{"product_id":"electronicon-e62-e81-472d10-4-7-µf-1200-vac-mkp-power-capacitor","title":"ELECTRONICON E62.E81-472D10 – 4.7 µF 1200 VAC MKP Power Capacitor","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eUsed product.\u003c\/strong\u003e The \u003cstrong\u003eELECTRONICON E62.E81-472D10\u003c\/strong\u003e is an industrial \u003cstrong\u003eMKP film power capacitor\u003c\/strong\u003e designed for high-voltage AC power electronics and electrical applications. According to the component markings and technical documentation, it has a nominal capacitance of \u003cstrong\u003e4.7 µF ±10%\u003c\/strong\u003e and a rated voltage of \u003cstrong\u003e1200 VAC\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe capacitor uses \u003cstrong\u003emetallized polypropylene film (MKP)\u003c\/strong\u003e technology and features a \u003cstrong\u003ecylindrical metal housing\u003c\/strong\u003e with \u003cstrong\u003ecastor oil impregnation\u003c\/strong\u003e, as indicated by the component marking. The model belongs to the \u003cstrong\u003eE62 Heavy Duty AC\/DC\u003c\/strong\u003e series, designed for demanding power electronics applications.\u003c\/p\u003e\n\u003ch3\u003e⚙️ Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ELECTRONICON\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e E62.E81-472D10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Power capacitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e \u003cstrong\u003eMKP – metallized polypropylene film\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Capacitance:\u003c\/strong\u003e \u003cstrong\u003e4.7 µF\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTolerance:\u003c\/strong\u003e \u003cstrong\u003e±10%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e \u003cstrong\u003e1200 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicated RMS Voltage:\u003c\/strong\u003e \u003cstrong\u003e850 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\/Overvoltage US:\u003c\/strong\u003e \u003cstrong\u003e2100 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUBB Voltage:\u003c\/strong\u003e \u003cstrong\u003e2580 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUBG Voltage:\u003c\/strong\u003e \u003cstrong\u003e3000 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current Imax:\u003c\/strong\u003e \u003cstrong\u003e16 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current Î:\u003c\/strong\u003e \u003cstrong\u003e0.42 kA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent IS:\u003c\/strong\u003e \u003cstrong\u003e1.3 kA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Resistance RS:\u003c\/strong\u003e \u003cstrong\u003e4.7 mΩ\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent Inductance Le:\u003c\/strong\u003e \u003cstrong\u003e60 nH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Resistance Rth:\u003c\/strong\u003e \u003cstrong\u003e13.8 K\/W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Energy WN:\u003c\/strong\u003e \u003cstrong\u003e3.4 Ws\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. \u003cstrong\u003eØ40 × 81 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprox. Weight:\u003c\/strong\u003e \u003cstrong\u003e0.11 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e \u003cstrong\u003eD1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e \u003cstrong\u003eDual Faston terminals\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e \u003cstrong\u003eM8 screw\/stud\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e \u003cstrong\u003e-25 °C to +85 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e \u003cstrong\u003eIEC 61071\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilling:\u003c\/strong\u003e \u003cstrong\u003eCastor Oil\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Manufacture:\u003c\/strong\u003e \u003cstrong\u003eMade in Germany\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Date Code:\u003c\/strong\u003e \u003cstrong\u003e18\/10\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e⚡ Function\u003c\/h3\u003e\n\u003cp\u003eThis capacitor is designed to operate as a \u003cstrong\u003epower capacitive component\u003c\/strong\u003e within high-voltage electrical systems.\u003c\/p\u003e\n\u003cp\u003eDepending on the specific circuit, it may be used for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage and current filtering\u003c\/li\u003e\n\u003cli\u003eReactive power compensation and management\u003c\/li\u003e\n\u003cli\u003eReduction of unwanted electrical signal components\u003c\/li\u003e\n\u003cli\u003eTemporary energy storage\u003c\/li\u003e\n\u003cli\u003ePower conversion circuits\u003c\/li\u003e\n\u003cli\u003eFiltering and stabilization in high-voltage AC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe combination of \u003cstrong\u003e4.7 µF capacitance\u003c\/strong\u003e and \u003cstrong\u003e1200 VAC rated voltage\u003c\/strong\u003e makes this component suitable for power circuits requiring high electrical strength and robust operation.