620\"\u003e\n\u003cp data-start=\"1574\" data-end=\"1620\"\u003eDirect connection to \u003cstrong data-start=\"1595\" data-end=\"1618\"\u003e24V DC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d7388s\" data-start=\"1621\" data-end=\"1665\"\u003e\n\u003cp data-start=\"1623\" data-end=\"1665\"\u003eEasy integration into electrical systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1667\" data-end=\"1670\"\u003e\n\u003ch2 data-section-id=\"khwi0t\" data-start=\"1672\" data-end=\"1692\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1694\" data-end=\"1704\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1706\" data-end=\"1865\"\u003e✔ Photovoltaic inverters\u003cbr data-start=\"1730\" data-end=\"1733\"\u003e✔ Electrical panels\u003cbr data-start=\"1752\" data-end=\"1755\"\u003e✔ Industrial electronics\u003cbr data-start=\"1779\" data-end=\"1782\"\u003e✔ Automation systems\u003cbr data-start=\"1802\" data-end=\"1805\"\u003e✔ Power supplies and UPS\u003cbr data-start=\"1829\" data-end=\"1832\"\u003e✔ Technical ventilation systems\u003c\/p\u003e\n\u003chr data-start=\"1867\" data-end=\"1870\"\u003e\n\u003ch2 data-section-id=\"1yc8hbc\" data-start=\"1872\" data-end=\"1898\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"1900\" data-end=\"2196\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"1904\" data-end=\"1926\"\u003eebm-papst 4184 NGX\u003c\/strong\u003e is an energy-efficient \u003cstrong data-start=\"1950\" data-end=\"1970\"\u003e24V DC axial fan\u003c\/strong\u003e, designed for continuous industrial cooling applications. With \u003cstrong data-start=\"2034\" data-end=\"2101\"\u003elow power consumption, reliable performance, and compact design\u003c\/strong\u003e, it is an excellent choice for cooling electrical panels, inverters, and electronic equipmen\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53558880436557,"sku":null,"price":35.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5113.jpg?v=1773913032"},{"product_id":"ebm-papst-4414-fl-119-119-25-mm-axial-fan-24v-dc-1w-low-power-slim-design-with-connector","title":"ebm-papst 4414 FL – 119×119×25 mm Axial Fan | 24V DC | 1W | Low Power | Slim Design with Connector","description":"\u003cp data-start=\"174\" data-end=\"344\"\u003eThe \u003cstrong data-start=\"178\" data-end=\"199\"\u003eebm-papst 4414 FL\u003c\/strong\u003e is a \u003cstrong data-start=\"205\" data-end=\"236\"\u003elow-power axial cooling fan\u003c\/strong\u003e designed for \u003cstrong data-start=\"250\" data-end=\"343\"\u003eelectronic applications requiring quiet operation, energy efficiency, and continuous duty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"346\" data-end=\"546\"\u003eWith an extremely low power consumption of \u003cstrong data-start=\"389\" data-end=\"400\"\u003ejust 1W\u003c\/strong\u003e, this fan is ideal for systems where \u003cstrong data-start=\"438\" data-end=\"471\"\u003eenergy efficiency is critical\u003c\/strong\u003e, while still providing effective airflow for cooling sensitive components.\u003c\/p\u003e\n\u003cp data-start=\"548\" data-end=\"714\"\u003eIts \u003cstrong data-start=\"552\" data-end=\"585\"\u003eslim design (25 mm thickness)\u003c\/strong\u003e makes it particularly suitable for installations with \u003cstrong data-start=\"640\" data-end=\"657\"\u003elimited space\u003c\/strong\u003e, offering flexibility in compact enclosures and devices.\u003c\/p\u003e\n\u003cp data-start=\"716\" data-end=\"878\"\u003eAs part of the \u003cstrong data-start=\"731\" data-end=\"750\"\u003eebm-papst range\u003c\/strong\u003e, this model ensures \u003cstrong data-start=\"771\" data-end=\"834\"\u003ehigh reliability, long service life, and stable performance\u003c\/strong\u003e, even in continuous operation environments.\u003c\/p\u003e\n\u003chr data-start=\"880\" data-end=\"883\"\u003e\n\u003ch2 data-section-id=\"1hmgiha\" data-start=\"885\" data-end=\"917\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"919\" data-end=\"962\"\u003e\u003cstrong data-start=\"919\" data-end=\"929\"\u003eBrand:\u003c\/strong\u003e ebm-papst\u003cbr data-start=\"939\" data-end=\"942\"\u003e\u003cstrong data-start=\"942\" data-end=\"952\"\u003eModel:\u003c\/strong\u003e 4414 FL\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r3xgf7\" data-start=\"964\" data-end=\"994\"\u003e🔌 Electrical Parameters\u003c\/h3\u003e\n\u003cul data-start=\"996\" data-end=\"1124\"\u003e\n\u003cli data-section-id=\"1t2ljz5\" data-start=\"996\" data-end=\"1026\"\u003e\n\u003cp data-start=\"998\" data-end=\"1026\"\u003eRated voltage: \u003cstrong data-start=\"1013\" data-end=\"1024\"\u003e24 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18yyr9v\" data-start=\"1027\" data-end=\"1072\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1072\"\u003eOperating voltage range: \u003cstrong data-start=\"1054\" data-end=\"1070\"\u003e18 – 28 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5y49n5\" data-start=\"1073\" data-end=\"1095\"\u003e\n\u003cp data-start=\"1075\" data-end=\"1095\"\u003eCurrent: \u003cstrong data-start=\"1084\" data-end=\"1093\"\u003e42 mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10jk1ta\" data-start=\"1096\" data-end=\"1124\"\u003e\n\u003cp data-start=\"1098\" data-end=\"1124\"\u003ePower consumption: \u003cstrong data-start=\"1117\" data-end=\"1124\"\u003e1 W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1126\" data-end=\"1129\"\u003e\n\u003ch3 data-section-id=\"sjwdr2\" data-start=\"1131\" data-end=\"1166\"\u003e🛠 Mechanical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1168\" data-end=\"1371\"\u003e\n\u003cli data-section-id=\"wzyopo\" data-start=\"1168\" data-end=\"1213\"\u003e\n\u003cp data-start=\"1170\" data-end=\"1213\"\u003eDimensions: approx. \u003cstrong data-start=\"1190\" data-end=\"1211\"\u003e119 × 119 × 25 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"145hhr2\" data-start=\"1214\" data-end=\"1237\"\u003e\n\u003cp data-start=\"1216\" data-end=\"1237\"\u003eType: \u003cstrong data-start=\"1222\" data-end=\"1235\"\u003eAxial fan\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rcm8i0\" data-start=\"1238\" data-end=\"1278\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1278\"\u003eDesign: \u003cstrong data-start=\"1248\" data-end=\"1276\"\u003eSlim (reduced thickness)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"55dgm6\" data-start=\"1279\" data-end=\"1321\"\u003e\n\u003cp data-start=\"1281\" data-end=\"1321\"\u003eMounting: \u003cstrong data-start=\"1291\" data-end=\"1319\"\u003eStandard 4-hole mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6ow5di\" data-start=\"1322\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1324\" data-end=\"1371\"\u003eMaterial: \u003cstrong data-start=\"1334\" data-end=\"1371\"\u003eHigh-strength engineering plastic\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch3 data-section-id=\"1mpg2j6\" data-start=\"1378\" data-end=\"1398\"\u003e🔌 Connections\u003c\/h3\u003e\n\u003cul data-start=\"1400\" data-end=\"1502\"\u003e\n\u003cli data-section-id=\"1fuz0r4\" data-start=\"1400\" data-end=\"1426\"\u003e\n\u003cp data-start=\"1402\" data-end=\"1426\"\u003eNumber of wires: \u003cstrong data-start=\"1419\" data-end=\"1424\"\u003e2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jrvx0p\" data-start=\"1427\" data-end=\"1454\"\u003e\n\u003cp data-start=\"1429\" data-end=\"1454\"\u003eConnector: \u003cstrong data-start=\"1440\" data-end=\"1452\"\u003eIncluded\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c2fqux\" data-start=\"1455\" data-end=\"1502\"\u003e\n\u003cp data-start=\"1457\" data-end=\"1502\"\u003eInstallation: \u003cstrong data-start=\"1471\" data-end=\"1502\"\u003eDirect connection to 24V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1504\" data-end=\"1507\"\u003e\n\u003ch2 data-section-id=\"10tfdtf\" data-start=\"1509\" data-end=\"1541\"\u003e🌬 Performance \u0026amp; Advantages\u003c\/h2\u003e\n\u003cul data-start=\"1543\" data-end=\"1712\"\u003e\n\u003cli data-section-id=\"kqbg2t\" data-start=\"1543\" data-end=\"1578\"\u003e\n\u003cp data-start=\"1545\" data-end=\"1578\"\u003eExtremely low power consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1au475t\" data-start=\"1579\" data-end=\"1598\"\u003e\n\u003cp data-start=\"1581\" data-end=\"1598\"\u003eQuiet operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"34l2ij\" data-start=\"1599\" data-end=\"1639\"\u003e\n\u003cp data-start=\"1601\" data-end=\"1639\"\u003eHigh reliability (ebm-papst quality)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nv1xui\" data-start=\"1640\" data-end=\"1677\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1677\"\u003eSuitable for continuous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tfvv6w\" data-start=\"1678\" data-end=\"1712\"\u003e\n\u003cp data-start=\"1680\" data-end=\"1712\"\u003eCompact and lightweight design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1714\" data-end=\"1717\"\u003e\n\u003ch2 data-section-id=\"1d4s25f\" data-start=\"1719\" data-end=\"1739\"\u003e🔧 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1741\" data-end=\"1878\"\u003e\n\u003cli data-section-id=\"1cdhogk\" data-start=\"1741\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1743\" data-end=\"1772\"\u003ePanel or enclosure mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8dct8z\" data-start=\"1773\" data-end=\"1821\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1821\"\u003eDirect connection to \u003cstrong data-start=\"1796\" data-end=\"1819\"\u003e24V DC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w5dmir\" data-start=\"1822\" data-end=\"1878\"\u003e\n\u003cp data-start=\"1824\" data-end=\"1878\"\u003eIdeal for compact systems and low-power applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1880\" data-end=\"1883\"\u003e\n\u003ch2 data-section-id=\"khwi0t\" data-start=\"1885\" data-end=\"1905\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1907\" data-end=\"1917\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1919\" data-end=\"2069\"\u003e✔ Photovoltaic inverters\u003cbr data-start=\"1943\" data-end=\"1946\"\u003e✔ Control electronics\u003cbr data-start=\"1967\" data-end=\"1970\"\u003e✔ Electrical panels\u003cbr data-start=\"1989\" data-end=\"1992\"\u003e✔ Embedded systems\u003cbr data-start=\"2010\" data-end=\"2013\"\u003e✔ Low-power devices\u003cbr data-start=\"2032\" data-end=\"2035\"\u003e✔ Internal equipment ventilation\u003c\/p\u003e\n\u003chr data-start=\"2071\" data-end=\"2074\"\u003e\n\u003ch2 data-section-id=\"76b74u\" data-start=\"2076\" data-end=\"2100\"\u003e📦 Package Contents\u003c\/h2\u003e\n\u003cul data-start=\"2102\" data-end=\"2138\"\u003e\n\u003cli data-section-id=\"82wmqc\" data-start=\"2102\" data-end=\"2138\"\u003e\n\u003cp data-start=\"2104\" data-end=\"2138\"\u003e\u003cstrong data-start=\"2104\" data-end=\"2138\"\u003e1× ebm-papst 4414 FL axial fan\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2140\" data-end=\"2143\"\u003e\n\u003ch2 data-section-id=\"1c4vc31\" data-start=\"2145\" data-end=\"2162\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cul data-start=\"2164\" data-end=\"2229\"\u003e\n\u003cli data-section-id=\"1xfamck\" data-start=\"2164\" data-end=\"2180\"\u003e\n\u003cp data-start=\"2166\" data-end=\"2180\"\u003eUsed product\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1refj0x\" data-start=\"2181\" data-end=\"2208\"\u003e\n\u003cp data-start=\"2183\" data-end=\"2208\"\u003eGood cosmetic condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"abwdwt\" data-start=\"2209\" data-end=\"2229\"\u003e\n\u003cp data-start=\"2211\" data-end=\"2229\"\u003eFully functional\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2231\" data-end=\"2234\"\u003e\n\u003ch2 data-section-id=\"1yc8hbc\" data-start=\"2236\" data-end=\"2262\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2264\" data-end=\"2552\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"2268\" data-end=\"2289\"\u003eebm-papst 4414 FL\u003c\/strong\u003e is a compact and energy-efficient \u003cstrong data-start=\"2324\" data-end=\"2344\"\u003e24V DC axial fan\u003c\/strong\u003e, consuming only \u003cstrong data-start=\"2361\" data-end=\"2367\"\u003e1W\u003c\/strong\u003e, ideal for low-power and space-constrained applications. With quiet operation and reliable performance, it is a perfect solution for cooling electronic systems and sensitive equipment.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53558945481037,"sku":null,"price":25.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5116.jpg?v=1773913799"},{"product_id":"chint-ddsu666-h-smart-energy-meter-1-phase-230v-100a-rs485-modbus-din-rail-smart-power-sensor","title":"CHINT DDSU666-H – Smart Energy Meter | 1-Phase 230V | 100A | RS485 Modbus | DIN Rail | Smart Power Sensor","description":"\u003cp data-start=\"181\" data-end=\"376\"\u003eThe \u003cstrong data-start=\"185\" data-end=\"204\"\u003eCHINT DDSU666-H\u003c\/strong\u003e is a \u003cstrong data-start=\"210\" data-end=\"260\"\u003esingle-phase smart energy meter (power sensor)\u003c\/strong\u003e designed for \u003cstrong data-start=\"274\" data-end=\"322\"\u003eaccurate monitoring of electrical parameters\u003c\/strong\u003e in residential, commercial, and photovoltaic systems.\u003c\/p\u003e\n\u003cp data-start=\"378\" data-end=\"595\"\u003eWidely used in \u003cstrong data-start=\"393\" data-end=\"467\"\u003ePV systems (especially for inverter integration and energy management)\u003c\/strong\u003e, this device provides \u003cstrong data-start=\"490\" data-end=\"552\"\u003ereal-time measurement of power consumption and energy flow\u003c\/strong\u003e, enabling advanced monitoring and control.\u003c\/p\u003e\n\u003cp data-start=\"597\" data-end=\"755\"\u003eIts \u003cstrong data-start=\"601\" data-end=\"628\"\u003ecompact DIN rail design\u003c\/strong\u003e, combined with \u003cstrong data-start=\"644\" data-end=\"674\"\u003eRS485 Modbus communication\u003c\/strong\u003e, makes it ideal for integration into electrical panels and smart energy systems.\u003c\/p\u003e\n\u003chr data-start=\"757\" data-end=\"760\"\u003e\n\u003ch2 data-start=\"762\" data-end=\"794\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"796\" data-end=\"917\"\u003e\n\u003cli data-start=\"796\" data-end=\"816\"\u003e\n\u003cstrong data-start=\"798\" data-end=\"808\"\u003eBrand:\u003c\/strong\u003e CHINT\u003c\/li\u003e\n\u003cli data-start=\"817\" data-end=\"841\"\u003e\n\u003cstrong data-start=\"819\" data-end=\"829\"\u003eModel:\u003c\/strong\u003e DDSU666-H\u003c\/li\u003e\n\u003cli data-start=\"842\" data-end=\"889\"\u003e\n\u003cstrong data-start=\"844\" data-end=\"853\"\u003eType:\u003c\/strong\u003e Smart Power Sensor \/ Energy Meter\u003c\/li\u003e\n\u003cli data-start=\"890\" data-end=\"917\"\u003e\n\u003cstrong data-start=\"892\" data-end=\"902\"\u003ePhase:\u003c\/strong\u003e Single-phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"919\" data-end=\"949\"\u003e🔌 Electrical Parameters\u003c\/h3\u003e\n\u003cul data-start=\"951\" data-end=\"1129\"\u003e\n\u003cli data-start=\"951\" data-end=\"984\"\u003e\n\u003cstrong data-start=\"953\" data-end=\"973\"\u003eNominal voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\u003cli data-start=\"985\" data-end=\"1067\"\u003e\n\u003cstrong data-start=\"987\" data-end=\"999\"\u003eCurrent:\u003c\/strong\u003e\n\u003cul data-start=\"1004\" data-end=\"1067\"\u003e\n\u003cli data-start=\"1004\" data-end=\"1031\"\u003e\n\u003cstrong data-start=\"1006\" data-end=\"1017\"\u003eDirect:\u003c\/strong\u003e up to 100 A\u003c\/li\u003e\n\u003cli data-start=\"1034\" data-end=\"1067\"\u003e\n\u003cstrong data-start=\"1036\" data-end=\"1059\"\u003eMeasurement output:\u003c\/strong\u003e 40 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1068\" data-end=\"1097\"\u003e\n\u003cstrong data-start=\"1070\" data-end=\"1084\"\u003eFrequency:\u003c\/strong\u003e 50 \/ 60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1098\" data-end=\"1129\"\u003e\n\u003cstrong data-start=\"1100\" data-end=\"1119\"\u003eAccuracy class:\u003c\/strong\u003e Class 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1131\" data-end=\"1134\"\u003e\n\u003ch2 data-start=\"1136\" data-end=\"1170\"\u003e🔗 Communication \u0026amp; Interfaces\u003c\/h2\u003e\n\u003cul data-start=\"1172\" data-end=\"1372\"\u003e\n\u003cli data-start=\"1172\" data-end=\"1212\"\u003e\u003cstrong data-start=\"1174\" data-end=\"1210\"\u003eRS485 communication (Modbus RTU)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1263\"\u003eTerminals for communication: \u003cstrong data-start=\"1244\" data-end=\"1261\"\u003eA \/ B (RS485)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1264\" data-end=\"1372\"\u003eSuitable for integration with:\u003cbr data-start=\"1296\" data-end=\"1299\"\u003e✔ Inverters\u003cbr data-start=\"1312\" data-end=\"1315\"\u003e✔ Energy management systems\u003cbr data-start=\"1344\" data-end=\"1347\"\u003e✔ PLC \/ SCADA systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1374\" data-end=\"1377\"\u003e\n\u003ch2 data-start=\"1379\" data-end=\"1402\"\u003e🖥️ User Interface\u003c\/h2\u003e\n\u003cul data-start=\"1404\" data-end=\"1537\"\u003e\n\u003cli data-start=\"1404\" data-end=\"1452\"\u003e\n\u003cstrong data-start=\"1406\" data-end=\"1427\"\u003eFront LCD display\u003c\/strong\u003e for real-time readings\u003c\/li\u003e\n\u003cli data-start=\"1453\" data-end=\"1495\"\u003e\n\u003cstrong data-start=\"1455\" data-end=\"1476\"\u003eNavigation button\u003c\/strong\u003e for menu control\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1537\"\u003eLED indicator for pulse\/output status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1539\" data-end=\"1542\"\u003e\n\u003ch2 data-start=\"1544\" data-end=\"1563\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003cul data-start=\"1565\" data-end=\"1705\"\u003e\n\u003cli data-start=\"1565\" data-end=\"1602\"\u003e\u003cstrong data-start=\"1567\" data-end=\"1600\"\u003ePower input terminals (L \/ N)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1603\" data-end=\"1663\"\u003e\u003cstrong data-start=\"1605\" data-end=\"1661\"\u003eMeasurement terminals (direct connection up to 100A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1664\" data-end=\"1705\"\u003e\u003cstrong data-start=\"1666\" data-end=\"1703\"\u003eRS485 terminals for communication\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1707\" data-end=\"1710\"\u003e\n\u003ch2 data-start=\"1712\" data-end=\"1732\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1734\" data-end=\"1907\"\u003e\n\u003cli data-start=\"1734\" data-end=\"1781\"\u003eMounting on \u003cstrong data-start=\"1748\" data-end=\"1779\"\u003eDIN rail (electrical panel)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1782\" data-end=\"1836\"\u003eDirect wiring (no external CT required up to 100A)\u003c\/li\u003e\n\u003cli data-start=\"1837\" data-end=\"1907\"\u003eSuitable for integration in \u003cstrong data-start=\"1867\" data-end=\"1905\"\u003edistribution boards and PV systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1909\" data-end=\"1912\"\u003e\n\u003ch2 data-start=\"1914\" data-end=\"1934\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1936\" data-end=\"1946\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1948\" data-end=\"2177\"\u003e✔ Photovoltaic systems (inverter monitoring \u0026amp; export control)\u003cbr data-start=\"2009\" data-end=\"2012\"\u003e✔ Energy consumption monitoring\u003cbr data-start=\"2043\" data-end=\"2046\"\u003e✔ Smart home and energy management systems\u003cbr data-start=\"2088\" data-end=\"2091\"\u003e✔ Industrial and commercial electrical panels\u003cbr data-start=\"2136\" data-end=\"2139\"\u003e✔ Grid interaction and load analysis\u003c\/p\u003e\n\u003chr data-start=\"2179\" data-end=\"2182\"\u003e\n\u003ch2 data-start=\"2184\" data-end=\"2201\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cul data-start=\"2203\" data-end=\"2312\"\u003e\n\u003cli data-start=\"2203\" data-end=\"2219\"\u003eUsed product\u003c\/li\u003e\n\u003cli data-start=\"2220\" data-end=\"2252\"\u003eCondition as shown in images\u003c\/li\u003e\n\u003cli data-start=\"2253\" data-end=\"2312\"\u003eFunctional verification recommended before installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2314\" data-end=\"2317\"\u003e\n\u003ch2 data-start=\"2319\" data-end=\"2345\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2347\" data-end=\"2531\"\u003eThe \u003cstrong data-start=\"2351\" data-end=\"2370\"\u003eCHINT DDSU666-H\u003c\/strong\u003e is a reliable and widely used \u003cstrong data-start=\"2401\" data-end=\"2423\"\u003esmart energy meter\u003c\/strong\u003e for \u003cstrong data-start=\"2428\" data-end=\"2452\"\u003esingle-phase systems\u003c\/strong\u003e, featuring \u003cstrong data-start=\"2464\" data-end=\"2528\"\u003eRS485 Modbus communication and direct measurement up to 100A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2533\" data-end=\"2702\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eIt is an excellent solution for \u003cstrong data-start=\"2565\" data-end=\"2641\"\u003ephotovoltaic monitoring, energy management, and smart electrical systems\u003c\/strong\u003e, combining accuracy, simplicity, and industrial reliability.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53643043995981,"sku":null,"price":70.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5234.jpg?v=1775121959"},{"product_id":"ms-gsm-industrial-communication-module-gsm-gprs-remote-control-interface-din-rail-sim-slot-usb-external-antenna","title":"MS-GSM Industrial Communication Module – GSM\/GPRS Remote Control Interface | DIN Rail | SIM Slot | USB | External Antenna","description":"\u003cp data-start=\"197\" data-end=\"497\"\u003eThe \u003cstrong data-start=\"201\" data-end=\"243\"\u003eMS-GSM industrial communication module\u003c\/strong\u003e is a compact and reliable device designed for \u003cstrong data-start=\"290\" data-end=\"345\"\u003eremote monitoring and control via GSM\/GPRS networks\u003c\/strong\u003e. It is ideal for \u003cstrong data-start=\"363\" data-end=\"436\"\u003eindustrial automation, photovoltaic systems, and remote installations\u003c\/strong\u003e where wired internet or Wi-Fi connectivity is not available.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"719\"\u003eDesigned for \u003cstrong data-start=\"512\" data-end=\"533\"\u003eDIN rail mounting\u003c\/strong\u003e, the module integrates multiple interfaces and allows \u003cstrong data-start=\"588\" data-end=\"658\"\u003edata transmission, SMS communication, and remote command execution\u003c\/strong\u003e, making it a versatile solution for industrial environments.