{"product_id":"power-one-3m22-99-0f-dc-input-fuse-board-aurora-trio","title":"Power-One 3M22-99-0F | DC Input Fuse Board | Aurora TRIO","description":"\u003ch3 dir=\"auto\" data-start=\"63\" data-end=\"85\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e📝 \u003cstrong data-start=\"70\" data-end=\"85\"\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"86\" data-end=\"720\"\u003e\u003cstrong data-start=\"86\" data-end=\"103\"\u003eUsed product.\u003c\/strong\u003e\u003cbr\u003eOriginal \u003cstrong data-start=\"113\" data-end=\"126\"\u003ePower-One\u003c\/strong\u003e electronic circuit board, part number \u003cstrong data-start=\"165\" data-end=\"179\"\u003e3M22-99-0F\u003c\/strong\u003e, equipped with fuse holders, fuses for DC circuits and connection terminals. The component layout and \u003cstrong data-start=\"282\" data-end=\"290\"\u003eIN1+\u003c\/strong\u003e and \u003cstrong data-start=\"295\" data-end=\"303\"\u003eIN2+\u003c\/strong\u003e markings indicate a function associated with the inverter's DC input circuits.\u003cbr\u003eThe board is offered as a replacement part for maintenance and repair of Power-One photovoltaic inverters. The \u003cstrong data-start=\"494\" data-end=\"522\"\u003eAurora TRIO 20.0\/27.6 TL\u003c\/strong\u003e series includes three-phase inverters with different wiring section configurations. Compatibility with the specific model must be confirmed by comparing the board part number and equipment version.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"721\" data-end=\"751\"\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong data-start=\"728\" data-end=\"751\"\u003eMain Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"752\" data-end=\"1189\"\u003e\n\u003cli data-start=\"752\" data-end=\"774\"\u003e\n\u003cstrong data-start=\"754\" data-end=\"764\"\u003eBrand:\u003c\/strong\u003e Power-One\u003c\/li\u003e\n\u003cli data-start=\"775\" data-end=\"808\"\u003e\n\u003cstrong data-start=\"777\" data-end=\"797\"\u003ePCB part number:\u003c\/strong\u003e 3M22-99-0F\u003c\/li\u003e\n\u003cli data-start=\"809\" data-end=\"861\"\u003e\n\u003cstrong data-start=\"811\" data-end=\"820\"\u003eType:\u003c\/strong\u003e Fuse board and DC input connection board\u003c\/li\u003e\n\u003cli data-start=\"862\" data-end=\"899\"\u003e\n\u003cstrong data-start=\"864\" data-end=\"888\"\u003eConnection markings:\u003c\/strong\u003e IN1+, IN2+\u003c\/li\u003e\n\u003cli data-start=\"900\" data-end=\"963\"\u003e\n\u003cstrong data-start=\"902\" data-end=\"912\"\u003eFuses:\u003c\/strong\u003e Present and installed, as shown in the photographs\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1016\"\u003e\n\u003cstrong data-start=\"966\" data-end=\"1000\"\u003eVoltage marking on some fuses:\u003c\/strong\u003e Up to 1000 V DC\u003c\/li\u003e\n\u003cli data-start=\"1017\" data-end=\"1081\"\u003e\n\u003cstrong data-start=\"1019\" data-end=\"1035\"\u003eConnections:\u003c\/strong\u003e Screw terminal blocks and multipole connector\u003c\/li\u003e\n\u003cli data-start=\"1082\" data-end=\"1136\"\u003e\n\u003cstrong data-start=\"1084\" data-end=\"1110\"\u003eAdditional components:\u003c\/strong\u003e Resistors and test points\u003c\/li\u003e\n\u003cli data-start=\"1137\" data-end=\"1189\"\u003e\n\u003cstrong data-start=\"1139\" data-end=\"1156\"\u003eConstruction:\u003c\/strong\u003e Industrial printed circuit board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1190\" data-end=\"1215\"\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong data-start=\"1197\" data-end=\"1215\"\u003eMain Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1216\" data-end=\"1524\"\u003e\n\u003cli data-start=\"1216\" data-end=\"1248\"\u003eProtects circuits using fuses.\u003c\/li\u003e\n\u003cli data-start=\"1249\" data-end=\"1275\"\u003eConnects DC input lines.\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1524\"\u003eInterfaces with the inverter's internal circuits.\u003cbr\u003e\u003cstrong data-start=\"1328\" data-end=\"1337\"\u003eNote:\u003c\/strong\u003e The general function is inferred from the markings and component layout. No official documentation directly linking part number 3M22-99-0F to a specific inverter model has been verified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"1525\" data-end=\"1549\"\u003e\u003cspan role=\"text\"\u003e🧩 \u003cstrong data-start=\"1532\" data-end=\"1549\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1550\" data-end=\"1845\"\u003ePotentially intended for Power-One Aurora photovoltaic inverters.