\u003c\/p\u003e\n\u003ch3\u003e🏭 Construction \u0026amp; Installation\u003c\/h3\u003e\n\u003cp\u003eThe capacitor features a \u003cstrong\u003ecylindrical metal housing\u003c\/strong\u003e approximately \u003cstrong\u003e40 mm in diameter and 81 mm long\u003c\/strong\u003e. The D1 design uses \u003cstrong\u003edual Faston connections\u003c\/strong\u003e for electrical connection and an \u003cstrong\u003eM8 mounting stud\u003c\/strong\u003e for mechanical fixation.The \u003cstrong\u003eMKP metallized polypropylene film\u003c\/strong\u003e construction is designed for power applications, while the \u003cstrong\u003ecastor oil impregnation\u003c\/strong\u003e contributes to the insulation and operating characteristics of the component.Installation must comply with the capacitor's rated values and provide suitable clearances, electrical connections and protection systems according to the equipment in which it is installed.\u003c\/p\u003e\n\u003ch3\u003e🌐 Applications\u003c\/h3\u003e\n\u003cp\u003eSuitable, subject to electrical compatibility, for industrial \u003cstrong\u003epower electronics\u003c\/strong\u003e applications including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInverters and power converters\u003c\/li\u003e\n\u003cli\u003eAC\/DC and DC\/AC conversion systems\u003c\/li\u003e\n\u003cli\u003ePower filters\u003c\/li\u003e\n\u003cli\u003eCompensation circuits\u003c\/li\u003e\n\u003cli\u003eIndustrial drives\u003c\/li\u003e\n\u003cli\u003eHigh-voltage electrical equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial energy conversion and management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eE62 series\u003c\/strong\u003e is designed for demanding \u003cstrong\u003eAC\/DC power applications\u003c\/strong\u003e and includes components rated for high operating voltages.\u003c\/p\u003e\n\u003ch3\u003e💡 Key Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1200 VAC\u003c\/strong\u003e rated voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4.7 µF\u003c\/strong\u003e capacitance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMKP metallized polypropylene film\u003c\/strong\u003e technology\u003c\/li\u003e\n\u003cli\u003eRobust construction for power applications\u003c\/li\u003e\n\u003cli\u003eLow series resistance of \u003cstrong\u003e4.7 mΩ\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow equivalent inductance of \u003cstrong\u003e60 nH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum current rating of \u003cstrong\u003e16 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompact \u003cstrong\u003e40 × 81 mm\u003c\/strong\u003e cylindrical design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Faston\u003c\/strong\u003e electrical connections\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM8 mounting stud\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMade in Germany\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e⚠️ Possible Faults \u0026amp; Anomalies\u003c\/h3\u003e\n\u003cp\u003eA deteriorated power capacitor may cause various issues in the equipment in which it is installed, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduced capacitance compared with the nominal value\u003c\/li\u003e\n\u003cli\u003eIncreased leakage current\u003c\/li\u003e\n\u003cli\u003eIncreased operating temperature\u003c\/li\u003e\n\u003cli\u003eIncreased electrical losses\u003c\/li\u003e\n\u003cli\u003eDamaged or loose terminals\u003c\/li\u003e\n\u003cli\u003eLoss of insulation\u003c\/li\u003e\n\u003cli\u003eInternal short circuit\u003c\/li\u003e\n\u003cli\u003eOpen circuit in the event of component failure\u003c\/li\u003e\n\u003cli\u003eInstability or abnormal behavior in filtering circuits\u003c\/li\u003e\n\u003cli\u003eActivation of equipment protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe internal electrical condition of the capacitor cannot be determined from photographs alone.\u003c\/strong\u003e Proper testing requires instrumental measurements of capacitance and insulation, together with loss and current measurements where applicable.\u003c\/p\u003e\n\u003ch3\u003e🛡️ Safety \u0026amp; Product Condition\u003c\/h3\u003e\n\u003cp\u003eThe photographed component is a \u003cstrong\u003eused product\u003c\/strong\u003e and may show normal cosmetic signs of previous use and handling on the metal housing and terminals. Before use, it is necessary to verify the \u003cstrong\u003eintegrity of the housing, condition of the terminals, actual capacitance and electrical insulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e⚠️ As this is a \u003cstrong\u003ehigh-voltage capacitor\u003c\/strong\u003e, it must be considered potentially charged until it has been properly discharged. Handling and testing must only be carried out using procedures and equipment suitable for the component's rated voltage.\u003c\/p\u003e\n\u003ch3\u003e📦 Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1 × ELECTRONICON E62.E81-472D10 Power Capacitor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eCapacitance: \u003cstrong\u003e4.7 µF ±10%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated Voltage: \u003cstrong\u003e1200 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Faston terminals and M8 mounting stud\u003c\/strong\u003e, according to the model\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electronicon","offers":[{"title":"Default Title","offer_id":54640133112141,"sku":null,"price":25.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6622.jpg?v=1788361713","url":"https:\/\/greenenergy-repair.com\/el\/products\/electronicon-e62-e81-472d10-4-7-%c2%b5f-1200-vac-mkp-power-capacitor","provider":"Green Energy","version":"1.0","type":"link"}