\u003c\/p\u003e\n\u003chr data-start=\"721\" data-end=\"724\"\u003e\n\u003ch2 data-start=\"726\" data-end=\"748\"\u003e📡 Main Functions\u003c\/h2\u003e\n\u003cul data-start=\"750\" data-end=\"966\"\u003e\n\u003cli data-start=\"750\" data-end=\"805\"\u003eGSM\/GPRS communication for remote data transmission\u003c\/li\u003e\n\u003cli data-start=\"806\" data-end=\"854\"\u003eSMS sending\/receiving for alerts and control\u003c\/li\u003e\n\u003cli data-start=\"855\" data-end=\"915\"\u003eRemote monitoring of industrial and photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"916\" data-end=\"966\"\u003eTelecontrol of equipment and automated systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"968\" data-end=\"971\"\u003e\n\u003ch2 data-start=\"973\" data-end=\"1005\"\u003e🔌 Interfaces \u0026amp; Connections\u003c\/h2\u003e\n\u003cul data-start=\"1007\" data-end=\"1246\"\u003e\n\u003cli data-start=\"1007\" data-end=\"1041\"\u003e\n\u003cstrong data-start=\"1009\" data-end=\"1026\"\u003eSIM card slot\u003c\/strong\u003e (integrated)\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1092\"\u003e\n\u003cstrong data-start=\"1044\" data-end=\"1056\"\u003eUSB port\u003c\/strong\u003e for configuration and programming\u003c\/li\u003e\n\u003cli data-start=\"1093\" data-end=\"1137\"\u003e\u003cstrong data-start=\"1095\" data-end=\"1135\"\u003eExternal GSM antenna connector (ANT)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1138\" data-end=\"1246\"\u003e\n\u003cstrong data-start=\"1140\" data-end=\"1170\"\u003eScrew terminal block (1–9)\u003c\/strong\u003e for:\n\u003cul data-start=\"1180\" data-end=\"1246\"\u003e\n\u003cli data-start=\"1180\" data-end=\"1205\"\u003eDigital\/analog inputs\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1227\"\u003eControl outputs\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1246\"\u003ePower supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1248\" data-end=\"1251\"\u003e\n\u003ch2 data-start=\"1253\" data-end=\"1279\"\u003e⚙️ Technical Features\u003c\/h2\u003e\n\u003cul data-start=\"1281\" data-end=\"1530\"\u003e\n\u003cli data-start=\"1281\" data-end=\"1326\"\u003e\n\u003cstrong data-start=\"1283\" data-end=\"1304\"\u003eDIN rail mounting\u003c\/strong\u003e (electrical panels)\u003c\/li\u003e\n\u003cli data-start=\"1327\" data-end=\"1386\"\u003eFront \u003cstrong data-start=\"1335\" data-end=\"1370\"\u003edisplay with navigation buttons\u003c\/strong\u003e (OK \/ arrows)\u003c\/li\u003e\n\u003cli data-start=\"1387\" data-end=\"1429\"\u003eLocal configuration via user interface\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1489\"\u003e\n\u003cstrong data-start=\"1432\" data-end=\"1457\"\u003eLED status indicators\u003c\/strong\u003e for diagnostics and operation\u003c\/li\u003e\n\u003cli data-start=\"1490\" data-end=\"1530\"\u003eCompact and robust industrial design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1532\" data-end=\"1535\"\u003e\n\u003ch2 data-start=\"1537\" data-end=\"1557\"\u003e🛠 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1559\" data-end=\"1569\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1571\" data-end=\"1733\"\u003e✔ Photovoltaic systems (inverter monitoring)\u003cbr data-start=\"1615\" data-end=\"1618\"\u003e✔ Industrial automation\u003cbr data-start=\"1641\" data-end=\"1644\"\u003e✔ Alarm and security systems\u003cbr data-start=\"1672\" data-end=\"1675\"\u003e✔ Remote machinery control\u003cbr data-start=\"1701\" data-end=\"1704\"\u003e✔ Energy management systems\u003c\/p\u003e\n\u003chr data-start=\"1735\" data-end=\"1738\"\u003e\n\u003ch2 data-start=\"1740\" data-end=\"1758\"\u003e📦 Advantages\u003c\/h2\u003e\n\u003cp data-start=\"1760\" data-end=\"1989\"\u003e✔ Operates independently from wired internet networks\u003cbr data-start=\"1813\" data-end=\"1816\"\u003e✔ Quick and easy installation\u003cbr data-start=\"1845\" data-end=\"1848\"\u003e✔ Reliable performance in industrial environments\u003cbr data-start=\"1897\" data-end=\"1900\"\u003e✔ Perfect for \u003cstrong data-start=\"1914\" data-end=\"1939\"\u003eretrofit applications\u003c\/strong\u003e\u003cbr data-start=\"1939\" data-end=\"1942\"\u003e✔ Enables remote access in isolated locations\u003c\/p\u003e\n\u003chr data-start=\"1991\" data-end=\"1994\"\u003e\n\u003ch2 data-start=\"1996\" data-end=\"2022\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2024\" data-end=\"2367\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"2028\" data-end=\"2045\"\u003eMS-GSM module\u003c\/strong\u003e is a practical and efficient solution for \u003cstrong data-start=\"2088\" data-end=\"2138\"\u003eremote monitoring and control via GSM networks\u003c\/strong\u003e. With \u003cstrong data-start=\"2145\" data-end=\"2225\"\u003eDIN rail installation, SIM-based communication, and versatile I\/O interfaces\u003c\/strong\u003e, it is ideal for industrial and energy systems requiring reliable remote connectivity without relying on traditional internet infrastructure.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53643077288269,"sku":null,"price":200.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5229_0009bcbf-6498-4d5f-b76e-cc3962e6b8f4.jpg?v=1775121515"},{"product_id":"sfera-c35qsl080-mid-single-phase-energy-meter-230v-80a-lcd-display-din-rail-mid-certified-ac1n500034","title":"SFERA C35QSL080 MID – Single-Phase Energy Meter | 230V | 80A | LCD Display | DIN Rail | MID Certified | AC1N500034","description":"\u003ch2 data-start=\"0\" data-end=\"23\"\u003e🔧 Technical Title\u003c\/h2\u003e\n\u003cp data-start=\"25\" data-end=\"143\"\u003e\u003cstrong data-start=\"25\" data-end=\"143\"\u003eSFERA C35QSL080 MID – Single-Phase Energy Meter | 230V | 80A | LCD Display | DIN Rail | MID Certified | AC1N500034\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"145\" data-end=\"148\"\u003e\n\u003ch2 data-start=\"150\" data-end=\"188\"\u003e📘 Detailed Technical Description\u003c\/h2\u003e\n\u003cp data-start=\"190\" data-end=\"379\"\u003eThe \u003cstrong data-start=\"194\" data-end=\"217\"\u003eSFERA C35QSL080 MID\u003c\/strong\u003e is a \u003cstrong data-start=\"223\" data-end=\"263\"\u003esingle-phase electronic energy meter\u003c\/strong\u003e designed for \u003cstrong data-start=\"277\" data-end=\"320\"\u003eaccurate energy consumption measurement\u003c\/strong\u003e in residential, commercial, and industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"381\" data-end=\"570\"\u003eThanks to its \u003cstrong data-start=\"395\" data-end=\"450\"\u003eMID certification (Measuring Instruments Directive)\u003c\/strong\u003e, it is suitable for \u003cstrong data-start=\"471\" data-end=\"515\"\u003elegal energy billing and fiscal metering\u003c\/strong\u003e, making it ideal for sub-metering and cost allocation.\u003c\/p\u003e\n\u003cp data-start=\"572\" data-end=\"755\"\u003eIts \u003cstrong data-start=\"576\" data-end=\"603\"\u003ecompact DIN rail format\u003c\/strong\u003e ensures easy installation in electrical panels, while the \u003cstrong data-start=\"662\" data-end=\"694\"\u003eLCD display and pulse output\u003c\/strong\u003e enable both local reading and remote monitoring integration.\u003c\/p\u003e\n\u003chr data-start=\"757\" data-end=\"760\"\u003e\n\u003ch2 data-start=\"762\" data-end=\"796\"\u003e⚙️ Electrical Characteristics\u003c\/h2\u003e\n\u003cul data-start=\"798\" data-end=\"1004\"\u003e\n\u003cli data-start=\"798\" data-end=\"837\"\u003e\n\u003cstrong data-start=\"800\" data-end=\"820\"\u003eNominal voltage:\u003c\/strong\u003e 230 – 240 V AC\u003c\/li\u003e\n\u003cli data-start=\"838\" data-end=\"867\"\u003e\n\u003cstrong data-start=\"840\" data-end=\"854\"\u003eFrequency:\u003c\/strong\u003e 50 \/ 60 Hz\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"927\"\u003e\n\u003cstrong data-start=\"870\" data-end=\"890\"\u003eMaximum current:\u003c\/strong\u003e up to \u003cstrong data-start=\"897\" data-end=\"925\"\u003e80 A (direct connection)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"928\" data-end=\"965\"\u003e\n\u003cstrong data-start=\"930\" data-end=\"949\"\u003eAccuracy class:\u003c\/strong\u003e MID compliant\u003c\/li\u003e\n\u003cli data-start=\"966\" data-end=\"1004\"\u003e\n\u003cstrong data-start=\"968\" data-end=\"985\"\u003ePulse output:\u003c\/strong\u003e \u003cstrong data-start=\"986\" data-end=\"1002\"\u003e1000 imp\/kWh\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1006\" data-end=\"1009\"\u003e\n\u003ch2 data-start=\"1011\" data-end=\"1040\"\u003e📊 Measurement Functions\u003c\/h2\u003e\n\u003cul data-start=\"1042\" data-end=\"1192\"\u003e\n\u003cli data-start=\"1042\" data-end=\"1081\"\u003eActive energy measurement (\u003cstrong data-start=\"1071\" data-end=\"1078\"\u003ekWh\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1082\" data-end=\"1118\"\u003eReal-time consumption monitoring\u003c\/li\u003e\n\u003cli data-start=\"1119\" data-end=\"1148\"\u003eLCD display visualization\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1192\"\u003ePulse output for remote reading systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1194\" data-end=\"1197\"\u003e\n\u003ch2 data-start=\"1199\" data-end=\"1233\"\u003e🔌 Connections \u0026amp; Installation\u003c\/h2\u003e\n\u003cul data-start=\"1235\" data-end=\"1421\"\u003e\n\u003cli data-start=\"1235\" data-end=\"1304\"\u003e\n\u003cstrong data-start=\"1237\" data-end=\"1258\"\u003eDirect connection\u003c\/strong\u003e (no current transformer required up to 80A)\u003c\/li\u003e\n\u003cli data-start=\"1305\" data-end=\"1370\"\u003eScrew terminals for:\n\u003cul data-start=\"1332\" data-end=\"1370\"\u003e\n\u003cli data-start=\"1332\" data-end=\"1348\"\u003e\u003cstrong data-start=\"1334\" data-end=\"1346\"\u003eLine (L)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1351\" data-end=\"1370\"\u003e\u003cstrong data-start=\"1353\" data-end=\"1368\"\u003eNeutral (N)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1371\" data-end=\"1421\"\u003e\n\u003cstrong data-start=\"1373\" data-end=\"1394\"\u003eDIN rail mounting\u003c\/strong\u003e (compact modular design)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1423\" data-end=\"1426\"\u003e\n\u003ch2 data-start=\"1428\" data-end=\"1453\"\u003e⚙️ Build \u0026amp; Interface\u003c\/h2\u003e\n\u003cul data-start=\"1455\" data-end=\"1614\"\u003e\n\u003cli data-start=\"1455\" data-end=\"1500\"\u003eFront \u003cstrong data-start=\"1463\" data-end=\"1478\"\u003eLCD display\u003c\/strong\u003e for energy readings\u003c\/li\u003e\n\u003cli data-start=\"1501\" data-end=\"1542\"\u003e\n\u003cstrong data-start=\"1503\" data-end=\"1524\"\u003eNavigation button\u003c\/strong\u003e for menu access\u003c\/li\u003e\n\u003cli data-start=\"1543\" data-end=\"1570\"\u003e\u003cstrong data-start=\"1545\" data-end=\"1568\"\u003eLED pulse indicator\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1614\"\u003eRobust housing for continuous operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1616\" data-end=\"1619\"\u003e\n\u003ch2 data-start=\"1621\" data-end=\"1656\"\u003e🛡 Certifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul data-start=\"1658\" data-end=\"1794\"\u003e\n\u003cli data-start=\"1658\" data-end=\"1713\"\u003e\n\u003cstrong data-start=\"1660\" data-end=\"1677\"\u003eMID certified\u003c\/strong\u003e (Measuring Instruments Directive)\u003c\/li\u003e\n\u003cli data-start=\"1714\" data-end=\"1732\"\u003e\u003cstrong data-start=\"1716\" data-end=\"1730\"\u003eCE marking\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1733\" data-end=\"1794\"\u003eSuitable for \u003cstrong data-start=\"1748\" data-end=\"1792\"\u003efiscal metering and billing applications\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1796\" data-end=\"1799\"\u003e\n\u003ch2 data-start=\"1801\" data-end=\"1821\"\u003e🛠 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1823\" data-end=\"1833\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1835\" data-end=\"2048\"\u003e✔ Energy consumption billing and sub-metering\u003cbr data-start=\"1880\" data-end=\"1883\"\u003e✔ Residential electrical installations\u003cbr data-start=\"1921\" data-end=\"1924\"\u003e✔ Commercial and industrial systems\u003cbr data-start=\"1959\" data-end=\"1962\"\u003e✔ Energy cost allocation (multi-tenant buildings)\u003cbr data-start=\"2011\" data-end=\"2014\"\u003e✔ Electrical distribution panels\u003c\/p\u003e\n\u003chr data-start=\"2050\" data-end=\"2053\"\u003e\n\u003ch2 data-start=\"2055\" data-end=\"2085\"\u003e📦 Product Identification\u003c\/h2\u003e\n\u003cul data-start=\"2087\" data-end=\"2201\"\u003e\n\u003cli data-start=\"2087\" data-end=\"2107\"\u003e\n\u003cstrong data-start=\"2089\" data-end=\"2099\"\u003eBrand:\u003c\/strong\u003e SFERA\u003c\/li\u003e\n\u003cli data-start=\"2108\" data-end=\"2132\"\u003e\n\u003cstrong data-start=\"2110\" data-end=\"2120\"\u003eModel:\u003c\/strong\u003e C35QSL080\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2157\"\u003e\n\u003cstrong data-start=\"2135\" data-end=\"2144\"\u003eCode:\u003c\/strong\u003e AC1N500034\u003c\/li\u003e\n\u003cli data-start=\"2158\" data-end=\"2201\"\u003e\n\u003cstrong data-start=\"2160\" data-end=\"2169\"\u003eType:\u003c\/strong\u003e Single-phase MID energy meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2203\" data-end=\"2206\"\u003e\n\u003ch2 data-start=\"2208\" data-end=\"2234\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2236\" data-end=\"2555\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"2240\" data-end=\"2263\"\u003eSFERA C35QSL080 MID\u003c\/strong\u003e is a reliable and accurate \u003cstrong data-start=\"2291\" data-end=\"2320\"\u003esingle-phase energy meter\u003c\/strong\u003e designed for \u003cstrong data-start=\"2334\" data-end=\"2381\"\u003eprofessional energy measurement and billing\u003c\/strong\u003e. With \u003cstrong data-start=\"2388\" data-end=\"2460\"\u003eMID certification, direct 80A measurement, and DIN rail installation\u003c\/strong\u003e, it is an ideal solution for \u003cstrong data-start=\"2490\" data-end=\"2554\"\u003esub-metering, energy monitoring, and cost allocation systems\u003c\/strong\u003e.\u003c\/p\u003e","brand":"SFERA","offers":[{"title":"Default Title","offer_id":53643103240525,"sku":null,"price":70.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5239.jpg?v=1775129485"},{"product_id":"tecsystem-nt935-temperature-control-unit-protection-relay-4-channels-pt100-inputs-digital-display-alarm-trip-fan-outputs","title":"Tecsystem NT935 – Temperature Control Unit \u0026 Protection Relay – 4 Channels – PT100 Inputs – Digital Display – Alarm\/Trip\/Fan Outputs","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"d5ec3417-329f-423a-8232-3357f6d8f765\" data-testid=\"conversation-turn-144\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"d5ec3417-329f-423a-8232-3357f6d8f765\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"64myfg\" data-start=\"0\" data-end=\"23\"\u003e🔧 Technical Title\u003c\/h2\u003e\n\u003cp data-start=\"25\" data-end=\"161\"\u003e\u003cstrong data-start=\"25\" data-end=\"161\"\u003eTecsystem NT935 – Temperature Control Unit \u0026amp; Protection Relay – 4 Channels – PT100 Inputs – Digital Display – Alarm\/Trip\/Fan Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"163\" data-end=\"166\"\u003e\n\u003ch2 data-section-id=\"n9lll1\" data-start=\"168\" data-end=\"206\"\u003e📘 Detailed Technical Description\u003c\/h2\u003e\n\u003cp data-start=\"208\" data-end=\"404\"\u003eThe \u003cstrong data-start=\"212\" data-end=\"231\"\u003eTecsystem NT935\u003c\/strong\u003e is an advanced \u003cstrong data-start=\"247\" data-end=\"304\"\u003eelectronic temperature monitoring and protection unit\u003c\/strong\u003e, designed for continuous thermal supervision of \u003cstrong data-start=\"353\" data-end=\"403\"\u003etransformers, motors, and industrial equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"406\" data-end=\"644\"\u003eEquipped with a \u003cstrong data-start=\"422\" data-end=\"475\"\u003edigital display and 4 independent sensor channels\u003c\/strong\u003e, it enables precise temperature control via \u003cstrong data-start=\"520\" data-end=\"536\"\u003ePT100 probes\u003c\/strong\u003e, activating \u003cstrong data-start=\"549\" data-end=\"588\"\u003ealarm, ventilation, and trip relays\u003c\/strong\u003e to ensure system safety and prevent overheating damage.\u003c\/p\u003e\n\u003cp data-start=\"646\" data-end=\"767\"\u003eIts reliability and industrial-grade design make it a key component in \u003cstrong data-start=\"717\" data-end=\"766\"\u003epreventive maintenance and protection systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"769\" data-end=\"772\"\u003e\n\u003ch2 data-section-id=\"15jsqn0\" data-start=\"774\" data-end=\"802\"\u003e⚡ Input Characteristics\u003c\/h2\u003e\n\u003cul data-start=\"804\" data-end=\"946\"\u003e\n\u003cli data-section-id=\"1iiqlhn\" data-start=\"804\" data-end=\"845\"\u003e\n\u003cstrong data-start=\"806\" data-end=\"829\"\u003eNumber of channels:\u003c\/strong\u003e 4 (CH1 – CH4)\u003c\/li\u003e\n\u003cli data-section-id=\"1sm2h1l\" data-start=\"846\" data-end=\"872\"\u003e\n\u003cstrong data-start=\"848\" data-end=\"864\"\u003eSensor type:\u003c\/strong\u003e PT100\u003c\/li\u003e\n\u003cli data-section-id=\"1g3o2el\" data-start=\"873\" data-end=\"946\"\u003e\n\u003cstrong data-start=\"875\" data-end=\"896\"\u003eMeasurement mode:\u003c\/strong\u003e\n\u003cul data-start=\"901\" data-end=\"946\"\u003e\n\u003cli data-section-id=\"ox486c\" data-start=\"901\" data-end=\"923\"\u003eAutomatic scanning\u003c\/li\u003e\n\u003cli data-section-id=\"bz752q\" data-start=\"926\" data-end=\"946\"\u003eManual selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-section-id=\"1joljnp\" data-start=\"953\" data-end=\"978\"\u003e🔋 Control Functions\u003c\/h2\u003e\n\u003cul data-start=\"980\" data-end=\"1245\"\u003e\n\u003cli data-section-id=\"riizqm\" data-start=\"980\" data-end=\"1022\"\u003eReal-time \u003cstrong data-start=\"992\" data-end=\"1020\"\u003etemperature display (°C)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1i5o501\" data-start=\"1023\" data-end=\"1060\"\u003eProgrammable \u003cstrong data-start=\"1038\" data-end=\"1058\"\u003eT.MAX thresholds\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b9xzyj\" data-start=\"1061\" data-end=\"1116\"\u003eOperating modes:\u003cbr data-start=\"1079\" data-end=\"1082\"\u003e✔ AUTO\u003cbr data-start=\"1090\" data-end=\"1093\"\u003e✔ MANUAL\u003cbr data-start=\"1103\" data-end=\"1106\"\u003e✔ SCAN\u003c\/li\u003e\n\u003cli data-section-id=\"15dztny\" data-start=\"1118\" data-end=\"1245\"\u003eOutput control:\u003cbr data-start=\"1135\" data-end=\"1138\"\u003e✔ \u003cstrong data-start=\"1142\" data-end=\"1149\"\u003eFAN\u003c\/strong\u003e (cooling system activation)\u003cbr data-start=\"1177\" data-end=\"1180\"\u003e✔ \u003cstrong data-start=\"1184\" data-end=\"1193\"\u003eALARM\u003c\/strong\u003e (warning signal)\u003cbr data-start=\"1210\" data-end=\"1213\"\u003e✔ \u003cstrong data-start=\"1217\" data-end=\"1225\"\u003eTRIP\u003c\/strong\u003e (safety shutdown)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1247\" data-end=\"1250\"\u003e\n\u003ch2 data-section-id=\"1io3nkf\" data-start=\"1252\" data-end=\"1280\"\u003e🛡️ Protection \u0026amp; Safety\u003c\/h2\u003e\n\u003cul data-start=\"1282\" data-end=\"1451\"\u003e\n\u003cli data-section-id=\"18tkvkg\" data-start=\"1282\" data-end=\"1320\"\u003e\u003cstrong data-start=\"1284\" data-end=\"1318\"\u003eSensor fault detection (FAULT)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1n2rasi\" data-start=\"1321\" data-end=\"1354\"\u003eContinuous thermal monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"2opuzp\" data-start=\"1355\" data-end=\"1403\"\u003ePreventive protection for critical equipment\u003c\/li\u003e\n\u003cli data-section-id=\"rehz74\" data-start=\"1404\" data-end=\"1451\"\u003eHigh reliability in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1453\" data-end=\"1456\"\u003e\n\u003ch2 data-section-id=\"1oxsdih\" data-start=\"1458\" data-end=\"1487\"\u003e⚙️ Construction Features\u003c\/h2\u003e\n\u003cul data-start=\"1489\" data-end=\"1691\"\u003e\n\u003cli data-section-id=\"enyjrs\" data-start=\"1489\" data-end=\"1509\"\u003e\n\u003cstrong data-start=\"1491\" data-end=\"1501\"\u003eModel:\u003c\/strong\u003e NT935\u003c\/li\u003e\n\u003cli data-section-id=\"12vsedt\" data-start=\"1510\" data-end=\"1548\"\u003e\n\u003cstrong data-start=\"1512\" data-end=\"1529\"\u003eManufacturer:\u003c\/strong\u003e Tecsystem S.r.l.\u003c\/li\u003e\n\u003cli data-section-id=\"2sbmbo\" data-start=\"1549\" data-end=\"1582\"\u003e\u003cstrong data-start=\"1551\" data-end=\"1580\"\u003eFront digital LED display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1gcl9fq\" data-start=\"1583\" data-end=\"1648\"\u003eProgramming keypad:\n\u003cul data-start=\"1609\" data-end=\"1648\"\u003e\n\u003cli data-section-id=\"175jodp\" data-start=\"1609\" data-end=\"1616\"\u003ePRG\u003c\/li\u003e\n\u003cli data-section-id=\"170p4s7\" data-start=\"1619\" data-end=\"1626\"\u003eENT\u003c\/li\u003e\n\u003cli data-section-id=\"69bfz2\" data-start=\"1629\" data-end=\"1637\"\u003eTEST\u003c\/li\u003e\n\u003cli data-section-id=\"1t5rgsr\" data-start=\"1640\" data-end=\"1648\"\u003eMODE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1e2yp7w\" data-start=\"1650\" data-end=\"1691\"\u003eCompact design for panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1693\" data-end=\"1696\"\u003e\n\u003ch2 data-section-id=\"5g4drl\" data-start=\"1698\" data-end=\"1717\"\u003e🔌 Connections\u003c\/h2\u003e\n\u003cul data-start=\"1719\" data-end=\"1915\"\u003e\n\u003cli data-section-id=\"gb0gkw\" data-start=\"1719\" data-end=\"1758\"\u003e\n\u003cstrong data-start=\"1721\" data-end=\"1732\"\u003eInputs:\u003c\/strong\u003e 4 PT100 sensor channels\u003c\/li\u003e\n\u003cli data-section-id=\"lkf2j1\" data-start=\"1759\" data-end=\"1828\"\u003e\n\u003cstrong data-start=\"1761\" data-end=\"1773\"\u003eOutputs:\u003c\/strong\u003e relay contacts for:\n\u003cul data-start=\"1798\" data-end=\"1828\"\u003e\n\u003cli data-section-id=\"61suon\" data-start=\"1798\" data-end=\"1806\"\u003eTRIP\u003c\/li\u003e\n\u003cli data-section-id=\"pc7xbv\" data-start=\"1809\" data-end=\"1818\"\u003eALARM\u003c\/li\u003e\n\u003cli data-section-id=\"171j729\" data-start=\"1821\" data-end=\"1828\"\u003eFAN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"sd5j5k\" data-start=\"1830\" data-end=\"1869\"\u003e\n\u003cstrong data-start=\"1832\" data-end=\"1850\"\u003eCommunication:\u003c\/strong\u003e RS OUT interface\u003c\/li\u003e\n\u003cli data-section-id=\"iik1gt\" data-start=\"1870\" data-end=\"1915\"\u003eClearly labeled terminals for easy wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1917\" data-end=\"1920\"\u003e\n\u003ch2 data-section-id=\"khwi0t\" data-start=\"1922\" data-end=\"1942\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1944\" data-end=\"1956\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1958\" data-end=\"2099\"\u003e✔ Power transformers\u003cbr data-start=\"1978\" data-end=\"1981\"\u003e✔ Industrial motors\u003cbr data-start=\"2000\" data-end=\"2003\"\u003e✔ Generators\u003cbr data-start=\"2015\" data-end=\"2018\"\u003e✔ Electrical panels\u003cbr data-start=\"2037\" data-end=\"2040\"\u003e✔ Automation systems\u003cbr data-start=\"2060\" data-end=\"2063\"\u003e✔ Thermal monitoring installations\u003c\/p\u003e\n\u003chr data-start=\"2101\" data-end=\"2104\"\u003e\n\u003ch2 data-section-id=\"1c4vc31\" data-start=\"2106\" data-end=\"2123\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2125\" data-end=\"2215\"\u003eUsed product, condition as shown.