\u003cbr\u003eThe Aurora TRIO series includes the \u003cstrong data-start=\"1652\" data-end=\"1685\"\u003eTRIO-20.0-TL and TRIO-27.6-TL\u003c\/strong\u003e models, available in different versions. However, compatibility with all these models cannot be guaranteed without confirmation of the replacement part number.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" data-start=\"1846\" data-end=\"1870\"\u003e\u003cspan role=\"text\"\u003e🛠️ \u003cstrong data-start=\"1854\" data-end=\"1870\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1871\" data-end=\"2046\"\u003e\n\u003cli data-start=\"1871\" data-end=\"1902\"\u003ePhotovoltaic inverter repair.\u003c\/li\u003e\n\u003cli data-start=\"1903\" data-end=\"1940\"\u003eReplacement of damaged fuse boards.\u003c\/li\u003e\n\u003cli data-start=\"1941\" data-end=\"1989\"\u003eMaintenance of compatible Power-One equipment.\u003c\/li\u003e\n\u003cli data-start=\"1990\" data-end=\"2046\"\u003eRecovery and reuse of original electronic spare parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2047\" data-end=\"2068\"\u003e\u003cspan role=\"text\"\u003e💡 \u003cstrong data-start=\"2054\" data-end=\"2068\"\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2069\" data-end=\"2287\"\u003e\n\u003cli data-start=\"2069\" data-end=\"2132\"\u003eOriginal replacement part with a visible identification code.\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2176\"\u003eFuses and fuse holders already installed.\u003c\/li\u003e\n\u003cli data-start=\"2177\" data-end=\"2215\"\u003eIntegrated terminals and connectors.\u003c\/li\u003e\n\u003cli data-start=\"2216\" data-end=\"2287\"\u003eSuitable for maintenance work, subject to compatibility verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2288\" data-end=\"2317\"\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong data-start=\"2296\" data-end=\"2317\"\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2318\" data-end=\"2510\"\u003e\n\u003cli data-start=\"2318\" data-end=\"2333\"\u003eUsed product.\u003c\/li\u003e\n\u003cli data-start=\"2334\" data-end=\"2379\"\u003eBoard photographed from the front and back.\u003c\/li\u003e\n\u003cli data-start=\"2380\" data-end=\"2425\"\u003eFuses included as shown in the photographs.\u003c\/li\u003e\n\u003cli data-start=\"2426\" data-end=\"2473\"\u003eElectrical functionality has not been tested.\u003c\/li\u003e\n\u003cli data-start=\"2474\" data-end=\"2510\"\u003ePossible signs of use and storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2511\" data-end=\"2538\"\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong data-start=\"2518\" data-end=\"2538\"\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2539\" data-end=\"2640\"\u003e\n\u003cli data-start=\"2539\" data-end=\"2640\"\u003e1 Power-One \u003cstrong data-start=\"2553\" data-end=\"2567\"\u003e3M22-99-0F\u003c\/strong\u003e electronic circuit board, in the configuration shown in the photographs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\" data-start=\"2641\" data-end=\"2659\"\u003e\u003cspan role=\"text\"\u003e🟢 \u003cstrong data-start=\"2648\" data-end=\"2659\"\u003eSummary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2660\" data-end=\"3033\" data-is-last-node=\"\" data-is-only-node=\"\"\u003ePower-One circuit board with fuse holders and DC input connections, offered as a replacement part for compatible photovoltaic inverters. Verification of the part number and revision before purchase is recommended.\u003cbr\u003e\u003cstrong data-start=\"2874\" data-end=\"2886\"\u003eWarning:\u003c\/strong\u003e This component is intended for circuits that may be subject to high voltages. Installation and testing must be carried out by qualified personnel.\u003c\/p\u003e","brand":"Power-one","offers":[{"title":"Default Title","offer_id":55072510705997,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5972.jpg?v=1792086040","url":"https:\/\/greenenergy-repair.com\/de\/products\/power-one-3m22-99-0f-dc-input-fuse-board-aurora-trio","provider":"Green Energy","version":"1.0","type":"link"}