\u003cbr data-start=\"2158\" data-end=\"2161\"\u003eFunctional testing is recommended before installation.\u003c\/p\u003e\n\u003chr data-start=\"2217\" data-end=\"2220\"\u003e\n\u003ch2 data-section-id=\"1yc8hbc\" data-start=\"2222\" data-end=\"2248\"\u003e🚀 Commercial Summary\u003c\/h2\u003e\n\u003cp data-start=\"2250\" data-end=\"2445\"\u003eThe \u003cstrong data-start=\"2254\" data-end=\"2273\"\u003eTecsystem NT935\u003c\/strong\u003e is a professional \u003cstrong data-start=\"2292\" data-end=\"2334\"\u003e4-channel temperature monitoring relay\u003c\/strong\u003e, designed to protect critical equipment through \u003cstrong data-start=\"2383\" data-end=\"2442\"\u003econtinuous thermal control and automatic safety actions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2447\" data-end=\"2633\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eWith \u003cstrong data-start=\"2452\" data-end=\"2538\"\u003ePT100 compatibility, programmable thresholds, and relay outputs for alarm and trip\u003c\/strong\u003e, it is an essential solution for \u003cstrong data-start=\"2572\" data-end=\"2632\"\u003eindustrial protection and preventive maintenance systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53674226614605,"sku":null,"price":290.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5310.jpg?v=1775553204"},{"product_id":"fronius-ig-ig-plus-lcd-display-module-user-interface-board-with-keypad-and-flat-cable-pv-inverter-hmi","title":"Fronius IG \/ IG Plus LCD Display Module – User Interface Board with Keypad and Flat Cable – PV Inverter HMI","description":"\u003cp data-start=\"228\" data-end=\"413\"\u003eOriginal \u003cstrong data-start=\"237\" data-end=\"267\"\u003eFronius LCD display module\u003c\/strong\u003e complete with electronic board and integrated keypad, designed as a \u003cstrong data-start=\"336\" data-end=\"360\"\u003euser interface (HMI)\u003c\/strong\u003e for \u003cstrong data-start=\"365\" data-end=\"412\"\u003eFronius IG \/ IG Plus photovoltaic inverters\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"415\" data-end=\"724\"\u003eThis module enables the visualization and management of key inverter parameters, including energy production, operating status, system configuration, and diagnostics. The display features integrated navigation buttons and connects via flat cable, ensuring direct communication with the inverter control board.\u003c\/p\u003e\n\u003chr data-start=\"726\" data-end=\"729\"\u003e\n\u003ch3 data-start=\"731\" data-end=\"762\"\u003e⚙️ Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"763\" data-end=\"988\"\u003e\n\u003cli data-start=\"763\" data-end=\"821\"\u003eType: \u003cstrong data-start=\"771\" data-end=\"819\"\u003eLCD display module with user interface (HMI)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"822\" data-end=\"875\"\u003eCompatibility: \u003cstrong data-start=\"839\" data-end=\"873\"\u003eFronius IG \/ IG Plus inverters\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"876\" data-end=\"907\"\u003eDisplay: \u003cstrong data-start=\"887\" data-end=\"905\"\u003eMonochrome LCD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"908\" data-end=\"946\"\u003eControls: \u003cstrong data-start=\"920\" data-end=\"944\"\u003e4 integrated buttons\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"947\" data-end=\"988\"\u003eConnection: \u003cstrong data-start=\"961\" data-end=\"986\"\u003eFlat cable (included)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"990\" data-end=\"1004\"\u003e\u003cstrong data-start=\"990\" data-end=\"1004\"\u003eFunctions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1005\" data-end=\"1235\"\u003e\n\u003cli data-start=\"1005\" data-end=\"1054\"\u003eDisplay of production data (day, year, total)\u003c\/li\u003e\n\u003cli data-start=\"1055\" data-end=\"1085\"\u003eInverter status and alarms\u003c\/li\u003e\n\u003cli data-start=\"1086\" data-end=\"1118\"\u003eConfiguration and setup menu\u003c\/li\u003e\n\u003cli data-start=\"1120\" data-end=\"1177\"\u003ePCB: electronic board with integrated microcontroller\u003c\/li\u003e\n\u003cli data-start=\"1178\" data-end=\"1235\"\u003eInstallation: \u003cstrong data-start=\"1194\" data-end=\"1233\"\u003ePlug \u0026amp; play on compatible inverters\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1237\" data-end=\"1240\"\u003e\n\u003ch3 data-start=\"1242\" data-end=\"1263\"\u003e🔧 Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"1264\" data-end=\"1492\"\u003e\n\u003cli data-start=\"1264\" data-end=\"1311\"\u003eReal-time monitoring of photovoltaic system\u003c\/li\u003e\n\u003cli data-start=\"1312\" data-end=\"1354\"\u003eAccess to inverter configuration menus\u003c\/li\u003e\n\u003cli data-start=\"1355\" data-end=\"1415\"\u003eDisplay of energy parameters (\u003cstrong data-start=\"1387\" data-end=\"1412\"\u003eNow, Day, Year, Total\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1416\" data-end=\"1452\"\u003eDiagnostics and error indication\u003c\/li\u003e\n\u003cli data-start=\"1453\" data-end=\"1492\"\u003eSimple and intuitive user interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1494\" data-end=\"1497\"\u003e\n\u003ch3 data-start=\"1499\" data-end=\"1518\"\u003e🔌 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1519\" data-end=\"1683\"\u003e\n\u003cli data-start=\"1519\" data-end=\"1566\"\u003eFronius IG \/ IG Plus photovoltaic inverters\u003c\/li\u003e\n\u003cli data-start=\"1567\" data-end=\"1602\"\u003eInverter repair and maintenance\u003c\/li\u003e\n\u003cli data-start=\"1603\" data-end=\"1653\"\u003eReplacement of faulty or damaged display units\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1683\"\u003eSpare part for PV systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1685\" data-end=\"1688\"\u003e\n\u003ch3 data-start=\"1690\" data-end=\"1713\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"1714\" data-end=\"1783\"\u003e\n\u003cli data-start=\"1714\" data-end=\"1750\"\u003e1× \u003cstrong data-start=\"1719\" data-end=\"1748\"\u003eFronius LCD display board\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1751\" data-end=\"1783\"\u003e1× \u003cstrong data-start=\"1756\" data-end=\"1781\"\u003eFlat connection cable\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1785\" data-end=\"1788\"\u003e\n\u003ch3 data-start=\"1790\" data-end=\"1807\"\u003e💡 Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1808\" data-end=\"1991\"\u003e✔ Original spare part for Fronius inverters\u003cbr data-start=\"1851\" data-end=\"1854\"\u003e✔ Quick and easy installation\u003cbr data-start=\"1883\" data-end=\"1886\"\u003e✔ Full restoration of data visualization\u003cbr data-start=\"1926\" data-end=\"1929\"\u003e✔ Suitable for professional maintenance\u003cbr data-start=\"1968\" data-end=\"1971\"\u003e✔ High reliability\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53714162581837,"sku":null,"price":40.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5402.jpg?v=1776181804"},{"product_id":"fronius-ig-ig-plus-lcd-display-module-with-cover-and-keypad-complete-hmi-interface-with-flat-cable","title":"Fronius IG \/ IG Plus LCD Display Module with Cover and Keypad – Complete HMI Interface with Flat Cable","description":"\u003cp data-start=\"223\" data-end=\"431\"\u003eOriginal \u003cstrong data-start=\"232\" data-end=\"262\"\u003eFronius LCD display module\u003c\/strong\u003e complete with \u003cstrong data-start=\"277\" data-end=\"338\"\u003eprotective front cover, integrated keypad, and flat cable\u003c\/strong\u003e, designed as a \u003cstrong data-start=\"354\" data-end=\"378\"\u003euser interface (HMI)\u003c\/strong\u003e for \u003cstrong data-start=\"383\" data-end=\"430\"\u003eFronius IG \/ IG Plus photovoltaic inverters\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"433\" data-end=\"638\"\u003eThis version includes the \u003cstrong data-start=\"459\" data-end=\"508\"\u003etransparent front panel with membrane buttons\u003c\/strong\u003e, providing mechanical protection and ease of use. It is ideal for direct replacement of damaged or non-functioning display units.\u003c\/p\u003e\n\u003cp data-start=\"640\" data-end=\"824\"\u003eThe display allows immediate visualization of key system data, including real-time production, daily, yearly, and total energy, as well as access to configuration and diagnostic menus.\u003c\/p\u003e\n\u003chr data-start=\"826\" data-end=\"829\"\u003e\n\u003ch3 data-start=\"831\" data-end=\"862\"\u003e⚙️ Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"863\" data-end=\"1128\"\u003e\n\u003cli data-start=\"863\" data-end=\"921\"\u003eType: \u003cstrong data-start=\"871\" data-end=\"919\"\u003eLCD display module with user interface (HMI)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"922\" data-end=\"965\"\u003eCompatibility: \u003cstrong data-start=\"939\" data-end=\"963\"\u003eFronius IG \/ IG Plus\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"966\" data-end=\"997\"\u003eDisplay: \u003cstrong data-start=\"977\" data-end=\"995\"\u003eMonochrome LCD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"998\" data-end=\"1038\"\u003eKeypad: \u003cstrong data-start=\"1008\" data-end=\"1036\"\u003e4-button membrane keypad\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1039\" data-end=\"1088\"\u003eCover: \u003cstrong data-start=\"1048\" data-end=\"1086\"\u003eTransparent protective front panel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1089\" data-end=\"1128\"\u003eConnection: \u003cstrong data-start=\"1103\" data-end=\"1126\"\u003eFlat cable included\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1130\" data-end=\"1154\"\u003e\u003cstrong data-start=\"1130\" data-end=\"1154\"\u003eDisplayed Functions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1155\" data-end=\"1375\"\u003e\n\u003cli data-start=\"1155\" data-end=\"1187\"\u003e\n\u003cstrong data-start=\"1157\" data-end=\"1164\"\u003eNow\u003c\/strong\u003e (instant production)\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1221\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1219\"\u003eDay \/ Year \/ Total energy\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1254\"\u003eSetup and configuration menu\u003c\/li\u003e\n\u003cli data-start=\"1256\" data-end=\"1313\"\u003ePCB: electronic board with integrated microcontroller\u003c\/li\u003e\n\u003cli data-start=\"1314\" data-end=\"1375\"\u003eMounting: \u003cstrong data-start=\"1326\" data-end=\"1373\"\u003edirect installation on inverter front panel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1377\" data-end=\"1380\"\u003e\n\u003ch3 data-start=\"1382\" data-end=\"1403\"\u003e🔧 Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"1404\" data-end=\"1593\"\u003e\n\u003cli data-start=\"1404\" data-end=\"1450\"\u003eMonitoring of photovoltaic production data\u003c\/li\u003e\n\u003cli data-start=\"1451\" data-end=\"1488\"\u003eNavigation through inverter menus\u003c\/li\u003e\n\u003cli data-start=\"1489\" data-end=\"1525\"\u003eDiagnostics and error indication\u003c\/li\u003e\n\u003cli data-start=\"1526\" data-end=\"1565\"\u003eSimple and intuitive user interface\u003c\/li\u003e\n\u003cli data-start=\"1566\" data-end=\"1593\"\u003ePlug \u0026amp; play replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1595\" data-end=\"1598\"\u003e\n\u003ch3 data-start=\"1600\" data-end=\"1619\"\u003e🔌 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1620\" data-end=\"1774\"\u003e\n\u003cli data-start=\"1620\" data-end=\"1667\"\u003eFronius IG \/ IG Plus photovoltaic inverters\u003c\/li\u003e\n\u003cli data-start=\"1668\" data-end=\"1703\"\u003eInverter repair and maintenance\u003c\/li\u003e\n\u003cli data-start=\"1704\" data-end=\"1743\"\u003eReplacement of faulty display units\u003c\/li\u003e\n\u003cli data-start=\"1744\" data-end=\"1774\"\u003eSpare parts for PV systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1776\" data-end=\"1779\"\u003e\n\u003ch3 data-start=\"1781\" data-end=\"1804\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"1805\" data-end=\"1910\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e1× \u003cstrong data-start=\"1810\" data-end=\"1839\"\u003eFronius LCD display board\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1842\" data-end=\"1888\"\u003e1× \u003cstrong data-start=\"1847\" data-end=\"1886\"\u003eFront cover with integrated buttons\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1889\" data-end=\"1910\"\u003e1× \u003cstrong data-start=\"1894\" data-end=\"1908\"\u003eFlat cable\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1912\" data-end=\"1915\"\u003e\n\u003ch3 data-start=\"1917\" data-end=\"1934\"\u003e💡 Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1935\" data-end=\"2156\"\u003e✔ Complete module ready for installation\u003cbr data-start=\"1975\" data-end=\"1978\"\u003e✔ Integrated front protection\u003cbr data-start=\"2007\" data-end=\"2010\"\u003e✔ Full restoration of inverter functionality\u003cbr data-start=\"2054\" data-end=\"2057\"\u003e✔ Compatible with multiple Fronius models\u003cbr data-start=\"2098\" data-end=\"2101\"\u003e✔ Ideal for technicians and maintenance professionals\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53714193449293,"sku":null,"price":50.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5410.jpg?v=1776182335"},{"product_id":"fronius-ig-ig-plus-lcd-display-with-front-panel-and-keypad-user-interface-module-with-flat-cable","title":"Fronius IG \/ IG Plus LCD Display with Front Panel and Keypad – User Interface Module with Flat Cable","description":"\u003cp data-start=\"221\" data-end=\"420\"\u003eOriginal \u003cstrong data-start=\"230\" data-end=\"260\"\u003eFronius LCD display module\u003c\/strong\u003e complete with \u003cstrong data-start=\"275\" data-end=\"325\"\u003efront panel, integrated keypad, and flat cable\u003c\/strong\u003e, designed as a \u003cstrong data-start=\"341\" data-end=\"365\"\u003euser interface (HMI)\u003c\/strong\u003e for \u003cstrong data-start=\"370\" data-end=\"419\"\u003eFronius IG and IG Plus photovoltaic inverters\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"422\" data-end=\"645\"\u003eThis component provides clear and immediate visualization of key operating data, including real-time power production, daily, yearly, and total energy values, as well as access to inverter setup and configuration functions.\u003c\/p\u003e\n\u003cp data-start=\"647\" data-end=\"831\"\u003eThe integrated front panel with protective window ensures durability and protection against dust and wear, making it suitable for professional replacement and maintenance applications.\u003c\/p\u003e\n\u003chr data-start=\"833\" data-end=\"836\"\u003e\n\u003ch3 data-start=\"838\" data-end=\"869\"\u003e⚙️ Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"870\" data-end=\"1275\"\u003e\n\u003cli data-start=\"870\" data-end=\"937\"\u003eType: \u003cstrong data-start=\"878\" data-end=\"935\"\u003eLCD display module with HMI (Human Machine Interface)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"938\" data-end=\"981\"\u003eCompatibility: \u003cstrong data-start=\"955\" data-end=\"979\"\u003eFronius IG \/ IG Plus\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"982\" data-end=\"1021\"\u003eDisplay: \u003cstrong data-start=\"993\" data-end=\"1019\"\u003eMonochrome graphic LCD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1072\"\u003eUser interface: \u003cstrong data-start=\"1040\" data-end=\"1070\"\u003e4 integrated front buttons\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1073\" data-end=\"1134\"\u003ePanel: \u003cstrong data-start=\"1082\" data-end=\"1132\"\u003eFront panel with transparent protective window\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1135\" data-end=\"1174\"\u003eConnection: \u003cstrong data-start=\"1149\" data-end=\"1172\"\u003eFlat cable included\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1176\" data-end=\"1225\"\u003ePCB: printed circuit board with control logic\u003c\/li\u003e\n\u003cli data-start=\"1226\" data-end=\"1275\"\u003eInstallation: \u003cstrong data-start=\"1242\" data-end=\"1273\"\u003eDirect mounting on inverter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1277\" data-end=\"1280\"\u003e\n\u003ch3 data-start=\"1282\" data-end=\"1303\"\u003e🔧 Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"1304\" data-end=\"1533\"\u003e\n\u003cli data-start=\"1304\" data-end=\"1414\"\u003eDisplay of photovoltaic production data:\n\u003cul data-start=\"1351\" data-end=\"1414\"\u003e\n\u003cli data-start=\"1351\" data-end=\"1378\"\u003e\n\u003cstrong data-start=\"1353\" data-end=\"1360\"\u003eNow\u003c\/strong\u003e (instant power)\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1414\"\u003e\u003cstrong data-start=\"1383\" data-end=\"1412\"\u003eDay \/ Year \/ Total energy\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1415\" data-end=\"1448\"\u003eAccess to inverter setup menu\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1493\"\u003eSystem status monitoring and diagnostics\u003c\/li\u003e\n\u003cli data-start=\"1494\" data-end=\"1533\"\u003eSimple navigation via front buttons\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1535\" data-end=\"1538\"\u003e\n\u003ch3 data-start=\"1540\" data-end=\"1559\"\u003e🔌 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1560\" data-end=\"1719\"\u003e\n\u003cli data-start=\"1560\" data-end=\"1607\"\u003eFronius IG \/ IG Plus photovoltaic inverters\u003c\/li\u003e\n\u003cli data-start=\"1608\" data-end=\"1647\"\u003eReplacement of faulty display units\u003c\/li\u003e\n\u003cli data-start=\"1648\" data-end=\"1683\"\u003eInverter repair and maintenance\u003c\/li\u003e\n\u003cli data-start=\"1684\" data-end=\"1719\"\u003eRetrofit of existing PV systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1721\" data-end=\"1724\"\u003e\n\u003ch3 data-start=\"1726\" data-end=\"1749\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"1750\" data-end=\"1855\"\u003e\n\u003cli data-start=\"1750\" data-end=\"1787\"\u003e1× \u003cstrong data-start=\"1755\" data-end=\"1785\"\u003eFronius LCD display module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1788\" data-end=\"1833\"\u003e1× \u003cstrong data-start=\"1793\" data-end=\"1831\"\u003eFront panel with integrated keypad\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1834\" data-end=\"1855\"\u003e1× \u003cstrong data-start=\"1839\" data-end=\"1853\"\u003eFlat cable\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1857\" data-end=\"1860\"\u003e\n\u003ch3 data-start=\"1862\" data-end=\"1879\"\u003e💡 Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1880\" data-end=\"2066\"\u003e✔ Complete module ready for use\u003cbr data-start=\"1911\" data-end=\"1914\"\u003e✔ Quick and easy installation\u003cbr data-start=\"1943\" data-end=\"1946\"\u003e✔ Integrated front protection\u003cbr data-start=\"1975\" data-end=\"1978\"\u003e✔ Wide compatibility within Fronius IG series\u003cbr data-start=\"2023\" data-end=\"2026\"\u003e✔ Ideal for technicians and installers\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53714233524557,"sku":null,"price":50.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5414.jpg?v=1776183401"},{"product_id":"meteocontrol-blue-log-x-series-xm-200-data-logger-and-monitoring-system-for-photovoltaic-plants","title":"Meteocontrol blue’Log X-Series XM-200 – Data Logger and Monitoring System for Photovoltaic Plants","description":"\u003cp data-start=\"216\" data-end=\"525\"\u003eThe \u003cstrong data-start=\"220\" data-end=\"261\"\u003eMeteocontrol blue’Log X-Series XM-200\u003c\/strong\u003e is a professional device designed for \u003cstrong data-start=\"300\" data-end=\"369\"\u003emonitoring, data acquisition, and control of photovoltaic systems\u003c\/strong\u003e. Developed for commercial and industrial applications, this data logger enables continuous supervision of inverter performance and overall plant operation.\u003c\/p\u003e\n\u003cp data-start=\"527\" data-end=\"708\"\u003eThe unit acts as a \u003cstrong data-start=\"546\" data-end=\"581\"\u003ecentral data acquisition system\u003c\/strong\u003e, collecting data from inverters, energy meters, and environmental sensors, and transmitting it to remote monitoring platforms.\u003c\/p\u003e\n\u003chr data-start=\"710\" data-end=\"713\"\u003e\n\u003ch3 data-start=\"715\" data-end=\"736\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"737\" data-end=\"1018\"\u003e\n\u003cli data-start=\"737\" data-end=\"782\"\u003eReal-time monitoring of energy production\u003c\/li\u003e\n\u003cli data-start=\"783\" data-end=\"827\"\u003eCommunication with multi-brand inverters\u003c\/li\u003e\n\u003cli data-start=\"828\" data-end=\"869\"\u003eData logging and performance analysis\u003c\/li\u003e\n\u003cli data-start=\"870\" data-end=\"905\"\u003eDiagnostics and fault reporting\u003c\/li\u003e\n\u003cli data-start=\"906\" data-end=\"954\"\u003eIntegration with cloud platforms (e.g. VCOM)\u003c\/li\u003e\n\u003cli data-start=\"955\" data-end=\"1018\"\u003ePlant control and management (curtailment, setpoints, etc.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1020\" data-end=\"1023\"\u003e\n\u003ch3 data-start=\"1025\" data-end=\"1056\"\u003e🔌 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1057\" data-end=\"1152\"\u003e\n\u003cli data-start=\"1057\" data-end=\"1096\"\u003eModel: \u003cstrong data-start=\"1066\" data-end=\"1094\"\u003eblue’Log X-Series XM-200\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1097\" data-end=\"1152\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eMeteocontrol\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1154\" data-end=\"1171\"\u003e\u003cstrong data-start=\"1154\" data-end=\"1171\"\u003ePower Supply:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1172\" data-end=\"1209\"\u003e\n\u003cli data-start=\"1172\" data-end=\"1209\"\u003e\n\u003cstrong data-start=\"1174\" data-end=\"1185\"\u003e24 V DC\u003c\/strong\u003e (typ. 5 W, max. 80 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1211\" data-end=\"1223\"\u003e\u003cstrong data-start=\"1211\" data-end=\"1223\"\u003eDisplay:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1224\" data-end=\"1270\"\u003e\n\u003cli data-start=\"1224\" data-end=\"1270\"\u003eIntegrated \u003cstrong data-start=\"1237\" data-end=\"1268\"\u003eLCD for local configuration\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1272\" data-end=\"1287\"\u003e\u003cstrong data-start=\"1272\" data-end=\"1287\"\u003eInterfaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1288\" data-end=\"1391\"\u003e\n\u003cli data-start=\"1288\" data-end=\"1300\"\u003eUSB port\u003c\/li\u003e\n\u003cli data-start=\"1301\" data-end=\"1345\"\u003eSerial communication (\u003cstrong data-start=\"1325\" data-end=\"1342\"\u003eRS485 \/ RS232\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1391\"\u003eEthernet (network and cloud connectivity)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1393\" data-end=\"1412\"\u003e\u003cstrong data-start=\"1393\" data-end=\"1412\"\u003eOther Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1413\" data-end=\"1531\"\u003e\n\u003cli data-start=\"1413\" data-end=\"1439\"\u003eIntegrated MAC address\u003c\/li\u003e\n\u003cli data-start=\"1440\" data-end=\"1499\"\u003eInstallation: \u003cstrong data-start=\"1456\" data-end=\"1497\"\u003eDIN rail or electrical panel mounting\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1500\" data-end=\"1531\"\u003eOrigin: \u003cstrong data-start=\"1510\" data-end=\"1529\"\u003eMade in Germany\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1533\" data-end=\"1536\"\u003e\n\u003ch3 data-start=\"1538\" data-end=\"1557\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1558\" data-end=\"1717\"\u003e\n\u003cli data-start=\"1558\" data-end=\"1608\"\u003eCommercial and industrial photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1609\" data-end=\"1639\"\u003eUtility-scale solar plants\u003c\/li\u003e\n\u003cli data-start=\"1640\" data-end=\"1672\"\u003eMulti-inverter installations\u003c\/li\u003e\n\u003cli data-start=\"1673\" data-end=\"1717\"\u003eOperation \u0026amp; Maintenance (O\u0026amp;M) monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1719\" data-end=\"1722\"\u003e\n\u003ch3 data-start=\"1724\" data-end=\"1753\"\u003e🧩 Role within the System\u003c\/h3\u003e\n\u003cp data-start=\"1754\" data-end=\"1791\"\u003eThe \u003cstrong data-start=\"1758\" data-end=\"1777\"\u003eblue’Log XM-200\u003c\/strong\u003e functions as:\u003c\/p\u003e\n\u003cul data-start=\"1792\" data-end=\"1960\"\u003e\n\u003cli data-start=\"1792\" data-end=\"1855\"\u003eCommunication gateway between inverters and cloud platforms\u003c\/li\u003e\n\u003cli data-start=\"1856\" data-end=\"1913\"\u003eCentral control unit for optimizing plant performance\u003c\/li\u003e\n\u003cli data-start=\"1914\" data-end=\"1960\"\u003eDiagnostic tool for preventive maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1962\" data-end=\"1965\"\u003e\n\u003ch3 data-start=\"1967\" data-end=\"1984\"\u003e💡 Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1985\" data-end=\"2199\"\u003e✔ High compatibility with multiple inverter brands\u003cbr data-start=\"2035\" data-end=\"2038\"\u003e✔ Reliable and continuous monitoring\u003cbr data-start=\"2074\" data-end=\"2077\"\u003e✔ Remote access to system data\u003cbr data-start=\"2107\" data-end=\"2110\"\u003e✔ Faster fault detection and intervention\u003cbr data-start=\"2151\" data-end=\"2154\"\u003e✔ Scalable solution for large installations\u003c\/p\u003e\n\u003chr data-start=\"2201\" data-end=\"2204\"\u003e\n\u003ch3 data-start=\"2206\" data-end=\"2223\"\u003e📌 Conclusion\u003c\/h3\u003e\n\u003cp data-start=\"2225\" data-end=\"2476\"\u003eThe \u003cstrong data-start=\"2229\" data-end=\"2270\"\u003eMeteocontrol blue’Log X-Series XM-200\u003c\/strong\u003e is a key component for intelligent management of modern photovoltaic systems. It provides control, visibility, and performance optimization, making it essential for operators and maintenance professionals.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53754231193933,"sku":null,"price":1200.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5445.jpg?v=1776701745"},{"product_id":"filter-dc-emi-emc-epcos-b84112a0032r158-32-a-800-v-dc-common-differential-mode-pcb-mount","title":"Filter DC EMI\/EMC – EPCOS B84112A0032R158| 32 A | 800 V DC | Common \u0026 Differential Mode | PCB Mount","description":"\u003cp data-start=\"148\" data-end=\"525\"\u003eThe \u003cstrong data-start=\"152\" data-end=\"177\"\u003eEPCOS B84112A0032R158\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"200\" data-end=\"226\"\u003eDC line EMI\/EMC filter\u003c\/strong\u003e designed for suppression of electromagnetic interference in industrial and photovoltaic applications. Based on EPCOS (TDK) technology, the module integrates a high-efficiency \u003cstrong data-start=\"402\" data-end=\"432\"\u003etoroidal common-mode choke\u003c\/strong\u003e and \u003cstrong data-start=\"437\" data-end=\"459\"\u003eX-class capacitors\u003c\/strong\u003e to filter high-frequency noise generated by switching converters.\u003c\/p\u003e\n\u003cp data-start=\"527\" data-end=\"744\"\u003eOptimized for use on \u003cstrong data-start=\"548\" data-end=\"590\"\u003eDC bus lines of photovoltaic inverters\u003c\/strong\u003e, this filter reduces conducted noise in both \u003cstrong data-start=\"636\" data-end=\"673\"\u003ecommon mode and differential mode\u003c\/strong\u003e, helping ensure EMC compliance and improving overall system stability.\u003c\/p\u003e\n\u003chr data-start=\"746\" data-end=\"749\"\u003e\n\u003ch3 data-section-id=\"1xucbcs\" data-start=\"751\" data-end=\"771\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"772\" data-end=\"978\"\u003e\n\u003cli data-section-id=\"1g3d627\" data-start=\"772\" data-end=\"802\"\u003eModel: \u003cstrong data-start=\"781\" data-end=\"800\"\u003eB84112A0032R158\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ucutym\" data-start=\"803\" data-end=\"844\"\u003eType: \u003cstrong data-start=\"811\" data-end=\"842\"\u003eEMI\/EMC filter for DC lines\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qf4c2l\" data-start=\"845\" data-end=\"872\"\u003eRated current: \u003cstrong data-start=\"862\" data-end=\"870\"\u003e32 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x3kk75\" data-start=\"873\" data-end=\"910\"\u003eRated voltage: \u003cstrong data-start=\"890\" data-end=\"908\"\u003eup to 800 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j1jhns\" data-start=\"911\" data-end=\"978\"\u003eTopology: \u003cstrong data-start=\"923\" data-end=\"976\"\u003eCombined filter (common mode + differential mode)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"980\" data-end=\"995\"\u003e\u003cstrong data-start=\"980\" data-end=\"995\"\u003eInductance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"996\" data-end=\"1036\"\u003e\n\u003cli data-section-id=\"hrhlyi\" data-start=\"996\" data-end=\"1036\"\u003eHigh-permeability \u003cstrong data-start=\"1016\" data-end=\"1034\"\u003etoroidal choke\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1038\" data-end=\"1053\"\u003e\u003cstrong data-start=\"1038\" data-end=\"1053\"\u003eCapacitors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1054\" data-end=\"1324\"\u003e\n\u003cli data-section-id=\"1790iu4\" data-start=\"1054\" data-end=\"1095\"\u003e\n\u003cstrong data-start=\"1056\" data-end=\"1068\"\u003eMKP 1 µF\u003c\/strong\u003e (differential filtering)\u003c\/li\u003e\n\u003cli data-section-id=\"1qnmdtm\" data-start=\"1096\" data-end=\"1142\"\u003e\n\u003cstrong data-start=\"1098\" data-end=\"1111\"\u003e2 × 22 nF\u003c\/strong\u003e (high-frequency suppression)\u003c\/li\u003e\n\u003cli data-section-id=\"w2826l\" data-start=\"1144\" data-end=\"1205\"\u003eOperating temperature: \u003cstrong data-start=\"1169\" data-end=\"1203\"\u003eup to approx. 65°C (TR = 65°C)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"i6j8uk\" data-start=\"1206\" data-end=\"1259\"\u003eConnections: \u003cstrong data-start=\"1221\" data-end=\"1257\"\u003eScrew terminals for high current\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"y3mgic\" data-start=\"1260\" data-end=\"1324\"\u003eMounting: \u003cstrong data-start=\"1272\" data-end=\"1322\"\u003ePCB mounting with reinforced mechanical fixing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1326\" data-end=\"1329\"\u003e\n\u003ch3 data-section-id=\"1xl28h0\" data-start=\"1331\" data-end=\"1358\"\u003e🔌 Typical Applications\u003c\/h3\u003e\n\u003cul data-start=\"1359\" data-end=\"1542\"\u003e\n\u003cli data-section-id=\"ifc86q\" data-start=\"1359\" data-end=\"1416\"\u003ePhotovoltaic inverters (string and central inverters)\u003c\/li\u003e\n\u003cli data-section-id=\"q3gjte\" data-start=\"1417\" data-end=\"1458\"\u003eIndustrial DC\/DC and DC\/AC converters\u003c\/li\u003e\n\u003cli data-section-id=\"o8pmxr\" data-start=\"1459\" data-end=\"1503\"\u003eEnergy storage systems (battery systems)\u003c\/li\u003e\n\u003cli data-section-id=\"38kg0p\" data-start=\"1504\" data-end=\"1542\"\u003ePower electronics and motor drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1544\" data-end=\"1547\"\u003e\n\u003ch3 data-section-id=\"4m3ld1\" data-start=\"1549\" data-end=\"1563\"\u003e⚡ Function\u003c\/h3\u003e\n\u003cul data-start=\"1564\" data-end=\"1760\"\u003e\n\u003cli data-section-id=\"pnpesk\" data-start=\"1564\" data-end=\"1607\"\u003eReduction of conducted EMI interference\u003c\/li\u003e\n\u003cli data-section-id=\"ufzeve\" data-start=\"1608\" data-end=\"1655\"\u003eFiltering of high-frequency switching noise\u003c\/li\u003e\n\u003cli data-section-id=\"1bbbg1i\" data-start=\"1656\" data-end=\"1705\"\u003eProtection of DC lines and downstream devices\u003c\/li\u003e\n\u003cli data-section-id=\"qg555h\" data-start=\"1706\" data-end=\"1760\"\u003eImprovement of electromagnetic compatibility (EMC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1762\" data-end=\"1765\"\u003e\n\u003ch3 data-section-id=\"1u9mppd\" data-start=\"1767\" data-end=\"1789\"\u003e🧩 Technical Notes\u003c\/h3\u003e\n\u003cp data-start=\"1791\" data-end=\"2003\"\u003eThis filter is designed for \u003cstrong data-start=\"1819\" data-end=\"1851\"\u003ehigh-voltage DC applications\u003c\/strong\u003e and is \u003cstrong data-start=\"1859\" data-end=\"1901\"\u003enot suitable for standard AC mains use\u003c\/strong\u003e (e.g. household Schuko systems). Intended exclusively for industrial and photovoltaic applications.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53760023331149,"sku":null,"price":40.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5458_0e642ed1-1970-4466-a763-e26e65075e3d.jpg?v=1776793031"},{"product_id":"abb-sace-tmax-t1b-160-circuit-breaker-80-a-3-pole-690-v-ac-thermal-magnetic-protection","title":"ABB SACE Tmax T1B 160 – Circuit Breaker | 80 A | 3-Pole | 690 V AC | Thermal-Magnetic Protection","description":"\u003cp data-start=\"144\" data-end=\"477\"\u003eThe \u003cstrong data-start=\"148\" data-end=\"173\"\u003eABB SACE Tmax T1B 160\u003c\/strong\u003e is a \u003cstrong data-start=\"179\" data-end=\"215\"\u003ethermal-magnetic circuit breaker\u003c\/strong\u003e designed for the protection of electrical lines and industrial installations against \u003cstrong data-start=\"301\" data-end=\"333\"\u003eoverloads and short circuits\u003c\/strong\u003e. It is part of the \u003cstrong data-start=\"353\" data-end=\"371\"\u003eTmax T1 series\u003c\/strong\u003e, offering high breaking capacity and reliable performance in low-voltage applications up to \u003cstrong data-start=\"464\" data-end=\"476\"\u003e690 V AC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"479\" data-end=\"656\"\u003eThis device is suitable for installation in \u003cstrong data-start=\"523\" data-end=\"605\"\u003eindustrial switchboards, photovoltaic systems, and power distribution networks\u003c\/strong\u003e, ensuring safe operation and effective protection.\u003c\/p\u003e\n\u003chr data-start=\"658\" data-end=\"661\"\u003e\n\u003ch3 data-start=\"663\" data-end=\"699\"\u003e⚙️ Main Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"700\" data-end=\"863\"\u003e\n\u003cli data-start=\"700\" data-end=\"779\"\u003eManufacturer \/ Series: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eABB\u003c\/span\u003e\u003c\/span\u003e – SACE Tmax T1\u003c\/li\u003e\n\u003cli data-start=\"780\" data-end=\"802\"\u003eModel: \u003cstrong data-start=\"789\" data-end=\"800\"\u003eT1B 160\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"803\" data-end=\"835\"\u003eRated current (In): \u003cstrong data-start=\"825\" data-end=\"833\"\u003e80 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"836\" data-end=\"863\"\u003eNumber of poles: \u003cstrong data-start=\"855\" data-end=\"861\"\u003e3P\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"865\" data-end=\"888\"\u003e\u003cstrong data-start=\"865\" data-end=\"888\"\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"889\" data-end=\"1057\"\u003e\n\u003cli data-start=\"889\" data-end=\"943\"\u003eRated operational voltage (Ue): \u003cstrong data-start=\"923\" data-end=\"941\"\u003eup to 690 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"944\" data-end=\"982\"\u003eInsulation voltage (Ui): \u003cstrong data-start=\"971\" data-end=\"980\"\u003e800 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"983\" data-end=\"1029\"\u003eImpulse withstand voltage (Uimp): \u003cstrong data-start=\"1019\" data-end=\"1027\"\u003e8 kV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1030\" data-end=\"1057\"\u003eFrequency: \u003cstrong data-start=\"1043\" data-end=\"1055\"\u003e50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1059\" data-end=\"1062\"\u003e\n\u003ch3 data-start=\"1064\" data-end=\"1093\"\u003e⚡ Breaking Capacity (Icu)\u003c\/h3\u003e\n\u003cul data-start=\"1094\" data-end=\"1207\"\u003e\n\u003cli data-start=\"1094\" data-end=\"1115\"\u003e\u003cstrong data-start=\"1096\" data-end=\"1113\"\u003e25 kA @ 230 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1116\" data-end=\"1143\"\u003e\u003cstrong data-start=\"1118\" data-end=\"1141\"\u003e16 kA @ 400 \/ 415 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1165\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1163\"\u003e10 kA @ 440 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1166\" data-end=\"1186\"\u003e\u003cstrong data-start=\"1168\" data-end=\"1184\"\u003e8 kA @ 500 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1187\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1205\"\u003e3 kA @ 690 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1209\" data-end=\"1212\"\u003e\n\u003ch3 data-start=\"1214\" data-end=\"1252\"\u003e🔥 Thermal Protection (Adjustable)\u003c\/h3\u003e\n\u003cul data-start=\"1253\" data-end=\"1347\"\u003e\n\u003cli data-start=\"1253\" data-end=\"1347\"\u003eAdjustment range (I1 at 40°C):\n\u003cul data-start=\"1290\" data-end=\"1347\"\u003e\n\u003cli data-start=\"1290\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1292\" data-end=\"1305\"\u003eMin: 56 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1327\"\u003e\u003cstrong data-start=\"1312\" data-end=\"1325\"\u003eMed: 68 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1330\" data-end=\"1347\"\u003e\u003cstrong data-start=\"1332\" data-end=\"1345\"\u003eMax: 80 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1349\" data-end=\"1352\"\u003e\n\u003ch3 data-start=\"1354\" data-end=\"1395\"\u003e⚡ Magnetic Protection (Instantaneous)\u003c\/h3\u003e\n\u003cul data-start=\"1396\" data-end=\"1463\"\u003e\n\u003cli data-start=\"1396\" data-end=\"1463\"\u003e\n\u003cstrong data-start=\"1398\" data-end=\"1411\"\u003eI3: 800 A\u003c\/strong\u003e (instantaneous trip for short circuit protection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1465\" data-end=\"1468\"\u003e\n\u003ch3 data-start=\"1470\" data-end=\"1502\"\u003e🔌 Accessories \u0026amp; Connections\u003c\/h3\u003e\n\u003cp data-start=\"1504\" data-end=\"1531\"\u003e\u003cstrong data-start=\"1504\" data-end=\"1531\"\u003eCompatible accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1532\" data-end=\"1663\"\u003e\n\u003cli data-start=\"1532\" data-end=\"1582\"\u003eShunt Opening Release (\u003cstrong data-start=\"1557\" data-end=\"1564\"\u003eSOR\u003c\/strong\u003e): 24–30 V AC\/DC\u003c\/li\u003e\n\u003cli data-start=\"1583\" data-end=\"1617\"\u003eUndervoltage Release (\u003cstrong data-start=\"1607\" data-end=\"1614\"\u003eUVR\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1618\" data-end=\"1663\"\u003eAuxiliary contacts (\u003cstrong data-start=\"1640\" data-end=\"1647\"\u003eAUX\u003c\/strong\u003e): 250 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1665\" data-end=\"1684\"\u003e\u003cstrong data-start=\"1665\" data-end=\"1684\"\u003eCable sections:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1685\" data-end=\"1776\"\u003e\n\u003cli data-start=\"1685\" data-end=\"1712\"\u003eRigid: \u003cstrong data-start=\"1694\" data-end=\"1710\"\u003e2.5 – 70 mm²\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1713\" data-end=\"1743\"\u003eFlexible: \u003cstrong data-start=\"1725\" data-end=\"1741\"\u003e2.5 – 50 mm²\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1745\" data-end=\"1776\"\u003eTightening torque: \u003cstrong data-start=\"1766\" data-end=\"1774\"\u003e7 Nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1778\" data-end=\"1781\"\u003e\n\u003ch3 data-start=\"1783\" data-end=\"1802\"\u003e🧩 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1803\" data-end=\"1979\"\u003e\n\u003cli data-start=\"1803\" data-end=\"1835\"\u003eIndustrial electrical panels\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1893\"\u003ePhotovoltaic systems (AC\/DC protection on power side)\u003c\/li\u003e\n\u003cli data-start=\"1894\" data-end=\"1936\"\u003eLow-voltage power distribution systems\u003c\/li\u003e\n\u003cli data-start=\"1937\" data-end=\"1979\"\u003eIndustrial machinery and installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1981\" data-end=\"1984\"\u003e\n\u003ch3 data-start=\"1986\" data-end=\"2006\"\u003e✅ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"2007\" data-end=\"2165\"\u003e\n\u003cli data-start=\"2007\" data-end=\"2040\"\u003eOverload protection (thermal)\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2080\"\u003eShort-circuit protection (magnetic)\u003c\/li\u003e\n\u003cli data-start=\"2081\" data-end=\"2117\"\u003eManual disconnection of the line\u003c\/li\u003e\n\u003cli data-start=\"2118\" data-end=\"2165\"\u003eIntegration with control and safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2167\" data-end=\"2170\"\u003e\n\u003ch3 data-start=\"2172\" data-end=\"2184\"\u003e📌 Notes\u003c\/h3\u003e\n\u003cp data-start=\"2186\" data-end=\"2342\"\u003eCompliant with \u003cstrong data-start=\"2201\" data-end=\"2216\"\u003eIEC 60947-2\u003c\/strong\u003e, this device is designed for use in industrial environments requiring high standards of safety, reliability, and performance.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53765154242893,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5477.jpg?v=1776873776"},{"product_id":"kaco-powador-25000xi-30000xi-33000xi-control-board-with-power-supply-relays-inverter-auxiliary-pcb","title":"KACO Powador 25000XI \/ 30000XI \/ 33000XI – Control Board with Power Supply \u0026 Relays | Inverter Auxiliary PCB","description":"\u003cp data-start=\"156\" data-end=\"434\"\u003eThe \u003cstrong data-start=\"160\" data-end=\"217\"\u003econtrol board with integrated power supply and relays\u003c\/strong\u003e is an electronic module designed for \u003cstrong data-start=\"255\" data-end=\"324\"\u003eKACO Powador 25000XI, 30000XI, and 33000XI photovoltaic inverters\u003c\/strong\u003e. It is used to manage auxiliary functions, control logic, and interfacing with the inverter’s power circuits.\u003c\/p\u003e\n\u003cp data-start=\"436\" data-end=\"701\"\u003eThe board includes a \u003cstrong data-start=\"457\" data-end=\"497\"\u003elinear power supply with transformer\u003c\/strong\u003e, analog and digital control circuits, and \u003cstrong data-start=\"540\" data-end=\"575\"\u003eelectromechanical relay outputs\u003c\/strong\u003e for handling internal signals and actuators. It ensures proper monitoring, regulation, and protection of the inverter system.\u003c\/p\u003e\n\u003chr data-start=\"703\" data-end=\"706\"\u003e\n\u003ch3 data-start=\"708\" data-end=\"744\"\u003e⚙️ Main Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"745\" data-end=\"1053\"\u003e\n\u003cli data-start=\"745\" data-end=\"856\"\u003eCompatibility:\n\u003cul data-start=\"766\" data-end=\"856\"\u003e\n\u003cli data-start=\"766\" data-end=\"794\"\u003e\u003cstrong data-start=\"768\" data-end=\"792\"\u003eKACO Powador 25000XI\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"797\" data-end=\"825\"\u003e\u003cstrong data-start=\"799\" data-end=\"823\"\u003eKACO Powador 30000XI\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"828\" data-end=\"856\"\u003e\u003cstrong data-start=\"830\" data-end=\"854\"\u003eKACO Powador 33000XI\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"858\" data-end=\"917\"\u003eType: \u003cstrong data-start=\"866\" data-end=\"915\"\u003eControl board \/ auxiliary power supply module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"918\" data-end=\"983\"\u003ePower supply: \u003cstrong data-start=\"934\" data-end=\"981\"\u003eIntegrated transformer (AC → DC conversion)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"984\" data-end=\"1053\"\u003eOutputs: \u003cstrong data-start=\"995\" data-end=\"1051\"\u003eElectromechanical relays for signal and load control\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1055\" data-end=\"1075\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1075\"\u003eMain Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1076\" data-end=\"1283\"\u003e\n\u003cli data-start=\"1076\" data-end=\"1104\"\u003eEncapsulated transformer\u003c\/li\u003e\n\u003cli data-start=\"1105\" data-end=\"1124\"\u003eProtection fuse\u003c\/li\u003e\n\u003cli data-start=\"1125\" data-end=\"1162\"\u003eElectrolytic filtering capacitors\u003c\/li\u003e\n\u003cli data-start=\"1163\" data-end=\"1206\"\u003eDIP integrated circuits (control logic)\u003c\/li\u003e\n\u003cli data-start=\"1207\" data-end=\"1251\"\u003eScrew terminals for external connections\u003c\/li\u003e\n\u003cli data-start=\"1252\" data-end=\"1283\"\u003eSystem interface connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1285\" data-end=\"1288\"\u003e\n\u003ch3 data-start=\"1290\" data-end=\"1311\"\u003e🔌 Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"1312\" data-end=\"1581\"\u003e\n\u003cli data-start=\"1312\" data-end=\"1366\"\u003eGeneration and stabilization of auxiliary voltages\u003c\/li\u003e\n\u003cli data-start=\"1367\" data-end=\"1406\"\u003eControl logic and signal management\u003c\/li\u003e\n\u003cli data-start=\"1407\" data-end=\"1473\"\u003eRelay control for activation\/deactivation of internal circuits\u003c\/li\u003e\n\u003cli data-start=\"1474\" data-end=\"1533\"\u003eInterface between control electronics and power section\u003c\/li\u003e\n\u003cli data-start=\"1534\" data-end=\"1581\"\u003eSupport for safety and diagnostic functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1583\" data-end=\"1586\"\u003e\n\u003ch3 data-start=\"1588\" data-end=\"1607\"\u003e🧩 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1608\" data-end=\"1744\"\u003e\n\u003cli data-start=\"1608\" data-end=\"1657\"\u003eKACO Powador XI series photovoltaic inverters\u003c\/li\u003e\n\u003cli data-start=\"1658\" data-end=\"1693\"\u003eDC\/AC energy conversion systems\u003c\/li\u003e\n\u003cli data-start=\"1694\" data-end=\"1744\"\u003eInverter control panels and electronic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1746\" data-end=\"1749\"\u003e\n\u003ch3 data-start=\"1751\" data-end=\"1773\"\u003e⚠️ Technical Notes\u003c\/h3\u003e\n\u003cp data-start=\"1775\" data-end=\"1997\"\u003eThis is an \u003cstrong data-start=\"1786\" data-end=\"1827\"\u003eOEM-specific board for KACO inverters\u003c\/strong\u003e and is not suitable for standalone use without integration into the original system. Installation and configuration should be performed by qualified technical personnel.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53765193040205,"sku":null,"price":360.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5483.jpg?v=1776874943"},{"product_id":"abb-sace-tmax-t1d-160-molded-case-circuit-breaker-160-a-690-v-ac-800-v-2p-3p-iec-60947-2","title":"ABB SACE Tmax T1D 160 – Molded Case Circuit Breaker | 160 A | 690 V AC \/ 800 V | 2P\/3P | IEC 60947-2","description":"\u003cp data-start=\"148\" data-end=\"348\"\u003eThe \u003cstrong data-start=\"152\" data-end=\"177\"\u003eABB SACE Tmax T1D 160\u003c\/strong\u003e is a \u003cstrong data-start=\"183\" data-end=\"221\"\u003emolded case circuit breaker (MCCB)\u003c\/strong\u003e designed for the protection of electrical lines in industrial and civil applications against \u003cstrong data-start=\"315\" data-end=\"347\"\u003eoverloads and short circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"350\" data-end=\"516\"\u003eCompliant with \u003cstrong data-start=\"365\" data-end=\"380\"\u003eIEC 60947-2\u003c\/strong\u003e, this device is suitable for installation in \u003cstrong data-start=\"426\" data-end=\"461\"\u003elow-voltage distribution panels\u003c\/strong\u003e, ensuring high reliability and protection performance.\u003c\/p\u003e\n\u003chr data-start=\"518\" data-end=\"521\"\u003e\n\u003ch3 data-start=\"523\" data-end=\"555\"\u003e⚙️ Electrical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"556\" data-end=\"722\"\u003e\n\u003cli data-start=\"556\" data-end=\"611\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eABB\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"612\" data-end=\"637\"\u003eSeries: \u003cstrong data-start=\"622\" data-end=\"635\"\u003eSACE Tmax\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"638\" data-end=\"660\"\u003eModel: \u003cstrong data-start=\"647\" data-end=\"658\"\u003eT1D 160\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"694\"\u003eRated current (In): \u003cstrong data-start=\"683\" data-end=\"692\"\u003e160 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"695\" data-end=\"722\"\u003eFrequency: \u003cstrong data-start=\"708\" data-end=\"720\"\u003e50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"724\" data-end=\"727\"\u003e\n\u003ch3 data-start=\"729\" data-end=\"751\"\u003e🔌 Voltage Ratings\u003c\/h3\u003e\n\u003cul data-start=\"752\" data-end=\"892\"\u003e\n\u003cli data-start=\"752\" data-end=\"806\"\u003eRated operational voltage (Ue): \u003cstrong data-start=\"786\" data-end=\"804\"\u003eup to 690 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"807\" data-end=\"845\"\u003eInsulation voltage (Ui): \u003cstrong data-start=\"834\" data-end=\"843\"\u003e800 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"846\" data-end=\"892\"\u003eImpulse withstand voltage (Uimp): \u003cstrong data-start=\"882\" data-end=\"890\"\u003e8 kV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"894\" data-end=\"897\"\u003e\n\u003ch3 data-start=\"899\" data-end=\"927\"\u003e⚡ Currents \u0026amp; Performance\u003c\/h3\u003e\n\u003cul data-start=\"928\" data-end=\"986\"\u003e\n\u003cli data-start=\"928\" data-end=\"986\"\u003eIndicated operating current: \u003cstrong data-start=\"959\" data-end=\"968\"\u003e125 A\u003c\/strong\u003e (as configured)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"988\" data-end=\"1013\"\u003e\u003cstrong data-start=\"988\" data-end=\"1013\"\u003eUtilization category:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1014\" data-end=\"1071\"\u003e\n\u003cli data-start=\"1014\" data-end=\"1056\"\u003e\n\u003cstrong data-start=\"1016\" data-end=\"1026\"\u003eAC-23A\u003c\/strong\u003e (mixed loads \/ motor loads)\u003c\/li\u003e\n\u003cli data-start=\"1057\" data-end=\"1071\"\u003e\u003cstrong data-start=\"1059\" data-end=\"1069\"\u003eDC-23A\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1073\" data-end=\"1096\"\u003e\u003cstrong data-start=\"1073\" data-end=\"1096\"\u003ePole configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1097\" data-end=\"1132\"\u003e\n\u003cli data-start=\"1097\" data-end=\"1132\"\u003e\u003cstrong data-start=\"1099\" data-end=\"1130\"\u003e2 poles in series \/ 3 poles\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1134\" data-end=\"1137\"\u003e\n\u003ch3 data-start=\"1139\" data-end=\"1166\"\u003e🛡️ Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"1167\" data-end=\"1278\"\u003e\n\u003cli data-start=\"1167\" data-end=\"1200\"\u003eThermal protection (overload)\u003c\/li\u003e\n\u003cli data-start=\"1201\" data-end=\"1240\"\u003eMagnetic protection (short circuit)\u003c\/li\u003e\n\u003cli data-start=\"1241\" data-end=\"1278\"\u003eHigh industrial breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1280\" data-end=\"1283\"\u003e\n\u003ch3 data-start=\"1285\" data-end=\"1312\"\u003e🔘 Controls \u0026amp; Functions\u003c\/h3\u003e\n\u003cul data-start=\"1313\" data-end=\"1425\"\u003e\n\u003cli data-start=\"1313\" data-end=\"1336\"\u003eManual ON\/OFF lever\u003c\/li\u003e\n\u003cli data-start=\"1337\" data-end=\"1394\"\u003eStatus indication:\n\u003cul data-start=\"1362\" data-end=\"1394\"\u003e\n\u003cli data-start=\"1362\" data-end=\"1376\"\u003e\u003cstrong data-start=\"1364\" data-end=\"1374\"\u003eI (ON)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1394\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1392\"\u003eO (OFF)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1425\"\u003eIntegrated \u003cstrong data-start=\"1408\" data-end=\"1423\"\u003eTEST button\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1427\" data-end=\"1430\"\u003e\n\u003ch3 data-start=\"1432\" data-end=\"1461\"\u003e🏗️ Construction Features\u003c\/h3\u003e\n\u003cul data-start=\"1462\" data-end=\"1575\"\u003e\n\u003cli data-start=\"1462\" data-end=\"1492\"\u003eCompact molded case design\u003c\/li\u003e\n\u003cli data-start=\"1493\" data-end=\"1521\"\u003eRobust screw connections\u003c\/li\u003e\n\u003cli data-start=\"1522\" data-end=\"1553\"\u003ePanel mounting installation\u003c\/li\u003e\n\u003cli data-start=\"1554\" data-end=\"1575\"\u003e\u003cstrong data-start=\"1556\" data-end=\"1573\"\u003eMade in Italy\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1577\" data-end=\"1580\"\u003e\n\u003ch3 data-start=\"1582\" data-end=\"1600\"\u003e⚡ Applications\u003c\/h3\u003e\n\u003cul data-start=\"1601\" data-end=\"1769\"\u003e\n\u003cli data-start=\"1601\" data-end=\"1635\"\u003eIndustrial distribution panels\u003c\/li\u003e\n\u003cli data-start=\"1636\" data-end=\"1671\"\u003eProtection of three-phase lines\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1720\"\u003ePhotovoltaic systems (AC\/DC side protection)\u003c\/li\u003e\n\u003cli data-start=\"1721\" data-end=\"1769\"\u003eIndustrial automation and electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53779002425677,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5495.jpg?v=1777123310"},{"product_id":"abb-power-one-fimer-trio-20-27-6-kw-switching-power-supply-board-smps-rev-3m22-inverter-psu-module","title":"ABB \/ Power-One \/ FIMER TRIO 20–27.6 kW – Switching Power Supply Board | SMPS | Rev. 3M22 | Inverter PSU Module","description":"\u003ch3 data-start=\"120\" data-end=\"157\"\u003eDetailed Technical Description\u003c\/h3\u003e\n\u003cp data-start=\"159\" data-end=\"373\"\u003eThe \u003cstrong data-start=\"163\" data-end=\"226\"\u003eABB \/ Power-One \/ FIMER SMPS Power Supply Board (Rev. 3M22)\u003c\/strong\u003e is an original electronic module designed for \u003cstrong data-start=\"273\" data-end=\"322\"\u003ehigh-power three-phase photovoltaic inverters\u003c\/strong\u003e of the \u003cstrong data-start=\"330\" data-end=\"372\"\u003eAurora TRIO 20.0 kW and 27.6 kW series\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"375\" data-end=\"578\"\u003eThis board operates as a \u003cstrong data-start=\"400\" data-end=\"433\"\u003eswitching power supply (SMPS)\u003c\/strong\u003e, converting energy from the internal DC bus and generating all the \u003cstrong data-start=\"501\" data-end=\"523\"\u003eauxiliary voltages\u003c\/strong\u003e required by the inverter’s control and logic circuits.\u003c\/p\u003e\n\u003cp data-start=\"580\" data-end=\"689\"\u003eIt is a \u003cstrong data-start=\"588\" data-end=\"610\"\u003ecritical component\u003c\/strong\u003e for inverter startup, operational stability, and overall system functionality.\u003c\/p\u003e\n\u003chr data-start=\"691\" data-end=\"694\"\u003e\n\u003ch3 data-start=\"696\" data-end=\"717\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"718\" data-end=\"1057\"\u003e\n\u003cli data-start=\"718\" data-end=\"769\"\u003eDC\/DC conversion from internal power bus (Bulk)\u003c\/li\u003e\n\u003cli data-start=\"770\" data-end=\"842\"\u003eGeneration of stabilized auxiliary voltages (\u003cstrong data-start=\"817\" data-end=\"839\"\u003e+5 V, +12 V, ±15 V\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"843\" data-end=\"900\"\u003eGalvanic isolation between power and control sections\u003c\/li\u003e\n\u003cli data-start=\"901\" data-end=\"959\"\u003ePower supply for CPU, DSP, drivers, and logic circuits\u003c\/li\u003e\n\u003cli data-start=\"960\" data-end=\"1006\"\u003eEMI filtering and electrical stabilization\u003c\/li\u003e\n\u003cli data-start=\"1007\" data-end=\"1057\"\u003eSupport for inverter startup (startup circuit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1059\" data-end=\"1062\"\u003e\n\u003ch3 data-start=\"1064\" data-end=\"1089\"\u003e🔌 Technical Features\u003c\/h3\u003e\n\u003cul data-start=\"1090\" data-end=\"1352\"\u003e\n\u003cli data-start=\"1090\" data-end=\"1135\"\u003eManufacturer: \u003cstrong data-start=\"1106\" data-end=\"1133\"\u003eABB \/ Power-One \/ FIMER\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1136\" data-end=\"1191\"\u003eApplication: \u003cstrong data-start=\"1151\" data-end=\"1189\"\u003eThree-phase photovoltaic inverters\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1192\" data-end=\"1238\"\u003eCompatible series: \u003cstrong data-start=\"1213\" data-end=\"1236\"\u003eTRIO 20.0 \/ 27.6 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1239\" data-end=\"1267\"\u003eBoard revision: \u003cstrong data-start=\"1257\" data-end=\"1265\"\u003e3M22\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1268\" data-end=\"1317\"\u003eTechnology: \u003cstrong data-start=\"1282\" data-end=\"1315\"\u003eSwitching Power Supply (SMPS)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1352\"\u003eCompliance: \u003cstrong data-start=\"1332\" data-end=\"1350\"\u003eRoHS (Pb-Free)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1354\" data-end=\"1372\"\u003e\u003cstrong data-start=\"1354\" data-end=\"1372\"\u003eMain Sections:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1373\" data-end=\"1507\"\u003e\n\u003cli data-start=\"1373\" data-end=\"1418\"\u003eHigh-frequency switching conversion stage\u003c\/li\u003e\n\u003cli data-start=\"1419\" data-end=\"1453\"\u003eShielded isolation transformer\u003c\/li\u003e\n\u003cli data-start=\"1454\" data-end=\"1480\"\u003ePWM regulation circuit\u003c\/li\u003e\n\u003cli data-start=\"1481\" data-end=\"1507\"\u003eEMI and output filters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1509\" data-end=\"1525\"\u003e\u003cstrong data-start=\"1509\" data-end=\"1525\"\u003eConnections:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1526\" data-end=\"1637\"\u003e\n\u003cli data-start=\"1526\" data-end=\"1564\"\u003eInput from DC bus (\u003cstrong data-start=\"1547\" data-end=\"1561\"\u003eBulk \/ GRP\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1565\" data-end=\"1607\"\u003eConnectors to logic and control boards\u003c\/li\u003e\n\u003cli data-start=\"1608\" data-end=\"1637\"\u003eAuxiliary voltage outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1639\" data-end=\"1642\"\u003e\n\u003ch3 data-start=\"1644\" data-end=\"1666\"\u003e🔧 Main Components\u003c\/h3\u003e\n\u003cul data-start=\"1667\" data-end=\"1866\"\u003e\n\u003cli data-start=\"1667\" data-end=\"1707\"\u003eHigh-frequency switching transformer\u003c\/li\u003e\n\u003cli data-start=\"1708\" data-end=\"1737\"\u003eInductors and EMI filters\u003c\/li\u003e\n\u003cli data-start=\"1738\" data-end=\"1780\"\u003ePower MOSFETs and switching regulators\u003c\/li\u003e\n\u003cli data-start=\"1781\" data-end=\"1817\"\u003eElectrolytic and film capacitors\u003c\/li\u003e\n\u003cli data-start=\"1818\" data-end=\"1837\"\u003ePWM control ICs\u003c\/li\u003e\n\u003cli data-start=\"1838\" data-end=\"1866\"\u003ePrecision SMD components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1868\" data-end=\"1871\"\u003e\n\u003ch3 data-start=\"1873\" data-end=\"1904\"\u003e🌐 Role within the Inverter\u003c\/h3\u003e\n\u003cp data-start=\"1906\" data-end=\"1953\"\u003eThis board is essential for inverter operation:\u003c\/p\u003e\n\u003cul data-start=\"1954\" data-end=\"2131\"\u003e\n\u003cli data-start=\"1954\" data-end=\"1997\"\u003eSupplies power to all electronic boards\u003c\/li\u003e\n\u003cli data-start=\"1998\" data-end=\"2040\"\u003eEnsures stability of internal voltages\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2074\"\u003eEnables proper system startup\u003c\/li\u003e\n\u003cli data-start=\"2075\" data-end=\"2131\"\u003eProtects circuits from disturbances and fluctuations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2133\" data-end=\"2226\"\u003e👉 In Aurora \/ FIMER inverters, the power supply module is fundamental for the entire system.\u003c\/p\u003e\n\u003chr data-start=\"2228\" data-end=\"2231\"\u003e\n\u003ch3 data-start=\"2233\" data-end=\"2261\"\u003e⚠️ Typical Issues Solved\u003c\/h3\u003e\n\u003cul data-start=\"2262\" data-end=\"2447\"\u003e\n\u003cli data-start=\"2262\" data-end=\"2289\"\u003eInverter completely off\u003c\/li\u003e\n\u003cli data-start=\"2290\" data-end=\"2323\"\u003eNo startup \/ power-on failure\u003c\/li\u003e\n\u003cli data-start=\"2324\" data-end=\"2355\"\u003eNo display or communication\u003c\/li\u003e\n\u003cli data-start=\"2356\" data-end=\"2383\"\u003eGeneric internal errors\u003c\/li\u003e\n\u003cli data-start=\"2384\" data-end=\"2414\"\u003eControl board power faults\u003c\/li\u003e\n\u003cli data-start=\"2415\" data-end=\"2447\"\u003eRandom shutdowns or restarts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2449\" data-end=\"2452\"\u003e\n\u003ch3 data-start=\"2454\" data-end=\"2476\"\u003e⚠️ Common Failures\u003c\/h3\u003e\n\u003cul data-start=\"2477\" data-end=\"2673\"\u003e\n\u003cli data-start=\"2477\" data-end=\"2511\"\u003eDegraded or swollen capacitors\u003c\/li\u003e\n\u003cli data-start=\"2512\" data-end=\"2540\"\u003eFaulty switching MOSFETs\u003c\/li\u003e\n\u003cli data-start=\"2541\" data-end=\"2574\"\u003eDamaged switching transformer\u003c\/li\u003e\n\u003cli data-start=\"2575\" data-end=\"2613\"\u003eMalfunctioning PWM control circuit\u003c\/li\u003e\n\u003cli data-start=\"2614\" data-end=\"2641\"\u003eMissing output voltages\u003c\/li\u003e\n\u003cli data-start=\"2642\" data-end=\"2673\"\u003eUnstable power supply lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2675\" data-end=\"2678\"\u003e\n\u003ch3 data-start=\"2680\" data-end=\"2700\"\u003e🏭 Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"2701\" data-end=\"2845\"\u003e\n\u003cli data-start=\"2701\" data-end=\"2732\"\u003eABB Aurora \u003cstrong data-start=\"2714\" data-end=\"2730\"\u003eTRIO-20.0-TL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2733\" data-end=\"2764\"\u003eABB Aurora \u003cstrong data-start=\"2746\" data-end=\"2762\"\u003eTRIO-27.6-TL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2765\" data-end=\"2797\"\u003eFIMER TRIO equivalent models\u003c\/li\u003e\n\u003cli data-start=\"2798\" data-end=\"2845\"\u003eIndustrial and commercial inverter versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2847\" data-end=\"2850\"\u003e\n\u003ch3 data-start=\"2852\" data-end=\"2871\"\u003e📊 Applications\u003c\/h3\u003e\n\u003cul data-start=\"2872\" data-end=\"3028\"\u003e\n\u003cli data-start=\"2872\" data-end=\"2908\"\u003eRepair of photovoltaic inverters\u003c\/li\u003e\n\u003cli data-start=\"2909\" data-end=\"2954\"\u003eReplacement of faulty power supply boards\u003c\/li\u003e\n\u003cli data-start=\"2955\" data-end=\"2995\"\u003eMaintenance of industrial PV systems\u003c\/li\u003e\n\u003cli data-start=\"2996\" data-end=\"3028\"\u003eElectronic fault diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53789897228621,"sku":null,"price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5511.jpg?v=1777303309"},{"product_id":"enerpoint-aluminum-end-clamp-38-mm-for-g-e-h-profiles-spring-loaded-pv-module-mounting-clamp-made-in-italy-pack-of-10","title":"Enerpoint Aluminum End Clamp 38 mm for G, E \u0026 H Profiles – Spring Loaded PV Module Mounting Clamp | Made in Italy | Pack of 10","description":"\u003cp data-start=\"163\" data-end=\"313\"\u003eProfessional \u003cstrong data-start=\"176\" data-end=\"199\"\u003eEnerpoint end clamp\u003c\/strong\u003e designed for the secure mounting of photovoltaic modules on solar structures using \u003cstrong data-start=\"283\" data-end=\"312\"\u003e38 mm G, E and H profiles\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"315\" data-end=\"542\"\u003eManufactured from high-strength aluminum, this mounting clamp offers excellent mechanical durability, lightweight construction, and high resistance to corrosion, making it ideal for long-term outdoor photovoltaic installations.\u003c\/p\u003e\n\u003cp data-start=\"544\" data-end=\"747\"\u003eThe integrated fastening system with screw, spring, and locking plate ensures constant pressure on the solar panel frame, simplifying installation while providing reliable mechanical stability over time.\u003c\/p\u003e\n\u003chr data-start=\"749\" data-end=\"752\"\u003e\n\u003ch3 data-start=\"754\" data-end=\"774\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"776\" data-end=\"1188\"\u003e\n\u003cli data-start=\"776\" data-end=\"814\"\u003eEnd clamp for photovoltaic modules\u003c\/li\u003e\n\u003cli data-start=\"815\" data-end=\"871\"\u003eCompatible with G, E and H mounting profiles (38 mm)\u003c\/li\u003e\n\u003cli data-start=\"872\" data-end=\"913\"\u003eHigh-resistance aluminum construction\u003c\/li\u003e\n\u003cli data-start=\"914\" data-end=\"962\"\u003eCorrosion-resistant for outdoor applications\u003c\/li\u003e\n\u003cli data-start=\"963\" data-end=\"1021\"\u003eSpring-loaded fastening system for secure installation\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1055\"\u003eQuick and stable panel fixing\u003c\/li\u003e\n\u003cli data-start=\"1056\" data-end=\"1110\"\u003eSuitable for residential and industrial PV systems\u003c\/li\u003e\n\u003cli data-start=\"1111\" data-end=\"1141\"\u003eOriginal Enerpoint product\u003c\/li\u003e\n\u003cli data-start=\"1142\" data-end=\"1159\"\u003eMade in Italy\u003c\/li\u003e\n\u003cli data-start=\"1160\" data-end=\"1188\"\u003ePack quantity: 10 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1190\" data-end=\"1193\"\u003e\n\u003ch3 data-start=\"1195\" data-end=\"1226\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1228\" data-end=\"1539\"\u003e\n\u003cli data-start=\"1228\" data-end=\"1269\"\u003e\n\u003cstrong data-start=\"1230\" data-end=\"1247\"\u003eProduct Type:\u003c\/strong\u003e PV module end clamp\u003c\/li\u003e\n\u003cli data-start=\"1270\" data-end=\"1296\"\u003e\n\u003cstrong data-start=\"1272\" data-end=\"1285\"\u003eMaterial:\u003c\/strong\u003e Aluminum\u003c\/li\u003e\n\u003cli data-start=\"1297\" data-end=\"1346\"\u003e\n\u003cstrong data-start=\"1299\" data-end=\"1325\"\u003eProfile Compatibility:\u003c\/strong\u003e G \/ E \/ H profiles\u003c\/li\u003e\n\u003cli data-start=\"1347\" data-end=\"1374\"\u003e\n\u003cstrong data-start=\"1349\" data-end=\"1366\"\u003eProfile Size:\u003c\/strong\u003e 38 mm\u003c\/li\u003e\n\u003cli data-start=\"1375\" data-end=\"1428\"\u003e\n\u003cstrong data-start=\"1377\" data-end=\"1395\"\u003eFixing System:\u003c\/strong\u003e Screw + spring + locking plate\u003c\/li\u003e\n\u003cli data-start=\"1429\" data-end=\"1485\"\u003e\n\u003cstrong data-start=\"1431\" data-end=\"1447\"\u003eApplication:\u003c\/strong\u003e Solar photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1486\" data-end=\"1539\"\u003e\n\u003cstrong data-start=\"1488\" data-end=\"1505\"\u003eInstallation:\u003c\/strong\u003e Outdoor \/ rooftop PV structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1541\" data-end=\"1544\"\u003e\n\u003ch3 data-start=\"1546\" data-end=\"1565\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1567\" data-end=\"1731\"\u003e\n\u003cli data-start=\"1567\" data-end=\"1603\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1604\" data-end=\"1653\"\u003eCommercial and industrial solar installations\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1691\"\u003eRooftop solar mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1692\" data-end=\"1731\"\u003eGround-mounted photovoltaic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1733\" data-end=\"1736\"\u003e\n\u003ch3 data-start=\"1738\" data-end=\"1754\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1756\" data-end=\"2031\"\u003e✔ Lightweight and durable aluminum construction\u003cbr data-start=\"1803\" data-end=\"1806\"\u003e✔ Excellent weather and corrosion resistance\u003cbr data-start=\"1850\" data-end=\"1853\"\u003e✔ Fast and secure installation\u003cbr data-start=\"1883\" data-end=\"1886\"\u003e✔ Stable clamping pressure over time\u003cbr data-start=\"1922\" data-end=\"1925\"\u003e✔ Compatible with multiple mounting profile types\u003cbr data-start=\"1974\" data-end=\"1977\"\u003e✔ Professional-grade photovoltaic mounting accessory\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53859281633613,"sku":null,"price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5629.jpg?v=1778172773"},{"product_id":"enerpoint-aluminum-end-clamp-50-mm-for-g-e-h-profiles-pv-module-mounting-bracket-made-in-italy-pack-of-16","title":"Enerpoint Aluminum End Clamp 50 mm for G, E \u0026 H Profiles – PV Module Mounting Bracket | Made in Italy | Pack of 16","description":"\u003cp data-start=\"151\" data-end=\"309\"\u003eProfessional \u003cstrong data-start=\"164\" data-end=\"195\"\u003eEnerpoint end clamp bracket\u003c\/strong\u003e designed for the secure mounting of photovoltaic modules on solar structures using \u003cstrong data-start=\"279\" data-end=\"308\"\u003e50 mm G, E and H profiles\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"311\" data-end=\"542\"\u003eManufactured from high-strength aluminum, this mounting bracket provides excellent structural rigidity, lightweight construction, and superior corrosion resistance, ensuring long-term reliability even in harsh outdoor environments.\u003c\/p\u003e\n\u003cp data-start=\"544\" data-end=\"707\"\u003eIts specially shaped profile allows stable anchoring of photovoltaic panels, simplifying installation while improving the mechanical safety of the mounting system.\u003c\/p\u003e\n\u003cp data-start=\"709\" data-end=\"786\"\u003eIdeal for residential, commercial, and industrial photovoltaic installations.\u003c\/p\u003e\n\u003chr data-start=\"788\" data-end=\"791\"\u003e\n\u003ch3 data-start=\"793\" data-end=\"813\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"815\" data-end=\"1193\"\u003e\n\u003cli data-start=\"815\" data-end=\"861\"\u003eEnd clamp bracket for photovoltaic modules\u003c\/li\u003e\n\u003cli data-start=\"862\" data-end=\"918\"\u003eCompatible with G, E and H mounting profiles (50 mm)\u003c\/li\u003e\n\u003cli data-start=\"919\" data-end=\"958\"\u003eHigh-strength aluminum construction\u003c\/li\u003e\n\u003cli data-start=\"959\" data-end=\"994\"\u003eWeather and corrosion resistant\u003c\/li\u003e\n\u003cli data-start=\"995\" data-end=\"1031\"\u003eLightweight yet robust structure\u003c\/li\u003e\n\u003cli data-start=\"1032\" data-end=\"1064\"\u003eFast and secure installation\u003c\/li\u003e\n\u003cli data-start=\"1065\" data-end=\"1115\"\u003eSuitable for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1116\" data-end=\"1146\"\u003eOriginal Enerpoint product\u003c\/li\u003e\n\u003cli data-start=\"1147\" data-end=\"1164\"\u003eMade in Italy\u003c\/li\u003e\n\u003cli data-start=\"1165\" data-end=\"1193\"\u003ePack quantity: 16 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1195\" data-end=\"1198\"\u003e\n\u003ch3 data-start=\"1200\" data-end=\"1231\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1233\" data-end=\"1518\"\u003e\n\u003cli data-start=\"1233\" data-end=\"1293\"\u003e\n\u003cstrong data-start=\"1235\" data-end=\"1252\"\u003eProduct Type:\u003c\/strong\u003e PV module end clamp \/ mounting bracket\u003c\/li\u003e\n\u003cli data-start=\"1294\" data-end=\"1320\"\u003e\n\u003cstrong data-start=\"1296\" data-end=\"1309\"\u003eMaterial:\u003c\/strong\u003e Aluminum\u003c\/li\u003e\n\u003cli data-start=\"1321\" data-end=\"1370\"\u003e\n\u003cstrong data-start=\"1323\" data-end=\"1349\"\u003eProfile Compatibility:\u003c\/strong\u003e G \/ E \/ H profiles\u003c\/li\u003e\n\u003cli data-start=\"1371\" data-end=\"1398\"\u003e\n\u003cstrong data-start=\"1373\" data-end=\"1390\"\u003eProfile Size:\u003c\/strong\u003e 50 mm\u003c\/li\u003e\n\u003cli data-start=\"1399\" data-end=\"1455\"\u003e\n\u003cstrong data-start=\"1401\" data-end=\"1417\"\u003eApplication:\u003c\/strong\u003e Solar photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1456\" data-end=\"1518\"\u003e\n\u003cstrong data-start=\"1458\" data-end=\"1475\"\u003eInstallation:\u003c\/strong\u003e Rooftop and ground-mounted PV structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1520\" data-end=\"1523\"\u003e\n\u003ch3 data-start=\"1525\" data-end=\"1544\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1546\" data-end=\"1688\"\u003e\n\u003cli data-start=\"1546\" data-end=\"1581\"\u003eResidential solar installations\u003c\/li\u003e\n\u003cli data-start=\"1582\" data-end=\"1617\"\u003eCommercial photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1618\" data-end=\"1655\"\u003eIndustrial PV mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1656\" data-end=\"1688\"\u003eOutdoor solar energy systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1690\" data-end=\"1693\"\u003e\n\u003ch3 data-start=\"1695\" data-end=\"1711\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1713\" data-end=\"1956\"\u003e✔ Durable and lightweight aluminum design\u003cbr data-start=\"1754\" data-end=\"1757\"\u003e✔ High corrosion resistance for outdoor use\u003cbr data-start=\"1800\" data-end=\"1803\"\u003e✔ Secure and stable panel fastening\u003cbr data-start=\"1838\" data-end=\"1841\"\u003e✔ Simplified installation process\u003cbr data-start=\"1874\" data-end=\"1877\"\u003e✔ Suitable for professional PV mounting systems\u003cbr data-start=\"1924\" data-end=\"1927\"\u003e✔ Long operational lifespan\u003c\/p\u003e\n\u003chr data-start=\"1958\" data-end=\"1961\"\u003e\n\u003ch3 data-start=\"1963\" data-end=\"1986\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"1988\" data-end=\"2032\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"1988\" data-end=\"2032\" data-is-last-node=\"\"\u003e16 × Enerpoint aluminum end clamp brackets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53859422470477,"sku":null,"price":6.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5633.jpg?v=1778176397"},{"product_id":"enerpoint-stainless-steel-end-clamp-38-mm-for-f-profiles-pv-module-mounting-clamp-with-spring-made-in-italy-pack-of-10","title":"Enerpoint Stainless Steel End Clamp 38 mm for F Profiles – PV Module Mounting Clamp with Spring | Made in Italy | Pack of 10","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"bd0b779d-6fbe-497c-9089-c231fc27d120\" data-testid=\"conversation-turn-162\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"d49fa280-bc1d-421c-8256-0a0945a89e5d\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"161\" data-end=\"307\"\u003eProfessional \u003cstrong data-start=\"174\" data-end=\"197\"\u003eEnerpoint end clamp\u003c\/strong\u003e designed for the secure mounting of photovoltaic modules on solar structures using \u003cstrong data-start=\"281\" data-end=\"306\"\u003e38 mm F-type profiles\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"309\" data-end=\"536\"\u003eManufactured from high-strength stainless steel, this clamp provides excellent mechanical durability, superior corrosion resistance, and long-term reliability even in demanding outdoor environments and harsh weather conditions.\u003c\/p\u003e\n\u003cp data-start=\"538\" data-end=\"751\"\u003eThe complete fastening system with screw, spring, and locking plate ensures stable clamping pressure on the solar panel frame, simplifying installation and maintenance operations while improving mechanical safety.\u003c\/p\u003e\n\u003chr data-start=\"753\" data-end=\"756\"\u003e\n\u003ch3 data-start=\"758\" data-end=\"778\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"780\" data-end=\"1160\"\u003e\n\u003cli data-start=\"780\" data-end=\"818\"\u003eEnd clamp for photovoltaic modules\u003c\/li\u003e\n\u003cli data-start=\"819\" data-end=\"855\"\u003eCompatible with 38 mm F profiles\u003c\/li\u003e\n\u003cli data-start=\"856\" data-end=\"902\"\u003eHigh-strength stainless steel construction\u003c\/li\u003e\n\u003cli data-start=\"903\" data-end=\"952\"\u003eCorrosion-resistant for outdoor installations\u003c\/li\u003e\n\u003cli data-start=\"953\" data-end=\"987\"\u003eSpring-loaded fastening system\u003c\/li\u003e\n\u003cli data-start=\"988\" data-end=\"1031\"\u003eStrong and durable mechanical structure\u003c\/li\u003e\n\u003cli data-start=\"1032\" data-end=\"1082\"\u003eSuitable for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1083\" data-end=\"1113\"\u003eOriginal Enerpoint product\u003c\/li\u003e\n\u003cli data-start=\"1114\" data-end=\"1131\"\u003eMade in Italy\u003c\/li\u003e\n\u003cli data-start=\"1132\" data-end=\"1160\"\u003ePack quantity: 10 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1162\" data-end=\"1165\"\u003e\n\u003ch3 data-start=\"1167\" data-end=\"1198\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1200\" data-end=\"1500\"\u003e\n\u003cli data-start=\"1200\" data-end=\"1241\"\u003e\n\u003cstrong data-start=\"1202\" data-end=\"1219\"\u003eProduct Type:\u003c\/strong\u003e PV module end clamp\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1275\"\u003e\n\u003cstrong data-start=\"1244\" data-end=\"1257\"\u003eMaterial:\u003c\/strong\u003e Stainless steel\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1317\"\u003e\n\u003cstrong data-start=\"1278\" data-end=\"1304\"\u003eProfile Compatibility:\u003c\/strong\u003e F profiles\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1345\"\u003e\n\u003cstrong data-start=\"1320\" data-end=\"1337\"\u003eProfile Size:\u003c\/strong\u003e 38 mm\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1399\"\u003e\n\u003cstrong data-start=\"1348\" data-end=\"1366\"\u003eFixing System:\u003c\/strong\u003e Screw + spring + locking plate\u003c\/li\u003e\n\u003cli data-start=\"1400\" data-end=\"1456\"\u003e\n\u003cstrong data-start=\"1402\" data-end=\"1418\"\u003eApplication:\u003c\/strong\u003e Solar photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1457\" data-end=\"1500\"\u003e\n\u003cstrong data-start=\"1459\" data-end=\"1476\"\u003eInstallation:\u003c\/strong\u003e Outdoor PV structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1502\" data-end=\"1505\"\u003e\n\u003ch3 data-start=\"1507\" data-end=\"1526\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1528\" data-end=\"1682\"\u003e\n\u003cli data-start=\"1528\" data-end=\"1564\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1565\" data-end=\"1599\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-start=\"1600\" data-end=\"1637\"\u003eIndustrial PV mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1682\"\u003eRooftop and ground-mounted solar systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1684\" data-end=\"1687\"\u003e\n\u003ch3 data-start=\"1689\" data-end=\"1705\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1707\" data-end=\"1937\"\u003e✔ Excellent corrosion resistance\u003cbr data-start=\"1739\" data-end=\"1742\"\u003e✔ Robust stainless steel construction\u003cbr data-start=\"1779\" data-end=\"1782\"\u003e✔ Stable and secure panel fastening\u003cbr data-start=\"1817\" data-end=\"1820\"\u003e✔ Constant clamping pressure over time\u003cbr data-start=\"1858\" data-end=\"1861\"\u003e✔ Easy installation and maintenance\u003cbr data-start=\"1896\" data-end=\"1899\"\u003e✔ Designed for long-term outdoor use\u003c\/p\u003e\n\u003chr data-start=\"1939\" data-end=\"1942\"\u003e\n\u003ch3 data-start=\"1944\" data-end=\"1967\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"1969\" data-end=\"2031\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"1969\" data-end=\"2031\" data-is-last-node=\"\"\u003e10 × Enerpoint stainless steel end clamps with spring system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53859461333325,"sku":null,"price":24.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5638.jpg?v=1778176985"},{"product_id":"enerpoint-adjustable-stainless-steel-304-bracket-with-hammer-head-bolt-flanged-nut-pv-mounting-support-bracket-made-in-italy-pack-of-4","title":"Enerpoint Adjustable Stainless Steel 304 Bracket with Hammer Head Bolt \u0026 Flanged Nut – PV Mounting Support Bracket | Made in Italy | Pack of 4","description":"\u003cp data-start=\"179\" data-end=\"309\"\u003eProfessional \u003cstrong data-start=\"192\" data-end=\"233\"\u003eEnerpoint adjustable mounting bracket\u003c\/strong\u003e designed for the fastening and support of photovoltaic mounting structures.\u003c\/p\u003e\n\u003cp data-start=\"311\" data-end=\"559\"\u003eManufactured from \u003cstrong data-start=\"329\" data-end=\"357\"\u003eAISI 304 stainless steel\u003c\/strong\u003e, this bracket provides excellent mechanical strength, long service life, and superior resistance to corrosion and harsh weather conditions, making it ideal for professional outdoor solar installations.\u003c\/p\u003e\n\u003cp data-start=\"561\" data-end=\"718\"\u003eThe kit includes a \u003cstrong data-start=\"580\" data-end=\"600\"\u003ehammer head bolt\u003c\/strong\u003e and \u003cstrong data-start=\"605\" data-end=\"620\"\u003eflanged nut\u003c\/strong\u003e for quick, secure, and stable installation on photovoltaic mounting rails and support structures.\u003c\/p\u003e\n\u003cp data-start=\"720\" data-end=\"823\"\u003eIts adjustable design allows precise alignment and positioning during photovoltaic module installation.\u003c\/p\u003e\n\u003chr data-start=\"825\" data-end=\"828\"\u003e\n\u003ch3 data-start=\"830\" data-end=\"850\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"852\" data-end=\"1338\"\u003e\n\u003cli data-start=\"852\" data-end=\"911\"\u003eAdjustable bracket for photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"912\" data-end=\"956\"\u003eMade from stainless steel 304 (AISI 304)\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"1002\"\u003eIncludes hammer head bolt and flanged nut\u003c\/li\u003e\n\u003cli data-start=\"1003\" data-end=\"1049\"\u003eExcellent corrosion and weather resistance\u003c\/li\u003e\n\u003cli data-start=\"1050\" data-end=\"1085\"\u003eStrong and durable construction\u003c\/li\u003e\n\u003cli data-start=\"1086\" data-end=\"1135\"\u003eAdjustable for precise installation alignment\u003c\/li\u003e\n\u003cli data-start=\"1136\" data-end=\"1171\"\u003eFast and secure mounting system\u003c\/li\u003e\n\u003cli data-start=\"1172\" data-end=\"1222\"\u003eSuitable for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1223\" data-end=\"1253\"\u003eOriginal Enerpoint product\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1292\"\u003eProduct code: \u003cstrong data-start=\"1270\" data-end=\"1290\"\u003eEP-04E021-SRI-11\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1293\" data-end=\"1310\"\u003eMade in Italy\u003c\/li\u003e\n\u003cli data-start=\"1311\" data-end=\"1338\"\u003ePack quantity: 4 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1340\" data-end=\"1343\"\u003e\n\u003ch3 data-start=\"1345\" data-end=\"1376\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1378\" data-end=\"1630\"\u003e\n\u003cli data-start=\"1378\" data-end=\"1430\"\u003e\n\u003cstrong data-start=\"1380\" data-end=\"1397\"\u003eProduct Type:\u003c\/strong\u003e Adjustable PV mounting bracket\u003c\/li\u003e\n\u003cli data-start=\"1431\" data-end=\"1468\"\u003e\n\u003cstrong data-start=\"1433\" data-end=\"1446\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel 304\u003c\/li\u003e\n\u003cli data-start=\"1469\" data-end=\"1524\"\u003e\n\u003cstrong data-start=\"1471\" data-end=\"1491\"\u003eFixing Hardware:\u003c\/strong\u003e Hammer head bolt + flanged nut\u003c\/li\u003e\n\u003cli data-start=\"1525\" data-end=\"1578\"\u003e\n\u003cstrong data-start=\"1527\" data-end=\"1543\"\u003eApplication:\u003c\/strong\u003e Photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1579\" data-end=\"1630\"\u003e\n\u003cstrong data-start=\"1581\" data-end=\"1598\"\u003eInstallation:\u003c\/strong\u003e Outdoor solar support systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1632\" data-end=\"1635\"\u003e\n\u003ch3 data-start=\"1637\" data-end=\"1656\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1658\" data-end=\"1812\"\u003e\n\u003cli data-start=\"1658\" data-end=\"1694\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1695\" data-end=\"1729\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-start=\"1730\" data-end=\"1767\"\u003eIndustrial PV mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1768\" data-end=\"1812\"\u003eRooftop and ground-mounted solar systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1814\" data-end=\"1817\"\u003e\n\u003ch3 data-start=\"1819\" data-end=\"1835\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1837\" data-end=\"2099\"\u003e✔ High corrosion resistance for outdoor use\u003cbr data-start=\"1880\" data-end=\"1883\"\u003e✔ Durable stainless steel construction\u003cbr data-start=\"1921\" data-end=\"1924\"\u003e✔ Adjustable positioning for precise installation\u003cbr data-start=\"1973\" data-end=\"1976\"\u003e✔ Secure and stable fastening system\u003cbr data-start=\"2012\" data-end=\"2015\"\u003e✔ Long operational lifespan\u003cbr data-start=\"2042\" data-end=\"2045\"\u003e✔ Professional-grade photovoltaic mounting accessory\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53864412807501,"sku":null,"price":60.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5642.jpg?v=1778253849"},{"product_id":"enerpoint-flat-fixed-stainless-steel-304-bracket-with-defz-m8-tma-8x20-pv-mounting-support-bracket-made-in-italy-pack-of-8","title":"Enerpoint Flat Fixed Stainless Steel 304 Bracket with DEFZ M8 \u0026 TMA 8x20 – PV Mounting Support Bracket | Made in Italy | Pack of 8","description":"\u003cp data-start=\"167\" data-end=\"311\"\u003eProfessional \u003cstrong data-start=\"180\" data-end=\"212\"\u003eEnerpoint flat fixed bracket\u003c\/strong\u003e designed for the secure fastening of photovoltaic mounting structures and solar system components.\u003c\/p\u003e\n\u003cp data-start=\"313\" data-end=\"563\"\u003eManufactured from \u003cstrong data-start=\"331\" data-end=\"359\"\u003eAISI 304 stainless steel\u003c\/strong\u003e, this bracket ensures high mechanical strength, long service life, and excellent resistance to corrosion and harsh weather conditions, making it ideal for professional outdoor photovoltaic installations.\u003c\/p\u003e\n\u003cp data-start=\"565\" data-end=\"729\"\u003eThe kit includes \u003cstrong data-start=\"582\" data-end=\"593\"\u003eDEFZ M8\u003c\/strong\u003e and \u003cstrong data-start=\"598\" data-end=\"610\"\u003eTMA 8x20\u003c\/strong\u003e fixing accessories, providing a practical, stable, and reliable mounting solution for photovoltaic support structures.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"851\"\u003eIts flat reinforced design allows uniform load distribution and improved structural stability of the solar installation.\u003c\/p\u003e\n\u003chr data-start=\"853\" data-end=\"856\"\u003e\n\u003ch3 data-start=\"858\" data-end=\"878\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"880\" data-end=\"1372\"\u003e\n\u003cli data-start=\"880\" data-end=\"939\"\u003eFlat fixed bracket for photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"940\" data-end=\"984\"\u003eMade from stainless steel 304 (AISI 304)\u003c\/li\u003e\n\u003cli data-start=\"985\" data-end=\"1034\"\u003eIncludes DEFZ M8 and TMA 8x20 fixing hardware\u003c\/li\u003e\n\u003cli data-start=\"1035\" data-end=\"1081\"\u003eExcellent corrosion and weather resistance\u003c\/li\u003e\n\u003cli data-start=\"1082\" data-end=\"1117\"\u003eStrong and durable construction\u003c\/li\u003e\n\u003cli data-start=\"1118\" data-end=\"1150\"\u003eEasy and secure installation\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1205\"\u003eOptimized load distribution for enhanced stability\u003c\/li\u003e\n\u003cli data-start=\"1206\" data-end=\"1256\"\u003eSuitable for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1257\" data-end=\"1287\"\u003eOriginal Enerpoint product\u003c\/li\u003e\n\u003cli data-start=\"1288\" data-end=\"1326\"\u003eProduct code: \u003cstrong data-start=\"1304\" data-end=\"1324\"\u003eEP-04E021-SPI-11\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1327\" data-end=\"1344\"\u003eMade in Italy\u003c\/li\u003e\n\u003cli data-start=\"1345\" data-end=\"1372\"\u003ePack quantity: 8 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1374\" data-end=\"1377\"\u003e\n\u003ch3 data-start=\"1379\" data-end=\"1410\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1412\" data-end=\"1654\"\u003e\n\u003cli data-start=\"1412\" data-end=\"1464\"\u003e\n\u003cstrong data-start=\"1414\" data-end=\"1431\"\u003eProduct Type:\u003c\/strong\u003e Fixed flat PV mounting bracket\u003c\/li\u003e\n\u003cli data-start=\"1465\" data-end=\"1502\"\u003e\n\u003cstrong data-start=\"1467\" data-end=\"1480\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel 304\u003c\/li\u003e\n\u003cli data-start=\"1503\" data-end=\"1548\"\u003e\n\u003cstrong data-start=\"1505\" data-end=\"1527\"\u003eIncluded Hardware:\u003c\/strong\u003e DEFZ M8 + TMA 8x20\u003c\/li\u003e\n\u003cli data-start=\"1549\" data-end=\"1602\"\u003e\n\u003cstrong data-start=\"1551\" data-end=\"1567\"\u003eApplication:\u003c\/strong\u003e Photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1603\" data-end=\"1654\"\u003e\n\u003cstrong data-start=\"1605\" data-end=\"1622\"\u003eInstallation:\u003c\/strong\u003e Outdoor solar support systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1656\" data-end=\"1659\"\u003e\n\u003ch3 data-start=\"1661\" data-end=\"1680\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1682\" data-end=\"1836\"\u003e\n\u003cli data-start=\"1682\" data-end=\"1718\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1719\" data-end=\"1753\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-start=\"1754\" data-end=\"1791\"\u003eIndustrial PV mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1792\" data-end=\"1836\"\u003eRooftop and ground-mounted solar systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1838\" data-end=\"1841\"\u003e\n\u003ch3 data-start=\"1843\" data-end=\"1859\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1861\" data-end=\"2144\"\u003e✔ Excellent corrosion resistance for outdoor use\u003cbr data-start=\"1909\" data-end=\"1912\"\u003e✔ Durable stainless steel construction\u003cbr data-start=\"1950\" data-end=\"1953\"\u003e✔ Stable and secure fastening system\u003cbr data-start=\"1989\" data-end=\"1992\"\u003e✔ Uniform load distribution for improved structural support\u003cbr data-start=\"2051\" data-end=\"2054\"\u003e✔ Easy installation and maintenance\u003cbr data-start=\"2089\" data-end=\"2092\"\u003e✔ Designed for long-term photovoltaic applications\u003c\/p\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"4059c710-a58c-45c9-a856-a8a316d4e810\" data-testid=\"conversation-turn-166\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"4059c710-a58c-45c9-a856-a8a316d4e810\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cul data-start=\"2176\" data-end=\"2267\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"2176\" data-end=\"2219\"\u003e8 × Flat fixed stainless steel brackets\u003c\/li\u003e\n\u003cli data-start=\"2220\" data-end=\"2267\" data-is-last-node=\"\"\u003eDEFZ M8 and TMA 8x20 fixing hardware included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53864450949453,"sku":null,"price":24.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5646.jpg?v=1778254232"},{"product_id":"enerpoint-double-thread-screw-f10-l350-mm-stainless-steel-304-for-wood-pv-mounting-fastener-made-in-italy","title":"Enerpoint Double Thread Screw F10 L350 mm Stainless Steel 304 for Wood – PV Mounting Fastener | Made in Italy |","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"0ad3b7fe-43ec-4701-93ba-1e9d02678b32\" data-turn-id-container=\"0ad3b7fe-43ec-4701-93ba-1e9d02678b32\" data-testid=\"conversation-turn-174\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"0ad3b7fe-43ec-4701-93ba-1e9d02678b32\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"159\" data-end=\"295\"\u003eProfessional \u003cstrong data-start=\"172\" data-end=\"205\"\u003eEnerpoint double thread screw\u003c\/strong\u003e designed for the secure fastening of photovoltaic mounting structures on wooden supports.\u003c\/p\u003e\n\u003cp data-start=\"297\" data-end=\"558\"\u003eManufactured from \u003cstrong data-start=\"315\" data-end=\"343\"\u003eAISI 304 stainless steel\u003c\/strong\u003e, this mounting fastener provides excellent mechanical strength, long operational life, and superior resistance to corrosion and weather exposure, making it ideal for professional outdoor photovoltaic installations.\u003c\/p\u003e\n\u003cp data-start=\"560\" data-end=\"725\"\u003eIts double-thread design ensures stable and reliable anchoring of photovoltaic support structures, improving installation safety and long-term structural durability.\u003c\/p\u003e\n\u003cp data-start=\"727\" data-end=\"813\"\u003eSupplied complete with nuts and washers for quick, practical, and secure installation.\u003c\/p\u003e\n\u003chr data-start=\"815\" data-end=\"818\"\u003e\n\u003ch3 data-start=\"820\" data-end=\"840\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"842\" data-end=\"1300\"\u003e\n\u003cli data-start=\"842\" data-end=\"902\"\u003eDouble thread screw for photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"903\" data-end=\"938\"\u003eSuitable for wood installations\u003c\/li\u003e\n\u003cli data-start=\"939\" data-end=\"952\"\u003eSize: F10\u003c\/li\u003e\n\u003cli data-start=\"953\" data-end=\"971\"\u003eLength: 350 mm\u003c\/li\u003e\n\u003cli data-start=\"972\" data-end=\"1016\"\u003eMade from stainless steel 304 (AISI 304)\u003c\/li\u003e\n\u003cli data-start=\"1017\" data-end=\"1063\"\u003eExcellent corrosion and weather resistance\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1102\"\u003eStrong and secure fastening system\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1132\"\u003eIncludes nuts and washers\u003c\/li\u003e\n\u003cli data-start=\"1133\" data-end=\"1183\"\u003eSuitable for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1184\" data-end=\"1214\"\u003eOriginal Enerpoint product\u003c\/li\u003e\n\u003cli data-start=\"1215\" data-end=\"1253\"\u003eProduct code: \u003cstrong data-start=\"1231\" data-end=\"1251\"\u003eEP-04E021-VLI-04\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1271\"\u003eMade in Italy\u003c\/li\u003e\n\u003cli data-start=\"1272\" data-end=\"1300\"\u003ePack quantity: 25 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1302\" data-end=\"1305\"\u003e\n\u003ch3 data-start=\"1307\" data-end=\"1338\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1340\" data-end=\"1578\"\u003e\n\u003cli data-start=\"1340\" data-end=\"1390\"\u003e\n\u003cstrong data-start=\"1342\" data-end=\"1359\"\u003eProduct Type:\u003c\/strong\u003e Double thread mounting screw\u003c\/li\u003e\n\u003cli data-start=\"1391\" data-end=\"1428\"\u003e\n\u003cstrong data-start=\"1393\" data-end=\"1406\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel 304\u003c\/li\u003e\n\u003cli data-start=\"1429\" data-end=\"1450\"\u003e\n\u003cstrong data-start=\"1431\" data-end=\"1444\"\u003eDiameter:\u003c\/strong\u003e F10\u003c\/li\u003e\n\u003cli data-start=\"1451\" data-end=\"1473\"\u003e\n\u003cstrong data-start=\"1453\" data-end=\"1464\"\u003eLength:\u003c\/strong\u003e 350 mm\u003c\/li\u003e\n\u003cli data-start=\"1474\" data-end=\"1527\"\u003e\n\u003cstrong data-start=\"1476\" data-end=\"1492\"\u003eApplication:\u003c\/strong\u003e PV mounting on wooden structures\u003c\/li\u003e\n\u003cli data-start=\"1528\" data-end=\"1578\"\u003e\n\u003cstrong data-start=\"1530\" data-end=\"1547\"\u003eInstallation:\u003c\/strong\u003e Outdoor photovoltaic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1580\" data-end=\"1583\"\u003e\n\u003ch3 data-start=\"1585\" data-end=\"1604\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1606\" data-end=\"1774\"\u003e\n\u003cli data-start=\"1606\" data-end=\"1659\"\u003eRooftop photovoltaic systems on wooden structures\u003c\/li\u003e\n\u003cli data-start=\"1660\" data-end=\"1695\"\u003eResidential solar installations\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1740\"\u003eCommercial photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1741\" data-end=\"1774\"\u003eOutdoor PV support structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1776\" data-end=\"1779\"\u003e\n\u003ch3 data-start=\"1781\" data-end=\"1797\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1799\" data-end=\"2071\"\u003e✔ High corrosion resistance for outdoor environments\u003cbr data-start=\"1851\" data-end=\"1854\"\u003e✔ Durable stainless steel construction\u003cbr data-start=\"1892\" data-end=\"1895\"\u003e✔ Secure anchoring on wooden supports\u003cbr data-start=\"1932\" data-end=\"1935\"\u003e✔ Reliable long-term mechanical stability\u003cbr data-start=\"1976\" data-end=\"1979\"\u003e✔ Complete fastening kit included\u003cbr data-start=\"2012\" data-end=\"2015\"\u003e✔ Designed for professional photovoltaic installations\u003c\/p\u003e\n\u003chr data-start=\"2073\" data-end=\"2076\"\u003e\n\u003ch3 data-start=\"2078\" data-end=\"2101\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"2103\" data-end=\"2189\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"2103\" data-end=\"2161\"\u003e25 × Double thread stainless steel screws F10 × 350 mm\u003c\/li\u003e\n\u003cli data-start=\"2162\" data-end=\"2189\" data-is-last-node=\"\"\u003eNuts and washers included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53888081002829,"sku":null,"price":42.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5681.jpg?v=1778598316"},{"product_id":"aluminum-internal-rail-splice-connector-for-photovoltaic-mounting-rails-linear-joint-for-solar-panel-support-structures","title":"Aluminum Internal Rail Splice Connector for Photovoltaic Mounting Rails – Linear Joint for Solar Panel Support Structures,Pack of 96","description":"\u003cp data-start=\"158\" data-end=\"316\"\u003eProfessional \u003cstrong data-start=\"171\" data-end=\"207\"\u003einternal linear splice connector\u003c\/strong\u003e designed for the structural connection of aluminum rails and mounting profiles used in photovoltaic systems.\u003c\/p\u003e\n\u003cp data-start=\"318\" data-end=\"533\"\u003eManufactured from high-strength aluminum, this connector allows two mounting rails to be securely joined, ensuring mechanical continuity, structural stability, and precise alignment of photovoltaic support profiles.\u003c\/p\u003e\n\u003cp data-start=\"535\" data-end=\"707\"\u003eIts shaped internal design enables concealed installation inside the rail profile, providing a stable and secure connection without external protrusions or additional bulk.\u003c\/p\u003e\n\u003cp data-start=\"709\" data-end=\"789\"\u003eIdeal for residential, commercial, and industrial photovoltaic mounting systems.\u003c\/p\u003e\n\u003chr data-start=\"791\" data-end=\"794\"\u003e\n\u003ch3 data-start=\"796\" data-end=\"816\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"818\" data-end=\"1249\"\u003e\n\u003cli data-start=\"818\" data-end=\"886\"\u003eInternal linear splice connector for photovoltaic mounting rails\u003c\/li\u003e\n\u003cli data-start=\"887\" data-end=\"947\"\u003eSecure connection of aluminum rails and support profiles\u003c\/li\u003e\n\u003cli data-start=\"948\" data-end=\"987\"\u003eHigh-strength aluminum construction\u003c\/li\u003e\n\u003cli data-start=\"988\" data-end=\"1034\"\u003eExcellent corrosion and weather resistance\u003c\/li\u003e\n\u003cli data-start=\"1035\" data-end=\"1071\"\u003eLightweight yet robust structure\u003c\/li\u003e\n\u003cli data-start=\"1072\" data-end=\"1114\"\u003eConcealed internal installation design\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1156\"\u003eEnsures rail continuity and alignment\u003c\/li\u003e\n\u003cli data-start=\"1157\" data-end=\"1189\"\u003eFast and secure installation\u003c\/li\u003e\n\u003cli data-start=\"1190\" data-end=\"1249\"\u003eSuitable for professional photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1190\" data-end=\"1249\"\u003e\n\u003ch3 data-start=\"0\" data-end=\"28\"\u003e📐 Indicative Dimensions\u003c\/h3\u003e\n\u003cul data-start=\"30\" data-end=\"204\"\u003e\n\u003cli data-start=\"30\" data-end=\"59\"\u003e\n\u003cstrong data-start=\"32\" data-end=\"43\"\u003eLength:\u003c\/strong\u003e approx. 70 mm\u003c\/li\u003e\n\u003cli data-start=\"60\" data-end=\"88\"\u003e\n\u003cstrong data-start=\"62\" data-end=\"72\"\u003eWidth:\u003c\/strong\u003e approx. 35 mm\u003c\/li\u003e\n\u003cli data-start=\"89\" data-end=\"136\"\u003e\n\u003cstrong data-start=\"91\" data-end=\"120\"\u003eProfile height\/thickness:\u003c\/strong\u003e approx. 15 mm\u003c\/li\u003e\n\u003cli data-start=\"137\" data-end=\"204\"\u003e\n\u003cstrong data-start=\"139\" data-end=\"156\"\u003eCentral hole:\u003c\/strong\u003e approximately compatible with M8 bolts\/screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"206\" data-end=\"314\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eDimensions are indicative and may slightly vary depending on the production batch or mounting configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1251\" data-end=\"1254\"\u003e\n\u003ch3 data-start=\"1256\" data-end=\"1287\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1289\" data-end=\"1551\"\u003e\n\u003cli data-start=\"1289\" data-end=\"1341\"\u003e\n\u003cstrong data-start=\"1291\" data-end=\"1308\"\u003eProduct Type:\u003c\/strong\u003e Internal rail splice connector\u003c\/li\u003e\n\u003cli data-start=\"1342\" data-end=\"1382\"\u003e\n\u003cstrong data-start=\"1344\" data-end=\"1357\"\u003eMaterial:\u003c\/strong\u003e High-strength aluminum\u003c\/li\u003e\n\u003cli data-start=\"1383\" data-end=\"1431\"\u003e\n\u003cstrong data-start=\"1385\" data-end=\"1401\"\u003eApplication:\u003c\/strong\u003e PV mounting rail connection\u003c\/li\u003e\n\u003cli data-start=\"1432\" data-end=\"1485\"\u003e\n\u003cstrong data-start=\"1434\" data-end=\"1456\"\u003eInstallation Type:\u003c\/strong\u003e Internal profile insertion\u003c\/li\u003e\n\u003cli data-start=\"1486\" data-end=\"1551\"\u003e\n\u003cstrong data-start=\"1488\" data-end=\"1506\"\u003eCompatibility:\u003c\/strong\u003e Aluminum solar mounting rails and profiles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1553\" data-end=\"1556\"\u003e\n\u003ch3 data-start=\"1558\" data-end=\"1577\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1579\" data-end=\"1733\"\u003e\n\u003cli data-start=\"1579\" data-end=\"1615\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1616\" data-end=\"1650\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-start=\"1651\" data-end=\"1688\"\u003eIndustrial PV mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1689\" data-end=\"1733\"\u003eRooftop and ground-mounted solar systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1735\" data-end=\"1738\"\u003e\n\u003ch3 data-start=\"1740\" data-end=\"1756\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1758\" data-end=\"2040\"\u003e✔ Provides strong structural rail connection\u003cbr data-start=\"1802\" data-end=\"1805\"\u003e✔ Ensures accurate profile alignment\u003cbr data-start=\"1841\" data-end=\"1844\"\u003e✔ Corrosion-resistant aluminum construction\u003cbr data-start=\"1887\" data-end=\"1890\"\u003e✔ Clean and discreet internal mounting design\u003cbr data-start=\"1935\" data-end=\"1938\"\u003e✔ Improves mechanical stability of the PV structure\u003cbr data-start=\"1989\" data-end=\"1992\"\u003e✔ Suitable for long-term outdoor installations\u003c\/p\u003e\n\u003chr data-start=\"2042\" data-end=\"2045\"\u003e\n\u003ch3 data-start=\"2047\" data-end=\"2070\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"2072\" data-end=\"2140\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"2072\" data-end=\"2140\" data-is-last-node=\"\"\u003eAluminum internal splice connector for photovoltaic mounting\u003c\/li\u003e\n\u003cli data-start=\"2072\" data-end=\"2140\" data-is-last-node=\"\"\u003ePack of 96 \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53888087425357,"sku":null,"price":60.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5660.jpg?v=1778598548"},{"product_id":"varista-serrated-blackened-clamp-for-avancis-photovoltaic-modules-pv-mounting-fixing-clip-made-in-germany","title":"Varista Serrated Blackened Clamp for AVANCIS Photovoltaic Modules – PV Mounting Fixing Clip | Made in Germany |","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"aa1fdea6-ff4f-4696-a94c-f59bc1a69f93\" data-turn-id-container=\"aa1fdea6-ff4f-4696-a94c-f59bc1a69f93\" data-testid=\"conversation-turn-178\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"aa1fdea6-ff4f-4696-a94c-f59bc1a69f93\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"160\" data-end=\"308\"\u003eProfessional \u003cstrong data-start=\"173\" data-end=\"208\"\u003eVarista serrated mounting clamp\u003c\/strong\u003e designed for the secure fastening of \u003cstrong data-start=\"246\" data-end=\"278\"\u003eAVANCIS photovoltaic modules\u003c\/strong\u003e on solar mounting structures.\u003c\/p\u003e\n\u003cp data-start=\"310\" data-end=\"514\"\u003eThe special internal serrated design increases grip between the solar module frame and the mounting support, ensuring stable fastening, improved vibration resistance, and long-term mechanical reliability.\u003c\/p\u003e\n\u003cp data-start=\"516\" data-end=\"763\"\u003eManufactured with a durable \u003cstrong data-start=\"544\" data-end=\"579\"\u003eblackened anti-corrosion finish\u003c\/strong\u003e, this clamp provides excellent resistance against wear and environmental exposure, making it ideal for professional residential, commercial, and industrial photovoltaic installations.\u003c\/p\u003e\n\u003chr data-start=\"765\" data-end=\"768\"\u003e\n\u003ch3 data-start=\"770\" data-end=\"790\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"792\" data-end=\"1191\"\u003e\n\u003cli data-start=\"792\" data-end=\"843\"\u003eSerrated clamp for AVANCIS photovoltaic modules\u003c\/li\u003e\n\u003cli data-start=\"844\" data-end=\"893\"\u003eCompatible with photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"894\" data-end=\"937\"\u003eBlackened anti-corrosion surface finish\u003c\/li\u003e\n\u003cli data-start=\"938\" data-end=\"990\"\u003eInternal serration for enhanced panel frame grip\u003c\/li\u003e\n\u003cli data-start=\"991\" data-end=\"1038\"\u003eHigh mechanical stability and holding force\u003c\/li\u003e\n\u003cli data-start=\"1039\" data-end=\"1071\"\u003eFast and secure installation\u003c\/li\u003e\n\u003cli data-start=\"1072\" data-end=\"1122\"\u003eSuitable for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1123\" data-end=\"1141\"\u003eBrand: Varista\u003c\/li\u003e\n\u003cli data-start=\"1142\" data-end=\"1161\"\u003eMade in Germany\u003c\/li\u003e\n\u003cli data-start=\"1162\" data-end=\"1191\"\u003ePack quantity: 100 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1193\" data-end=\"1196\"\u003e\n\u003ch3 data-start=\"1198\" data-end=\"1226\"\u003e📐 Indicative Dimensions\u003c\/h3\u003e\n\u003cul data-start=\"1228\" data-end=\"1410\"\u003e\n\u003cli data-start=\"1228\" data-end=\"1256\"\u003e\n\u003cstrong data-start=\"1230\" data-end=\"1240\"\u003eWidth:\u003c\/strong\u003e approx. 35 mm\u003c\/li\u003e\n\u003cli data-start=\"1257\" data-end=\"1298\"\u003e\n\u003cstrong data-start=\"1259\" data-end=\"1282\"\u003e“U” profile height:\u003c\/strong\u003e approx. 20 mm\u003c\/li\u003e\n\u003cli data-start=\"1299\" data-end=\"1367\"\u003e\n\u003cstrong data-start=\"1301\" data-end=\"1318\"\u003eCentral hole:\u003c\/strong\u003e approximately compatible with M10 bolts\/screws\u003c\/li\u003e\n\u003cli data-start=\"1368\" data-end=\"1410\"\u003e\n\u003cstrong data-start=\"1370\" data-end=\"1393\"\u003eMaterial thickness:\u003c\/strong\u003e approx. 2–4 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1412\" data-end=\"1415\"\u003e\n\u003ch3 data-start=\"1417\" data-end=\"1448\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1450\" data-end=\"1693\"\u003e\n\u003cli data-start=\"1450\" data-end=\"1498\"\u003e\n\u003cstrong data-start=\"1452\" data-end=\"1469\"\u003eProduct Type:\u003c\/strong\u003e Serrated PV mounting clamp\u003c\/li\u003e\n\u003cli data-start=\"1499\" data-end=\"1546\"\u003e\n\u003cstrong data-start=\"1501\" data-end=\"1521\"\u003eMaterial Finish:\u003c\/strong\u003e Blackened steel finish\u003c\/li\u003e\n\u003cli data-start=\"1547\" data-end=\"1598\"\u003e\n\u003cstrong data-start=\"1549\" data-end=\"1567\"\u003eCompatibility:\u003c\/strong\u003e AVANCIS photovoltaic modules\u003c\/li\u003e\n\u003cli data-start=\"1599\" data-end=\"1645\"\u003e\n\u003cstrong data-start=\"1601\" data-end=\"1621\"\u003eMounting System:\u003c\/strong\u003e PV support structures\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1693\"\u003e\n\u003cstrong data-start=\"1648\" data-end=\"1664\"\u003eApplication:\u003c\/strong\u003e Solar panel fixing systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1695\" data-end=\"1698\"\u003e\n\u003ch3 data-start=\"1700\" data-end=\"1719\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1721\" data-end=\"1885\"\u003e\n\u003cli data-start=\"1721\" data-end=\"1757\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1758\" data-end=\"1792\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-start=\"1793\" data-end=\"1837\"\u003eIndustrial photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1838\" data-end=\"1885\"\u003eRooftop and ground-mounted solar structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1887\" data-end=\"1890\"\u003e\n\u003ch3 data-start=\"1892\" data-end=\"1908\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1910\" data-end=\"2191\"\u003e✔ Enhanced grip thanks to serrated internal profile\u003cbr data-start=\"1961\" data-end=\"1964\"\u003e✔ Stable and secure mechanical fastening\u003cbr data-start=\"2004\" data-end=\"2007\"\u003e✔ Resistant to vibration and mechanical stress\u003cbr data-start=\"2053\" data-end=\"2056\"\u003e✔ Anti-corrosion blackened finish\u003cbr data-start=\"2089\" data-end=\"2092\"\u003e✔ Reliable long-term outdoor performance\u003cbr data-start=\"2132\" data-end=\"2135\"\u003e✔ Suitable for professional photovoltaic installations\u003c\/p\u003e\n\u003chr data-start=\"2193\" data-end=\"2196\"\u003e\n\u003ch3 data-start=\"2198\" data-end=\"2221\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"2223\" data-end=\"2263\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"2223\" data-end=\"2263\" data-is-last-node=\"\"\u003e100 × Varista serrated mounting clamps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53888148111693,"sku":null,"price":48.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5664.jpg?v=1778599667"},{"product_id":"aluminum-mini-rail-for-photovoltaic-modules-solar-mounting-support-profile","title":"Aluminum Mini Rail for Photovoltaic Modules – Solar Mounting Support Profile","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"891f7b31-3662-4023-bb14-e3f102bdd565\" data-turn-id-container=\"891f7b31-3662-4023-bb14-e3f102bdd565\" data-testid=\"conversation-turn-182\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"a711b481-96ee-4be2-8d08-7b6c79d0601b\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"113\" data-end=\"244\"\u003eProfessional \u003cstrong data-start=\"126\" data-end=\"148\"\u003ealuminum mini rail\u003c\/strong\u003e designed for the mounting and support of photovoltaic modules on solar installation structures.\u003c\/p\u003e\n\u003cp data-start=\"246\" data-end=\"480\"\u003eManufactured from high-strength aluminum, this support profile combines lightweight construction, excellent mechanical durability, and superior corrosion resistance, making it ideal for professional outdoor photovoltaic installations.\u003c\/p\u003e\n\u003cp data-start=\"482\" data-end=\"666\"\u003eThe shaped profile with integrated upper grooves allows secure installation of clamps and photovoltaic mounting accessories, ensuring reliable panel fastening and structural stability.\u003c\/p\u003e\n\u003cp data-start=\"668\" data-end=\"742\"\u003eSuitable for residential, commercial, and industrial photovoltaic systems.\u003c\/p\u003e\n\u003chr data-start=\"744\" data-end=\"747\"\u003e\n\u003ch3 data-start=\"749\" data-end=\"769\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"771\" data-end=\"1193\"\u003e\n\u003cli data-start=\"771\" data-end=\"821\"\u003eMini rail for photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"822\" data-end=\"859\"\u003eSupport profile for solar modules\u003c\/li\u003e\n\u003cli data-start=\"860\" data-end=\"899\"\u003eHigh-strength aluminum construction\u003c\/li\u003e\n\u003cli data-start=\"900\" data-end=\"946\"\u003eExcellent weather and corrosion resistance\u003c\/li\u003e\n\u003cli data-start=\"947\" data-end=\"1011\"\u003eCompatible with photovoltaic clamps and mounting accessories\u003c\/li\u003e\n\u003cli data-start=\"1012\" data-end=\"1048\"\u003eLightweight yet robust structure\u003c\/li\u003e\n\u003cli data-start=\"1049\" data-end=\"1081\"\u003eEasy and secure installation\u003c\/li\u003e\n\u003cli data-start=\"1082\" data-end=\"1132\"\u003eSuitable for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1133\" data-end=\"1193\"\u003eDouble-slot profile for standard PV mounting accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1195\" data-end=\"1198\"\u003e\n\u003ch3 data-start=\"1200\" data-end=\"1231\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1233\" data-end=\"1480\"\u003e\n\u003cli data-start=\"1233\" data-end=\"1276\"\u003e\n\u003cstrong data-start=\"1235\" data-end=\"1252\"\u003eProduct Type:\u003c\/strong\u003e PV mini mounting rail\u003c\/li\u003e\n\u003cli data-start=\"1277\" data-end=\"1317\"\u003e\n\u003cstrong data-start=\"1279\" data-end=\"1292\"\u003eMaterial:\u003c\/strong\u003e High-strength aluminum\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1370\"\u003e\n\u003cstrong data-start=\"1320\" data-end=\"1339\"\u003eProfile Design:\u003c\/strong\u003e Double-slot mounting profile\u003c\/li\u003e\n\u003cli data-start=\"1371\" data-end=\"1421\"\u003e\n\u003cstrong data-start=\"1373\" data-end=\"1389\"\u003eApplication:\u003c\/strong\u003e Photovoltaic mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1422\" data-end=\"1480\"\u003e\n\u003cstrong data-start=\"1424\" data-end=\"1441\"\u003eInstallation:\u003c\/strong\u003e Rooftop and outdoor solar structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1482\" data-end=\"1485\"\u003e\n\u003ch3 data-start=\"1487\" data-end=\"1506\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1508\" data-end=\"1657\"\u003e\n\u003cli data-start=\"1508\" data-end=\"1544\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1545\" data-end=\"1579\"\u003eCommercial solar installations\u003c\/li\u003e\n\u003cli data-start=\"1580\" data-end=\"1614\"\u003eIndustrial PV mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1615\" data-end=\"1657\"\u003eRooftop solar panel support structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1659\" data-end=\"1662\"\u003e\n\u003ch3 data-start=\"1664\" data-end=\"1680\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1682\" data-end=\"1984\"\u003e✔ Lightweight and durable aluminum construction\u003cbr data-start=\"1729\" data-end=\"1732\"\u003e✔ High resistance to corrosion and outdoor exposure\u003cbr data-start=\"1783\" data-end=\"1786\"\u003e✔ Compatible with standard photovoltaic mounting accessories\u003cbr data-start=\"1846\" data-end=\"1849\"\u003e✔ Secure and stable module support\u003cbr data-start=\"1883\" data-end=\"1886\"\u003e✔ Simplified installation and alignment\u003cbr data-start=\"1925\" data-end=\"1928\"\u003e✔ Ideal for long-term professional solar installations\u003c\/p\u003e\n\u003chr data-start=\"1986\" data-end=\"1989\"\u003e\n\u003ch3 data-start=\"1991\" data-end=\"2014\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"2016\" data-end=\"2069\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"2016\" data-end=\"2069\" data-is-last-node=\"\"\u003eAluminum mini rail for photovoltaic module mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53888183337293,"sku":null,"price":60.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5696.jpg?v=1778601031"},{"product_id":"stainless-steel-self-tapping-screw-4x35-mm-with-epdm-washer-fastener-for-photovoltaic-mounting-structures","title":"Stainless Steel Self-Tapping Screw 4x35 mm with EPDM Washer – Fastener for Photovoltaic Mounting Structures","description":"\u003cp data-start=\"144\" data-end=\"271\"\u003eProfessional \u003cstrong data-start=\"157\" data-end=\"179\"\u003eself-tapping screw\u003c\/strong\u003e designed for fastening photovoltaic mounting structures and solar installation accessories.\u003c\/p\u003e\n\u003cp data-start=\"273\" data-end=\"524\"\u003eManufactured from corrosion-resistant stainless steel, this fixing screw is supplied with a metal washer and integrated \u003cstrong data-start=\"393\" data-end=\"416\"\u003eEPDM sealing gasket\u003c\/strong\u003e, ensuring secure fastening and reliable protection against water infiltration and harsh weather conditions.\u003c\/p\u003e\n\u003cp data-start=\"526\" data-end=\"705\"\u003eIdeal for use on metal roofs, sheet metal surfaces, and photovoltaic mounting supports, it provides excellent mechanical strength and long-term durability in outdoor environments.\u003c\/p\u003e\n\u003chr data-start=\"707\" data-end=\"710\"\u003e\n\u003ch3 data-start=\"712\" data-end=\"732\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"734\" data-end=\"1126\"\u003e\n\u003cli data-start=\"734\" data-end=\"793\"\u003eSelf-tapping screw for photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"794\" data-end=\"846\"\u003eCorrosion-resistant stainless steel construction\u003c\/li\u003e\n\u003cli data-start=\"847\" data-end=\"901\"\u003eSupplied with metal washer and EPDM sealing gasket\u003c\/li\u003e\n\u003cli data-start=\"902\" data-end=\"938\"\u003eHigh mechanical holding strength\u003c\/li\u003e\n\u003cli data-start=\"939\" data-end=\"983\"\u003eExcellent waterproof sealing performance\u003c\/li\u003e\n\u003cli data-start=\"984\" data-end=\"1014\"\u003eFast and easy installation\u003c\/li\u003e\n\u003cli data-start=\"1015\" data-end=\"1075\"\u003eSuitable for metal roofs and outdoor fixing applications\u003c\/li\u003e\n\u003cli data-start=\"1076\" data-end=\"1126\"\u003eDesigned for professional photovoltaic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1128\" data-end=\"1131\"\u003e\n\u003ch3 data-start=\"1133\" data-end=\"1164\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1166\" data-end=\"1491\"\u003e\n\u003cli data-start=\"1166\" data-end=\"1215\"\u003e\n\u003cstrong data-start=\"1168\" data-end=\"1185\"\u003eProduct Type:\u003c\/strong\u003e Self-tapping mounting screw\u003c\/li\u003e\n\u003cli data-start=\"1216\" data-end=\"1249\"\u003e\n\u003cstrong data-start=\"1218\" data-end=\"1231\"\u003eMaterial:\u003c\/strong\u003e Stainless steel\u003c\/li\u003e\n\u003cli data-start=\"1250\" data-end=\"1278\"\u003e\n\u003cstrong data-start=\"1252\" data-end=\"1271\"\u003eScrew Diameter:\u003c\/strong\u003e 4 mm\u003c\/li\u003e\n\u003cli data-start=\"1279\" data-end=\"1306\"\u003e\n\u003cstrong data-start=\"1281\" data-end=\"1298\"\u003eScrew Length:\u003c\/strong\u003e 35 mm\u003c\/li\u003e\n\u003cli data-start=\"1307\" data-end=\"1330\"\u003e\n\u003cstrong data-start=\"1309\" data-end=\"1318\"\u003eSize:\u003c\/strong\u003e 4 × 35 mm\u003c\/li\u003e\n\u003cli data-start=\"1331\" data-end=\"1382\"\u003e\n\u003cstrong data-start=\"1333\" data-end=\"1346\"\u003eTip Type:\u003c\/strong\u003e High-penetration self-tapping tip\u003c\/li\u003e\n\u003cli data-start=\"1383\" data-end=\"1428\"\u003e\n\u003cstrong data-start=\"1385\" data-end=\"1396\"\u003eWasher:\u003c\/strong\u003e Metal washer with EPDM gasket\u003c\/li\u003e\n\u003cli data-start=\"1429\" data-end=\"1491\"\u003e\n\u003cstrong data-start=\"1431\" data-end=\"1447\"\u003eApplication:\u003c\/strong\u003e PV mounting and outdoor fastening systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1493\" data-end=\"1496\"\u003e\n\u003ch3 data-start=\"1498\" data-end=\"1517\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1519\" data-end=\"1670\"\u003e\n\u003cli data-start=\"1519\" data-end=\"1555\"\u003ePhotovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1556\" data-end=\"1590\"\u003eMetal roof solar installations\u003c\/li\u003e\n\u003cli data-start=\"1591\" data-end=\"1629\"\u003eSheet metal fastening applications\u003c\/li\u003e\n\u003cli data-start=\"1630\" data-end=\"1670\"\u003eOutdoor photovoltaic support systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1672\" data-end=\"1675\"\u003e\n\u003ch3 data-start=\"1677\" data-end=\"1693\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1695\" data-end=\"1956\"\u003e✔ Excellent corrosion resistance\u003cbr data-start=\"1727\" data-end=\"1730\"\u003e✔ Reliable waterproof sealing with EPDM gasket\u003cbr data-start=\"1776\" data-end=\"1779\"\u003e✔ Strong and secure mechanical fastening\u003cbr data-start=\"1819\" data-end=\"1822\"\u003e✔ Fast installation without pre-threading\u003cbr data-start=\"1863\" data-end=\"1866\"\u003e✔ Suitable for harsh outdoor environments\u003cbr data-start=\"1907\" data-end=\"1910\"\u003e✔ Ideal for professional solar installations\u003c\/p\u003e\n\u003chr data-start=\"1958\" data-end=\"1961\"\u003e\n\u003ch3 data-start=\"1963\" data-end=\"1986\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"1988\" data-end=\"2061\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"1988\" data-end=\"2061\" data-is-last-node=\"\"\u003eStainless steel self-tapping screws 4 × 35 mm with EPDM sealing washers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53888200573261,"sku":null,"price":300.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5693.jpg?v=1778601512"},{"product_id":"stainless-steel-self-tapping-screw-4x35-mm-with-washer-epdm-seal-fastener-for-photovoltaic-systems","title":"Stainless Steel Self-Tapping Screw 4x35 mm with Washer \u0026 EPDM Seal – Fastener for Photovoltaic Systems","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"0ab973c0-86f6-4767-a5f9-e8cce1c18794\" data-turn-id-container=\"0ab973c0-86f6-4767-a5f9-e8cce1c18794\" data-testid=\"conversation-turn-186\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"0ab973c0-86f6-4767-a5f9-e8cce1c18794\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"139\" data-end=\"302\"\u003eProfessional \u003cstrong data-start=\"152\" data-end=\"174\"\u003eself-tapping screw\u003c\/strong\u003e designed for fastening photovoltaic mounting structures and solar installation accessories on metal roofs and outdoor surfaces.\u003c\/p\u003e\n\u003cp data-start=\"304\" data-end=\"503\"\u003eManufactured from high-strength stainless steel, this fastener provides excellent durability, superior corrosion resistance, and reliable long-term performance even in harsh environmental conditions.\u003c\/p\u003e\n\u003cp data-start=\"505\" data-end=\"692\"\u003eSupplied with a metal washer and integrated \u003cstrong data-start=\"549\" data-end=\"572\"\u003eEPDM sealing gasket\u003c\/strong\u003e, it ensures effective protection against water infiltration and moisture, improving installation safety and durability.\u003c\/p\u003e\n\u003chr data-start=\"694\" data-end=\"697\"\u003e\n\u003ch3 data-start=\"699\" data-end=\"719\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"721\" data-end=\"1144\"\u003e\n\u003cli data-start=\"721\" data-end=\"780\"\u003eSelf-tapping screw for photovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"781\" data-end=\"833\"\u003eCorrosion-resistant stainless steel construction\u003c\/li\u003e\n\u003cli data-start=\"834\" data-end=\"886\"\u003eMetal washer with integrated EPDM sealing gasket\u003c\/li\u003e\n\u003cli data-start=\"887\" data-end=\"946\"\u003eHigh mechanical holding strength and waterproof sealing\u003c\/li\u003e\n\u003cli data-start=\"947\" data-end=\"979\"\u003eFast and secure installation\u003c\/li\u003e\n\u003cli data-start=\"980\" data-end=\"1036\"\u003eSuitable for sheet metal and metal roof applications\u003c\/li\u003e\n\u003cli data-start=\"1037\" data-end=\"1087\"\u003eDesigned for professional photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1088\" data-end=\"1144\"\u003eExcellent resistance to weather and outdoor exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1146\" data-end=\"1149\"\u003e\n\u003ch3 data-start=\"1151\" data-end=\"1182\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1184\" data-end=\"1507\"\u003e\n\u003cli data-start=\"1184\" data-end=\"1233\"\u003e\n\u003cstrong data-start=\"1186\" data-end=\"1203\"\u003eProduct Type:\u003c\/strong\u003e Self-tapping mounting screw\u003c\/li\u003e\n\u003cli data-start=\"1234\" data-end=\"1267\"\u003e\n\u003cstrong data-start=\"1236\" data-end=\"1249\"\u003eMaterial:\u003c\/strong\u003e Stainless steel\u003c\/li\u003e\n\u003cli data-start=\"1268\" data-end=\"1290\"\u003e\n\u003cstrong data-start=\"1270\" data-end=\"1283\"\u003eDiameter:\u003c\/strong\u003e 4 mm\u003c\/li\u003e\n\u003cli data-start=\"1291\" data-end=\"1312\"\u003e\n\u003cstrong data-start=\"1293\" data-end=\"1304\"\u003eLength:\u003c\/strong\u003e 35 mm\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1336\"\u003e\n\u003cstrong data-start=\"1315\" data-end=\"1324\"\u003eSize:\u003c\/strong\u003e 4 × 35 mm\u003c\/li\u003e\n\u003cli data-start=\"1337\" data-end=\"1388\"\u003e\n\u003cstrong data-start=\"1339\" data-end=\"1352\"\u003eTip Type:\u003c\/strong\u003e High-penetration self-tapping tip\u003c\/li\u003e\n\u003cli data-start=\"1389\" data-end=\"1444\"\u003e\n\u003cstrong data-start=\"1391\" data-end=\"1402\"\u003eWasher:\u003c\/strong\u003e Metal washer with EPDM anti-leak gasket\u003c\/li\u003e\n\u003cli data-start=\"1445\" data-end=\"1507\"\u003e\n\u003cstrong data-start=\"1447\" data-end=\"1463\"\u003eApplication:\u003c\/strong\u003e Outdoor PV mounting and fastening systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1509\" data-end=\"1512\"\u003e\n\u003ch3 data-start=\"1514\" data-end=\"1533\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1535\" data-end=\"1679\"\u003e\n\u003cli data-start=\"1535\" data-end=\"1571\"\u003ePhotovoltaic mounting structures\u003c\/li\u003e\n\u003cli data-start=\"1572\" data-end=\"1606\"\u003eMetal roof solar installations\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1645\"\u003eSheet metal fastening applications\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1679\"\u003eOutdoor solar support systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1681\" data-end=\"1684\"\u003e\n\u003ch3 data-start=\"1686\" data-end=\"1702\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1704\" data-end=\"1972\"\u003e✔ Excellent corrosion resistance\u003cbr data-start=\"1736\" data-end=\"1739\"\u003e✔ Reliable waterproof sealing with EPDM gasket\u003cbr data-start=\"1785\" data-end=\"1788\"\u003e✔ Strong and secure mechanical fastening\u003cbr data-start=\"1828\" data-end=\"1831\"\u003e✔ Fast installation without pre-threading\u003cbr data-start=\"1872\" data-end=\"1875\"\u003e✔ Suitable for harsh outdoor environments\u003cbr data-start=\"1916\" data-end=\"1919\"\u003e✔ Ideal for professional photovoltaic installations\u003c\/p\u003e\n\u003chr data-start=\"1974\" data-end=\"1977\"\u003e\n\u003ch3 data-start=\"1979\" data-end=\"2002\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"2004\" data-end=\"2087\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"2004\" data-end=\"2087\" data-is-last-node=\"\"\u003eStainless steel self-tapping screws 4 × 35 mm with washer and EPDM sealing gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53888214597965,"sku":null,"price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5690.jpg?v=1778602059"},{"product_id":"adjustable-stainless-steel-tile-roof-hook-bracket-for-photovoltaic-mounting-structures","title":"Adjustable Stainless Steel Tile Roof Hook Bracket for Photovoltaic Mounting Structures","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"9e74ea39-5790-45b5-9386-44da3187da14\" data-turn-id-container=\"9e74ea39-5790-45b5-9386-44da3187da14\" data-testid=\"conversation-turn-188\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"9e74ea39-5790-45b5-9386-44da3187da14\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"125\" data-end=\"251\"\u003eProfessional shaped mounting bracket designed for photovoltaic installations on pitched roofs with roof tiles or curved tiles.\u003c\/p\u003e\n\u003cp data-start=\"253\" data-end=\"498\"\u003eManufactured from high-strength stainless steel, this roof hook provides excellent mechanical durability, long service life, and superior resistance to corrosion and weather exposure, making it ideal for professional outdoor solar installations.\u003c\/p\u003e\n\u003cp data-start=\"500\" data-end=\"705\"\u003eIts “Z”-shaped geometry allows the bracket to pass underneath the roof tile without compromising roof stability, while the perforated mounting plate ensures secure fastening to photovoltaic mounting rails.\u003c\/p\u003e\n\u003cp data-start=\"707\" data-end=\"793\"\u003eThe adjustable slotted hole allows easy alignment and positioning during installation.\u003c\/p\u003e\n\u003chr data-start=\"795\" data-end=\"798\"\u003e\n\u003ch3 data-start=\"800\" data-end=\"820\"\u003e⚙️ Main Features\u003c\/h3\u003e\n\u003cul data-start=\"822\" data-end=\"1217\"\u003e\n\u003cli data-start=\"822\" data-end=\"873\"\u003eTile roof hook bracket for photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"874\" data-end=\"904\"\u003eZ-shaped structural design\u003c\/li\u003e\n\u003cli data-start=\"905\" data-end=\"937\"\u003eStainless steel construction\u003c\/li\u003e\n\u003cli data-start=\"938\" data-end=\"991\"\u003eHigh mechanical strength and corrosion resistance\u003c\/li\u003e\n\u003cli data-start=\"992\" data-end=\"1042\"\u003eMulti-hole mounting plate for secure fastening\u003c\/li\u003e\n\u003cli data-start=\"1043\" data-end=\"1096\"\u003eAdjustable slot for alignment during installation\u003c\/li\u003e\n\u003cli data-start=\"1097\" data-end=\"1157\"\u003eCompatible with photovoltaic mounting rails and profiles\u003c\/li\u003e\n\u003cli data-start=\"1158\" data-end=\"1217\"\u003eIdeal for pitched roofs with roof tiles or curved tiles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1219\" data-end=\"1222\"\u003e\n\u003ch3 data-start=\"1224\" data-end=\"1255\"\u003e🔧 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1257\" data-end=\"1465\"\u003e\n\u003cli data-start=\"1257\" data-end=\"1316\"\u003e\n\u003cstrong data-start=\"1259\" data-end=\"1276\"\u003eProduct Type:\u003c\/strong\u003e Adjustable tile roof mounting bracket\u003c\/li\u003e\n\u003cli data-start=\"1317\" data-end=\"1350\"\u003e\n\u003cstrong data-start=\"1319\" data-end=\"1332\"\u003eMaterial:\u003c\/strong\u003e Stainless steel\u003c\/li\u003e\n\u003cli data-start=\"1351\" data-end=\"1406\"\u003e\n\u003cstrong data-start=\"1353\" data-end=\"1369\"\u003eApplication:\u003c\/strong\u003e Photovoltaic roof mounting systems\u003c\/li\u003e\n\u003cli data-start=\"1407\" data-end=\"1465\"\u003e\n\u003cstrong data-start=\"1409\" data-end=\"1426\"\u003eInstallation:\u003c\/strong\u003e Under-tile mounting on pitched roofs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1467\" data-end=\"1470\"\u003e\n\u003ch3 data-start=\"1472\" data-end=\"1499\"\u003e📐 Estimated Dimensions\u003c\/h3\u003e\n\u003cul data-start=\"1501\" data-end=\"1725\"\u003e\n\u003cli data-start=\"1501\" data-end=\"1543\"\u003e\n\u003cstrong data-start=\"1503\" data-end=\"1522\"\u003eOverall length:\u003c\/strong\u003e approx. 180–220 mm\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1583\"\u003e\n\u003cstrong data-start=\"1546\" data-end=\"1564\"\u003eBracket width:\u003c\/strong\u003e approx. 30–40 mm\u003c\/li\u003e\n\u003cli data-start=\"1584\" data-end=\"1626\"\u003e\n\u003cstrong data-start=\"1586\" data-end=\"1609\"\u003eMaterial thickness:\u003c\/strong\u003e approx. 4–5 mm\u003c\/li\u003e\n\u003cli data-start=\"1627\" data-end=\"1676\"\u003e\n\u003cstrong data-start=\"1629\" data-end=\"1655\"\u003ePerforated plate size:\u003c\/strong\u003e approx. 70 × 70 mm\u003c\/li\u003e\n\u003cli data-start=\"1677\" data-end=\"1725\"\u003e\n\u003cstrong data-start=\"1679\" data-end=\"1704\"\u003eAdjustable slot size:\u003c\/strong\u003e approx. 10 × 30 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1727\" data-end=\"1730\"\u003e\n\u003ch3 data-start=\"1732\" data-end=\"1751\"\u003e🌐 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1753\" data-end=\"1938\"\u003e\n\u003cli data-start=\"1753\" data-end=\"1789\"\u003eResidential photovoltaic systems\u003c\/li\u003e\n\u003cli data-start=\"1790\" data-end=\"1829\"\u003eCommercial solar roof installations\u003c\/li\u003e\n\u003cli data-start=\"1830\" data-end=\"1883\"\u003ePitched roofs with tiles or curved roof coverings\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1938\"\u003eProfessional rooftop photovoltaic mounting systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1940\" data-end=\"1943\"\u003e\n\u003ch3 data-start=\"1945\" data-end=\"1961\"\u003e✅ Advantages\u003c\/h3\u003e\n\u003cp data-start=\"1963\" data-end=\"2262\"\u003e✔ Excellent corrosion resistance for outdoor environments\u003cbr data-start=\"2020\" data-end=\"2023\"\u003e✔ Secure and stable mounting structure\u003cbr data-start=\"2061\" data-end=\"2064\"\u003e✔ Adjustable positioning for easier installation\u003cbr data-start=\"2112\" data-end=\"2115\"\u003e✔ Compatible with standard PV mounting rails\u003cbr data-start=\"2159\" data-end=\"2162\"\u003e✔ Strong mechanical support for solar modules\u003cbr data-start=\"2207\" data-end=\"2210\"\u003e✔ Designed for long-term photovoltaic applications\u003c\/p\u003e\n\u003chr data-start=\"2264\" data-end=\"2267\"\u003e\n\u003ch3 data-start=\"2269\" data-end=\"2292\"\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul data-start=\"2294\" data-end=\"2379\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"2294\" data-end=\"2379\" data-is-last-node=\"\"\u003eAdjustable stainless steel tile roof hook bracket for photovoltaic mounting systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53888244580685,"sku":null,"price":24.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5689.jpg?v=1778602642"}],"url":"https:\/\/greenenergy-repair.com\/es\/collections\/accessories-components.oembed?page=3","provider":"Green Energy","version":"1.0","type":"link"}